首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Caffeic acid phenethyl ester (CAPE) is one of the most bioactive compounds of propolis, a resinous substance collected and elaborated by honeybees. A new liquid chromatography-electrospray ionisation tandem mass spectrometric method was developed and validated for its determination in rat plasma and urine, using taxifolin as internal standard. After sample preparation by liquid/liquid extraction with ethyl acetate, chromatographic separations were carried out with an ODS-RP column using a binary mobile phase gradient of acetonitrile in water. Detection was performed using a turboionspray source operated in negative ion mode and by multiple reaction monitoring. The method was validated, showing good selectivity, sensitivity (LOD = 1 ng/ml), linearity (5-1000 ng/ml; r > or = 0.9968), intra- and inter-batch precision and accuracy (< or =14.5%), and recoveries (94-106%) in both plasma and urine. Stability assays have shown that CAPE is rapidly hydrolysed by plasmatic esterases, which are however inhibited by sodium fluoride. The method was applied to the determination of CAPE levels in rat plasma and urine after oral administration, showing that CAPE is rapidly absorbed and excreted in urine both as unmodified molecule and as glucuronide conjugate.  相似文献   

2.
A sensitive bio-analytical assay in plasma of the depsipeptide aplidine is reported, based on reversed-phase liquid chromatography and fluorescence detection of the trans-4′-hydrazino-2-stilbazole (4′H2S) derivative of the analyte. At ambient temperature, two conformations of the depsipeptide are observed in solution due to cistrans isomerism at the proline–pyruvoyl peptide bond. Aplidine is isolated from the matrix by solid-phase extraction on an octadecyl modified silica stationary phase. After evaporation of the acetone eluate, a derivatization with 4′H2S is performed in a water–acetonitrile mixture at pH 4. The reaction mixture is injected directly into the chromatograph and the analyte is quantified by fluorescence detection at 410 and 560 nm for excitation and emission, respectively. The method has been validated in the 2–100 ng/ml-range, 2 ng/ml being the lower limit of quantification. Precision and accuracy both meet the current requirements for a bioanalytical assay. The identity of the 4′H2S reaction products of aplidine have been confirmed by mass spectrometric analysis. Finally, the method has been employed for a pilot pharmacokinetic study of aplidine in mice which demonstrated its usefulness for pharmacological research.  相似文献   

3.
Karenitecin is a novel, highly lipophilic camptothecin derivative with potent anticancer potential. We have developed a sensitive high-performance liquid chromatographic method for the determination of karenitecin concentration in human plasma and urine. Karenitecin was isolated from human plasma and urine using solid-phase extraction. Separation was achieved by gradient elution, using a water and acetonitrile mobile phase, on an ODS analytical column. Karenitecin was detected using fluorescence detection at excitation and emission wavelengths of 370 and 490 nm, respectively. Retention time for karenitecin was 16.2±0.5 min and 8.0±0.2 min for camptothecin, the internal standard. The karenitecin peak was baseline resolved, with the nearest peak at 3.1 min distance. Using normal volunteer plasma and urine from multiple individuals, as well as samples from the 50 patients analyzed to date, no interfering peaks were detected. Inter- and intra-day coefficients of variance were <4.4 and 7.1% for plasma and <4.9 and 11.6% for urine. Assay precision, based on an extracted karenitecin standard plasma sample of 2.5 ng/ml, was +4.46% with a mean accuracy of 92.4%. For extracted karenitecin standard urine samples of 2.5 ng/ml assay precision was +2.35% with a mean accuracy of 99.5%. The mean recovery of karenitecin, at plasma concentrations of 1.0 and 50 ng/ml, was 81.9 and 87.8% respectively. In urine, at concentrations of 1.5 and 50 ng/ml, the mean recoveries were 90.3 and 78.4% respectively. The lower limit of detection (LLD) for karenitecin was 0.5 ng/ml in plasma and 1.0 ng/ml in urine. The lower limit of quantification (LLQ) for karenitecin was 1 ng/ml and 1.5 ng/ml for plasma and urine, respectively. Stability studies indicate that when frozen at −70°C, karenitecin is stable in human plasma for up to 3 months and in human urine for up to 1 month. This method is useful for the quantification of karenitecin in plasma and urine samples for clinical pharmacology studies in patients receiving this agent in clinical trials.  相似文献   

