首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   54篇
  免费   20篇
  国内免费   7篇
  2023年   2篇
  2021年   1篇
  2019年   4篇
  2018年   4篇
  2017年   5篇
  2016年   9篇
  2015年   7篇
  2014年   4篇
  2013年   6篇
  2012年   1篇
  2011年   4篇
  2010年   1篇
  2009年   1篇
  2008年   6篇
  2007年   3篇
  2006年   4篇
  2005年   4篇
  2004年   2篇
  2003年   2篇
  2002年   5篇
  2001年   1篇
  2000年   2篇
  1999年   1篇
  1988年   1篇
  1979年   1篇
排序方式: 共有81条查询结果,搜索用时 15 毫秒
1.
In this work, the long‐term effects of transient chemical oxygen demands (COD) concentrations over the performance of a microbial fuel cell were studied. From the obtained results, it was observed that the repetitive change in the COD loading rate during 12 h conditioned the behavior of the system during periods of up to 7 days. The main modifications were the enhancement of the COD consumption rate and the exerted current. These enhancements yielded increasing Coulombic efficiencies (CEs) when working with COD concentrations of 300 mg/L, but constant CEs when working with COD concentrations from 900 to 1800 mg/L. This effect could be explained by the higher affinity for the substrate of Geobacter than that of the nonelectrogenic organisms such as Clostridia. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:883–890, 2016  相似文献   
2.
为比较研究不同质粒针对不同乳酸茵的电转效率的差异,分别以乳酸乳球菌NZ9000、干酪乳杆菌LC2W和植物乳杆菌WCFS1三种乳酸菌为受体,以七种不同质粒为载体,进行电转实验.结果表明在乳酸乳球菌NZ9000中,转化效率最高的是pIB 184质粒,达到了1.53×107 cfg/μgDNA,在干酪乳杆菌LC2W中,pSIP403质粒的电转化效率最高,达到了6.42×105 cfg/μgDNA,在植物乳杆菌WCFS1的电转化中,是pNZ44质粒达到8.68×105 cfg/μgDNA的最高转化效率.其中质粒pIB184和pNZ44在三种菌株中均有较高的电转化效率,超过了103 cfg/μgDNA,另一方面T-pAMS100、pSIP403、pSIP409三个质粒在干酪乳杆菌与植物乳杆菌中的电转化效率明显高于乳酸乳球菌.不同质粒针对不同乳酸茵的转化效率为乳酸茵的高效电转和表达栽体的选择与构建提供了可行依据.  相似文献   
3.
Stationary batteries are projected to play a role in the electricity system of Switzerland after 2030. By enabling the integration of surplus production from intermittent renewables, energy storage units displace electricity production from different sources and potentially create environmental benefits. Nevertheless, batteries can also cause substantial environmental impacts during their manufacturing process and through the extraction of raw materials. A prospective consequential life cycle assessment (LCA) of lithium metal polymer and lithium‐ion stationary batteries is undertaken to quantify potential environmental benefits and drawbacks. Projections are integrated into the LCA model: Energy scenarios are used to obtain marginal electricity supply mixes, and projections about the battery performances and the recycling process are sourced from the literature. The roles of key parameters and methodological choices in the results are systematically investigated. The results demonstrate that the displacement of marginal electricity sources determines the environmental implications of using batteries. In the reference scenario representing current policy, the displaced electricity mix is dominated by natural gas combined cycle units. In this scenario, the use of batteries generates environmental benefits in 12 of the 16 impact categories assessed. Nevertheless, there is a significant reduction in achievable environmental benefits when batteries are integrated into the power supply system in a low‐carbon scenario because the marginal electricity production, displaced using batteries, already has a reduced environmental impact. The direct impacts of batteries mainly originate from upstream manufacturing processes, which consume electricity and mining activities related to the extraction of materials such as copper and bauxite.  相似文献   
4.
A new one-compartment fuel cell was composed of a rubber bunged bottle with a center-inserted anode and a window-mounted cathode containing an internal, proton-permeable porcelain layer. This fuel cell design was less expensive and more practical than the conventional two-compartment system, which requires aeration and a ferricyanide solution in the cathode compartment. Three new electrodes containing bound electron mediators including a Mn(4+)-graphite anode, a neutral red (NR) covalently linked woven graphite anode, and an Fe(3+)-graphite cathode were developed that greatly enhanced electrical energy production (i.e., microbial electron transfer) over conventional graphite electrodes. The potentials of these electrodes measured by cyclic voltametry at pH 7.0 were (in volts): +0.493 (Fe(3+)-graphite); +0.15 (Mn(4+)-graphite); and -0.53 (NR-woven graphite). The maximal electrical productivities obtained with sewage sludge as the biocatalyst and using a Mn(4+)-graphite anode and a Fe(3+)-graphite cathode were 14 mA current, 0.45 V potential, 1,750 mA/m(2) current density, and 788 mW/m(2) of power density. With Escherichia coli as the biocatalyst and using a Mn(4+)-graphite anode and a Fe(3+)-graphite cathode, the maximal electrical productivities obtained were 2.6 mA current, 0.28 V potential, 325 mA/m(2) current density, and 91 mW/m(2) of power density. These results show that the amount of electrical energy produced by microbial fuel cells can be increased 1,000-fold by incorporating electron mediators into graphite electrodes. These results also imply that sewage sludge may contain unique electrophilic microbes that transfer electrons more readily than E. coli and that microbial fuel cells using the new Mn(4+)-graphite anode and Fe(3+)-graphite cathode may have commercial utility for producing low amounts of electrical power needed in remote locations.  相似文献   
5.
