首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   24篇
  免费   0篇
  2022年   2篇
  2021年   2篇
  2019年   3篇
  2018年   2篇
  2017年   4篇
  2016年   1篇
  2015年   1篇
  2014年   4篇
  2013年   1篇
  2009年   1篇
  2008年   1篇
  2006年   1篇
  1999年   1篇
排序方式: 共有24条查询结果,搜索用时 31 毫秒
1.
The purpose of this study was to investigate the function and importance of infrahyoid muscles with the suprahyoid muscles during swallowing, and to investigate swallowing sequences using kinematic analysis, high-resolution manometry (HRM) and electromyography (EMG). As a preliminary study, ten healthy subjects were prospectively enrolled. A needle EMG evaluated the onset latency, peak latency and duration of the suprahyoid and infrahyoid muscles. HRM measured the time intervals among the velopharynx, tongue base, and upper esophageal sphincter. We also evaluated hyoid motion using an automated kinematic analysis software® (AKAS). All of these parameters were synchronized with a tilting motion of the epiglottis. In the EMG analysis, the activations of the suprahyoid muscles developed about 300 ms earlier than that of the infrahyoid muscles. There was a significant relationship between the differences of suprahyoid and infrahyoid muscles’ latency and total duration of the hyoid motion (p < 0.05). The interval time of anterior hyoid motion has a significant correlation in the upper esophageal sphincter (UES) opening time. In conclusions, the functions of the infrahyoid muscles are also as important as that of the suprahyoid muscles for prolonged laryngeal elevation and UES opening. Moreover, kinematic analysis of videofluoroscopic swallowing study (VFSS) and HRM studies could reflect results of needle EMG study and replace EMG study.  相似文献   
2.
This study demonstrates the validity of using 3-D video motion analysis to measure hand motion. Several researchers have devised ingenious methods to study normal and abnormal hand movements. Although very helpful, these earlier studies are static representations of a dynamic phenomenon. Despite the many studies of hand motion using scientifically impeccable techniques, little is known about digital motion, and there are still few researchers investigating dynamic three-dimensional motion of the hand. Results from a three-camera video motion analysis system were compared to those from the “gold standard”, 2-D lateral view fluoroscopy. We used these two methods to record hand motion simultaneously during unrestricted flexion and extension of the index finger of the dominant hand in 6 neurologically normal, healthy volunteers. After collection and post-processing, the waveforms of the PIP, DIP and MCP joint angles were compared using the adjusted coefficient of multiple determination (R2a, or CMD). The mean CMD values for the MCP, PIP and DIP joint angle waveforms were 0.96, 0.98 and 0.94, respectively, suggesting a close similarity between motion of comparable joints analyzed by the 2-D and 3-D methods. This shows that the method of 3-D motion analysis is capable of accurately quantifying digital joint motion.

It is anticipated that 3-D motion analysis, in addition to being used as a research tool, will also have clinical applications such as surgical planning in neuromuscular disorders and the documentation of abnormal motion in many other pathological hand conditions.  相似文献   

3.
The use of massive bone allografts is increasing year by year and selection method remains unchanged. Superposition of patient’s radiograph over allograft image and comparison of distances is the gold standard. Experiment was led to test selection procedure of a major european tissue bank. Four observers were asked to select an allograft for 10 fictive recipients. Nine allografts were provided. To simulate a perfect allograft, recipient himself was inserted in the pool of allografts (trap graft). The 10 potential bone transplants were classified in four categories (from adequate to unacceptable). In addition, observers were asked to choose the three best grafts for a given recipient. Quadratic kappa measuring agreement on classification between two observers ranged between 0.74 (substantial) and 0.47 (moderate). Trap graft was quoted by observers as adequate four times (10%) and was cited eight times (20%) among the three best matching allografts. None of the observers discovered that recipient was among allograft panel. This study demonstrates that current selection method is inaccurate for hemipelvic allograft selection. New methods should be developed and tested to assist tissue banks in bone allograft selection.  相似文献   
4.
Accurate prediction of loads acting at the joint in total knee replacement (TKR) patients is key to developing experimental or computational simulations which evaluate implant designs under physiological loading conditions. In vivo joint loads have been measured for a small number of telemetric TKR patients, but in order to assess device performance across the entire patient population, a larger patient cohort is necessary. This study investigates the accuracy of predicting joint loads from joint kinematics. Specifically, the objective of the study was to assess the accuracy of internal–external (I–E) and anterior–posterior (A–P) joint load predictions from I–E and A–P motions under a given compressive load, and to evaluate the repeatability of joint load ratios (I–E torque to compressive force (I–E:C), and A–P force to compressive force (A–P:C)) for a range of compressive loading profiles. A tibiofemoral finite element model was developed and used to simulate deep knee bend, chair-rise and step-up activities for five patients. Root-mean-square (RMS) differences in I–E:C and A–P:C load ratios between telemetric measurements and model predictions were less than 1.10e–3 Nm/N and 0.035 N/N for all activities. I–E:C and A–P:C load ratios were consistently reproduced regardless of the compressive force profile applied (RMS differences less than 0.53e–3 Nm/N and 0.010 N/N, respectively). When error in kinematic measurement was introduced to the model, joint load predictions were forgiving to kinematic measurement error when conformity between femoral and tibial components was low. The prevalence of kinematic data, in conjunction with the analysis presented here, facilitates determining the scope of A–P and I–E joint loading ratios experienced by the TKR population.  相似文献   
5.
