A quantitative, non-radioactive single-nucleotide insertion assay for analysis of DNA replication fidelity by using an automated DNA sequencer |
| |
Authors: | Michiko Kimoto Shigeyuki Yokoyama Ichiro Hirao |
| |
Affiliation: | Protein Research Group, RIKEN Genomic Sciences Center, 1-7-22 Suehiro-cho, Tsurumi-ku, Yokohama, Kanagawa 230-0045, Japan. |
| |
Abstract: | A method to determine the steady-state kinetic parameters of single-nucleotide insertion in replication was developed using an automated DNA sequencer. The insertion of nucleoside 5'-triphosphates into a 6-carboxyfluorescein-labeled primer by DNA polymerase was quantified from the band pattern on a gel using GeneScan software. The parameters determined by this method were consistent with those obtained by the conventional radioisotope-labeling method. This non-radioactive, fluorescent-based method is rapid and can handle a large number of samples to assess cognate or non-cognate base pair formation between natural or unnatural bases in replication. |
| |
Keywords: | DNA polymerase GeneScan kinetic parameters single-nucleotide insertion unnatural base pairs |
本文献已被 PubMed SpringerLink 等数据库收录! |