首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Several methods allow regional gas exchange to be inferred from imaging of regional ventilation and perfusion (V/Q) ratios. Each method measures slightly different aspects of gas exchange and has inherent advantages and drawbacks that are reviewed. Single photon emission computed tomography can provide regional measure of ventilation and perfusion from which regional V/Q ratios can be derived. PET methods using inhaled or intravenously administered nitrogen-13 provide imaging of both regional blood flow, shunt, and ventilation. Electric impedance tomography has recently been refined to allow simultaneous measurements of both regional ventilation and blood flow. MRI methods utilizing hyperpolarized helium-3 or xenon-129 are currently being refined and have been used to estimate local PaO(2) in both humans and animals. Microsphere methods are included in this review as they provide measurements of regional ventilation and perfusion in animals. One of their advantages is their greater spatial resolution than most imaging methods and the ability to use them as gold standards against which new imaging methods can be tested. In general, the reviewed methods differ in characteristics such as spatial resolution, possibility of repeated measurements, radiation exposure, availability, expensiveness, and their current stage of development.  相似文献   

2.
The assessment of the regional match between alveolar ventilation and perfusion in critically ill patients requires simultaneous measurements of both parameters. Ideally, assessment of lung perfusion should be performed in real-time with an imaging technology that provides, through fast acquisition of sequential images, information about the regional dynamics or regional kinetics of an appropriate tracer. We present a novel electrical impedance tomography (EIT)-based method that quantitatively estimates regional lung perfusion based on first-pass kinetics of a bolus of hypertonic saline contrast. Pulmonary blood flow was measured in six piglets during control and unilateral or bilateral lung collapse conditions. The first-pass kinetics method showed good agreement with the estimates obtained by single-photon-emission computerized tomography (SPECT). The mean difference (SPECT minus EIT) between fractional blood flow to lung areas suffering atelectasis was -0.6%, with a SD of 2.9%. This method outperformed the estimates of lung perfusion based on impedance pulsatility. In conclusion, we describe a novel method based on EIT for estimating regional lung perfusion at the bedside. In both healthy and injured lung conditions, the distribution of pulmonary blood flow as assessed by EIT agreed well with the one obtained by SPECT. The method proposed in this study has the potential to contribute to a better understanding of the behavior of regional perfusion under different lung and therapeutic conditions.  相似文献   

3.
We have developed a new quantitative single-photon-emission computed tomography (SPECT) method that uses (113m)In-labeled albumin macroaggregates and Technegas ((99m)Tc) to estimate the distributions of regional ventilation and perfusion for the whole lung. The multiple inert-gas elimination technique (MIGET) and whole lung respiratory gas exchange were used as physiological evaluations of the SPECT method. Regional ventilation and perfusion were estimated by SPECT in nine healthy volunteers during awake, spontaneous breathing. Radiotracers were administered with subjects sitting upright, and SPECT images were acquired with subjects supine. Whole lung gas exchange of MIGET gases and arterial Po(2) and Pco(2) gases was predicted from estimates of regional ventilation and perfusion. We found a good agreement between measured and SPECT-predicted exchange of MIGET and respiratory gases. Correlations (r(2)) between SPECT-predicted and measured inert-gas excretions and retentions were 0.99. The method offers a new tool for measuring regional ventilation and perfusion in humans.  相似文献   

4.
Three-dimensional micro computed tomography (microCT) offers the opportunity to capture images liver structures and lesions in mice with a high spatial resolution. Non-invasive microCT allows for accurate calculation of vessel tortuosity and density, as well as liver lesion volume and distribution. Longitudinal monitoring of liver lesions is also possible. However, distinguishing liver lesions from variations within a normal liver is impossible by microCT without the use of liver- or tumor-specific contrast-enhancing agents. The combination of microCT for morphologic imaging with functional imaging, such as positron emission tomography (PET) or single photon emission tomography (SPECT), offers the opportunity for better abdominal imaging and assessment of structure discrepancies visible by functional imaging.This paper describes methods of current microCT imaging options for imaging of liver lesions compared to other imaging techniques in small animals.  相似文献   

