首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   79篇
  免费   2篇
  2021年   1篇
  2017年   1篇
  2016年   5篇
  2015年   2篇
  2014年   3篇
  2013年   5篇
  2012年   4篇
  2011年   1篇
  2010年   2篇
  2009年   3篇
  2008年   3篇
  2007年   5篇
  2006年   2篇
  2005年   7篇
  2004年   2篇
  2003年   1篇
  2002年   6篇
  2001年   2篇
  2000年   4篇
  1999年   4篇
  1998年   1篇
  1992年   2篇
  1991年   3篇
  1990年   4篇
  1988年   5篇
  1987年   1篇
  1986年   1篇
  1985年   1篇
排序方式: 共有81条查询结果,搜索用时 234 毫秒
1.
L W Terstappen  D Johnson  R A Mickaels  J Chen  G Olds  J T Hawkins  M R Loken  J Levin 《Blood cells》1991,17(3):585-602; discussion 603-5
Forward light scattering, orthogonal light scattering, and the fluorescence intensities of unlysed peripheral blood cells, labeled with CD45-phycoerythrin and the nucleic acid dyes LDS-751 and thiazole orange, were measured simultaneously, utilizing a flow cytometer. Erythrocytes, reticulocytes, platelets, neutrophils, eosinophils, basophils, monocytes, lymphocytes, nucleated erythrocytes, and immature nucleated cells occupied unique positions in the five-dimensional space created by the listmode storage of the five independent parameters. A software program was developed which identified and enumerated each of these cell populations. Platelets in this study were identified by LDS-751 staining, in addition to their forward and orthogonal light-scattering characteristics. Validation of this approach was obtained by demonstrating that all CD41- or CD42-expressing platelets also stained with LDS-751. Furthermore, the staining by LDS-751 did not change following platelet activation with ADP. The quantification of erythrocytes, platelets, neutrophils, eosinophils, monocytes, and lymphocytes correlated well with data obtained with a commercial hematology whole blood analyzer (H-1). Reproducibility of the identification of these populations was shown by repeated measurement of the same sample and by staining and analysis of multiple aliquots of identical blood samples. Stability studies demonstrated that 8 hours after blood collection, the number of damaged cells increased. This could be measured by a greater thiazole orange uptake by the damaged cells. This investigation demonstrates the feasibility of multidimensional flow cytometric blood cell differentiation for an automated whole blood cell analysis without the necessity of erythrocyte lysis. The ability to simultaneously identify reticulocytes, nucleated erythrocytes, and immature nucleated cells in one measurement is unique and promises to be a powerful tool for the assessment of abnormal blood samples.  相似文献   
2.
Light scattering properties and antigen distribution of lymphocytes labeled with the monoclonal antibodies CD 5 and CD 20 were determined for 19 patients with a chronic B-cell derived leukaemia. The density of the antigen detected by the monoclonal antibody CD 5 appeared to be considerably lower on malignant B-lymphocytes of the patients as compared with T lymphocytes. A large variation was observed in the amount of receptors for the monoclonal antibodies CD 5 and CD 20 on the malignant cells of the different patients. B-cell chronic lymphocytic leukaemia (B-CLL) patients were clearly distinguishable from leukaemic follicular non Hodgkin lymphoma patients (LF-NHL, formerly lymphosarcoma cell leukaemia) and from a patient with a prolymphocytoid transformation (PLT) of the B-CLL according to the amount of the antigens for CD 5 and CD 20. Within the B-CLL patient population, no relation of progression of the disease with distribution of these antigens could be observed. In one patient the extraordinary phenotype CD 20+, CD 11+, leu 8+, CD 5- of the malignant lymphocytes was observed. An experimentally simple method to differentiate between the various chronic lymphocytic leukaemias (CLL) appeared to be the determination of orthogonal light scattering properties of lymphocytes. In healthy donors one can always distinguish two populations of lymphocytes in the orthogonal light scatter histograms. Lymphocytes of B-CLL patients show one uniform population with a relatively small orthogonal light scattering signal, lymphocytes of our patients with PLT of B-CLL or with LF-NHL show one uniform population with a relatively large orthogonal light scattering signal.  相似文献   
3.
BACKGROUND: The prescence of circulating tumor cells (CTCs) in the peripheral blood of cancer patients and their frequency has been correlated with disease status. METHODS: In this study, CTCs were characterized by flow cytometry and fluorescence microscopy after immunomagnetic enrichment from 7.5-ml blood samples collected from patients with prostate cancer in evacuated blood-draw tubes that contained an anticoagulant and a preservative. Events were classified as tumor cell candidates if they expressed cytokeratin, lacked CD45, and stained with the nucleic acid dye 4,6-diamidino-2-phenylindole. RESULTS: In the blood of prostate cancer patients, only few of these events were intact cells. Other CTC events appeared as damaged cells or cell fragments by microscopy. By flow cytometry, these events stained variably with 4,6-diamidino-2-phenylindole and frequently expressed the apoptosis-induced, caspase-cleaved cytokeratin 18. Similar patterns of cell disintegration were observed when cells of the prostate line LNCaP were exposed to paclitaxel before spiking the cells into normal blood samples. CONCLUSIONS: The different observed stages of tumor cell degradation or apoptosis varied greatly between patients and were not found in blood of normal donors. Enumeration of CTCs and identification of CTCs undergoing apoptosis may provide relevant information to evaluate the response to therapy in cancer patients.  相似文献   
4.
The occurrence of cytotoxic lymphocyte subpopulations (i.e., CD 16+, CD 57+ and cytotoxic CD 8+) wa studied in the peripheral blood of 18 B-cell chronic lymphocytic leukemia (B-CLL) patients. The absolute numbers of CD 57+, CD 16+ and cytotoxic CD 8+ lymphocytes were increased in the peripheral blood of untreated patients as compared with healthy donors, suggesting a causal relation with the accumulation of malignant B-cells. For 5 B-CLL patients and 5 hematological normal donors, the lymphocyte subpopulations in peripheral blood, lymph nodes and bone marrow were determined. A significant immune response was observed in the lymph nodes of the patients, as reflected by the CD 3+ lymphocytes, which were 1.7-27 times larger in the patients lymph nodes than in their peripheral blood and bone marrow. In contrast, with peripheral blood this was mainly caused by an increase in CD 4+ lymphocytes. The CD 57 lymphocytes in the lymph nodes of the patients had abnormal orthogonal light-scattering signals and an abnormal density of CD 57+ receptors in comparison with their peripheral blood CD 57+ lymphocytes or the CD 57+ lymphocytes in the peripheral blood, bone marrow and tonsils of the hematological normal donors. This study shows that although a significant increase of cytotoxic lymphocytes in the peripheral blood of B-CLL patients is observed, the actual distributions of the non-malignant lymphocytes can be quite different at the actual tumor sites, i.e., bone marrow and lymph nodes.  相似文献   
5.
Abstract

