首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
Cellular senescence plays an important role in organismal aging and age‐related diseases. However, it is challenging to isolate low numbers of senescent cells from small volumes of biofluids for downstream analysis. Furthermore, there is no technology that could selectively remove senescent cells in a high‐throughput manner. In this work, we developed a novel microfluidic chip platform, termed senescence chip, for ultrahigh‐throughput isolation and removal of senescent cells. The core component of our senescence chip is a slanted and tunable 3D micropillar array with a variety of shutters in the vertical direction for rapid cell sieving, taking advantage of the characteristic cell size increase during cellular senescence. The 3D configuration achieves high throughput, high recovery rate, and device robustness with minimum clogging. We demonstrated proof‐of‐principle applications in isolation and enumeration of senescent mesenchymal stem cells (MSCs) from undiluted human whole blood, and senescent cells from mouse bone marrow after total body irradiation, with the single‐cell resolution. After scale‐up to a multilayer and multichannel structure, our senescence chip achieved ultrahigh‐throughput removal of senescent cells from human whole blood with an efficiency of over 70% at a flow rate of 300 ml/hr. Sensitivity and specificity of our senescence chips could be augmented with implementation of multiscale size separation, and identification of background white blood cells using their cell surface markers such as CD45. With the advantages of high throughput, robustness, and simplicity, our senescence chips may find wide applications and contribute to diagnosis and therapeutic targeting of cellular senescence.  相似文献   

2.
A growing body of evidence has substantiated the significance of quantitative phase imaging (QPI) in enabling cost‐effective and label‐free cellular assays, which provides useful insights into understanding the biophysical properties of cells and their roles in cellular functions. However, available QPI modalities are limited by the loss of imaging resolution at high throughput and thus run short of sufficient statistical power at the single‐cell precision to define cell identities in a large and heterogeneous population of cells—hindering their utility in mainstream biomedicine and biology. Here we present a new QPI modality, coined multiplexed asymmetric‐detection time‐stretch optical microscopy (multi‐ATOM) that captures and processes quantitative label‐free single‐cell images at ultrahigh throughput without compromising subcellular resolution. We show that multi‐ATOM, based upon ultrafast phase‐gradient encoding, outperforms state‐of‐the‐art QPI in permitting robust phase retrieval at a QPI throughput of >10 000 cell/sec, bypassing the need for interferometry which inevitably compromises QPI quality under ultrafast operation. We employ multi‐ATOM for large‐scale, label‐free, multivariate, cell‐type classification (e.g. breast cancer subtypes, and leukemic cells vs peripheral blood mononuclear cells) at high accuracy (>94%). Our results suggest that multi‐ATOM could empower new strategies in large‐scale biophysical single‐cell analysis with applications in biology and enriching disease diagnostics.   相似文献   

3.
Cell separation using methodological standards that ensure high purity is a very important step in cell transplantation for regenerative medicine and for stem cell research. A separation protocol using magnetic beads has been widely used for cell separation to isolate negative and positive cells. However, not only the surface marker pattern, e.g., negative or positive, but also the density of a cell depends on its developmental stage and differentiation ability. Rapid and label‐free separation procedures based on surface marker density are the focus of our interest. In this study, we have successfully developed an antiCD34 antibody‐immobilized cell‐rolling column, that can separate cells depending on the CD34 density of the cell surfaces. Various conditions for the cell‐rolling column were optimized including graft copolymerization, and adjustment of the column tilt angle, and medium flow rate. Using CD34‐positive and ‐negative cell lines, the cell separation potential of the column was established. We observed a difference in the rolling velocities between CD34‐positive and CD34‐negative cells on antibody‐immobilized microfluidic device. Cell separation was achieved by tilting the surface 20 degrees and the increasing medium flow. Surface marker characteristics of the isolated cells in each fraction were analyzed using a cell‐sorting system, and it was found that populations containing high density of CD34 were eluted in the delayed fractions. These results demonstrate that cells with a given surface marker density can be continuously separated using the cell rolling column. © 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2010  相似文献   

4.
The availability of preparative‐scale downstream processing strategies for cell‐based products presents a critical juncture between fundamental research and clinical development. Aqueous two‐phase systems (ATPS) present a gentle, scalable, label‐free, and cost‐effective method for cell purification, and are thus a promising tool for downstream processing of cell‐based therapeutics. Here, the application of a previously developed robotic screening platform that enables high‐throughput cell partitioning analysis in ATPS is reported. In the present case study a purification strategy for two model cell lines based on high‐throughput screening (HTS)‐data and countercurrent distribution (CCD)‐modeling, and validated the CCD‐model experimentally is designed. The obtained data are shown an excellent congruence between CCD‐model and experimental data, indicating that CCD‐models in combination with HTS‐data are a powerful tool in downstream process development. Finally, the authors are shown that while cell cycle phase significantly influences cell partitioning, cell type specific differences in surface properties are the main driving force in charge‐dependent separation of HL‐60 and L929 cells. In order to design a highly robust purification process it is, however, advisable to maintain constant growth conditions.  相似文献   

5.
Intensive research and development of electrophoresis methodology and instrumentation during past decades has resulted in unique methods widely implemented in bioanalysis. While two‐dimensional electrophoresis and denaturing polyacrylamide gel electrophoresis in sodium dodecylsulfate are still the most frequently used electrophoretic methods applied to analyses of proteins, new miniaturized capillary and microfluidic versions of electromigrational methods have been developed. High‐throughput electrophoretic instruments with hundreds of capillaries for parallel separations and laser‐induced fluorescence detection of labeled DNA strands have been of key importance for the scientific and commercial success of the Human Genome Project. Another powerful method, capillary isoelectric focusing with pressurized and pH‐driven mobilization, provides efficient separations and on‐line sensitive detection of proteins, bacteria and viruses. Electrophoretic microfluidic devices can integrate single‐cell injection, cell lysis, separation of its components and fluorescence or mass spectrometry detection. These miniaturized devices also proved the capability of single‐molecule detection.  相似文献   

6.
The efficient isolation of viable and intact circulating tumor cells (CTCs) from blood is critical for the genetic analysis of cancer cells, prediction of cancer progression, development of drugs, and evaluation of therapeutic treatments. While conventional cell separation devices utilize the size difference between CTCs and other blood cells, they fail to separate CTCs from white blood cells (WBCs) due to significant size overlap. To overcome this issue, we present a novel approach that combines curved contraction–expansion (CE) channels with dielectrophoresis (DEP) and inertial microfluidics to isolate CTCs from WBCs regardless of size overlap. This label-free and continuous separation method utilizes dielectric properties and size variation of cells for the separation of CTCs from WBCs. The results demonstrate that the proposed hybrid microfluidic channel can effectively isolate A549 CTCs from WBCs regardless of their size with a throughput of 300 μL/min, achieving a high separation distance of 233.4 μm at an applied voltage of 50 Vp–p. The proposed method allows for the modification of cell migration characteristics by controlling the number of CE sections of the channel, applied voltage, applied frequency, and flow rate. With its unique features of a single-stage separation, simple design, and tunability, the proposed method provides a promising alternative to the existing label-free cell separation techniques and may have a wide range of applications in biomedicine.  相似文献   

7.
A novel three‐dimensional hydrodynamic focusing microfluidic device integrated with high‐throughput cell sampling and detection of intracellular contents is presented. It has a pivotal role in maintaining the reducing environment in cells. Intracellular reducing species such as vitamin C and glutathione in normal and tumor cells were labeled by a newly synthesized 2,2,6,6‐tetramethyl‐piperidine‐1‐oxyl‐based fluorescent probe. Hepatocytes are adherent cells, which are prone to attaching to the channel surface. To avoid the attachment of cells on the channel surface, a single channel microchip with three sheath‐flow channels located on both sides of and below the sampling channel was developed. Hydrostatic pressure generated by emptying the sample waste reservoir was used as driving force of fluid on the microchip. Owing to the difference between the liquid levels of the reservoirs, the labeled cells were three‐dimensional hydrodynamically focused and transported from the sample reservoir to the sample waste reservoir. Hydrostatic pressure takes advantage of its ease of generation on a microfluidic chip without any external pressure pump, which drives three sheath‐flow streams to constrain a sample flow stream into a narrow stream to avoid blockage of the sampling channel by adhered cells. The intracellular reducing levels of HepG2 cells and L02 cells were detected by home‐built laser‐induced fluorescence detector. The analysis throughput achieved in this microfluidic system was about 59–68 cells/min. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
9.
基于微流控技术的微生物细胞梯度稀释分离方法   总被引:1,自引:0,他引:1  
随着微流控分析技术的快速发展,集成化的微流控芯片在满足实验高通量的同时,还在微生物细胞分离领域呈现出独特的优势。本研究基于微流控技术,制备了以聚二甲基硅氧烷(PDMS)、玻片为材料的细菌细胞梯度稀释分离芯片。该芯片的核心是通过一系列复杂的梯度网络来实现对细菌悬液的连续稀释,最终被分离的细菌细胞进入通道末端的存储孔内。结果显示,该方法能分离出的最少细菌细胞数低于10个。此芯片平台操作简单、耗时短、成本低,为微生物单细胞研究提供了新的途径。  相似文献   

10.
In industrial‐scale biotechnological processes, the active control of the pH‐value combined with the controlled feeding of substrate solutions (fed‐batch) is the standard strategy to cultivate both prokaryotic and eukaryotic cells. On the contrary, for small‐scale cultivations, much simpler batch experiments with no process control are performed. This lack of process control often hinders researchers to scale‐up and scale‐down fermentation experiments, because the microbial metabolism and thereby the growth and production kinetics drastically changes depending on the cultivation strategy applied. While small‐scale batches are typically performed highly parallel and in high throughput, large‐scale cultivations demand sophisticated equipment for process control which is in most cases costly and difficult to handle. Currently, there is no technical system on the market that realizes simple process control in high throughput. The novel concept of a microfermentation system described in this work combines a fiber‐optic online‐monitoring device for microtiter plates (MTPs)—the BioLector technology—together with microfluidic control of cultivation processes in volumes below 1 mL. In the microfluidic chip, a micropump is integrated to realize distinct substrate flow rates during fed‐batch cultivation in microscale. Hence, a cultivation system with several distinct advantages could be established: (1) high information output on a microscale; (2) many experiments can be performed in parallel and be automated using MTPs; (3) this system is user‐friendly and can easily be transferred to a disposable single‐use system. This article elucidates this new concept and illustrates applications in fermentations of Escherichia coli under pH‐controlled and fed‐batch conditions in shaken MTPs. Biotechnol. Bioeng. 2010;107: 497–505. © 2010 Wiley Periodicals, Inc.  相似文献   

11.
12.
13.
One important application of tissue engineering is to provide novel in vitro models for cell‐based assays. Perfusion microbioreactor array provides a useful tool for microscale tissue culture in parallel. However, high‐throughput data generation has been a challenge. In this study, a 4 × 4 array of perfusion microbioreactors was developed for plate‐reader compatible, time‐series quantification of cell proliferation, and cytotoxicity assays. The device was built through multilayer soft lithography. Low‐cost nonwoven polyethylene terephthalate fibrous matrices were integrated as modular tissue culture scaffolds. Human colon cancer HT‐29 cells with stable expression of enhanced green fluorescent protein were cultured in the device with continuous perfusion and reached a cell density over 5 × 107 cells/mL. The microbioreactor array was used to test a chemotherapeutic drug 5‐FU for its effect on HT‐29 cells in continuous perfusion 3D culture. Compared with conventional 2D cytotoxicity assay, significant drug resistance was observed in the 3D perfusion culture. © 2010 American Institute of Chemical Engineers Biotechnol. Prog., 2010  相似文献   

14.
Massively parallel sequencing has reduced the cost and increased the throughput of genomic sequencing by more than three orders of magnitude, and it seems likely that costs will fall and throughput improve even more in the next few years. Clinical use of massively parallel sequencing will provide a way to identify the cause of many diseases of unknown etiology through simultaneous screening of thousands of loci for pathogenic mutations and by sequencing biological specimens for the genomic signatures of novel infectious agents. In addition to providing these entirely new diagnostic capabilities, massively parallel sequencing may also replace arrays and Sanger sequencing in clinical applications where they are currently being used.Routine clinical use of massively parallel sequencing will require higher accuracy, better ways to select genomic subsets of interest, and improvements in the functionality, speed, and ease of use of data analysis software. In addition, substantial enhancements in laboratory computer infrastructure, data storage, and data transfer capacity will be needed to handle the extremely large data sets produced. Clinicians and laboratory personnel will require training to use the sequence data effectively, and appropriate methods will need to be developed to deal with the incidental discovery of pathogenic mutations and variants of uncertain clinical significance. Massively parallel sequencing has the potential to transform the practice of medical genetics and related fields, but the vast amount of personal genomic data produced will increase the responsibility of geneticists to ensure that the information obtained is used in a medically and socially responsible manner.  相似文献   

15.
Advances in microscopy with new visualization possibilities often bring dramatic progress to our understanding of the intriguing cellular machinery. Picosecond optoacoustic micro‐spectroscopy is an optical technique based on ultrafast pump‐probe generation and detection of hypersound on time durations of picoseconds and length scales of nanometers. It is experiencing a renaissance as a versatile imaging tool for cell biology research after a plethora of applications in solid‐state physics. In this emerging context, this work reports on a dual‐probe architecture to carry out real‐time parallel detection of the hypersound propagation inside a cell that is cultured on a metallic substrate, and of the hypersound reflection at the metal/cell adhesion interface. Using this optoacoustic modality, several biophysical properties of the cell can be measured in a noncontact and label‐free manner. Its abilities are demonstrated with the multiple imaging of a mitotic macrophage‐like cell in a single run experiment.   相似文献   