5.
《Médecine Nucléaire》2007,31(6):272-277
Nuclear neuroimaging, with single photon emission computed tomography (SPECT) or with positron emission tomography (PET), allows study of functional and neurochemical aspects of human brain. It provides in vivo informations about pathophysiology in dementia. The routinely available tracers are perfusional tracers (99mTc-HMPAO/GE Healthcare and 99mTc-ECD/BMS). In June 2006, a new indication for the DaTSCAN® (GE Healthcare) has been adopted. DaTSCAN® could now be used to help differentiate probable dementia with Lewy bodies from Alzheimer's disease. Since a few years, there have been tremendous efforts expended to develop specific radioligands for several neurochemical systems and for imaging of beta-amyloid plaques. The aim of this paper is to review the most common radiotracers for SPECT and PET brain imaging in dementia and to focus on the new tracers.  相似文献   

6.
《Médecine Nucléaire》2017,41(2):55-63
AimThe aim of this study was to assess lung scintigraphy practices in France for the diagnosis of acute pulmonary embolism, especially regarding the proportion of centers using single photon emission computed tomography (SPECT) rather than planar ventilation/perfusion (V/Q) imaging.Materials and methodsAn online survey composed of simple multiple-choice questions was distributed to the 210 french nuclear medicine departments in April and May 2014. The survey covered image acquisition, interpretation criteria for SPECT and planar images, and use of pseudoplanar images and radiopharmaceuticals. Departments were initially solicited by 2 sets of e-mails. They were subsequently contacted by phone. A single response per department was consolidated.ResultsTwo hundred nine responses were collected (participation rate: 99.5%). Sixty-seven percent of french centers indicated use of V/Q SPECT in routine practice. The first intention acquisition protocol was SPECT/CT in 34%, SPECT in 26% and V/Q planar in 34%. The most commonly used criteria for SPECT interpretation were those of the EANM (63%). Criteria used for planar interpretation were heterogeneous (EANM criteria, 39%; no standardized criteria, 28%; PIOPED, 23%). Eighty-three percent of centers used 99mTc aerosol and 17% 81mKr.ConclusionThis survey shows that SPECT has largely replaced planar imaging for PE diagnosis with lung scintigraphy. Acquisition protocols and interpretation criteria are inconsistent (especially for planar imaging).  相似文献   

7.
Systematically mapped samples cut from lungs previously labeled with intravascular and aerosol microspheres can be used to create high-resolution maps of regional perfusion and regional ventilation. With multiple radioactive or fluorescent microsphere labels available, this methodology can compare regional flow responses to different interventions without partial volume effects or registration errors that complicate interpretation of in vivo imaging measurements. Microsphere blood flow maps examined at different levels of spatial resolution have revealed that regional flow heterogeneity increases progressively down to an acinar level of scale. This pattern of scale-dependent heterogeneity is characteristic of a fractal distribution network, and it suggests that the anatomic configuration of the pulmonary vascular tree is the primary determinant of high-resolution regional flow heterogeneity. At approximately 2-cm(3) resolution, the large-scale gravitational gradients of blood flow per unit weight of alveolar tissue account for <5% of the overall flow heterogeneity. Furthermore, regional blood flow per gram of alveolar tissue remains relatively constant with different body positions, gravitational stresses, and exercise. Regional alveolar ventilation is accurately represented by the deposition of inhaled 1.0-microm fluorescent microsphere aerosols, at least down to the approximately 2-cm(3) level of scale. Analysis of these ventilation maps has revealed the same scale-dependent property of regional alveolar ventilation heterogeneity, with a strong correlation between ventilation and blood flow maintained at all levels of scale. The ventilation-perfusion (VA/Q) distributions obtained from microsphere flow maps of normal animals agree with simultaneously acquired multiple inert-gas elimination technique VA/Q distributions, but they underestimate gas-exchange impairment in diffuse lung injury.  相似文献   

8.
《Médecine Nucléaire》2007,31(4):183-192
Functional and anatomical small animal imaging represents one of the most promising tool in preclinical research capable of in vivo quantitative analysis of induced abnormalities in animal models and evaluation of metabolic, functional, and morphological consequences of genomic alterations in order to establish new therapeutic and diagnostic drugs. Among all the methods, SPECT imaging has recently benefited from numerous technological developments leading to submillimeter spatial resolutions with increasing detection sensitivity. Moreover, availability and sensitivity of single photon radiotracers are serious advantages of the method, which should play an important role in pre clinical imaging. The aim of this article is to present and discuss these small animal SPECT imaging advances.  相似文献   

