Cyclic AMP response in cells exposed to electric fields of different frequencies and intensities |
| |
Authors: | G. Knedlitschek M. Noszvai-Nagy H. Meyer-Waarden J. Schimmelpfeng K. F. Weibezahn H. Dertinger |
| |
Affiliation: | (1) Institut für Toxikologie, Kernforschungszentrum Karlsruhe, Postfach 3640, D-76021 Karlsruhe, Germany |
| |
Abstract: | The action on intracellular cyclic AMP (cAMP) of therapeutically used 4000-Hz electric fields was investigated and compared with 50-Hz data. Cultured mouse fibroblasts were exposed for 5 minutes to 4000-Hz sine wave internal electric fields between 3 mV/m and 30 V/m applied within culture medium. A statistically significant decrease in cellular cAMP concentration relative to unexposed cells was observed for fields higher than 10 mV/m. The drop in cAMP was most pronounced at lower field strengths (71 % of controls at 30 mV/m) and tended to disappear at higher field strengths. An increase of cAMP content was observed with 50-Hz electric fields, as was also the case when 4000-Hz fields were modulated with certain low frequencies. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |