首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Guidelines and considerations for the use of system suitability and quality control samples in mass spectrometry assays applied in untargeted clinical metabolomic studies
Authors:David Broadhurst  Royston Goodacre  Stacey N Reinke  Julia Kuligowski  Ian D Wilson  Matthew R Lewis  Warwick B Dunn
Institution:1.School of Science, Centre for Integrative Metabolomics and Computational Biology,Edith Cowan University,Perth,Australia;2.School of Chemistry,Manchester Institute of Biotechnology, University of Manchester,Manchester,UK;3.Separation Sciences and Metabolomics Laboratory,Murdoch University,Perth,Australia;4.Neonatal Research Unit,Health Research Institute La Fe,Valencia,Spain;5.Division of Computational and Systems Medicine, Department of Surgery and Cancer,Imperial College London,London,UK;6.School of Biosciences,University of Birmingham,Birmingham,UK;7.Phenome Centre Birmingham,University of Birmingham,Birmingham,UK;8.Institute of Metabolism and Systems Research,University of Birmingham,Birmingham,UK
Abstract:

Background

Quality assurance (QA) and quality control (QC) are two quality management processes that are integral to the success of metabolomics including their application for the acquisition of high quality data in any high-throughput analytical chemistry laboratory. QA defines all the planned and systematic activities implemented before samples are collected, to provide confidence that a subsequent analytical process will fulfil predetermined requirements for quality. QC can be defined as the operational techniques and activities used to measure and report these quality requirements after data acquisition.

Aim of review

This tutorial review will guide the reader through the use of system suitability and QC samples, why these samples should be applied and how the quality of data can be reported.

Key scientific concepts of review

System suitability samples are applied to assess the operation and lack of contamination of the analytical platform prior to sample analysis. Isotopically-labelled internal standards are applied to assess system stability for each sample analysed. Pooled QC samples are applied to condition the analytical platform, perform intra-study reproducibility measurements (QC) and to correct mathematically for systematic errors. Standard reference materials and long-term reference QC samples are applied for inter-study and inter-laboratory assessment of data.
Keywords: