Biomechanics and Modeling in Mechanobiology - Planar biaxial testing is commonly used to characterize the mechanical properties of arteries, but stresses associated with specimen flattening during...  相似文献   
2.
Accurate characterization of carotid artery geometry is vital to our understanding of the pathogenesis of atherosclerosis. Three-dimensional computer reconstructions based on medical imaging are now ubiquitous; however, mean carotid artery geometry has not yet been comprehensively characterized. The goal of this work was to build and study such geometry based on data from 16 male patients with severe carotid artery disease. Results of computerized tomography angiography were used to analyze the cross-sectional images implementing a semiautomated segmentation algorithm. Extracted data were used to reconstruct the mean three-dimensional geometry and to determine average values and variability of bifurcation and planarity angles, diameters and cross-sectional areas. Contrary to simplified carotid geometry typically depicted and used, our mean artery was tortuous exhibiting nonplanarity and complex curvature and torsion variations. The bifurcation angle was 36 deg?±?11 deg if measured using arterial centerlines and 15 deg?±?14 deg if measured between the walls of the carotid bifurcation branches. The average planarity angle was 11 deg?±?10 deg. Both bifurcation and planarity angles were substantially smaller than values reported in most studies. Cross sections were elliptical, with an average ratio of semimajor to semiminor axes of 1.2. The cross-sectional area increased twofold in the bulb compared to the proximal common, but then decreased 1.5-fold for the combined area of distal internal and external carotid artery. Inter-patient variability was substantial, especially in the bulb region; however, some common geometrical features were observed in most patients. Obtained quantitative data on the mean carotid artery geometry and its variability among patients with severe carotid artery disease can be used by biomedical engineers and biomechanics vascular modelers in their studies of carotid pathophysiology, and by endovascular device and materials manufacturers interested in the mean geometrical features of the artery to target the broad patient population.  相似文献   
3.
Low-temperature EPR spectra of chromaffin granule membranes from bovine adrenal medulla reveal 3 different signals of the ferric cytochrome b-561. A typical gZ signal of a low-spin cytochrome observed at g approximately 3 is comprised of a high-potential component with gZ = 3.14 and a low-potential one with gZ = 3.11, the low-potential signal showing significantly faster relaxation. In addition, a highly temperature-sensitive heme signal at g = 3.7 is observed which is fully retained in the preparation of granule membranes with b-561 reduced by 50% but disappears upon full reduction of the cytochrome by ascorbate. The signal is strikingly similar to that of the mitochondrial low-potential cytochrome b heme (bL or b-566). The presence of several forms of b-561 in chromaffin granule membranes may provide a structural basis for the transmembrane electron transfer believe to be catalyzed by this hemoprotein.  相似文献   
4.
Femoropopliteal artery (FPA) reconstructions are notorious for poor clinical outcomes. Mechanical and flow conditions that occur in the FPA with limb flexion are thought to play a significant role, but are poorly characterized. FPA deformations due to acute limb flexion were quantified using a human cadaver model and used to build a finite element model that simulated surrounding tissue forces associated with limb flexion-induced deformations. Strains and intramural principal mechanical stresses were determined for seven age groups. Computational fluid dynamics analysis was performed to assess hemodynamic variables. FPA shape, stresses, and hemodynamics significantly changed with age. Younger arteries assumed straighter positions in the flexed limb with less pronounced bends and more uniform stress distribution along the length of the artery. Even in the flexed limb posture, FPAs younger than 50 years of age experienced tension, while older FPAs experienced compression. Aging resulted in localization of principal mechanical stresses to the adductor hiatus and popliteal artery below the knee that are typically prone to developing vascular pathology. Maximum principal stresses in these areas increased threefold to fivefold with age with largest increase observed at the adductor hiatus. Atheroprotective wall shear stress reduced after 35 years of age, and atheroprone and oscillatory shear stresses increased after the age of 50. These data can help better understand FPA pathophysiology and can inform the design of targeted materials and devices for peripheral arterial disease treatments.  相似文献   
5.
High failure rates of femoropopliteal artery reconstruction are commonly attributed to complex 3D arterial deformations that occur with limb movement. The purpose of this study was to develop a method for accurate assessment of these deformations. Custom-made stainless-steel markers were deployed into 5 in situ cadaveric femoropopliteal arteries using fluoroscopy. Thin-section CT images were acquired with each limb in the straight and acutely bent states. Image segmentation and 3D reconstruction allowed comparison of the relative locations of each intra-arterial marker position for determination of the artery’s bending, torsion and axial compression. After imaging, each artery was excised for histological analysis using Verhoeff–Van Gieson staining. Femoropopliteal arteries deformed non-uniformly with highly localized deformations in the proximal superficial femoral artery, and between the adductor hiatus and distal popliteal artery. The largest bending (11±3–6±1 mm radius of curvature), twisting (28±9–77±27°/cm) and axial compression (19±10–30±8%) were registered at the adductor hiatus and the below knee popliteal artery. These deformations were 3.7, 19 and 2.5 fold more severe than values currently reported in the literature. Histology demonstrated a distinct sub-adventitial layer of longitudinally oriented elastin fibers with intimal thickening in the segments with the largest deformations. This endovascular intra-arterial marker technique can quantify the non-uniform 3D deformations of the femoropopliteal artery during knee flexion without disturbing surrounding structures. We demonstrate that 3D arterial bending, torsion and compression in the flexed lower limb are highly localized and are substantially more severe than previously reported.  相似文献   
6.