16.
Positive selection of CD34+ blood progenitor cells from circulation has been reported to improve patient recovery in applications of autologous transplantation. Current magnetic separation methods rely on cell capture and release on solid supports rather than sorting from flowing suspensions, which limits the range of therapeutic applications and the process scale up. We tested CD34+ cell immunomagnetic labeling and isolation from fresh leukocyte fraction of peripheral blood (leukapheresis) using the continuous quadrupole magnetic flow sorter (QMS), consisting of a flow channel (SHOT, Greenville, IN) and a quadrupole magnet with a maximum field intensity (B(o)) of 1.42 T and a mean force field strength (S(m)) of 1.45 x 10(8) TA/m(2). Both the sample magnetophoretic mobility (m) and the inlet and outlet flow patterns highly affect the QMS performance. Seven commercial progenitor cell labeling reagent combinations were quantitatively evaluated by measuring magnetophoretic mobility of a high CD34 expression cell line, KG-1a, using the cell tracking velocimeter (CTV). The CD34 Progenitor Cell Isolation Kit (Miltenyi Biotec, Bergisch Gladbach, Germany) showed the strongest labeling of KG-1a cells and was selected for progenitor cell enrichment from 11 fresh and 11 cryopreserved clinical leukapheresis samples derived from different donors. The CD34+ cells were isolated with a purity of 60-96%, a recovery of 18-60%, an enrichment rate of 12-169, and a throughput of (1.7-9.3) x 10(4) cells/s. The results also showed a highly regular dependence of the QMS performance on the flow conditions that agreed with the theoretical predictions based on the CD34+ cell magnetophoretic mobility.  相似文献   

17.
High‐throughput ‐omics techniques have revolutionised biology, allowing for thorough and unbiased characterisation of the molecular states of biological systems. However, cellular decision‐making is inherently a unicellular process to which “bulk” ‐omics techniques are poorly suited, as they capture ensemble averages of cell states. Recently developed single‐cell methods bridge this gap, allowing high‐throughput molecular surveys of individual cells. In this review, we cover core concepts of analysis of single‐cell gene expression data and highlight areas of developmental biology where single‐cell techniques have made important contributions. These include understanding of cell‐to‐cell heterogeneity, the tracing of differentiation pathways, quantification of gene expression from specific alleles, and the future directions of cell lineage tracing and spatial gene expression analysis.  相似文献   

18.
19.
We have developed a novel three‐dimensional (3D) cellular microarray platform to enable the rapid and efficient tracking of stem cell fate and quantification of specific stem cell markers. This platform consists of a miniaturized 3D cell culture array on a functionalized glass slide for spatially addressable high‐throughput screening. A microarray spotter was used to deposit cells onto a modified glass surface to yield an array consisting of cells encapsulated in alginate gel spots with volumes as low as 60 nL. A method based on an immunofluorescence technique scaled down to function on a cellular microarray was also used to quantify specific cell marker protein levels in situ. Our results revealed that this platform is suitable for studying the expansion of mouse embryonic stem (ES) cells as they retain their pluripotent and undifferentiated state. We also examined neural commitment of mouse ES cells on the microarray and observed the generation of neuroectodermal precursor cells characterized by expression of the neural marker Sox‐1, whose levels were also measured in situ using a GFP reporter system. In addition, the high‐throughput capacity of the platform was tested using a dual‐slide system that allowed rapid screening of the effects of tretinoin and fibroblast growth factor‐4 (FGF‐4) on the pluripotency of mouse ES cells. This high‐throughput platform is a powerful new tool for investigating cellular mechanisms involved in stem cell expansion and differentiation and provides the basis for rapid identification of signals and conditions that can be used to direct cellular responses. Biotechnol. Bioeng. 2010; 106: 106–118. © 2010 Wiley Periodicals, Inc.  相似文献   

20.
Copy number variations (CNVs), a common genomic mutation associated with various diseases, are important in research and clinical applications. Whole genome amplification (WGA) and massively parallel sequencing have been applied to single cell CNVs analysis, which provides new insight for the fields of biology and medicine. However, the WGA-induced bias significantly limits sensitivity and specificity for CNVs detection. Addressing these limitations, we developed a practical bioinformatic methodology for CNVs detection at the single cell level using low coverage massively parallel sequencing. This method consists of GC correction for WGA-induced bias removal, binary segmentation algorithm for locating CNVs breakpoints, and dynamic threshold determination for final signals filtering. Afterwards, we evaluated our method with seven test samples using low coverage sequencing (4∼9.5%). Four single-cell samples from peripheral blood, whose karyotypes were confirmed by whole genome sequencing analysis, were acquired. Three other test samples derived from blastocysts whose karyotypes were confirmed by SNP-array analysis were also recruited. The detection results for CNVs of larger than 1 Mb were highly consistent with confirmed results reaching 99.63% sensitivity and 97.71% specificity at base-pair level. Our study demonstrates the potential to overcome WGA-bias and to detect CNVs (>1 Mb) at the single cell level through low coverage massively parallel sequencing. It highlights the potential for CNVs research on single cells or limited DNA samples and may prove as a promising tool for research and clinical applications, such as pre-implantation genetic diagnosis/screening, fetal nucleated red blood cells research and cancer heterogeneity analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号