首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   17篇
  免费   2篇
  2023年   1篇
  2021年   1篇
  2020年   1篇
  2015年   6篇
  2013年   2篇
  2012年   1篇
  2011年   2篇
  2010年   1篇
  2007年   1篇
  2005年   1篇
  2002年   1篇
  1990年   1篇
排序方式: 共有19条查询结果,搜索用时 15 毫秒
1.
Indirect evidence has suggested that the Msh2-Msh6 mispair-binding complex undergoes conformational changes upon binding of ATP and mispairs, resulting in the formation of Msh2-Msh6 sliding clamps and licensing the formation of Msh2-Msh6-Mlh1-Pms1 ternary complexes. Here, we have studied eight mutant Msh2-Msh6 complexes with defective responses to nucleotide binding and/or mispair binding and used them to study the conformational changes required for sliding clamp formation and ternary complex assembly. ATP binding to the Msh6 nucleotide-binding site results in a conformational change that allows binding of ATP to the Msh2 nucleotide-binding site, although ATP binding to the two nucleotide-binding sites appears to be uncoupled in some mutant complexes. The formation of Msh2-Msh6-Mlh1-Pms1 ternary complexes requires ATP binding to only the Msh6 nucleotide-binding site, whereas the formation of Msh2-Msh6 sliding clamps requires ATP binding to both the Msh2 and Msh6 nucleotide-binding sites. In addition, the properties of the different mutant complexes suggest that distinct conformational states mediated by communication between the Msh2 and Msh6 nucleotide-binding sites are required for the formation of ternary complexes and sliding clamps.  相似文献   
2.
3.
Hybrid quadrupole time-of-flight (QTOF) mass spectrometry is one of the two major principles used in proteomics. Although based on simple fundamentals, it has over the last decades greatly evolved in terms of achievable resolution, mass accuracy, and dynamic range. The Bruker impact platform of QTOF instruments takes advantage of these developments and here we develop and evaluate the impact II for shotgun proteomics applications. Adaption of our heated liquid chromatography system achieved very narrow peptide elution peaks. The impact II is equipped with a new collision cell with both axial and radial ion ejection, more than doubling ion extraction at high tandem MS frequencies. The new reflectron and detector improve resolving power compared with the previous model up to 80%, i.e. to 40,000 at m/z 1222. We analyzed the ion current from the inlet capillary and found very high transmission (>80%) up to the collision cell. Simulation and measurement indicated 60% transfer into the flight tube. We adapted MaxQuant for QTOF data, improving absolute average mass deviations to better than 1.45 ppm. More than 4800 proteins can be identified in a single run of HeLa digest in a 90 min gradient. The workflow achieved high technical reproducibility (R2 > 0.99) and accurate fold change determination in spike-in experiments in complex mixtures. Using label-free quantification we rapidly quantified haploid against diploid yeast and characterized overall proteome differences in mouse cell lines originating from different tissues. Finally, after high pH reversed-phase fractionation we identified 9515 proteins in a triplicate measurement of HeLa peptide mixture and 11,257 proteins in single measurements of cerebellum—the highest proteome coverage reported with a QTOF instrument so far.Building on the fundamental advance of the soft ionization techniques electrospray ionization and matrix-assisted laser desorption/ionization (1, 2), MS-based proteomics has advanced tremendously over the last two decades (36). Bottom-up, shotgun proteomics is usually performed in a liquid chromatography-tandem MS (LC-MS/MS)1 format, where nanoscale liquid chromatography is coupled through electrospray ionization to an instrument capable of measuring a mass spectrum and fragmenting the recognized precursor peaks on the chromatographic time scale. Fundamental challenges of shotgun proteomics include the very large numbers of peptides that elute over relatively short periods and peptide abundances that vary by many orders of magnitude. Developments in mass spectrometers toward higher sensitivity, sequencing speed, and resolution were needed and helped to address these critical challenges (7, 8). Especially the introduction of the Orbitrap mass analyzers has advanced the state of the art of the field because of their very high resolution and mass accuracy (9, 10). A popular configuration couples a quadrupole mass filter for precursor selection to the Orbitrap analyzer in a compact benchtop format (1113).In addition to the improvements in MS instrumentation, there have been key advances in the entire proteomics workflow, from sample preparation through improved LC systems and in computational proteomics (1416). Together, such advances are making shotgun proteomics increasingly comprehensive and deep analyses can now be performed in a reasonable time (13, 1719). Nevertheless, complete analysis of all expressed proteins in a complex system remains extremely challenging and complete measurement of all the peptides produced in shotgun proteomics may not even be possible in principle (20, 21). Therefore, an urgent need for continued improvements in proteomics technology remains.Besides the Orbitrap analyzer and other ion trap technologies, the main alternative MS technology is time-of-flight, a technology that has been used for many decades in diverse fields. The configuration employed in proteomics laboratories combines a quadrupole mass filter via a collision cell and orthogonal acceleration unit to a reflectron and a multichannel plate (MCP) detector (22). TOF scans are generated in much less than a millisecond (ms), and a number of these “pulses” are added to obtain an MS or MS/MS spectrum with the desired signal to noise ratio. Our own laboratory has used such a quadrupole time-of-flight (QTOF) instrument as the main workhorse in proteomics for many years, but then switched to high-resolution trapping instruments because of