BackgroundCatheter ablation provides curative treatment for tachyarrhythmias. Fluoroscopy, the method used for this, presents several risks. The electroanatomical mapping (MEA) presents a three-dimensional image without using X-rays, and may be adjunct to fluoroscopy.ObjectivesWe evaluated the possibility of performing catheter ablation with the exclusive use of electroanatomical mapping (MEA), dispensing with fluoroscopy. We compared the total time of procedure and success rates against the technique using fluoroscopy (RX) with emission of X-rays.MethodsRandomized, unicentric, uni-blind study of patients referred for tachyarrhythmia ablation.ResultsTwelve patients were randomized to the XR group and 11 to the EAM group. The mean age was 48.5 (±12.6) vs 46.3 (±16.6) (P = ns). Success occurred in 11 patients (91.7%) in the RX group and 9 (81.8%) in the MEA group (P = 0.46). The procedure time in minutes was higher in the MEA group than in the RX group (79-47-125min vs 49-30-100min; P = 0.006). The mean fluoroscopy time was 11 ± 9 min versus zero (RX vs MEA: P < 0.001). The mean radiofrequency applications were lower in the RX group against the MEA group (6 ± 3.5 × 13.2 ± 18.2 p < 0.019). There were no complications.ConclusionMEA opened new therapeutic possibilities for patients with arrhythmias, reducing the risk of radiation. In this study, it was possible to demonstrate that it is feasible to perform ablation only with the use of MEA, with similar success with fluoroscopy, at the expense of a longer procedure time.  相似文献   
6.
Recent developments in cellular and molecular biology require the accurate quantification of DNA and RNA in large numbers of samples at a sensitivity that enables determination on small quantities. In this study, five current methods for nucleic acid quantification were compared: (i) UV absorbance spectroscopy at 260 nm, (ii) colorimetric reaction with orcinol reagent, (iii) colorimetric reaction based on diphenylamine, (iv) fluorescence detection with Hoechst 33258 reagent, and (v) fluorescence detection with thiazole orange reagent. Genomic DNA of three different microbial species (with widely different G+C content) was used, as were two different types of yeast RNA and a mixture of equal quantities of DNA and RNA. We can conclude that for nucleic acid quantification, a standard curve with DNA of the microbial strain under study is the best reference. Fluorescence detection with Hoechst 33258 reagent is a sensitive and precise method for DNA quantification if the G+C content is less than 50%. In addition, this method allows quantification of very low levels of DNA (nanogram scale). Moreover, the samples can be crude cell extracts. Also, UV absorbance at 260 nm and fluorescence detection with thiazole orange reagent are sensitive methods for nucleic acid detection, but only if purified nucleic acids need to be measured.  相似文献   
7.
Rollover crashes are dynamic and complex events in which head impacts with the roof can cause catastrophic neck injuries. Ex vivo and computational models are valuable in understanding, and ultimately preventing, these injuries. Although neck posture and muscle activity influence the resulting injury, there is currently no in vivo data describing these parameters immediately prior to a head-first impact. The specific objectives of this study were to determine the in vivo neck vertebral alignment and muscle activation levels when upside down, a condition that occurs during a rollover. Eleven human subjects (6F, 5M) were tested while seated upright and inverted in a custom-built apparatus. Vertebral alignment was measured using fluoroscopy and muscle activity was recorded using surface and indwelling electrodes in eight superficial and deep neck muscles. In vivo vertebral alignment and muscle activation levels differed between the upright and inverted conditions. When inverted and relaxed, the neck was more lordotic, C1 was aligned posterior to C7, the Frankfort plane was extended, and the activity of six muscles increased compared to upright and relaxed. When inverted subjects were asked to look forward to eliminate head extension, flexor muscle activity increased, C7 was more flexed, and C1 was aligned anterior to C7 versus upright and relaxed. Combined with the large inter-subject variability observed, these findings indicate that cadaveric or computational models designed to study injuries and prevention devices while inverted need to consider a variety of postures and muscle conditions to be relevant to the in vivo situation.  相似文献   
8.
