首页 | 本学科首页   官方微博 | 高级检索  
     


Validation performance comparison for finite element models of the human brain
Authors:Logan E. Miller  Jillian E. Urban
Affiliation:Center for Injury Biomechanics, Wake Forest University, Winston-Salem, NC, USA
Abstract:The objective of this study was to compare the performance of six validated brain finite element (FE) models to localized brain motion validation data in five experimental configurations. Model performance was measured using the objective metric CORA (CORrelation and Analysis), where higher ratings represent better correlation. The KTH model achieved the highest average CORA rating, and the ABM received the highest average rating among models robustly validated against five cadaver impacts in three directions. This technique can be more frequently employed to build better models and, when associated limitations are well understood, to compare inter-model performance under similar conditions.
Keywords:Brain model  head injury  validation  optimization  finite element model  CORA
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号