The Westland petrel (Procellaria westlandica) is an endemic New Zealand species and one of the very few burrowing seabird species still breeding on mainland New Zealand. It nests only on a series of coastal ridgelines near to Punakaiki on the West Coast of the South Island. Between 2002 and 2005, surveys were undertaken at 28 of the 29 known colonies. The area occupied by the colonies was 73 ha; most colonies had fewer than 50 burrows, but six colonies had 201–500 burrows and four colonies had more than 1000 burrows. We find that the current breeding range of Westland petrel and the location of individual colonies are similar to those reported in both the 1950s and 1970s. Based on total burrow counts at 28 colonies and burrow occupancy rates determined by annual monitoring, the annual breeding population is estimated to be between 2954 and 5137 breeding pairs.  相似文献   
6.
7.
BACKGROUND: Circulating tumor cells (CTCs) in patients with carcinomas are extremely rare. In metastatic breast cancer, the presence of >or=5 CTCs in 7.5 ml of blood has been associated with short survival. As this threshold has clinical implications, it is important to recognize the limitations associated with the detection and enumeration of CTCs. METHODS: Statistical analyses were performed on data generated from a multi-center clinical trial that utilized the CellSearchtrade mark System to isolate and enumerate CTCs in 7.5 ml blood samples. The statistical issues associated with each step of the process, from blood collection to final image analysis and CTC enumeration, were determined and implemented into a model. RESULTS: A model describing the statistics of the different process steps that are needed for the isolation and detection of CTCs was developed. The model uses the Poisson distribution for blood collection and empirically determined distributions for the isolation and identification of CTCs. The variability between readers was identified as one of the main sources of errors responsible for the current threshold level of five CTCs. CONCLUSIONS: Elimination of the errors made in the identification of tumor cells isolated from 7.5 ml of blood could potentially reduce the CTC threshold for the identification of patients with a poor prognosis from the current value of five CTCs to one CTC per 7.5 ml of blood.  相似文献   
8.

