Basal Insulin Degludec and Glycemic Control Compared to Aspart Via Insulin Pump in Type 1 Diabetes (BIGLEAP): A Single-Center,Open-Label,Randomized, Crossover Trial
Authors:Wendy S Lane  Stephen L Weinrib  Michael J Lawrence  Benjamin C Lane  Ryan T Jarrett
Institution:1. Mountain Diabetes and Endocrine Center, Asheville, North Carolina;2. Department of Data Science, Vanderbilt University, Nashville, Tennessee;3. Department of Biostatistics, Vanderbilt University, Nashville, Tennessee
Abstract:ObjectiveWe compared the efficacy of the second-generation basal insulin degludec (IDeg) to that of insulin aspart via pump using continuous glucose monitoring in patients with well-controlled type 1 diabetes.MethodsIn this 40-week, single-center, randomized, crossover-controlled trial, adults with well-controlled type 1 diabetes (hemoglobin A1C of <7.5% <58 mmol/mol]) (N = 52) who were using an insulin pump and continuous glucose monitoring were randomized to 1 of 2 treatments for a 20-week period: a single daily injection of IDeg with bolus aspart via pump or a continuous subcutaneous insulin infusion (CSII) with aspart, followed by crossover to the other treatment. The primary endpoint was time in range (70-180 mg/dL) during the final 2 weeks of each treatment period.ResultsFifty-two patients were randomized and completed both treatment periods. The time in range for IDeg and CSII was 71.5% and 70.9%, respectively (P = .553). The time in level 1 hypoglycemia for the 24-hour period with IDeg and CSII was 2.19% and 1.75%, respectively (P = .065). The time in level 2 hypoglycemia for the 24-hour period with IDeg and CSII was 0.355% and 0.271%, respectively (P = .212), and the nocturnal period was 0.330% and 0.381%, respectively (P = .639). The mean standard deviation of blood glucose levels for the 24-hour period for IDeg and CSII was 52.4 mg/dL and 51.0 mg/dL, respectively (P = .294). The final hemoglobin A1C level for each treatment was 7.04% (53 mmol/mol) with IDeg, and 6.95% (52 mmol/mol) with CSII (P = .288). Adverse events were similar between treatments.ConclusionWe observed similar glycemic control between IDeg and insulin aspart via CSII for basal insulin coverage in patients with well-controlled type 1 diabetes.
Keywords:type 1 diabetes  insulin degludec  glycemic control  hypoglycemia  insulin pump therapy  continuous glucose monitoring  BG"}  {"#name":"keyword"  "$":{"id":"kwrd0045"}  "$$":[{"#name":"text"  "_":"blood glucose  CGM"}  {"#name":"keyword"  "$":{"id":"kwrd0055"}  "$$":[{"#name":"text"  "_":"continuous glucose monitoring  CI"}  {"#name":"keyword"  "$":{"id":"kwrd0065"}  "$$":[{"#name":"text"  "_":"confidence interval  CSII"}  {"#name":"keyword"  "$":{"id":"kwrd0075"}  "$$":[{"#name":"text"  "_":"continuous subcutaneous insulin infusion  HbA1C"}  {"#name":"keyword"  "$":{"id":"kwrd0085"}  "$$":[{"#name":"text"  "_":"hemoglobin A1C  IDeg"}  {"#name":"keyword"  "$":{"id":"kwrd0095"}  "$$":[{"#name":"text"  "_":"insulin degludec  MDI"}  {"#name":"keyword"  "$":{"id":"kwrd0105"}  "$$":[{"#name":"text"  "_":"multiple daily insulin injections  TIR"}  {"#name":"keyword"  "$":{"id":"kwrd0115"}  "$$":[{"#name":"text"  "_":"time in range
本文献已被 ScienceDirect 等数据库收录!