Assessment of ablation catheter contact on valve annulus: Implications on accessory pathway ablation
Institution:1. Cardiology Department, Royal Melbourne Hospital, Melbourne, Australia;2. Cardiology Department, Royal Darwin Hospital, Darwin, Australia;3. Department of Clinical Medicine, Macquarie University, Sydney, Australia;4. Cardiology Department, Royal Hobart Hospital, Hobart, Australia;5. Cardiology Department, James Cook University Hospital, Middlesbrough, UK;6. Cardiology Department, The Alfred Hospital, Melbourne, Australia;7. Department of Medicine, University of Melbourne, Melbourne, Australia
Abstract:BackgroundCatheter-tissue contact force is an important factor influencing lesion size and efficacy and thereby potential for arrhythmia recurrence following accessory pathway (AP) radiofrequency ablation. We aim to evaluate adequacy and perception of catheter contact on the tricuspid and mitral annuli.MethodsData were collected from 42 patients undergoing catheter ablation. Operators were blinded to contact force information and reported perceived contact (poor, moderate, or good) while positioning the catheter at four tricuspid annular sites (12, 9, 6 and 4 o'clock positions; abbreviated as TA12, TA9, TA6 and TA4) and three mitral annular sites (3, 5 and 7 o'clock positions; abbreviated as MA3, MA5 and MA7) through long vascular sheaths.ResultsThe highest and lowest mean contact forces were obtained at MA7 (13.3 ± 1.7 g) and TA12 (3.6 g ± 1.3 g) respectively. Mean contact force on tricuspid annulus (6.1 g ± 0.9 g) was lower than mitral annulus (9.8 ± 0.9 g) locations (p = 0.0036), with greater proportion of sites with <10 g contact force (81.7% vs 60.4%; p = 0.0075). Perceived contact had no impact on measured mean contact force for both mitral and tricuspid annular positions (p = 0.959 and 0.671 respectively). There was correlation of both impedance and atrial electrogram amplitude with contact force, though insufficient to be clinically applicable.ConclusionA high proportion of annular catheter applications have low contact force despite being performed with long vascular sheaths in the hands of experienced operators. In addition, there was no impact of operator perceived contact force on actual measured contact force. This may carry implications for success of AP ablation.
Keywords:Ablation  Contact force  Accessory pathway  Mitral annulus  Tricuspid annulus
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号