全文获取类型
收费全文 | 165篇 |
免费 | 11篇 |
国内免费 | 1篇 |
出版年
2021年 | 1篇 |
2018年 | 1篇 |
2017年 | 1篇 |
2015年 | 4篇 |
2014年 | 4篇 |
2013年 | 3篇 |
2012年 | 9篇 |
2011年 | 4篇 |
2010年 | 7篇 |
2009年 | 13篇 |
2008年 | 6篇 |
2007年 | 6篇 |
2006年 | 11篇 |
2005年 | 8篇 |
2004年 | 10篇 |
2003年 | 8篇 |
2002年 | 3篇 |
2001年 | 12篇 |
2000年 | 8篇 |
1999年 | 3篇 |
1998年 | 3篇 |
1996年 | 3篇 |
1995年 | 3篇 |
1993年 | 4篇 |
1992年 | 8篇 |
1991年 | 3篇 |
1990年 | 4篇 |
1989年 | 4篇 |
1988年 | 3篇 |
1987年 | 1篇 |
1986年 | 2篇 |
1985年 | 4篇 |
1983年 | 1篇 |
1982年 | 2篇 |
1980年 | 3篇 |
1979年 | 5篇 |
1978年 | 2篇 |
排序方式: 共有177条查询结果,搜索用时 15 毫秒
1.
Summary The use of reticulated polyurethane foam as a support material for the immobilization of methanogenic associations and its application to the anaerobic treatment of fine particulate solid wastes was investigated. The colonization of polyurethane support particles in a continuous upflow reactor fed on a mixture of acetate, propionate and butyrate, was both rapid and dense. The combination of rumen microorganisms and colonized support particles in a two-phase digester resulted in an efficient anaerobic decomposition of papermill sludge. 相似文献
2.
H B Beverloo A van Schadewijk J Bonnet R van der Geest R Runia N P Verwoerd J Vrolijk J S Ploem H J Tanke 《Cytometry》1992,13(6):561-570
The preparation of charge-stabilized suspensions of small phosphor particles (0.1-0.3 micron) and their coupling with antibodies to immunoreactive conjugates is described. Phosphor particles consisting of yttriumoxisulfide activated with europium served as a model system in the evaluation of the stabilizing properties of several polycarboxylic acids. The optimal reagents were then applied to other phosphors which differ in spectral characteristics as well as in luminescence lifetime. These phosphors were ground to a size of 0.1-0.3 micron and proteins or other macromolecules were adsorbed to the phosphor particles to prepare conjugates of different physico-chemical properties. A time-resolved microscope, suitable for real time visualization of the time-delayed luminescence of the immunophosphors by the human eye, is described in detail. Since most phosphors require excitation with far UV light, a special fluorescence microscope allowing far UV excitation was developed for conventional visualization of the luminescence emitted by the phosphor. The possibility of multiple color labeling using various phosphor conjugates was demonstrated in a model system consisting of haptenized latex beads. 相似文献
3.
A model has been developed to simulate the parallel channels of muscle spindles and their monosynaptic connections to a homonymous motoneuron in the turtle. Input to the model is muscle length and stimulation, output is motoneuronal membrane potential. Quality of transmission is greatly dependent upon dispersive properties of the system. The contributions of different dispersive features are compared and also cumulative effects are considered. Reference is made to conditions which are found in actual movements. 相似文献
4.
Changes in erythropoiesis due to radiation or chemotherapy as studied by flow cytometric determination of peripheral blood reticulocytes 总被引:1,自引:0,他引:1
H J Tanke P H van Vianen F M Emiliani I Neuteboom N de Vogel A D Tates E A de Bruijn A T van Oosterom 《Histochemistry》1986,84(4-6):544-548
Flow cytometric determination of time dependent changes of numbers of reticulocytes in peripheral blood were investigated as a parameter for changes in erythropoiesis induced by radiation- or chemotherapy. Rats irradiated or treated with drugs (such as e.g. cyclophosphamide 100 mg/kg, vincristin 0.2 mg/kg, or mitomycin C 1.0 mg/kg) showed clear changes in erythropoietic activity. Reticulocyte numbers decreased rapidly until day 3-4 after treatment; this period was followed by a gradual increase and normal control values were seen at day 8-11. Radiation effects of doses as low 0.5 Gy could be detected in such a way. Similar studies were performed with patients with ovarian tumors treated with cis-platinum, a drug that may cause non-immune haemolysis. During prolonged treatment some patients showed increasing numbers of reticulocytes, measured at the first day of each hospitalization period, whereas leucocyte and platelet counts stayed more or less constant. Increasing numbers of reticulocytes generally indicates stimulation of erythropoietic activity of the bone marrow (due to increased blood loss); in this study increasing numbers often preceeded a decrease in hemoglobin values later on. Flow cytometric analysis of reticulocytes is therefore a potentially useful tool to detect changes in erythropoiesis, and considered more sensitive for the early recognition of patients that develop anemia, than hemoglobin measurements only. 相似文献
5.