9.
Chronic lung disease is a major worldwide health concern but better tools are required to understand the underlying pathologies. Ventilation/perfusion (V/Q) single photon emission computed tomography (SPECT) with per-voxel analysis allows for non-invasive measurement of regional lung function. A clinically adapted V/Q methodology was used in healthy mice to investigate V/Q relationships. Twelve week-old mice were imaged to describe normal lung function while 36 week-old mice were imaged to determine how age affects V/Q. Mice were ventilated with Technegas™ and injected with 99mTc-macroaggregated albumin to trace ventilation and perfusion, respectively. For both processes, SPECT and CT images were acquired, co-registered, and quantitatively analyzed. On a per-voxel basis, ventilation and perfusion were moderately correlated (R = 0.58±0.03) in 12 week old animals and a mean log(V/Q) ratio of −0.07±0.01 and standard deviation of 0.36±0.02 were found, defining the extent of V/Q matching. In contrast, 36 week old animals had significantly increased levels of V/Q mismatching throughout the periphery of the lung. Measures of V/Q were consistent across healthy animals and differences were observed with age demonstrating the capability of this technique in quantifying lung function. Per-voxel analysis and the ability to non-invasively assess lung function will aid in the investigation of chronic lung disease models and drug efficacy studies.  相似文献   

10.
Many lung disease processes are characterized by structural and functional heterogeneity that is not directly appreciable with traditional physiological measurements. Experimental methods and lung function modeling to study regional lung function are crucial for better understanding of disease mechanisms and for targeting treatment. Synchrotron radiation offers useful properties to this end: coherence, utilized in phase-contrast imaging, and high flux and a wide energy spectrum which allow the selection of very narrow energy bands of radiation, thus allowing imaging at very specific energies. K-edge subtraction imaging (KES) has thus been developed at synchrotrons for both human and small animal imaging. The unique properties of synchrotron radiation extend X-ray computed tomography (CT) capabilities to quantitatively assess lung morphology, and also to map regional lung ventilation, perfusion, inflammation and biomechanical properties, with microscopic spatial resolution. Four-dimensional imaging, allows the investigation of the dynamics of regional lung functional parameters simultaneously with structural deformation of the lung as a function of time. This review summarizes synchrotron radiation imaging methods and overviews examples of its application in the study of disease mechanisms in preclinical animal models, as well as the potential for clinical translation both through the knowledge gained using these techniques and transfer of imaging technology to laboratory X-ray sources.  相似文献   

11.
Cardiac positron emission tomography (PET) is yet considered as a reference imaging technique but remains poorly used in clinical practice. At the present time, the advantages of cardiac PET investigations are far to be evident, when compared with conventional tomoscintigraphy (SPECT), except for perfusion imaging in the obese and for viability assessment in case of very severe cardiac dysfunction. However, this situation might quickly move because of an enhanced availability of PET imaging, dramatic technical progresses and promising new tracers. In particular, the last-generation PET-cameras allow reaching spatial resolutions and detection sensitivities, which are now spectacularly higher than those from conventional SPECT imaging. In addition, the list mode recording allows the subsequent images reconstruction to be synchronized to cardiac cycle but also to respiratory cycle; and the quantifications of myocardial perfusion flow and of coronary flow reserve are now available in clinical routine. Furthermore, new tracers labelled with fluorine-18 are under development, especially for perfusion investigations, and kinetics properties of these new tracers are dramatically enhanced when compared with current perfusion SPECT tracers.  相似文献   

12.
Hybrid or multimodality imaging is often applied in order to take advantage of the unique and complementary strengths of individual imaging modalities. This hybrid noninvasive imaging approach can provide critical information about anatomical structure in combination with physiological function or targeted molecular signals. While recent advances in software image fusion techniques and hybrid imaging systems have enabled efficient multimodal imaging, accessing the full potential of this technique requires development of a new toolbox of multimodal contrast agents that enhance the imaging process. Toward that goal, we report the development of a hybrid probe for both single photon emission computed tomography (SPECT) and X-ray computed tomography (CT) imaging that facilitates high-sensitivity SPECT and high spatial resolution CT imaging. In this work, we report the synthesis and evaluation of a novel intravascular, multimodal dendrimer-based contrast agent for use in preclinical SPECT/CT hybrid imaging systems. This multimodal agent offers a long intravascular residence time (t(1/2) = 43 min) and sufficient contrast-to-noise for effective serial intravascular and blood pool imaging with both SPECT and CT. The colocalization of the dendritic nuclear and X-ray contrasts offers the potential to facilitate image analysis and quantification by enabling correction for SPECT attenuation and partial volume errors at specified times with the higher resolution anatomic information provided by the circulating CT contrast. This may allow absolute quantification of intramyocardial blood volume and blood flow and may enable the ability to visualize active molecular targeting following clearance from the blood.  相似文献   

