Specific absorption rate in rats exposed to 2,450-MHz microwaves under seven exposure conditions
Authors:C K Chou  A W Guy  J A McDougall  H Lai
Abstract:Both positive and negative biological effects of microwaves on drug actions in rats exposed to 1-mW/cm2, 2,450-MHz microwaves have been reported by several investigators. We conducted dosimetry studies for seven different exposure conditions to determine whether these different results could be due to the rats having been exposed differently. They included anterior and posterior exposures in a circular waveguide, near field, far field with E- or H-field parallel to the long axis of the body and dorsal exposure in a miniature anechoic chamber with E- or H-field parallel to the long axis of the body. The average specific absorption rates (SARs) in the head, tail, and body of the exposed rats were measured by means of a calorimetry system. The local SARs at eight locations in the brain were determined by temperature measurement with Vitek probes. Intensive coupling of energy to the tail when it was exposed parallel to the E-field was shown by thermography. For the same average incident power density, the average SARs in the heads of rats were about two times higher in the circular waveguide than for other exposures. The local SARs in the brain varied for different exposure conditions. Statistical comparisons of SARs under the different exposure conditions are presented.
Keywords:SAR  rat  head  tail  brain sites  2  450 MHz  calorimetry