首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   197篇
  免费   14篇
  国内免费   1篇
  2024年   1篇
  2023年   10篇
  2022年   13篇
  2021年   20篇
  2020年   17篇
  2019年   7篇
  2018年   9篇
  2017年   1篇
  2016年   3篇
  2015年   18篇
  2014年   20篇
  2013年   14篇
  2012年   13篇
  2011年   10篇
  2010年   18篇
  2009年   7篇
  2008年   7篇
  2007年   6篇
  2005年   2篇
  2004年   2篇
  2003年   1篇
  2001年   2篇
  2000年   1篇
  1999年   2篇
  1998年   1篇
  1995年   2篇
  1994年   1篇
  1991年   1篇
  1989年   1篇
  1984年   1篇
  1983年   1篇
排序方式: 共有212条查询结果,搜索用时 15 毫秒
1.
Curative radiofrequency catheter modification of the slow pathway is the recommended therapy for patients suffering from recurrent symptomatic atrioventricular nodal reentry tachycardia. This is usually performed via femoral vein and the inferior vena cava (IVC). Presence of venous occlusion or complex venous anomaly involving the IVC may preclude this approach. Here, we report a case with a complex venous anomaly involving the inferior vena cava, who underwent electrophysiological study and successful radiofrequency ablation by an alternative approach.  相似文献   
2.
The energy status of mammalian cells is a finely regulated phenomenon. This is especially true in cardiac muscle cells in which energy requirements are high and the system must provide rapid turnover of the adenine nucleotides and instant response to changes in energetic demands. We have examined the acute response of the rat myocardium to ventricular pacing up to 2.5 times the resting heart rate. The purpose of this study was to determine at what level of pacing the normal energy status could be maintained and at what point it was compromised. Myocardial energy charge (EC = (ATP + 0.5 ADP)/(ATP + ADP + AMP)) was maintained at 1, 1.5 and 2 times the resting heart rate but declined significantly at 2.5 times. In contrast, phosphorylation potential (PP = ATP/ADP1 × Pi) was drastically altered in hearts paced at 1.5, 2 and 2.5 times the resting rate. Tissue lactate increased and glycogen decreased in a linear fashion as pacing rate increased, indicating that the metabolic challenge was proportional to the pacing rate. EC seems to reflect the overall status of the cell and its ability to maintain a dynamic equilibrium. PP may reflect the immediate and necessary driving force for mitochondrial respiration in times of increased demand. These data suggest that the myocardium may meet the increased energy demands of acute ventricular pacing by shifting the molar ratio of ATP to ADP times Pi in favour of driving phosphorylation.  相似文献   
3.
摘要 目的:探讨血清脑钠肽(BNP)、超敏C反应蛋白(hs-CRP)、可溶性致瘤抑制素2(sST2)对阵发性心房颤动(AF)患者射频消融(RFA)术后复发的预测价值。方法:选择2016年1月至2020年12月我院收治的接受RFA术治疗的82例阵发性AF患者,术后随访12个月,根据术后是否复发分为复发组(25例)和未复发组(57例)。检测患者血清BNP、hs-CRP、sST2水平,收集临床相关资料,采用多因素Logistic回归模型分析影响阵发性AF患者RFA术后复发的因素,采用受试者工作特征(ROC)曲线分析血清BNP、hs-CRP、sST2预测阵发性AF患者RFA术后复发的价值。结果:复发组血清BNP、hs-CRP、sST2水平高于未复发组(P<0.05)。血清BNP、hs-CRP、sST2水平升高、AF病程增长是影响阵发性AF患者RFA术后复发的危险因素(P<0.05)。血清BNP、hs-CRP、sST2预测阵发性AF患者消融术后复发的曲线下面积分别为0.720、0.694、0.718,联合三者预测阵发性AF患者RFA术后复发的曲线下面积为0.866,高于BNP、hs-CRP、sST2单独预测。结论:阵发性AF患者血清BNP、hs-CRP、sST2水平升高是RFA术后复发的危险因素,联合检测血清BNP、hs-CRP、sST2水平有助于预测阵发性AF患者RFA术后复发。  相似文献   
4.
Implantable cardioverter-defibrillators (ICDs) terminate ventricular tachycardia (VT) and ventricular fibrillation (VF) with high efficacy and can protect patients from sudden cardiac death (SCD). However, inappropriate shocks may occur if tachycardias are misdiagnosed. Inappropriate shocks are harmful and impair patient quality of life. The risk of inappropriate therapy increases with lower detection rates programmed in the ICD. Single-chamber detection poses greater risks for misdiagnosis when compared with dual-chamber devices that have the benefit of additional atrial information. However, using a dual-chamber device merely for the sake of detection is generally not accepted, since the risks associated with the second electrode may outweigh the benefits of detection. Therefore, BIOTRONIK developed a ventricular lead called the LinoxSMART S DX, which allows for the detection of atrial signals from two electrodes positioned at the atrial part of the ventricular electrode. This device contains two ring electrodes; one that contacts the atrial wall at the junction of the superior vena cava (SVC) and one positioned at the free floating part of the electrode in the atrium. The excellent signal quality can only be achieved by a special filter setting in the ICD (Lumax 540 and 740 VR-T DX, BIOTRONIK). Here, the ease of implantation of the system will be demonstrated.  相似文献   
5.