Uganda is rich in aquatic ecosystems. Commercial fishing involves an off‐take that may not be ultimately sustainable. Aquatic ecosystems, like the forests, are under pressure. Forests, for many years to come, will remain the main source of energy for the people. They also continue to be cleared to make way for agricultural use of the land. Research for development must address problems of this kind as they are at the heart of the development process.  相似文献   
6.
Goal and Scope This study estimates the life cycle inventory (LCI) of the electricity system in the United States, including the 10 NERC (North American Electric Reliability Council) regions, Alaska, Hawaii, off-grid non-utility plants and the US average figures. The greenhouse gas emissions associated with the United States electricity system are also estimated. Methods The fuel mix of the electricity system based on year 2000 data is used. The environmental burdens associated with raw material extraction, petroleum oil production and transportation for petroleum oil and natural gas to power plants are adopted from the DEAMTM LCA database. Coal transportation from a mining site to a power plant is specified with the data from the Energy Information Administration (EIA), which includes the mode of transportation as well as the distance traveled. The gate-to-gate environmental burdens associated with generating electricity from a fossil-fired power plant are obtained from the DEAMTM LCA database and the eGRID model developed by the United States Environmental Protection Agency. For nuclear power plants and hydroelectric power plants, the data from the DEAMTM LCA database are used.Results and Discussion Selected environmental profiles of the US electricity system are presented in the paper version, while the on-line version presents the whole LCI data. The overall US electricity system in the year 2000 released about 2,654 Tg CO2 eq. of greenhouse gas emissions based on 100-year global warming potentials with 193 g CO2 eq. MJe–1 as an weighted average emission rate per one MJ electricity generated. Most greenhouse gases are released during combusting fossil fuels, accounting for 78–95% of the total. The greenhouse gas emissions released from coal-fired power plants account for 81% of the total greenhouse gas emissions associated with electricity generation, and natural gas-fired power plants contribute about 16% of the total. The most significant regions for the total greenhouse gas emissions are the SERC (Southeastern Electric Reliability Council) and ECAR (East Central Area Reliability Coordination Agreement) regions, which account for 22% and 21% of the total, respectively. A sensitivity analysis on the generation and consumption based calculations indicates that the environmental profiles of electricity based on consumption are more uncertain than those based on generation unless exchange data from the same year are available because the exchange rates (region to region import and export of electricity) vary significantly from year to year.Conclusions and Outlook Those who are interested in the LCI data of the US electricity system can refer to the on-line version. When the inventory data presented in the on-line version are used in a life cycle assessment study, the distribution and transmission losses should be taken into account, which is about 9.5% of the net generation [1]. The comprehensive technical information presented in this study can be used in estimating the environmental burdens when new information on the regional fuel mix or the upstream processes is available. The exchange rates presented in this study also offer useful information in consequential LCI studies.  相似文献   
7.
高效毛细管电泳分离多种植物激素的方法研究   总被引:3,自引:0,他引:3  
建立了高效毛细管电泳法分离测定茶叶中赤霉素(GA)、吲哚-3-乙酸(IAA)、脱落酸(ABA)、吲哚-3-丁酸(IBA)、细胞分裂素(CTK)等5种植物激素的分析方法。采用正交试验设计对高效毛细管电泳方法中的运行电压、缓冲液pH值和添加剂SDS浓度等分离条件进行优化,结果发现在30 mmol/L H3BO4-KH2PO4、40 mmol/LSDS组成的pH9.0缓冲液中,选择18 kV电压,25℃柱温和200 nm波长,可在11 min以内实现茶叶中5种激素的分离检测。本方法具有较高的灵敏度,5种激素的相关系数r=0.9907~0.9974,加标回收率为78.06%-95.5%,变异系数≤1.8%。利用本方法测定了茶叶不同部位的5种植物激素的含量变化。  相似文献   
8.
Ammonia losses during swine wastewater treatment were examined using single- and two-chambered microbial fuel cells (MFCs). Ammonia removal was 60% over 5 days for a single-chamber MFC with the cathode exposed to air (air-cathode), versus 69% over 13 days from the anode chamber in a two-chamber MFC with a ferricyanide catholyte. In both types of systems, ammonia losses were accelerated with electricity generation. For the air-cathode system, our results suggest that nitrogen losses during electricity generation were increased due to ammonia volatilization with conversion of ammonium ion to the more volatile ammonia species as a result of an elevated pH near the cathode (where protons are consumed). This loss mechanism was supported by abiotic tests (applied voltage of 1.1 V). In a two-chamber MFC, nitrogen losses were primarily due to ammonium ion diffusion through the membrane connecting the anode and cathode chambers. This loss was higher with electricity generation as the rate of ammonium transport was increased by charge transfer across the membrane. Ammonia was not found to be used as a substrate for electricity generation, as intermittent ammonia injections did not produce power. The ammonia-oxidizing bacterium Nitrosomonas europaea was found on the cathode electrode of the single-chamber system, supporting evidence of biological nitrification, but anaerobic ammonia-oxidizing bacteria were not detected by molecular analyses. It is concluded that ammonia losses from the anode chamber were driven primarily by physical-chemical factors that are increased with electricity generation, although some losses may occur through biological nitrification and denitrification.  相似文献   
9.
10.
Publicly available databases are analysed to demonstrate their relevance to life cycle inventory for energy production in the Canadian context. Site specific emissions along with sectoral emissions data are combined with production data to construct an energy production model, which has been applied to air emissions. The allocation procedure leads to reasonable results for coal, natural gas and electricity. The detailed allocation of the inventory among petroleum co-products is outside the scope of this study as it requires incorporating knowledge of physical relationship (unit process) or using economic data.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号