首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   79篇
  免费   2篇
  2021年   1篇
  2017年   1篇
  2016年   5篇
  2015年   2篇
  2014年   3篇
  2013年   5篇
  2012年   4篇
  2011年   1篇
  2010年   2篇
  2009年   3篇
  2008年   3篇
  2007年   5篇
  2006年   2篇
  2005年   7篇
  2004年   2篇
  2003年   1篇
  2002年   6篇
  2001年   2篇
  2000年   4篇
  1999年   4篇
  1998年   1篇
  1992年   2篇
  1991年   3篇
  1990年   4篇
  1988年   5篇
  1987年   1篇
  1986年   1篇
  1985年   1篇
排序方式: 共有81条查询结果,搜索用时 312 毫秒
1.
Abstract

The Westland petrel (Procellaria westlandica) is an endemic New Zealand species and one of the very few burrowing seabird species still breeding on mainland New Zealand. It nests only on a series of coastal ridgelines near to Punakaiki on the West Coast of the South Island. Between 2002 and 2005, surveys were undertaken at 28 of the 29 known colonies. The area occupied by the colonies was 73 ha; most colonies had fewer than 50 burrows, but six colonies had 201–500 burrows and four colonies had more than 1000 burrows. We find that the current breeding range of Westland petrel and the location of individual colonies are similar to those reported in both the 1950s and 1970s. Based on total burrow counts at 28 colonies and burrow occupancy rates determined by annual monitoring, the annual breeding population is estimated to be between 2954 and 5137 breeding pairs.  相似文献   
2.

Background

Current techniques used to obtain lung samples have significant limitations and do not provide reproducible biomarkers of inflammation. We have developed a novel technique that allows multiple sampling methods from the same area (or multiple areas) of the lung under direct bronchoscopic vision. It allows collection of mucosal lining fluid and bronchial brushing from the same site; biopsy samples may also be taken. The novel technique takes the same time as standard procedures and can be conducted safely.

Methods

Eight healthy smokers aged 40–65 years were included in this study. An absorptive filter paper was applied to the bronchial mucosa under direct vision using standard bronchoscopic techniques. Further samples were obtained from the same site using bronchial brushings. Bronchoalveolar lavage (BAL) was obtained using standard techniques. Chemokine (C-C Motif) Ligand 20 (CCL20), CCL4, CCL5, Chemokine (C-X-C Motif) Ligand 1 (CXCL1), CXCL8, CXCL9, CXCL10, CXCL11, Interleukin 1 beta (IL-1β), IL-6, Vascular endothelial growth factor (VEGF), Matrix metalloproteinase 8 (MMP-8) and MMP-9 were measured in exudate and BAL. mRNA was collected from the bronchial brushings for gene expression analysis.

Results

A greater than 10 fold concentration of all the biomarkers was detected in lung exudate in comparison to BAL. High yield of good quality RNA with RNA integrity numbers (RIN) between 7.6 and 9.3 were extracted from the bronchial brushings. The subset of genes measured were reproducible across the samples and corresponded to the inflammatory markers measured in exudate and BAL.

Conclusions

The bronchoabsorption technique as described offers the ability to sample lung fluid direct from the site of interest without the dilution effects caused by BAL. Using this method we were able to successfully measure the concentrations of biomarkers present in the lungs as well as collect high yield mRNA samples for gene expression analysis from the same site. This technique demonstrates superior sensitivity to standard BAL for the measurement of biomarkers of inflammation. It could replace BAL as the method of choice for these measurements. This method provides a systems biology approach to studying the inflammatory markers of respiratory disease progression.

