首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   24篇
  免费   4篇
  2020年   1篇
  2018年   1篇
  2014年   2篇
  2013年   2篇
  2011年   1篇
  2010年   2篇
  2009年   1篇
  2007年   3篇
  2006年   1篇
  2001年   3篇
  2000年   2篇
  1999年   1篇
  1994年   1篇
  1992年   1篇
  1991年   1篇
  1988年   1篇
  1982年   1篇
  1977年   2篇
  1955年   1篇
排序方式: 共有28条查询结果,搜索用时 15 毫秒
1.
2.
Factors influencing the output of an implantable force transducer   总被引:1,自引:0,他引:1  
The objective of this study was to evaluate the performance of the Arthroscopically Implantable Force Probe (AIFP; MicroStrain, Burlington VT) for measuring force in a patellar tendon graft. Transducer drift, reproducibility of output due to the number of loading cycles and device location, and sensitivity to the tendon cross-sectional area were investigated. The AIFP was initialized, and then implanted into five human patellar tendon grafts three times; twice within the same location and once in a different location. The tendons were cyclically loaded in uniaxial tension for 500 cycles in each insertion site. The AIFP was then removed from the tendon and the baseline output was remeasured. It was determined that transducer drift was negligible. The relationship between the tensile load applied to the graft and AIFP output was quadratic and specimen dependent. The cyclic load response of the tendon-AIFP interface demonstrated a 24.9% decrease over the first 20 loading cycles, and subsequent cycling yielded relatively reproducible output. The output of the transducer varied when it was removed from the tendon and then reimplanted in the same location (range 3.7-109. 4% error), as well as in the second location (range 1.5-202.8% error). No correlation was observed between the cross-sectional area of the tendon and transducer output. This study concludes that implantable force probes should be used with caution and calibrated without removing the transducer from the graft.  相似文献   
3.
Animal models are widely used to study cartilage degeneration. Experimental interventions to alter contact mechanics in articular joints may also affect the loads borne by the leg during gait and consequently affect the overall loading experienced in the joint. In this study, force plate analyses were utilized to measure parameters of gait in the rear legs of adult rats following application of a varus loading device that altered loading in the knee. Adult rats were assigned to Control, Sham, or Loaded groups (n≥4/each). Varus loading devices were surgically attached to rats in the Sham and Loaded groups. In the Loaded group, this device applied a controlled compressive overload to the medial compartment of the knee during periods of engagement. Peak ground reaction forces during walking were recorded for each rear leg of each group. Analyses of variance were used to compare outcomes across groups (Control, Sham, and Loaded), leg (contralateral, experimental) and device status (disengaged, engaged) to determine the effects of surgically attaching the device and applying a compressive overload to the joint with the device. The mean peak vertical force in the experimental leg was reduced to 30% in the Sham group in comparison to the contralateral leg and the Control group, indicating an effect of attaching the device to the leg (p<0.01). No differences were found in ground reaction forces between the Sham and Loaded groups with application of compressive overloads with the device. The significant reduction in vertical force due to the surgical attachment of the varus loading device must be considered and accounted for in future studies.  相似文献   
4.
5.
The purpose of this investigation was to study the effect of one-legged exercise on the strength, power and endurance of the contralateral leg. The performance of the knee extensor and flexor muscle of 20 healthy young adults (10 men and 10 women) was first tested by Cybex II+ and 340 dynamometers. Then 10 subjects were chosen at random to train using one leg three times a week for 7 weeks whilst the other 10 served as controls. During the 8th week, the tests were repeated. Both quadriceps and hamstring muscles of the trained subjects showed a cross-transfer effect from the trained limb to the untrained side. This concerned the strength and power, as well as endurance characteristics of these muscles. The average change in peak torque of the quadriceps muscle was +19% (P less than 0.001) in the trained limb, +11% (P less than 0.01) in the untrained limb and 0% in the control limbs. In hamstring muscles the changes were +14% (P less than 0.01), +5% and -1%, respectively. Concerning muscle endurance (work performed during the last 5 contractions in the 25-repetition test) the corresponding changes were +15% (P less than 0.01), +7% (P less than 0.01), and -1% in quadriceps muscle, and +17% (P less than 0.05), +7%, and -3% in hamstring muscles. The average strength benefit in the untrained limb was +36% (hamstring muscles) and +58% (quadriceps muscle) of that achieved in the trained limb. Untrained hamstring muscle showed better benefits in the endurance parameters than in strength or power parameters, while in the quadriceps muscle this effect was reversed. A positive relationship was observed between the changes (greater improvement in the trained limb resulted in greater improvement in the untrained limb) (hamstring muscles: r = 0.83, P less than 0.001, quadriceps muscle: r = 0.53, P less than 0.001). In endurance parameters, this relationship was almost linear while in the strength and power parameters the results were more in favour of a curvilinear relationship with limited benefit.  相似文献   
6.