Open and endovascular treatments for peripheral arterial disease are notorious for high failure rates. Severe mechanical deformations experienced by the femoropopliteal artery (FPA) during limb flexion and interactions between the artery and repair materials play important roles and may contribute to poor clinical outcomes. Computational modeling can help optimize FPA repair, but these simulations heavily depend on the choice of constitutive model describing the arterial behavior. In this study finite element model of the FPA in the standing (straight) and gardening (acutely bent) postures was built using computed tomography data, longitudinal pre-stretch and biaxially determined mechanical properties. Springs and dashpots were used to represent surrounding tissue forces associated with limb flexion-induced deformations. These forces were then used with age-specific longitudinal pre-stretch and mechanical properties to obtain deformed FPA configurations for seven age groups. Four commonly used invariant-based constitutive models were compared to determine the accuracy of capturing deformations and stresses in each age group. The four-fiber FPA model most accurately portrayed arterial behavior in all ages, but in subjects younger than 40 years, the performance of all constitutive formulations was similar. In older subjects, Demiray (Delfino) and classic two-fiber Holzapfel–Gasser–Ogden formulations were better than the Neo-Hookean model for predicting deformations due to limb flexion, but both significantly overestimated principal stresses compared to the FPA or Neo-Hookean models.  相似文献   
7.
Biomechanics and Modeling in Mechanobiology - Femoropopliteal artery (FPA) mechanics play a paramount role in pathophysiology and the artery’s response to therapeutic interventions, but data...  相似文献   
8.
The biomechanics of large- and medium-sized arteries influence the pathophysiology of arterial disease and the response to therapeutic interventions. However, a comprehensive comparative analysis of human arterial biaxial mechanical properties has not yet been reported. Planar biaxial extension was used to establish the passive mechanical properties of human thoracic (TA, \(n=8\) ) and abdominal (AA, \(n=7\) ) aorta, common carotid (CCA, \(n=21\) ), subclavian (SA, \(n=12\) ), renal (RA, \(n=13\) ) and common iliac (CIA, \(n=16\) ) arteries from 11 deceased subjects ( \(54\pm 21\)  years old). Histological evaluation determined the structure of each specimen. Experimental data were used to determine constitutive parameters for a structurally motivated nonlinear anisotropic constitutive model. All arteries demonstrated appreciable anisotropy and large nonlinear deformations. Most CCA, SA, TA, AA and CIA specimens were stiffer longitudinally, while most RAs were stiffer circumferentially. A switch in anisotropy was occasionally demonstrated for all arteries. The CCA was the most compliant, least anisotropic and least frequently diseased of all arteries, while the CIA and AA were the stiffest and the most diseased. The severity of atherosclerosis correlated with age, but was not affected by laterality. Elastin fibers in the aorta, SA and CCA were uniformly and mostly circumferentially distributed throughout the media, while in the RA and CIA, elastin was primarily axially aligned and concentrated in the external elastic lamina. Constitutive modeling provided good fits to the experimental data for most arteries. Biomechanical and architectural features of major arteries differ depending on location and functional environment. A better understanding of localized arterial mechanical properties may support the development of site-specific treatment modalities for arterial disease.  相似文献   
9.
Patch angioplasty is the most common technique used for the performance of carotid endarterectomy. A large number of patching materials are available for use while new materials are being continuously developed. Surprisingly little is known about the mechanical properties of these materials and how these properties compare with those of the carotid artery wall. Mismatch of the mechanical properties can produce mechanical and hemodynamic effects that may compromise the long-term patency of the endarterectomized arterial segment. The aim of this paper was to systematically evaluate and compare the biaxial mechanical behavior of the most commonly used patching materials. We compared PTFE (n = 1), Dacron (n = 2), bovine pericardium (n = 10), autogenous greater saphenous vein (n = 10), and autogenous external jugular vein (n = 9) with the wall of the common carotid artery (n = 18). All patching materials were found to be significantly stiffer than the carotid wall in both the longitudinal and circumferential directions. Synthetic patches demonstrated the most mismatch in stiffness values and vein patches the least mismatch in stiffness values compared to those of the native carotid artery. All biological materials, including the carotid artery, demonstrated substantial nonlinearity, anisotropy, and variability; however, the behavior of biological and biologically-derived patches was both qualitatively and quantitatively different from the behavior of the carotid wall. The majority of carotid arteries tested were stiffer in the circumferential direction, while the opposite anisotropy was observed for all types of vein patches and bovine pericardium. The rates of increase in the nonlinear stiffness over the physiological stress range were also different for the carotid and patching materials. Several carotid wall samples exhibited reverse anisotropy compared to the average behavior of the carotid tissue. A similar characteristic was observed for two of 19 vein patches. The obtained results quantify, for the first time, significant mechanical dissimilarity of the currently available patching materials and the carotid artery. The results can be used as guidance for designing more efficient patches with mechanical properties resembling those of the carotid wall. The presented systematic comparative mechanical analysis of the existing patching materials provides valuable information for patch selection in the daily practice of carotid surgery and can be used in future clinical studies comparing the efficacy of different patches in the performance of carotid endarterectomy.  相似文献   