Trial registration

NHS Health Research Authority (13/LO/0256).  相似文献   
3.
The Ebola virus protein VP40 is a transformer protein that possesses an extraordinary ability to accomplish multiple functions by transforming into various oligomeric conformations. The disengagement of the C‐terminal domain (CTD) from the N‐terminal domain (NTD) is a crucial step in the conformational transformations of VP40 from the dimeric form to the hexameric form or octameric ring structure. Here, we use various molecular dynamics (MD) simulations to investigate the dynamics of the VP40 protein and the roles of interdomain interactions that are important for the domain–domain association and dissociation, and report on experimental results of the behavior of mutant variants of VP40. The MD studies find that various salt‐bridge interactions modulate the VP40 domain dynamics by providing conformational specificity through interdomain interactions. The MD simulations reveal a novel salt‐bridge between D45‐K326 when the CTD participates in a latch‐like interaction with the NTD. The D45‐K326 salt‐bridge interaction is proposed to help domain–domain association, whereas the E76‐K291 interaction is important for stabilizing the closed‐form structure. The effects of the removal of important VP40 salt‐bridges on plasma membrane (PM) localization, VP40 oligomerization, and virus like particle (VLP) budding assays were investigated experimentally by live cell imaging using an EGFP‐tagged VP40 system. It is found that the mutations K291E and D45K show enhanced PM localization but D45K significantly reduced VLP formation.  相似文献   
4.
5.
FISH probes are generally made out of BAC clones with genomic DNA containing a variable amount of repetitive DNA that will need to be removed or blocked for FISH analysis. To generate repeat free (RF) Probes without loss in genomic coverage, a random library is made from BAC clones by whole-genome amplification (WGA). Libraries are denatured in the presence of excess C(0)t-1 DNA and allowed to re-anneal followed by digestion of all double-stranded elements by duplex-specific nuclease (DSN). Selective amplification of all elements not containing repetitive sequences is realized by a sequential amplification. The final RF products can be re-amplified and used as a stock for future probe production. The RF probes have a lower background, the signal intensity build up is faster and there is no need for blocking DNA. The signal to background ratio of the RF was higher as compared to repeat containing probes.  相似文献   
6.
BACKGROUND: The prescence of circulating tumor cells (CTCs) in the peripheral blood of cancer patients and their frequency has been correlated with disease status. METHODS: In this study, CTCs were characterized by flow cytometry and fluorescence microscopy after immunomagnetic enrichment from 7.5-ml blood samples collected from patients with prostate cancer in evacuated blood-draw tubes that contained an anticoagulant and a preservative. Events were classified as tumor cell candidates if they expressed cytokeratin, lacked CD45, and stained with the nucleic acid dye 4,6-diamidino-2-phenylindole. RESULTS: In the blood of prostate cancer patients, only few of these events were intact cells. Other CTC events appeared as damaged cells or cell fragments by microscopy. By flow cytometry, these events stained variably with 4,6-diamidino-2-phenylindole and frequently expressed the apoptosis-induced, caspase-cleaved cytokeratin 18. Similar patterns of cell disintegration were observed when cells of the prostate line LNCaP were exposed to paclitaxel before spiking the cells into normal blood samples. CONCLUSIONS: The different observed stages of tumor cell degradation or apoptosis varied greatly between patients and were not found in blood of normal donors. Enumeration of CTCs and identification of CTCs undergoing apoptosis may provide relevant information to evaluate the response to therapy in cancer patients.  相似文献   
7.
BACKGROUND: A cell analysis system was developed to enumerate and differentiate magnetically aligned cells selected from whole blood. The cellular information extracted is similar to the readout of musical information from a compact disk (CD). Here we describe the optical design and data processing of the system. The performance of the system is demonstrated using fluorescent-labeled cells and beads. Materials and Methods System performance was demonstrated with 6-microm polystyrene beads labeled with magnetic nanoparticles and allophycocyanin (APC) and immunomagnetically aligned leukocytes, fluorescently labeled with Oxazine750 and CD4-APC, CD8-Cy5.5, and CD14-APC/Cy7 in whole blood. RESULTS: The sensitivity of the system was demonstrated using APC-labeled beads. With this system, beads containing 333 APC molecules could easily be resolved from the background. This level of sensitivity was not achievable with a commercial flow cytometer. A maximum of 20,000 immunomagnetically labeled cells could be aligned and analyzed in between 0.6 m of Ni lines, distributed over a surface area of 18 mm(2) and extracted from a blood volume that depended on the height of the chamber. The utility of the system was demonstrated by performing a three-color CD4-CD8-CD14 assay. CONCLUSIONS: We built a cell analysis system based on immunomagnetic cell selection and alignment and analysis of fluorescent signals employing CD-technology that is as good or better than current commercial analyzers. The cell analysis can be performed in whole blood or any other type of cell suspension without extensive sample preparation.  相似文献   