4.
A simple, rapid, sensitive and selective method has been developed for the stereospecific determination of verapamil and its metabolite, norverapamil in urine. For sample preparation we utilized a membrane-based solid-phase extraction (SPE) disk consisting of a thin, particle-loaded membrane inserted in a plastic syringe-like barrel. The particles, which may be C8 or C18 bonded phase (C8 in this work), are embedded within a matrix of PTFE (Teflon) fibrils. Overall analyte recoveries were above 85%, even at low concentration of 3.0 ng/ml with reproducibilities (C.V. values) below 13.1%. This method of extraction has the advantage of speed and considerable reduction in solvent volumes compared to conventional SPE and solvent extraction. The separation of all the enantiomers was achieved using a single chiral stationary phase column, the cellulose-based reversed-phase, Chiralcel OD-R. Analyte concentrations of less than 3.0 ng/ml could be quantitated with C.V. values below 14%. Calibration curves were linear in the range 2.5–300 ng/ml. Intra-day and inter-day reproducibilities were 10.5–14.2% at 3 ng/ml, 4.8–9.3% at 138.5 ng/ml and 7.8–10.1% at 280 ng/ml level, respectively, for all the enantiomers.  相似文献   

5.
The present study describes the simultaneous determination of seven different kinds of local anesthetics and one metabolite by GC–MS with solid-state extraction: Mepivacaine, propitocaine, lidocaine, procaine (an ester-type local anesthetics), cocaine, tetracaine (an ester-type local anesthetics), dibucaine (Dib) and monoethylglycinexylidide (a metabolite of lidocaine) were clearly separated from each other and simultaneously determined by GC–MS using a DB-1 open tubular column. Their recoveries ranged from 73–95% at the target concentrations of 1.00, 10.0 and 100 μg/ml in plasma, urine and water. Coefficients of variation of the recoveries ranged from 2.3–13.1% at these concentrations. The quantitation limits of the method were approximately 100 ng/ml for monoethylglycinexylidide, propitocaine, procaine, cocaine, tetracaine and dibucaine, and 50 ng/ml for lidocaine and mepivacaine. This method was applied to specimens of patients who had been treated with drip infusion of lidocaine, and revealed that simultaneous determination of lidocaine and monoethylglycinexylidide in the blood and urine was possible.  相似文献   

6.
Solid-phase microextraction (SPME) is a unique extraction and sampling technique, and it has been used for separation of volatile organics from water or other simple matrices. In this study, we have used SPME to separate dinitroaniline herbicides from complicated matrices of human urine and blood in order to broaden its application to biomedical analysis. The SPME conditions were optimized for water, urine and blood samples, in terms of pH, salt additives, extraction temperature, and fiber exposure time. Urine or water (1.0 ml) spiked with herbicides and 0.28 g of anhydrous sodium sulfate was preheated at 70°C for 10 min, and a polydimethylsiloxane-coated fiber for SPME was exposed to the headspace at 70°C for another 30 min; while spiked blood (0.5 ml) diluted with water (0.5 ml) was treated at 90°C in the same way. The herbicides were extractable under these conditions, and could be determined by gas chromatography–electron capture detector (GC–ECD). The recoveries of the herbicides, measured at the concentrations of 0.50 and 1.0 ng/ml urine or water, or 6.0 and 20 ng/0.5 ml blood, ranged from 35 to 64% for different herbicides from water or urine, and from 3.2 to 7.2% from blood. The headspace SPME yielded clean extracts of dinitroaniline herbicides from urine, blood or water, which could be directly analyzed by GC–ECD without further purification. The peak areas of the extracted herbicides were proportional to their concentrations in the range 0.1–10 ng/ml in water or urine, or 1–60 ng/0.5 ml in blood. The lowest detectable concentration of the herbicides lay in 0.1 ng/ml water or urine, or in 0.5 ng/0.5 ml blood. The intra- and inter-day coefficients of variation were within 14% for most of the analytes. Although the recoveries of the herbicides were rather low, the linearity of calibration curve and the precision were good. The developed method is more sensitive and much simpler in sample preparation than previously reported ones. With the established SPME method, a dosed herbicide was successfully separated and determined in rats' blood.  相似文献   