their superior resolution and mass accuracy. However, TOF technology has fundamental attractions, such as the extremely high scan speed and the absence of space charge, which limits the number of usable ions in all trapping instruments. In principle, the high spectra rate makes TOF instruments capable of making use of the majority of ions, thus promising optimal sensitivity, dynamic range and hence quantification. It also means that TOF can naturally be interfaced with ion mobility devices, which typically separate ions on the ms time scale. Data independent analysis strategies such as MSE, in which all precursors are fragmented simultaneously (23, 24) or SWATH, in which the precursor ion window is rapidly cycled through the entire mass range (25), also make use of the high scanning speed offered by QTOF instruments. It appears that QTOFs are set to make a comeback in proteomics with recent examples showing impressive depth of coverage of complex proteomes. For instance, using a variant of the MSE method, identification of 5468 proteins was reported in HeLa cells in single shots and small sample amounts (26). In another report, employing ion mobility for better transmission of fragment ions to the detector led to the identification of up to 7548 proteins in human ovary tissue (27).In this paper, we describe the impact II™, a benchtop QTOF instrument from Bruker Daltonics, and its use in shotgun proteomics. This QTOF instrument is a member of an instrument family first introduced in 2008, which consists of the compact, the impact, and the maXis. The original impact was introduced in 2011 and was followed by the impact HD, which was equipped with a better digitizer, expanding the dynamic range of the detector. With the impact II, which became commercially available in 2014, we aimed to achieve a resolution and sequencing speed adequate for demanding shotgun proteomics experiments. To achieve this we developed an improved collision cell, orthogonal accelerator scheme, reflectron, and detector. Here we measure ion transmission characteristics of this instrument and the actually realized resolution and mass accuracy in typical proteomics experiments. Furthermore, we investigated the attainable proteome coverage in single shot analysis and we ask if QTOF performance is now sufficient for very deep characterization of complex cell line and tissue proteomes.  相似文献   
4.
5.
6.
Isolation of Brazilian marine fungi capable of growing on DDD pesticide   总被引:1,自引:0,他引:1  
The fungi Aspergillus sydowii Ce15, Aspergillus sydowii Ce19, Aspergillus sydowii Gc12, Bionectria sp. Ce5, Penicillium miczynskii Gc5, Penicillium raistrickii Ce16 and Trichoderma sp. Gc1, isolated from marine sponges Geodia corticostylifera and Chelonaplysylla erecta, were evaluated for their ability to grow in the presence of DDD pesticide. Increasing concentrations of DDD pesticide, i.e., 5.0 mg (1.56 × 10−12 mmol), 10.0 mg (3.12 × 10−2 mmol) and 15.0 mg (4.68 × 10−2 mmol) in solid and liquid culture media were tested. The fungi Trichoderma sp. Gc1 and Penicillium miczynskii Gc5 were able to grow in the presence of up to 15.0 mg of DDD, suggesting their potential for biodegradation. A 100% degradation of DDD was attained in liquid culture medium when Trichoderma sp. Gc1 was previously cultivated for 5 days and supplemented with 5.0 mg of DDD in the presence of hydrogen peroxide. However, the quantitative analysis showed that DDD was accumulated on mycelium and biodegradation level reached a maximum value of 58% after 14 days.  相似文献   
7.
8.
We aimed to characterize and investigate the antibacterial potential of the native stingless bees geopropolis volatile oils (VO) for the search of potentially new bioactive compounds. Geopropolis samples from Melipona bicolor schencki, M. compressipes manaosensis, M. fasciculata, M. quadrifasciata, M. marginata and M. seminigra merrillae were collected from hives in South Brazil. VO were obtained by hydrodistillation and characterised by gas chromatography coupled to mass spectrometry (GC/MS). Antimicrobial activity was assessed by microplate dilution method. The lowest MIC against cell walled bacteria was 219±0 μg mL−1 from M. quadrifasciata geopropolis VO with Staphylococcus aureus. The M. b. schencki geopropolis VO minimal inhibition concentration (MIC) was 424±0 μg mL−1 against all the mycoplasma strains evaluated. Fractionation resulted in the reduction of 50 % of the MIC value from the original oil. However, its compounds’ synergism seems to be essential to this activity. Antibiofilm assays demonstrated 15.25 % eradication activity and 13.20 % inhibition of biofilm formation after 24 h for one subfraction at 2× its MIC as the best results found. This may be one of the essential mechanisms by which geopropolis VOs perform their antimicrobial activity.  相似文献   
9.
We have analyzed genomic DNA in a large number of independent examples of five HLA-DQw2-bearing extended haplotypes for their associated subtypes by restriction fragment length polymorphism (RFLP) using DRB, DQA, and DQB probes after Taq I and Pst I digestion and Southern blotting. In addition to three previously described HLA-DQw2 subtypes, DQw2a, DQw2b, and DQw2c, we observed a fourth subtype, HLA-DQw2d, characterized by 5.8 kilobase (kb) DRB/Taq I, 2.4, 2.3, and 1.8 kb DQB/Taq I, and 8.0 and 2.3 kb DQA/Pst I fragments. All 22 independent examples of the extended haplotype [HLA-B8,SCO1,DR3] carried DQw2a and all 11 independent examples of [HLA-B18,F1C30,DR3] carried DQw2b. In addition, all independent examples (21 and 4, respectively) of two DR7-carrying extended haplotypes, [HLA-B44,FC31,DR7] and [HLA-Bw47,FC91,0,DR7], carried DQw2c and all independent examples of [HLA-Bw57,SC61,DR7] carried DQw2d. Our results show that the DNA in the DR/DQ region of extended haplotypes is relatively fixed and that different DQw2 subtypes characterize different DQw2-bearing extended haplotypes.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号