首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Enzymatic assay for total plasma Cys
Authors:Han Qinghong  Hoffman Robert M
Institution:AntiCancer, Inc., 7917 Ostrow Street, San Diego, CA 92111, USA.
Abstract:Patients with vascular disease and end-stage renal disease have significantly higher concentrations of plasma total Cys (tCys) than do healthy individuals. Described here is a nonradioactive, precise, rapid and sensitive enzymatic colorimetric assay for tCys in plasma samples and is homogeneous in that it avoids separation methods. The tCys assay uses only the recombinant enzymes methionine alpha,gamma-lyase (rMETase) and S-adenosylhomocysteine hydrolase (rSAHH) cloned from Pseudomonas putida and Trichomonas vaginalis, respectively. The rSAHH traps homocysteine and the rMETase thereby produces H(2)S exclusively from Cys. The reaction product, H(2)S, is measured colorimetrically following its reaction with N,N-dibutylphenylenediamine (DBPDA). The procedure takes 3-4 h to complete.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