7.
We present a method for the enantioselective analysis of propafenone in human plasma for application in clinical pharmacokinetic studies. Propafenone enantiomers were resolved on a 10-μm Chiralcel OD-R column (250×4.6 mm I.D.) after solid-phase extraction using disposable solid-phase extraction tubes (RP-18). The mobile phase used for the resolution of propafenone enantiomers and the internal standard propranolol was 0.25 M sodium perchlorate (pH 4.0)–acetonitrile (60:40, v/v), at a flow-rate of 0.7 ml/min. The method showed a mean recovery of 99.9% for (S)-propafenone and 100.5% for (R)-propafenone, and the coefficients of variation obtained in the precision and accuracy study were below 10%. The proposed method presented quantitation limits of 25 ng/ml and was linear up to a concentration of 5000 ng/ml of each enantiomer.  相似文献   

8.
This paper describes the development of a simple and sensitive analytical method for the quantification of melatonin in human plasma and rabbit serum, using standard analytical equipment and on-line column enrichment without prior extraction, clean-up or derivatization. The analytical procedure was found to be accurate, precise and linear. For human plasma, the accuracy was 101% (range 89–106%), and the mean precision was 5% (range 2–9%) for all concentrations (0, 2, 10, 50 and 200 ng/ml) tested (n=6). The accuracy in rabbit serum was 101% (range 90–112%), and the mean precision was 13% (range 8–19%) for all concentrations (0, 2, 10, 50, 200 and 500 ng/ml) tested (n=6). The retention time of melatonin was about 8 min and the total recoveries were found to be approximately 65 and 85%, respectively, for human plasma and rabbit serum. The limit of detection was found to be lower than 1 ng/ml for human plasma and around 2 ng/ml for rabbit serum. The method is, therefore, found to be suitable for melatonin bioavailability studies in rabbits and presumably also in humans.  相似文献   

9.
Camptothecins are indole alkaloids isolated from a Chinese tree, Camptotheca acuminata, and have a wide spectrum of anticancer activity in vitro and in vivo. A novel camptothecin congener 10-hydroxycamptothecin (HCPT) has been shown to be more active and less toxic than camptothecin, and the lactone HCPT is believed to be responsible for its anticancer activity. In the present study, a reversed-phase high-performance liquid chromatography (HPLC) with fluorescence detection was developed and validated for the simulataneous analysis of HCPT for lactone form (I) and carboxylate form (II) in plasma, urine and feces and tissues. Biological samples were prepared by a liquid-liquid extraction method using ice-cold methanol-acetonitrile (1:1, v/v). This method was shown to be reproducible and reliable, with intra- and inter-day variations being less than 7%, and accuracy being 94.3%–102.7%. The limits of determination were 2 ng/ml, 2 ng/ml, 2 ng/g, and 10 ng/ml for HCPT forms I and II in rat plasma, urine, feces, and tissues, respectively. The assay was liner over the range 2–2000 ng/ml (r=0.999, P<0.001) with recoveries of greater than 90% for plasma and urine and approximately 70–80% for feces and tissues homogenates through the extraction procedure. This analytic procedure has been successfully applied to a pharmacokinetic study of HCPT in experimental animals and should be useful in the future human studies.  相似文献   

10.
A rapid, selective and sensitive HPLC–tandem mass spectrometry method was developed and validated for simultaneous determination of flupirtine and its active metabolite D-13223 in human plasma. The analytes and internal standard diphenhydramine were extracted from plasma samples by liquid–liquid extraction, and chromatographed on a C18 column. The mobile phase consisted of acetonitrile–water–formic acid (60:40:1, v/v/v), at a flow rate of 0.5 ml/min. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI). The method has a limit of quantitation of 10 ng/ml for flupirtine and 2 ng/ml for D-13223, using 0.5-ml plasma sample. The linear calibration curves were obtained in the concentration range of 10.0–1500.0 ng/ml for flupirtine and 2.0–300.0 ng/ml for D-13223. The intra- and inter-run precision (RSD), calculated from quality control (QC) samples was less than 7.2% for flupirtine and D-13223. The accuracy as determined from QC samples was less than 5% for the analytes. The overall extraction recoveries of flupirtine and D-13223 were determined to be about 66% and 78% on average, respectively. The method was applied for the evaluation of the pharmacokinetics of flupirtine and active metabolite D-13223 in volunteers following peroral administration.  相似文献   

11.
An analytical method for the determination of lycopene in tissues and plasma of rats is described. The method was validated for the determination of lycopene in liver and plasma with respect to selectivity, linearity, accuracy, recovery and precision. Following precipitation of proteins with water–ethanol plasma was extracted with hexane; tissues were extracted with acetone followed by precipitation of proteins with water–ethanol and extraction of lycopene with hexane. Separation and quantification of geometrical isomers of lycopene was achieved by normal-phase HPLC with UV/VIS detection at 471 nm. The method proved to be selective and specific for lycopene in plasma and liver. Detector response was linear in the range from 2 ng/g to 10 μg/g liver and 0.5 ng/ml to 2 μg/ml plasma, respectively. Average recoveries ranged from 96 to 101% in spiked liver samples and from 91 to 94% in spiked plasma samples. Intra-day variability (C.V.) was ≤6% and ≤5% in liver and plasma, respectively. Inter-day precision was ≤9% for liver samples and ≤6% for plasma samples. The procedures were successfully applied to the sample analysis of pharmacokinetic and metabolism studies.  相似文献   

12.
[Arg6, -Trp7,9, mePhe8]-substance P (6–11), code-named antagonist G, is a novel peptide currently undergoing early clinical trials as an anticancer drug. A sensitive, high efficiency high-performance liquid chromatography (HPLC) method is described for the determination in human plasma of antagonist G and its three major metabolites, deamidated-G (M1), G-minus Met11 (M2) and G[Met11(O)] (M3). Gradient elution was employed using 40 mM ammonium acetate in 0.15% trifluoroacetic acid as buffer A and acetonitrile as solvent B, with a linear gradient increasing from 30 to 100% B over 15 min, together with a microbore analytical column (μBondapak C18, 30 cm×2 mm I.D.). Detection was by UV at 280 nm and the column was maintained at 40°C. Retention times varied by <1% throughout the day and were as follows: G, 13.0 min; M1, 12.2 min; M2, 11.2 min; M3, 10.8 min, and 18.1 min for a pyrene conjugate of G (G–P). The limit of detection on column (LOD) was 2.5 ng for antagonist G, M1–3 and G–P and the limit of quantitation (LOQ) was 20 ng/ml for G and 100 ng/ml for M1–3. Sample clean-up by solid-phase extraction using C2-bonded 40 μm silica particles (Bond Elut, 1 ml reservoirs) resulted in elimination of interference from plasma constituents. Within-day and between-day precision and accuracy over a broad range of concentrations (100 ng/ml–100 μg/ml) normally varied by <10%, although at the highest concentrations of M1 and M2 studied (50 μg/ml), increased variability and reduced recovery were observed. The new assay will aid in the clinical development of antagonist G.  相似文献   

13.
A modified gas chromatographic—mass spectrometric (GC—MS) assay has been developed to quantitate metoclopramide (MCP) and two of its metabolites [monodeethylated-MCP (mdMCP), dideethylated-MCP (ddMCP)] in the plasma, bile and urine of sheep. The heptafluorobutyryl derivatives of the compounds were formed and quantitated using electron-impact ionization in the selected-ion monitoring mode (MCP, m/z 86, 380; mdMCP, m/z 380 and ddMCP, m/z 380). No interference was observed from endogenous compounds following the extraction of various biological fluids obtained from non-pregnant sheep. Sample preparation has been simplified and the method is more selective and sensitive (2 fold) than our previous assay using electron-capture detection. The limit of quantitation for MCP, mdMCP and ddMCP was 1 ng/ml in plasma, urine and bile, requiring 0.5 ml of sample. This represents 2.5 pg of the analytes at the detector. The standard curves were linear over a working range of 1–40 ng/ml. Absolute recoveries in plasma ranged from 76.5–94.7%, 79.2–96.8%, 80.3–102.2% for MCP, mdMCP and ddMCP, respectively. In urine, recoveries ranged from 56.5–87.8%, 61.5–87.5%, 62.6–90.2% for MCP, mdMCP and ddMCP, respectively. Recoveries in bile ranged from 83.5–100.9%, 78.5–90.5%, 66.9–79.2% for MCP, mdMCP and ddMCP, respectively. Overall intra-day precision ranged from 2.9% for MCP in plasma to 12.6% for mdMCP in bile. Overall inter-day precision ranged from 5.9% for MCP in urine to 14.9% for ddMCP in bile. Bias was the greatest at the 1 ng/ml concentration in all biological fluids ranging from a low of 2.4% for mdMCP in plasma to a high of 11.9% for ddMCP in urine. Applicability of the assay for pharmacokinetic studies of MCP, mdMCP and ddMCP in the plasma and urine of a non-pregnant ewe is demonstrated.  相似文献   

