首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   45篇
  免费   7篇
  2023年   2篇
  2021年   2篇
  2019年   2篇
  2018年   3篇
  2017年   8篇
  2016年   2篇
  2015年   4篇
  2014年   12篇
  2013年   3篇
  2012年   1篇
  2011年   1篇
  2010年   2篇
  2009年   1篇
  2008年   4篇
  2007年   2篇
  2006年   1篇
  2004年   1篇
  1995年   1篇
排序方式: 共有52条查询结果,搜索用时 46 毫秒
51.
PurposeThe therapeutic success of minimal invasive glaucoma surgery (MIGS) is challenging due to many factors including fibrotic or occlusive events. Recent clinical data show sudden peaks of intraocular pressure (IOP) in the postoperative care of glaucoma patients after suprachoroidal draining stents. Yet, the reasons for the IOP peaks are speculative. As a link between trace elements and fibrosis had been previously observed in systemic disorders, the present study aimed to investigate the impact of trace elements on the therapeutic success of the suprachoroidal draining stents in patients with open-angle glaucoma (OAG).Material and MethodsAn analysis of a prospective single-center study was done: fifty-five eyes of patients with OAG (29 female, 26 male) underwent Cypass Micro-Stent implantation either as a stand-alone procedure or combined with cataract surgery. All patients underwent pre-operatively an ophthalmological examination which included slit lamp biomicroscopy and fundoscopy. IOP was measured by Goldmann applanation tonometry. Functional and morphometric data were assessed by Octopus G1-perimetry, which included measurement of retinal nerve fiber layer thickness (Spectralis OCT). Data of the patients’ follow-ups were recorded during 18 months post-operatively. The therapeutic success of CyPass Micro-Stent was classified as ‘success’ (IOP reduction ≥20% compared to a pre-operative baseline without any medication), ‘qualified success’ (IOP reduction ≥20 % with same or lower additional eye medication), and ‘failure’ (IOP reduction ≤20 % or additional surgical treatment necessary). Aqueous humour was extracted once during surgery for analysis of the level of 14 trace elements: Copper (Cu), Cadmium (Cd), Cobalt (Co), Chromium (Cr), Iron (Fe), Lithium (Li), Magnesium (Mg), Manganese (Mn), Phosphorus (P), Lead (Pb), Titanium (Ti), Uranium (U), Vanadium (V), and Zinc (Zn). Analysis of the trace elements was done using an ELEMENT 2, ICP-sf-MS instrument (Thermo-Fisher Scientific, Bremen, Germany). Analysis of levels of trace elements was done across the patients’ groups of the three subclasses of therapeutic success. Statistical investigations for substantial differences were conducted using the method of least squares to fit general linear models and mixed models. The last one for the repeated measurements of IOP.ResultsLevels of Mg were significantly lower one month postoperatively in the success group (LS-Mean 1.30 mg/L) compared to the qualified success group (LS-Mean 1.22 mg/L; p-value = 0.04). Fe was significantly increased in the failure group (LS-Mean 2.07 µg/L) compared to the qualified success group (LS-Mean 1.64 µg/L; p-value = 0.019) after 3 months of follow-up. Additionally, Fe levels were significantly lower in the success group (LS-Mean 1.47 µg/L) compared to the failure cohort (LS-Mean 2.07 µg/L; p-value = 0.009). After a period of 18 months, significantly higher levels of Mn were observed in the success group (LS-Mean 1.24 µg/L) than in the failure group (LS Mean 0.30 µg/L, p-value = 0.019).ConclusionThe present data might suggest that trace elements can influence therapeutic success of suprachoroidal draining devices postoperatively and thus offer first hints for potential novel therapeutic options.  相似文献   
52.
Radiotherapy is being performed in many situations as a curative approach for head and neck cancer instead of surgery due to the current novel coronavirus disease (COVID-19) pandemic. A recent publication reported that even hypofractionation was being conducted in order to reduce the daily exposure of both patients and the medical staff involved in cancer therapies. As a result, dental teams may be requested more frequently than usual to fabricate intraoral stents (IOS). Given that IOS may be a potential source of COVID-19 contagion, the main purpose of the present correspondence is to offer a guide on how health professionals may be safely presented in the room, on the management of the IOS and also how to sanitize the stents.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号