Background

Patients with acute exacerbation of chronic obstructive pulmonary disease (COPD) commonly require hospitalization and admission to intensive care unit (ICU). It is useful to identify patients at the time of admission who are likely to have poor outcome. This study was carried out to define the predictors of mortality in patients with acute exacerbation of COPD and to device a scoring system using the baseline physiological variables for prognosticating these patients.

Methods

Eighty-two patients with acute respiratory failure secondary to COPD admitted to medical ICU over a one-year period were included. Clinical and demographic profile at the time of admission to ICU including APACHE II score and Glasgow coma scale were recorded at the time of admission to ICU. In addition, acid base disorders, renal functions, liver functions and serum albumin, were recorded at the time of presentation. Primary outcome measure was hospital mortality.

Results

Invasive ventilation was required in 69 patients (84.1%). Fifty-two patients survived to hospital discharge (63.4%). APACHE II score at the time of admission to ICU {odds ratio (95 % CI): 1.32 (1.138–1.532); p < 0.001} and serum albumin (done within 24 hours of admission) {odds ratio (95 % CI): 0.114 (0.03-0.432); p = 0.001}. An equation, constructed using the adjusted odds ratio for the two parameters, had an area under the ROC curve of 91.3%. For the choice of cut-off, sensitivity, specificity, positive and negative predictive value for predicting outcome was 90%, 86.5%, 79.4% and 93.7%.

Conclusion

APACHE II score at admission and SA levels with in 24 hrs after admission are independent predictors of mortality for patients with COPD admitted to ICU. The equation derived from these two parameters is useful for predicting outcome of these patients.  相似文献   
9.
BACKGROUND: Recently we introduced the CellTracks cell analysis system, in which samples are prepared based on a combination of immunomagnetic selection, separation, and alignment of cells along ferromagnetic lines. Here we describe the underlying magnetic principles and considerations made in the magnetic field design to achieve the best possible cell selection and alignment of magnetically labeled cells. Materials and Methods Computer simulations, in combination with experimental data, were used to optimize the design of the magnets and Ni lines to obtain the optimal magnetic configuration. RESULTS: A homogeneous cell distribution on the upper surface of the sample chamber was obtained with a magnet where the pole faces were tilted towards each other. The spatial distribution of magnetically aligned objects in between the Ni lines was dependent on the ratio of the diameter of the aligned object and the line spacing, which was tested with magnetically and fluorescently labeled 6 microm polystyrene beads. The best result was obtained when the line spacing was equal to or smaller than the diameter of the aligned object. CONCLUSIONS: The magnetic gradient of the designed permanent magnet extracts magnetically labeled cells from any cell suspension to a desired plane, providing a homogeneous cell distribution. In addition, it magnetizes ferro-magnetic Ni lines in this plane whose additional local gradient adds to the gradient of the permanent magnet. The resultant gradient aligns the magnetically labeled cells first brought to this plane. This combination makes it possible, in a single step, to extract and align cells on a surface from any cell suspension.  相似文献   
10.
BACKGROUND: A cell analysis system was developed to enumerate and differentiate magnetically aligned cells selected from whole blood. The cellular information extracted is similar to the readout of musical information from a compact disk (CD). Here we describe the optical design and data processing of the system. The performance of the system is demonstrated using fluorescent-labeled cells and beads. Materials and Methods System performance was demonstrated with 6-microm polystyrene beads labeled with magnetic nanoparticles and allophycocyanin (APC) and immunomagnetically aligned leukocytes, fluorescently labeled with Oxazine750 and CD4-APC, CD8-Cy5.5, and CD14-APC/Cy7 in whole blood. RESULTS: The sensitivity of the system was demonstrated using APC-labeled beads. With this system, beads containing 333 APC molecules could easily be resolved from the background. This level of sensitivity was not achievable with a commercial flow cytometer. A maximum of 20,000 immunomagnetically labeled cells could be aligned and analyzed in between 0.6 m of Ni lines, distributed over a surface area of 18 mm(2) and extracted from a blood volume that depended on the height of the chamber. The utility of the system was demonstrated by performing a three-color CD4-CD8-CD14 assay. CONCLUSIONS: We built a cell analysis system based on immunomagnetic cell selection and alignment and analysis of fluorescent signals employing CD-technology that is as good or better than current commercial analyzers. The cell analysis can be performed in whole blood or any other type of cell suspension without extensive sample preparation.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号