8.
BACKGROUND: Recently we introduced the CellTracks cell analysis system, in which samples are prepared based on a combination of immunomagnetic selection, separation, and alignment of cells along ferromagnetic lines. Here we describe the underlying magnetic principles and considerations made in the magnetic field design to achieve the best possible cell selection and alignment of magnetically labeled cells. Materials and Methods Computer simulations, in combination with experimental data, were used to optimize the design of the magnets and Ni lines to obtain the optimal magnetic configuration. RESULTS: A homogeneous cell distribution on the upper surface of the sample chamber was obtained with a magnet where the pole faces were tilted towards each other. The spatial distribution of magnetically aligned objects in between the Ni lines was dependent on the ratio of the diameter of the aligned object and the line spacing, which was tested with magnetically and fluorescently labeled 6 microm polystyrene beads. The best result was obtained when the line spacing was equal to or smaller than the diameter of the aligned object. CONCLUSIONS: The magnetic gradient of the designed permanent magnet extracts magnetically labeled cells from any cell suspension to a desired plane, providing a homogeneous cell distribution. In addition, it magnetizes ferro-magnetic Ni lines in this plane whose additional local gradient adds to the gradient of the permanent magnet. The resultant gradient aligns the magnetically labeled cells first brought to this plane. This combination makes it possible, in a single step, to extract and align cells on a surface from any cell suspension.  相似文献   
9.
Light scattering properties and antigen distribution of lymphocytes labeled with the monoclonal antibodies CD 5 and CD 20 were determined for 19 patients with a chronic B-cell derived leukaemia. The density of the antigen detected by the monoclonal antibody CD 5 appeared to be considerably lower on malignant B-lymphocytes of the patients as compared with T lymphocytes. A large variation was observed in the amount of receptors for the monoclonal antibodies CD 5 and CD 20 on the malignant cells of the different patients. B-cell chronic lymphocytic leukaemia (B-CLL) patients were clearly distinguishable from leukaemic follicular non Hodgkin lymphoma patients (LF-NHL, formerly lymphosarcoma cell leukaemia) and from a patient with a prolymphocytoid transformation (PLT) of the B-CLL according to the amount of the antigens for CD 5 and CD 20. Within the B-CLL patient population, no relation of progression of the disease with distribution of these antigens could be observed. In one patient the extraordinary phenotype CD 20+, CD 11+, leu 8+, CD 5- of the malignant lymphocytes was observed. An experimentally simple method to differentiate between the various chronic lymphocytic leukaemias (CLL) appeared to be the determination of orthogonal light scattering properties of lymphocytes. In healthy donors one can always distinguish two populations of lymphocytes in the orthogonal light scatter histograms. Lymphocytes of B-CLL patients show one uniform population with a relatively small orthogonal light scattering signal, lymphocytes of our patients with PLT of B-CLL or with LF-NHL show one uniform population with a relatively large orthogonal light scattering signal.  相似文献   
10.
The occurrence of cytotoxic lymphocyte subpopulations (i.e., CD 16+, CD 57+ and cytotoxic CD 8+) wa studied in the peripheral blood of 18 B-cell chronic lymphocytic leukemia (B-CLL) patients. The absolute numbers of CD 57+, CD 16+ and cytotoxic CD 8+ lymphocytes were increased in the peripheral blood of untreated patients as compared with healthy donors, suggesting a causal relation with the accumulation of malignant B-cells. For 5 B-CLL patients and 5 hematological normal donors, the lymphocyte subpopulations in peripheral blood, lymph nodes and bone marrow were determined. A significant immune response was observed in the lymph nodes of the patients, as reflected by the CD 3+ lymphocytes, which were 1.7-27 times larger in the patients lymph nodes than in their peripheral blood and bone marrow. In contrast, with peripheral blood this was mainly caused by an increase in CD 4+ lymphocytes. The CD 57 lymphocytes in the lymph nodes of the patients had abnormal orthogonal light-scattering signals and an abnormal density of CD 57+ receptors in comparison with their peripheral blood CD 57+ lymphocytes or the CD 57+ lymphocytes in the peripheral blood, bone marrow and tonsils of the hematological normal donors. This study shows that although a significant increase of cytotoxic lymphocytes in the peripheral blood of B-CLL patients is observed, the actual distributions of the non-malignant lymphocytes can be quite different at the actual tumor sites, i.e., bone marrow and lymph nodes.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号