I. Cornelese-ten Velde J. Wiegant H. J. Tanke J. S. Ploem 《Histochemistry and cell biology》1989,92(2):153-160
Summary Reflection contrast microscopy (RCM) is a sensitive tool to detect minor amounts of precipitated diaminobenzidine (DABox) in immunoperoxidase stained specimens. One of the main issues in immunocytochemistry is the ongoing need for more sensitive and quantitative techniques. Therefore we applied RCM, using a new simple model system, to methods previously described for increased sensitivity in immunocytochemistry with bright field microscopy. Addition of imidazole was found the most sensitive method and addition of Nickel and Cobalt ions gave the most enhanced colour intensity. Variation of the enzyme reaction parameters yielded a continuous increase in reflection with time. This was then discussed in view of other model studies of peroxidase kinetics. A quantitative relationship between the amount of peroxidase and the reflection of DABox was observed, indicating that quantitative immunoperoxidase studies with RCM are feasible.In situ hybridization (ISH) was then used as a useful biological model for RCM to test the optimal conditions for DAB staining found in the model system (high concentrations of DAB and peroxidase and 2 h incubation time). There was no background staining in the model system, also after prolonged incubation time. The ISH experiments showed that the contrast (ratio) between specific signal and chromosome background did not increase in time, whereas only the use of high avPO concentrations yielded the highest contrast. 相似文献
6.
The relevant microscopical conditions for the optimal visualization of ratio-color FISH stained cells were investigated. Special attention was given to the influence of the type of illumination, (semi)-critical vs. K?hler type illumination, in combination with the use of multi-band excitation and emission filters, on the registration of the colors of ratio labelled probes. Due to chromatic errors, many collecting lenses were found to cause a wavelength dependent excitation pattern with critical illumination. This resulted in a change of the observed color of microscopic objects when stained with a mixture of two dyes and excited with a dual band pass filter. A quantitative study of this effect for semi-critical illumination of FISH ratio-labelled chromosomes revealed a difference of 20% between highest and lowest ratio values depending on the position of the object in the microscopic field vs. only 2.5% for K?hler type of illumination. The impact of these errors on the identification of ratio-labelled probes and on the sensitivity of comparative genomic hybridization (CGH) to detect gene amplifications or losses is discussed. Standard preparations consisting of solutions of defined mixtures of fluorescent dyes or objects stained with defined ratios of fluorophores, are proposed to correct for the errors observed. 相似文献
7.
A M van Driel-Kulker J J Ploem-Zaaijer M van der Zwan-van der Zwan H J Tanke 《Analytical and quantitative cytology》1980,2(4):243-246
Quantitative cytology requires highly standardized preparation, fixation and staining techniques in order to obtain reproducible morphology (e.g., cell size, cell shape and chromatin distribution). We found centrifugal cytology best suited to this purpose. Therefore, we recently developed an improved bucket for centrifugation that permits sedimentation of cells in a fixative solution (2% polyethylene glycol in 50% ethanol) by using centrifugation at relatively high g forces. The cell quantity, the cell distribution and the flatness of the specimens thus prepared proved to be adequate for automated anlysis using the Leyden Television Analysis System (LEYTAS). Furthermore, different cytochemical and cytomorphologic staining procedures could be performed on different aliquots of the same cytologic sample without any change in the preparation or fixation technique. 相似文献
8.
The specificity and quantitative reliability of the Feulgen-acriflavine-SO2 procedure was tested on polyacrylamide model films containing DNA. Noncovalent binding of acriflavine to DNA was observed when the washing procedure, as used in the classical way, was applied. The noncovalently bound acriflavine could be removed with an extra wash in acid-ethanol. The presence of SO2 in the staining solution has been found to enhance covalent binding significantly. The absorbance of films stained by our Feulgen-acriflavine-SO2 procedure is directly proportional to that obtained by the classical Feulgen-pararosanilline-SO2 procedure. The acriflavine-Feulgen procedure has also been tested using a commercial and a purified dye. The use of purified acriflavine, compared to a commercial sample did not result in a significant difference in the maximum absorbance value of stained DNA nor in the absorption or the fluorescence emission spectra of acriflavin covalently bound to DNA. 相似文献
9.
C J Cornelisse H J Tanke H de Koning G B de la Riviere 《Analytical and quantitative cytology》1983,5(3):173-183
Two different flow cytometric procedures were applied on cell samples from human breast tumors. One procedure involved DNA ploidy analysis on suspensions of isolated nuclei. The mean ploidy ratios of 27 benign breast lesions to chicken erythrocytes and rainbow trout erythrocytes were found to be 2.66 +/- 0.03 and 1.25 +/- 0.02, respectively. From the 45 stemlines found in a series of 43 carcinomas, 12 were diploid, 13 hyperdiploid and 20 near-tetraploid. No association was found between the lymph node status and the DNA ploidy level. The second procedure involved sorting fixed cells from DNA "windows" for the preparation of permanent cytologic specimens. The sorted cells appeared to be shrunken, but the morphologic quality was similar to that of imprint specimens from the same tumors, permitting discrimination between various types of normal cells and tumor cells. The combined use of both flow cytometric procedures may lead to greater insight into the relationship between the cytologic and cytogenetic heterogeneity of breast carcinomas. 相似文献
10.