番茄和鸡蛋果叶片中可提取的SOD活性不受低温的影响。在电泳谱带上SOD主同工酶带被氰化物而不被低温抑制,次同工酶带在低温下不稳定,且活性很低,它的变化不影响总的SOD活性。一些冷敏感植物叶片中CAT活性被低温抑制,而H_2O_3水平在低温下稳定或有增加,这可能使毒性更强的羟基离子(OH·)易于形成。  相似文献   
7.
8.
The objective of this study was to evaluate two calibration methods for the "Arthroscopically Implantable Force Probe" (AIFP) that are potentially suitable for in vivo use: (1) a direct, experimentally based method performed by applying a tensile load directly to the graft after it is harvested but prior to implantation (the "pre-implantation" technique), and (2) an indirect method that utilizes cadaver-based analytical expressions to transform the AIFP output versus anterior shear load relationship, which may be established in vivo, to resultant graft load (the "post-implantation" technique). The AIFP outputs during anterior shear loading of the knee joint using these two calibration methods were compared directly to graft force measurements using a ligament cutting protocol and a 6 DOF load cell. The mean percent error (actual-measured)/(actual)* 100) associated with the pre-implantation calibration ranged between 85 and 175 percent, and was dependent on the knee flexion angle tested. The percent error associated with the post-implantation technique was evaluated in two load ranges: loads less than 40 N, and loads greater than 40 N. For graft force values greater than 40 N, the mean percent errors inherent to the post-implantation calibration method ranged between 20 and 29 percent, depending on the knee flexion angle tested. Below 40 N, these errors were substantially greater. Of the two calibration methods evaluated, the post-implantation approach provided a better estimate of the ACL graft force than the pre-implantation technique. However, the errors for the post-implantation approach were still high and suggested that caution should be employed when using implantable force probes for in vivo measurement of ACL graft forces.  相似文献   
9.
The genus Ceratocystis sensu stricto includes important fungal pathogens of woody and herbaceous plants. This genus is distinguished from species in Ceratocystis sensu lato by the presence of Chalara anamorphs. Ascospore shape has been used extensively in delineating Ceratocystis taxa, which show a large variety of ascospore shapes. Sequence analysis of one region of he 18S ribosomal RNA subunit and two regions of the 28S ribosomal RNA subunit showed that there was a majority of multiple substitutions at nucleotide sites and that there was a low transition/transversion ratio, T = 0.72. Both of these results suggest that these are well established, old species. Ascospore morphology, for the most part, was not congruent with the molecular phylogeny, and the use of morphological characters may be misleading in the taxonomy of these species.   相似文献   
10.
A force balance between the ligaments, articular contact, muscles and body weight maintains knee joint stability. Thus, it is important to study anterior cruciate ligament (ACL) biomechanics, in vivo, under weightbearing conditions. Our objective was to compare the ACL strain response under weightbearing and non-weightbearing conditions and in combination with three externally applied loadings: (1) anterior-posterior shear forces, (2) internal-external torques, and (3) varus-valgus moments. A strain transducer was implanted on the ACL of 11 subjects. All joint loadings were performed with the knee at 20 degrees of flexion. A significant increase in ACL strain was observed as the knee made the transition from non-weightbearing to weightbearing. During anterior shear loading, the strain values produced during weightbearing were greater than those of the non-weightbearing knee (shear loads <40N). At higher shear loads, the strain values became equal. During axial torsion, an internal torque of 10Nm strained the ACL when the knee was non-weightbearing while an equivalent external torque did not. Weightbearing significantly increased ACL strain values in comparison to non-weightbearing with the application of external torques and low internal torques (<3Nm). The strains became equal for higher internal torques. For V-V loading, the ACL was not strained in the non-weightbearing knee. However, weightbearing increased the ACL strain values over the range of moments tested. These data have important clinical ramifications in the development of rehabilitation protocols following ACL reconstruction since weightbearing has been previously thought to provide a protective mechanism to the healing graft.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号