14.
Olanzapine is a commonly used atypical antipsychotic medication for which therapeutic drug monitoring has been proposed as clinically useful. A sensitive method was developed for the determination of olanzapine concentrations in plasma and urine by high-performance liquid chromatography with low-wavelength ultraviolet absorption detection (214 nm). A single-step liquid–liquid extraction procedure using heptane-iso-amyl alcohol (97.5:2.5 v/v) was employed to recover olanzapine and the internal standard (a 2-ethylated olanzapine derivative) from the biological matrices which were adjusted to pH 10 with 1 M carbonate buffer. Detector response was linear from 1–5000 ng (r2>0.98). The limit of detection of the assay (signal:noise=3:1) and the lower limit of quantitation were 0.75 ng and 1 ng/ml of olanzapine, respectively. Interday variation for olanzapine 50 ng/ml in plasma and urine was 5.2% and 7.1% (n=5), respectively, and 9.5 and 12.3% at 1 ng/ml (n=5). Intraday variation for olanzapine 50 ng/ml in plasma and urine was 8.1% and 9.6% (n=15), respectively, and 14.2 and 17.1% at 1 ng/ml (n=15). The recoveries of olanzapine (50 ng/ml) and the internal standard were 83±6 and 92±6% in plasma, respectively, and 79±7 and 89±7% in urine, respectively. Accuracy was 96% and 93% at 50 and 1 ng/ml, respectively. The applicability of the assay was demonstrated by determining plasma concentrations of olanzapine in a healthy male volunteer for 48 h following a single oral dose of 5 mg olanzapine. This method is suitable for studying olanzapine disposition in single or multiple-dose pharmacokinetic studies.  相似文献   

15.
We describe a novel sensitive and simplified gradient HPLC assay for quantification of the immunosuppressant mycophenolic acid (MPA) in rat and human plasma. In contrast to previously reported MPA assays, our method used a single step extraction comprising addition of acetonitrile, which contained phenolphthalein glucoronic acid as internal standard, for protein precipitation. Linearity: 0.1–100 μg/ml (r2>0.999), mean recoveries: MPA 98.0%, internal standard 105.2%, mean intra-day precision: 4.3%, mean day-to-day precision: 4.3%, mean day-to-day accuracy: −1.5%. Sensitivity was sufficient to allow for quantification of mycophenolic acid in as little as 50 μl plasma.  相似文献   

16.
A rapid, simple method for the measurement of paroxetine in human plasma by reversed-phase high-performance liquid chromatography (HPLC) with fluorescence detection is described. This method includes only one-step extraction of paroxetine and dibucaine, an internal standard, with chloroform. Their recoveries were around 90%. The mobile phase, 10 mM phosphate buffer–acetonitrile (40:60, v/v) was eluted isocratically. Between- and within-day coefficients of variation were in the range of 1.9–9.4% and 2.3–13.3%, respectively. The detection limit was 0.2 ng/ml. The method we describe can be easily applied to the measurement of plasma paroxetine concentration for pharmacokinetic studies as well as for therapeutic drug monitoring in patients taking paroxetine.  相似文献   

17.
A sensitive, selective and reproducible reversed-phase HPLC method with ultraviolet detection was developed for the quantification of diazepam in small plasma samples from children with severe malaria. The method involves plasma deproteinization with acetonitrile, followed by liquid–liquid extraction with ethyl acetate–n-hexane. Diazepam was eluted at ambient temperatures from a reversed-phase C18 column with an acidic (pH 3.5) aqueous mobile phase (10 mM KH2PO4–acetonitrile, 69:31, v/v). Calibration curves in spiked plasma were linear from 10 to 200 ng (r2≥0.99). The limit of detection was 5.0 ng/ml, and relative recoveries at 25 and 180 ng were >87%. Intra- and inter-assay relative standard deviations were <15%. There was no interference from drugs commonly administered to children with severe malaria (phenobarbitone, phenytoin, chloroquine, quinine, sulfadoxine, pyrimethamine, halofantrine, cycloguanil, chlorcycloguanil, acetaminophen and salicylate). This method has been used for monitoring plasma diazepam concentrations in children with seizures associated with severe malaria.  相似文献   

18.
CPT-11 {I; 7-ethyl-10-[4-(1-piperidino)-1-piperidino]carbonyloxycamptothecin} is a new anticancer agent currently under clinical development. A sensitive high-performance liquid chromatographic assay suitable for the simultaneous determination of I and its active metabolite SN-38 (II) in human plasma, and their preliminary clinical pharmacokinetics, are described. Plasma samples were processed using a solid-phase (C18) extraction step allowing mean recoveries of I, II and the internal standard camptothecin (III) of 84, 99 and 72%, respectively. The extracts were chromatographed on a C18 reversed-phase column with a mobile phase composed of acetonitrile, phosphate buffer and heptanesulphonic acid, with fluorescence detection. The calibration graphs were linear over a wide range of concentrations (1 ng/ml–10 μg/ml), and the lower limit of determination was 1 ng/ml for both I and II. The method showed good precision: the within-day relative standard deviation (R.S.D.) (5–1000 ng/ml) was 13.0% (range 4.9–19.4%) for I and 12.8% (6.7–19.1%) for II; the between-day R.S.D. (5–10 000 ng/ml was 7.9% (5.4–17.5%) for I and 9.7% (3.5–15.1%) for II. Using this assay, plasma pharmacokinetics of both I and II were simultaneously determined in three patients receiving 100 mg/m2 I as a 30-min intravenous infusion. The mean peak plasma concentration of I at the end of the intravenous infusion was 2400 ± 285 ng/ml (mean ± standard error of the mean). Plasma decay was triphasic with half-lives α, β and γ of 5.4 ± 1.8 min, 2.5 ± 0.5 h and 20.2 ± 4.6 h, respectively. The volume of distribution at steady state was 105 ± 15 l/m2, and the total body clearance was 12.5 ± 1.9 l/h · m2. The maximum concentrations of the active metabolite II reached 36 ± 11 ng/ml.  相似文献   

19.
A chromatographic method for the quantitation of promethazine (PMZ) and its three metabolites in urine employing on-line solid-phase extraction and column-switching has been developed. The column-switching system described here uses an extraction column for the purification of PMZ and its metabolites from a urine matrix. The extraneous matrix interference was removed by flushing the extraction column with a gradient elution. The analytes of interest were then eluted onto an analytical column for further chromatographic separation using a mobile phase of greater solvent strength. This method is specific and sensitive with a range of 3.75–1400 ng/ml for PMZ and 2.5–1400 ng/ml for the metabolites promethazine sulfoxide, monodesmethyl promethazine sulfoxide and monodesmethyl promethazine. The lower limits of quantitation (LLOQ) were 3.75 ng/ml with less than 6.2% C.V. for PMZ and 2.50 ng/ml with less than 11.5% C.V. for metabolites based on a signal-to-noise ratio of 10:1 or greater. The accuracy and precision were within ±11.8% in bias and not greater than 5.5% C.V. in intra- and inter-assay precision for PMZ and metabolites. Method robustness was investigated using a Plackett–Burman experimental design. The applicability of the analytical method for pharmacokinetic studies in humans is illustrated.  相似文献   

20.
A rapid, selective and very sensitive ion-pairing reversed-phase HPLC method was developed for the simultaneous determination of trimebutine (TMB) and its major metabolite, N-monodesmethyltrimebutine (NDTMB), in rat and human plasma. Heptanesulfonate was employed as the ion-pairing agent and verapamil was used as the internal standard. The method involved the extraction with a n-hexane–isopropylalcohol (IPA) mixture (99:1, v/v) followed by back-extraction into 0.1 M hydrochloric acid and evaporation to dryness. HPLC analysis was carried out using a 4-μm particle size, C18-bonded silica column and water–sodium acetate–heptanesulfonate–acetonitrile as the mobile phase and UV detection at 267 nm. The chromatograms showed good resolution and sensitivity and no interference of plasma. The mean recoveries for human plasma were 95.4±3.1% for TMB and 89.4±4.1% for NDTMB. The detection limits of TMB and its metabolite, NDTMB, in human plasma were 1 and 5 ng/ml, respectively. The calibration curves were linear over the concentration range 10–5000 ng/ml for TMB and 25–25000 ng/ml for NDTMB with correlation coefficients greater than 0.999 and with within-day or between-day coefficients of variation not exceeding 9.4%. This assay procedure was applied to the study of metabolite pharmacokinetics of TMB in rat and the human.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号