首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Determination of 3-(5-cyclopropyl-1,2,4-oxadiazol-3-yl)-5-(1-methylethyl)imidazo[1,5-a]quinoxalin-4(5H)-one in serum by high-performance liquid chromatography
Authors:W Z Zhong
Abstract:A high-performance liquid chromatographic assay with solid-phase extraction (SPE) for the rapid and sensitive quantitation of 3-(5-cyclopropyl-1,2,4-oxadiazol-3-yl)-5-(1-methylethyl)imidazo1,5-a]quinoxalin-4(5H)-one (I, U-78875) in serum is described. The validation results indicated that the present method had excellent intra- and inter-assay precision (≤ 9.5%, mean ± S.D. = 3.9±3.0%, n = 25) and accuracy (≤ 10.0%, mean ± S.D. = 3.0 ± 2.9%, n = 25), as well as improved sensitivity (2 ng/ml, using a 100-μl injection). Each chromatographic run is only 10 min and the organic solvent for the extraction of I and internal standard (U-82217) from serum was only 300 μl. The application results obtained from the SPE method were in good agreement with the advanced automated sample preparation method.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号