Biological monitoring of occupational exposure to 1-bromopropane by means of urinalysis for 1-bromopropane and bromide ion |
| |
Authors: | Toshio Kawai Akito Takeuchi Yuriko Miyama Kunihiro Sakamto Zuo-Wen Zhang Kae Higashikawa Masayuki Ikeda |
| |
Affiliation: | a Osaka Occupational Health Service Center, Osaka 550-0001, Japan.b Kyoto Industrial Health Association, 67 Nishinokyo-Kitatsuboicho, Nakagyo-ku, Kyoto 604-8472, Japan. |
| |
Abstract: | The purposes of the present study are (1) to develop a sensitive analytical method to measure 1-bromopropane (1-BP) in urine, (2) to examine if 1-BP or bromide ion (Br) in urine is a useful biomarker of exposure to 1-BP, and (3) to identify the lowest 1-BP exposure concentration the method thus established can biomonitor. A factory survey was carried out on Friday, and 33 workers (all men) in cleaning and painting workshops participated; each worker was equipped with a diffusive sampler (carbon cloth KF-1500 as an adsorbent) to monitor 1-BP vapour for an 8-h shift, and offered a urine sample at the end of the shift for measurement of 1-BP and Br in urine. In addition, 10 non-exposed men offered urine samples as controls. The performance of the carbon cloth diffusive sampler was examined to confirm that the sampler is suitable for monitoring time-weighted average 1-BP vapour exposure. A head-space GC technique was employed for analysis of 1-BP in urine, whereas Br in urine was analysed by ECD-GC after derivatization to methyl bromide. The workers were exposed to vapours of seven other solvents (i.e. toluene, xylenes, ethylbenzene, acetone, etc.) in addition to 1-BP vapour; the 1-BP vapour concentration was 1.4 ppm as GM and 28 ppm as the maximum. Multiple regression analysis however showed that 1-BP was the only variable that influenced urinary 1-BP significantly. There was a close correlation between 1-BP in urine and 1-BP in air; the correlation coefficient (r) was >0.9 with a narrow variation range, and the regression line passed very close to the origin so that 2 ppm 1-BP exposure can be readily biomonitored. The correlation of Br in urine with 1-BP in air was also significant, but the r (about 0.7) was smaller than that for 1-BP, and the background Br level was also substantial (about 8 mg l-1). Thus, it was concluded that 1-BP in end-of-shift urine is a reliable biomarker of occupational exposure to 1-BP vapour, and that Br in urine is less reliable. |
| |
Keywords: | Biological Monitoring Bromide Ion L-BROMOPROPANE Diffusive Sampling Occupational Exposure Urinalysis |
本文献已被 InformaWorld 等数据库收录! |
|