13.
Single photon emission tomography (SPECT) and positron emission tomography (PET) are techniques to study in vivo neurotransmitter systems, neuroinflammation and amyloid deposits in normal human brain and in dementia. These methods used to explore the integrity of dopaminergic, cholinergic and serotonergic systems in Alzheimer's disease and in other dementias allowed to understand how the neurotransmission was modified in these disorders. Progress in the understanding of pathophysiological and clinical signs of dementia requires an evolution of the radioligands used to carry out an increasingly early and differential diagnosis in addition to monitoring the progression of disease and the effects of therapies. New emerging radiotracers for neuroinflammation or amyloid deposits are essential. In this article, new SPECT and PET tracers are presented.  相似文献   

14.
Zhou Y  Liu S 《Bioconjugate chemistry》2011,22(8):1459-1472
Alteration in mitochondrial transmembrane potential (ΔΨ(m)) is an important characteristic of cancer. The observation that the enhanced negative mitochondrial potential is prevalent in tumor cell phenotype provides a conceptual basis for development of mitochondrion-targeting therapeutic drugs and molecular imaging probes. Since plasma and mitochondrial potentials are negative, many delocalized organic cations, such as rhodamine-123 and (3)H-tetraphenylphosphonium, are electrophoretically driven through these membranes, and able to localize in the energized mitochondria of tumor cells. Cationic radiotracers, such as (99m)Tc-Sestamibi and (99m)Tc-Tetrofosmin, have been clinically used for diagnosis of cancer by single photon emission computed tomography (SPECT) and noninvasive monitoring of the multidrug resistance (MDR) transport function in tumors of different origin. However, their diagnostic and prognostic values are often limited due to their insufficient tumor localization (low radiotracer tumor uptake) and high radioactivity accumulation in the chest and abdominal regions (low tumor selectivity). In contrast, the (64)Cu-labeled phosphonium cations represent a new class of PET (positron emission tomography) radiotracers with good tumor uptake and high tumor selectivity. This review article will focus on our recent experiences in evaluation of (64)Cu-labeled phosphonium cations as potential PET radiotracers. The main objective is to illustrate the impact of radiometal chelate on physical, chemical, and biological properties of (64)Cu radiotracers. It will also discuss some important issues related to their tumor selectivity and possible tumor localization mechanism.  相似文献   

15.
Polymeric microbubbles (MBs) are gas filled particles composed of a thin stabilized polymer shell that have been recently developed as valid contrast agents for the combined use of ultrasonography (US), magnetic resonance imaging (MRI) and single photon emission computer tomography (SPECT) imaging. Due to their buoyancy, the commonly available approaches to study their behaviour in complex media are not easily applicable and their use in modern medicine requires such behaviour to be fully elucidated. Here we have used for the first time flow cytometry as a new high throughput approach that allows characterisation of the MB dispersion, prior to and after exposure in different biological media and we have additionally developed a method that allows characterisation of the strongly bound proteins adsorbed on the MBs, to fully predict their biological behaviour in biological milieu.  相似文献   

16.
Over the last decade, a large number of radiotracers have been developed to image and quantify transporter availability with positron emission tomography (PET) or single-photon emission computed tomography (SPECT). Radiotracers suitable to image dopamine transporters (DATs) and serotonin transporters (SERTs) have been the object of most efforts. Following a brief overview of DAT and SERT radiotracers that have been demonstrated to be suitable for quantitative analysis in vivo, this article describes the principal methods that have been used for the analysis of these data. Kinetic modeling is the most direct implementation of the compartment models, but with some tracers accurate input function measurement and good compartment configuration identification can be difficult to obtain. Other methods were designed to overcome some particular vulnerability to error of classic kinetic modeling, but introduced new vulnerabilities in the process. Reference region methods obviate the need for arterial plasma measurement, but are not as robust to violations of the underlying modeling assumptions as methods using the arterial input function. Graphical methods give estimates of distribution volumes without the requirement of compartment model specification, but provide a biased estimator in the presence of statistical noise. True equilibrium methods are quite robust, but their use is limited to experiments with tracers that are suitable for constant infusion. In conclusion, no universally "best" method is applicable to all neurotransporter imaging studies, and careful evaluation of model-based methods is required for each radiotracer.  相似文献   

