首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Implementation and validation of thoracic side impact injury prediction metrics in a human body model
Authors:Adam J Golman  Kerry A Danelson  James P Gaewsky
Institution:1. Virginia Tech-Wake Forest University School of Biomedical Engineering and Sciences, Winston-Salem, NC, USA;2. Wake Forest University School of Medicine, 575 N. Patterson Ave., Suite 120, Winston-Salem, NC 27101, USA
Abstract:This study's purpose was to implement injury metrics into the Total Human Model for Safety (THUMS) mirroring the spinal accelerometers, rib accelerometers and chest band instrumentation from two lateral post-mortem human subject sled test configurations. In both sled configurations, THUMS contacted a flat rigid surface (either a wall or beam) at 6.7 m/s. Sled A maximum simulated wall forces for the thorax, abdomen and pelvis were 7.1, 5.0 and 10.0 kN versus 5.7 ± 0.8, 3.4 ± 1.2 and 6.2 ± 2.7 kN experimentally. Sled B maximum simulated beam forces for the torso and pelvis were 8.0 and 7.6 kN versus 8.5 ± 0.2 and 7.9 ± 2.5 kN experimentally. Quantitatively, force magnitude contributed more to variation between simulated and experimental forces than phase shift. Acceleration-based injury metrics were within one standard deviation of experimental means except for the lower spine in the rigid wall sled test. These validated metrics will be useful for quantifying occupant loading conditions and calculating injury risks in various loading configurations.
Keywords:human body modelling  finite element analysis  blunt impact trauma
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号