BackgroundPatients with outflow tract ventricular tachycardia (OTVT) with normal echocardiogram are labeled as idiopathic VT (IVT). However, a subset of these patients is subsequently diagnosed with underlying cardiac sarcoidosis (CS). Objective:Whether electrocardiogram (ECG) abnormalities in sinus rhythm (SR) can differentiate underlying CS from IVT.MethodsWe retrospectively analyzed the SR-ECGs of 42 patients with OTVT/premature ventricular complexes (PVC) and normal echocardiography. All underwent advanced imaging with cardiac magnetic resonance (CMR)/18FDG PET-CT for screening of CS. Twenty-two patients had significant abnormalities in cardiac imaging and subsequently had biopsy-proven CS (Cases). Twenty patients had normal imaging and were categorized as IVT (Controls). SR-ECGs of all patients were analyzed by 2 independent, blinded observers.ResultsBaseline characteristics were comparable. Among the ECG features analyzed – fascicular (FB) or bundle branch block (BBB) was seen in 9/22 Cases vs. 1/20 controls (p = 0.01). Among patients without FB or BBB, fragmented QRS (fQRS) was present in 9/13 cases but in none of the controls (p < 0.001). Low voltage QRS was more often seen among cases as compared to controls (10/22 vs. 3/20 p = 0.03). A stepwise algorithm based on these 3 sets of ECG findings helped to diagnose CS among patients presenting with OTVT/PVC with sensitivity of 91%, specificity of 75%, a PPV of 80%, and a NPV of 88%.ConclusionsIn patients presenting with OTVT/PVC: FB/BBB, fQRS, and low QRS voltage on the baseline ECG were more often observed among patients with underlying CS as compared to true IVT. These findings may help to distinguish underlying CS among Cases presenting with OTVT/PVC.  相似文献   
6.
BackgroundVoltage mapping is critical to define substrate during ablation. In ventricular tachycardia, abnormal potentials may be targets. However, wavefront of activation could impact local signal characteristics. This may be particularly true when comparing sinus rhythm versus paced rhythms. We sought to determine how activation wavefront impacts electrogram characteristics.MethodsPatients with ischemic cardiomyopathy, ventricular tachycardia, and without fascicular or bundle branch block were included. Point by point mapping was done and at each point, one was obtained during an atrial paced rhythm and one during a right ventricular paced rhythm. Signals were adjudicated after ablation to define late potentials, fractionated potentials, and quantify local voltage. Areas of abnormal voltage (defined as <1.5 mV) were also determined.Results9 patients were included (age 61.3 ± 9.2 years, 56% male, mean LVEF 34.9 ± 8.6%). LV endocardium was mapped with an average 375 ± 53 points/rhythm. Late potentials were more frequent during right ventricular pacing (51 ± 21 versus 32 ± 15, p < 0.01) while overall scar area was higher during atrial pacing (22 ± 11% vs 13 ± 7%, p < 0.05). In 1/9 patients, abnormal potentials were seen during a right ventricular paced rhythm that were not apparent in an atrial paced rhythm, ablation of which resulted in non-inducibility.ConclusionRhythm in which mapping is performed has an impact on electrogram characteristics. Whether one rhythm is preferable to map in remains to be determined. However, it is possible defining local signals during normal conduction as well as variable paced rhythms may impart a greater likelihood of elucidating arrhythmogenic substrate.  相似文献   
7.
Intrinsic anti-tachycardia pacing (iATP) is a novel automated ATP algorithm that employs post-pacing interval (PPI) to design the next ATP sequence based on an analysis of the prior failed ATP sequence. A patient with hypertrophic cardiomyopathy received an implantable cardioverter-defibrillator (ICD) (Cobalt™ XT DR, Medtronic, Minneapolis, MN, USA) following an episode of syncope due to macro-reentrant ventricular tachycardia (VT) (right bundle branch block configuration, cycle length [CL] 280 ms). The VF zone was set to VTCL <300 ms and iATP therapy was prescribed before and during capacitor charging. The iATP was initiated when VT recurred 3 months later. The first attempt with an assumption of 150 ms propagation time from the pacing site to the VT circuit (9 pulses) could not reset the VT, leaving a PPI of 650 ms. A subsequent attempt involving 20 pulses with an assumption of 250 ms propagation time terminated the VT. Failure to reach the circuit is a major cause of unsuccessful ATP. In this regard, iATP is expected to have theoretical advantages over empirical and traditional ATP therapies. To the best of our knowledge, this is the first intracardiac electrogram illustrating how automated precision ATP terminates VT in a clinical setting.  相似文献   
8.
