首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of prednisolone,prednisone, and cortisol in human plasma by high-performance liquid chromatography
Authors:N.R. Scott  J. Chakraborty  V. Marks
Affiliation:1. Department of Biochemistry, Bromley Hospital, Kent, England;2. Clinical Biochemistry Division, Department of Biochemistry, University of Surrey, Guildford, Surrey, England
Abstract:A method is described for the measurement of prednisone and prednisolone in human plasma by high-performance liquid chromatography (hplc). An ether/dichloromethane extract (60:40, vv) of plasma is evaporated to dryness and chromatographed on a 250 × 4.5-mm Whatman Partisil column with uv detection at 239 nm. Prednisone, prednisolone cortisol, and the internal standard dexamethasone are satisfactorily resolved with the elution system of water-saturated dichloromethane/ethanol (95:4, vv). The hplc method can be used for plasma prednisolone concentrations as low as 25 ng/ml. The values correlate well with those obtained by a radioimmunoassay procedure for prednisolone.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号