首页 | 本学科首页   官方微博 | 高级检索  
     


Grinding Microorganisms with a Peristaltic Pump
Authors:James W. Phillips   Carl Lamanna     M. F. Mallette
Abstract:The Randolph Co. model 610 peristaltic, ⅛-hp pump was effective for preparative purposes in disrupting baker's yeast and spores of Bacillus globigii when suspended with glass beads. Best results were obtained with use of a slurry just fluid enough to flow through tubing while stirred. Beads of 0.2 and 0.1 mm were used to best advantage for the yeast cells and spores, respectively. Yeast cells were disrupted completely within 15 min, and the spores in 10 to 30 min. Temperature and surface denaturation are readily controlled, and the system is easily modified for use with large quantities of microorganisms.