BackgroundThe single procedure success rates of durable pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) varies between 80 and 90%. Ablation index, incorporating contact force, stability, time and power is a more profound parameter of significant lesion size and has been established. Equally important is a stringent contiguity of the lesion set.Methods and resultsA total number of 100 consecutive patients undergoing de-novo catheter ablation for paroxysmal atrial fibrillation (PAF) were analyzed between 2016 and 2019. In the first 50 patients (group A) PVI was performed using a surround flow, contact force catheter (Biosense Webster Thermocool STSF, Biosense Webster, USA) with a drag-and-ablate technique to encircle the PVs. In the following 50 patients (group B), PVI was performed using ablation index and a stringent lesion contiguity with an interlesion distance (ILD) of <5 mm. The baseline characteristics showed no significant differences between both groups. During a mean follow-up of 18 ± 3 months after a single procedure, 36 (72%) patients of group A were free of arrhythmia recurrence versus 43 (86%) patients in group B (p = 0.047). A total of 14 patients (group A: 10 (20%), group B: 4 (8%); underwent a redo-procedure. 7 patients of group A (14%) and 2 patients of group B (4%) showed recovered veins. In 3 patients of group A and 2 patients of group B the PVs were durably isolated. In these patients persistent AF recurrence was caused by extra-PV AF sources. Four patients of group A and three patients of group B had continued paroxysmal or persistent AF but did not undergo redo-procedure. With regard to the procedural data, the procedure time, the total energy and the fluoroscopy time were significantly lower in group B (AI and ILD <5 mm) (128.86 ± 18.19 versus 115.35 ± 15.38; p < 0.05; 1619.16 ± 988.56 versus 1186.26 ± 756.34; p < 0.05; 11.49 ± 3.20 versus 9.66 ± 3.86; p = 0.04). Both procedures were performed with a low number of complications, no pericardial effusion was seen in either group.ConclusionsPVI using ablation index in combination with a stringent lesion contiguity improves clinical outcome after first-time PVI with lower PVI recovery, shorter procedure times, lower total energy and shorter fluoroscopy times and therefore, is more efficient.  相似文献   
9.
Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an inherited cardiac arrhythmia syndrome that often leads to sudden cardiac death. The most common form of CPVT is caused by autosomal-dominant variants in the cardiac ryanodine receptor type-2 (RYR2) gene. Mutations in RYR2 promote calcium (Ca2+) leak from the sarcoplasmic reticulum (SR), triggering lethal arrhythmias. Recently, it was demonstrated that tetracaine derivative EL20 specifically inhibits mutant RyR2, normalizes Ca2+ handling and suppresses arrhythmias in a CPVT mouse model. The objective of this study was to determine whether EL20 normalizes SR Ca2+ handling and arrhythmic events in induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) from a CPVT patient. Blood samples from a child carrying RyR2 variant RyR2 variant Arg-176-Glu (R176Q) and a mutation-negative relative were reprogrammed into iPSCs using a Sendai virus system. iPSC-CMs were derived using the StemdiffTM kit. Confocal Ca2+ imaging was used to quantify RyR2 activity in the absence and presence of EL20. iPSC-CMs harbouring the R176Q variant demonstrated spontaneous SR Ca2+ release events, whereas administration of EL20 diminished these abnormal events at low nanomolar concentrations (IC50 = 82 nM). Importantly, treatment with EL20 did not have any adverse effects on systolic Ca2+ handling in control iPSC-CMs. Our results show for the first time that tetracaine derivative EL20 normalized SR Ca2+ handling and suppresses arrhythmogenic activity in iPSC-CMs derived from a CPVT patient. Hence, this study confirms that this RyR2-inhibitor represents a promising therapeutic candidate for treatment of CPVT.  相似文献   
10.
目的:评价胺碘酮联合厄贝沙坦治疗慢性心功能不全合并阵发性房颤的临床疗效及安全性.方法:选择我院收治的慢性心衰合并阵发性房颤患者167例,均使用胺碘酮维持窦性心律,根据患者是否加用厄贝沙坦分为治疗组及对照组.治疗一年后,观察和比较两组患者的心衰住院率、左室射血分数、左房内径、心功能分级情况,通过动态心电图评估窦性心律维持率、房颤复发率.结果:治疗后,治疗组房颤的复发率、慢性房颤的发生率均明显低于对照组,窦性心律维持率明显高于对照组,左房内径较对照组明显减小,心衰住院率明显低于对照组,差异均有统计学意义(P<0.05);对照组左房内径较治疗前明显扩大(P<0.05),两组患者在心功能分级方面较治疗前均有明显改善(P<0.05),但两组之间心功能分级比较无统计学差异(P>0.05).两组不良反应(甲状腺功能异常、肝功能异常、肺纤维化、低血压)的发生率比较无统计学差异(P>0.05).结论:胺碘酮联合厄贝沙坦治疗慢性心功能不全伴阵发性房颤的患者,能较好的维持窦性心律,降低心衰住院率,对心脏重构有较好的改善作用,且具有良好的安全性.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号