Determination of schizandrin in rat plasma by high-performance liquid chromatography-mass spectrometry and its application in rat pharmacokinetic studies |
| |
Authors: | Xu Meijuan Wang Guangji Xie Haitang Wang Rui Wang Wei Li Xiaoyu Li Hao Zhu Danni Yue Lei |
| |
Affiliation: | Key Lab of Drug Metabolism and Pharmacokinetics, China Pharmaceutical University, Nanjing 210009, China. |
| |
Abstract: | ![]() A sensitive liquid chromatography-mass spectrometric (LC/MS) method for the quantification of schizandrin in rat plasma was developed and validated after solid-phase extraction (SPE). Chromatographic separation was achieved on a reversed-phase Shimadzu C(18) column with the mobile phase of acetonitrile-sodium acetate (10 micromol/L) and step gradient elution resulted in a total run time of about 11.7 min. The analytes were detected using an electrospray positive ionization mass spectrometry in the selected ion monitoring (SIM) mode. A good linear relationship was obtained in the concentration range studied (0.005-2.000 microg/mL) (r=0.9999). Lower limit of quantification (LLOQ) was 5 ng/mL and the lower limit of detection (LLOD) was 2 ng/mL using 100 microL plasma sample. Average recoveries ranged from 75.85 to 88.51% in plasma at the concentrations of 0.005, 0.100 and 1.000 microg/mL. Intra- and inter-day relative standard deviations were 5.95-12.93% and 3.87-14.53%, respectively. This method was successfully applied for the pharmacokinetic studies in rats. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|