17.
To determine the spatial distributions of pulmonary perfusion, shunt, and ventilation, we developed a compartmental model of regional (13)N-labeled molecular nitrogen ((13)NN) kinetics measured from positron emission tomography (PET) images. The model features a compartment for right heart and pulmonary vasculature and two compartments for each region of interest: 1) aerated alveolar units and 2) alveolar units with no gas content (shunting). The model was tested on PET data from normal animals (dogs and sheep) and from animals with experimentally injured lungs simulating acute respiratory distress syndrome. The analysis yielded estimates of regional perfusion, shunt fraction, and specific ventilation with excellent goodness-of-fit to the data (R(2) > 0.99). Model parameters were estimated to within 10% accuracy in the presence of exaggerated levels of experimental noise by using a Monte Carlo sensitivity analysis. Main advantages of the present model are that 1) it separates intraregional blood flow to aerated alveolar units from that shunting across nonaerated units and 2) it accounts and corrects for intraregional tracer removal by shunting blood when estimating ventilation from subsequent washout of tracer. The model was thus found to provide estimates of regional parameters of pulmonary function in sizes of lung regions that could potentially approach the intrinsic resolution for PET images of (13)NN in lung (approximately 7.0 mm for a multiring PET camera).  相似文献   

18.
From the first measurements of the distribution of pulmonary blood flow using radioactive tracers by West and colleagues (J Clin Invest 40: 1-12, 1961) allowing gravitational differences in pulmonary blood flow to be described, the imaging of pulmonary blood flow has made considerable progress. The researcher employing modern imaging techniques now has the choice of several techniques, including magnetic resonance imaging (MRI), computerized tomography (CT), positron emission tomography (PET), and single photon emission computed tomography (SPECT). These techniques differ in several important ways: the resolution of the measurement, the type of contrast or tag used to image flow, and the amount of ionizing radiation associated with each measurement. In addition, the techniques vary in what is actually measured, whether it is capillary perfusion such as with PET and SPECT, or larger vessel information in addition to capillary perfusion such as with MRI and CT. Combined, these issues affect quantification and interpretation of data as well as the type of experiments possible using different techniques. The goal of this review is to give an overview of the techniques most commonly in use for physiological experiments along with the issues unique to each technique.  相似文献   

19.
《Médecine Nucléaire》2007,31(6):329-336
Positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging are very useful for the management of patients with medically refractory partial epilepsy. Presurgical evaluation of patients with medically refractory partial epilepsy often included PET imaging using FDG. The use of SPECT in these patients adds some more information and gives the clinicians the possibility of having ictal imaging. Furthermore, PET and SPECT imaging are performed to better understand the pathophysiology of epilepsy.  相似文献   

20.
Neuroimaging techniques have evolved over the past several years giving us unprecedented information about the degenerative process in Parkinson's disease (PD) and other movement disorders. Functional imaging approaches such as positron emission tomography (PET) and single photon emission computerised tomography (SPECT) have been successfully employed to detect dopaminergic dysfunction in PD, even while at a preclinical stage, and to demonstrate the effects of therapies on function of intact dopaminergic neurons within the affected striatum. PET and SPECT can also monitor PD progression as reflected by changes in brain levodopa and glucose metabolism and dopamine transporter binding. Structural imaging approaches include magnetic resonance imaging (MRI) and transcranial sonography (TCS). Recent advances in voxel-based morphometry and diffusion-weighted MRI have provided exciting potential applications for the differential diagnosis of parkinsonian syndromes. Substantia nigra hyperechogenicity, detected with TCS, may provide a marker of susceptibility to PD, probably reflecting disturbances of iron metabolism, but does not appear to correlate well with disease severity or change with disease progression. In the future novel radiotracers may help us assess the involvement of non-dopaminergic brain pathways in the pathology of both motor and non-motor complications in PD.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号