Scapula and humerus motion associated with common manual wheelchair tasks is hypothesized to reduce the subacromial space. However, previous work relied on either marker-based motion capture for kinematic measures, which is prone to skin-motion artifact; or ultrasound imaging for arthrokinematic measures, which are 2D and acquired in statically-held positions. The aim of this study was to use a fluoroscopy-based approach to accurately quantify glenohumeral kinematics during manual wheelchair use, and compare tasks for a subset of parameters theorized to be associated with mechanical impingement. Biplane images of the dominant shoulder were acquired during scapular plane elevation, propulsion, sideways lean, and weight-relief raise in ten manual wheelchair users with spinal cord injury. A computed tomography scan of the shoulder was obtained, and model-based tracking was used to quantify six-degree-of-freedom glenohumeral kinematics. Axial rotation and superior/inferior and anterior/posterior humeral head positions were characterized for full activity cycles and compared between tasks. The change in the subacromial space was also determined for the period of each task defined by maximal change in the aforementioned parameters. Propulsion, sideways lean, and weight-relief raise, but not scapular plane elevation, were marked by mean internal rotation (8.1°, 10.8°, 14.7°, −49.2° respectively). On average, the humeral head was most superiorly positioned during the weight-relief raise (1.6 ± 0.9 mm), but not significantly different from the sideways lean (0.8 ± 1.1 mm) (p = 0.191), and much of the task was characterized by inferior translation. Scaption was the only task without a defined period of superior translation on average. Pairwise comparisons revealed no significant differences between tasks for anterior/posterior position (task means range: 0.1–1.7 mm), but each task exhibited defined periods of anterior translation. There was not a consistent trend across tasks between internal rotation, superior translation, and anterior translation with reductions in the subacromial space. Further research is warranted to determine the likelihood of mechanical impingement during these tasks based on the measured task kinematics and reductions in the subacromial space.  相似文献   
9.
Accurate knowledge of the dynamic knee motion in-vivo is instrumental for understanding normal and pathological function of the knee joint. However, interpreting motion of the knee joint during gait in other than the sagittal plane remains controversial. In this study, we utilized the dual fluoroscopic imaging technique to investigate the six-degree-of-freedom kinematics and condylar motion of the knee during the stance phase of treadmill gait in eight healthy volunteers at a speed of 0.67 m/s. We hypothesized that the 6DOF knee kinematics measured during gait will be different from those reported for non-weightbearing activities, especially with regards to the phenomenon of femoral rollback. In addition, we hypothesized that motion of the medial femoral condyle in the transverse plane is greater than that of the lateral femoral condyle during the stance phase of treadmill gait. The rotational motion and the anterior–posterior translation of the femur with respect to the tibia showed a clear relationship with the flexion–extension path of the knee during the stance phase. Additionally, we observed that the phenomenon of femoral rollback was reversed, with the femur noted to move posteriorly with extension and anteriorly with flexion. Furthermore, we noted that motion of the medial femoral condyle in the transverse plane was greater than that of the lateral femoral condyle during the stance phase of gait (17.4±2.0 mm vs. 7.4±6.1 mm, respectively; p<0.01). The trend was opposite to what has been observed during non-weightbearing flexion or single-leg lunge in previous studies. These data provide baseline knowledge for the understanding of normal physiology and for the analysis of pathological function of the knee joint during walking. These findings further demonstrate that knee kinematics is activity-dependent and motion patterns of one activity (non-weightbearing flexion or lunge) cannot be generalized to interpret a different one (gait).  相似文献   
10.
PurposeTo determine the radiation burden to infants undergoing voiding cystourethrography (VCUG) in a single institution and investigate the effect of shifting from analogue to digital imaging that allowed the use of a radiography-free examination protocol.MethodsAnthropometric and exposure data were prospectively collected for 35 consecutive infants undergoing VCUG on a digital system with a standardized examination protocol not including radiographs. Thermoluminescent dosimeters were used to determine entrance-skin dose. Monte Carlo simulations and patient-specific anthropomorphic phantoms were employed to determine organ/tissue doses and effective dose (ED). The associated theoretical risk of radiation-induced cancer was determined and compared to the nominal risk of cancer induction. The radiation burden from VCUG on a modern digital system with a contemporary examination protocol was compared to corresponding data reported previously for an analogue system in the same institution.ResultsThe median ED from VCUG was found 47 μSv. The associated total life attributable risk of radiation-induced cancer was found 10x10-6 and 13x10-6 for boys and girls, respectively. VCUG was found to increase the nominal risk of cancer by a factor of 1.000025 in boys and 1.000034 in girls. Shifting from analogue to digital imaging system resulted in 89% reduction of the radiation burden from VCUG.ConclusionThe theoretical radiation risks for infants undergoing VCUG using a modern digital imaging system and a radiography-free protocol were found to be minor. The transition from analogue to digital equipment resulted in considerable reduction of the radiation burden from VCUG.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号