首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Chemical sensors utilizing immobilized enzymes and proteins are important for monitoring chemical processes and biological systems. In this study, calcium-cross-linked alginate hydrogel microspheres were fabricated as enzyme carriers by an emulsification technique. Glucose oxidase (GOx) was encapsulated in alginate microspheres using three different methods: physical entrapment (emulsion), chemical conjugation (conjugation), and a combination of physical entrapment and chemical conjugation (emulsion-conjugation). Nano-organized coatings were applied on alginate/GOx microspheres using the layer-by-layer self-assembly technique in order to stabilize the hydrogel/enzyme system under biological environment. The encapsulation of GOx and formation of nanofilm coating on alginate microspheres were verified with FTIR spectral analysis, zeta-potential analysis, and confocal laser scanning microscopy. To compare both the immobilization properties of enzyme encapsulation techniques and the influence of nanofilms with uncoated microspheres, the relationship between enzyme loading, release, and effective GOx activity (enzyme activity per unit protein loading) were studied over a period of four weeks. The results produced four key findings: (1) the emulsion-conjugation technique improved the stability of GOx in alginate microspheres compared to the emulsion technique, reducing the GOx leaching from microsphere from 50% to 17%; (2) the polyelectrolyte nanofilm coatings increased the GOx stability over time, but also reduced the effective GOx activity; (3) the effective GOx activity for the emulsion-conjugation technique (about 3.5 x 10(-)(5) AU microg(-)(1) s(-)(1)) was higher than that for other methods, and did not change significantly over four weeks; and (4) the GOx concentration, when compared after one week for microspheres with three bilayers of poly(allylamine hydrochloride)/sodium poly(styrene sulfonate) ({PAH/PSS}) coating, was highest for the emulsion-conjugation technique. As a result, the comparison of these three techniques showed the emulsion-conjugation technique to be a potentially effective and practical way to fabricate alginate/GOx microspheres for implantable glucose biosensor application.  相似文献   

2.
Systems for glucose monitoring based on resonance energy transfer (RET) and competitive binding using Concanavalin A (Con A) are problematic as a result of problems of toxicity, aggregation, and irreversible binding. This paper presents an improved RET assay wherein Con A was replaced by apo-glucose oxidase (apo-GOx). The basic principle for transduction is identical to that used in assays based on Con A-dextran: a reduction in RET from fluorescein isothiocyanate (FITC) to tetramethyl rhodamine isothiocyanate (TRITC) occurs when FITC-dextran (donor) is displaced from TRITC-apo-GOx (acceptor) as a result of the competition of glucose. Fluorescence measurements confirm that the apo-GOx/dextran complexes are highly sensitive to glucose, measured as an increase in the donor peak relative to acceptor due to stepwise addition of glucose. The solution-phase assay showed strong signals and excellent repeatability, with a sensitivity of 0.0163 (ratio units)/mM over the range of 0-90 mM glucose. If properly encapsulated, these sensors can potentially be used for in vivo sensing without the concern of toxicity associated with Con A.  相似文献   

3.
An amperometric glucose biosensor with glucose oxidase (GOx) immobilized into palladium hexacyanoferrate (PdHCF) hydrogel has been prepared and evaluated. The sensor was based on a two-layer configuration with biocatalytic and electrocatalytic layers separately deposited onto the electrode. To reduce the overpotential for reduction of hydrogen peroxide liberated in the enzyme catalyzed oxidation of glucose, an inner thin layer of nickel hexacyanoferrate (NiHCF) electrodeposited onto the surface of graphite electrode was used as an electrocatalyst. As an outer layer, the hydrogel of palladium hexacyanoferrate with entrapped glucose oxidase was used. Under optimal operating conditions (pH 5.0 and E = -0.075 V versus calomel (3.0 M KCl) reference electrode), sensor showed high sensitivity to glucose (0.3-1.0 microA/mM) and a response time of less than 30s. The linear response to glucose was obtained in the concentration range between 0.05 and 1.0 mM in batch analysis mode and 0-7.0 mM in FIA. During the 32 days testing period, no significant decrease in the sensor sensitivity was observed. The sensor was applied for the determination of glucose concentration in fruit juice and yoghurt drink, and the results obtained showed good correlation with results obtained by reference spectrophotometric enzyme method.  相似文献   

4.
We report on an amperometric biosensor that is based on a nanocomposite of carbon nanotubes (CNT), a nano-thin plasma-polymerized film (PPF), and glucose oxidase (GOx) as an enzyme model. A mixture of the GOx and a CNT film is sandwiched with 10-nm-thick acetonitrile PPFs. Under PPF layer was deposited onto a sputtered gold electrode. To facilitate the electrochemical communication between the CNT layer and GOx, CNT was treated with nitrogen or oxygen plasma. The resulting device showed that the oxidizing current response due to enzymatic reaction was 4-16-fold larger than that with only CNT or PPF, showing that the PPF and/or plasma process is an enzyme-friendly platform for designing electrochemical communication from the reaction center of GOx to the electrode via CNTs. The optimized glucose biosensor showed high sensitivity (sensitivity of 42 microA mM(-1)cm(-2), correlation coefficient of 0.992, linear response range of 0.025-2.2 mM, and a detection limit of 6 microM at signal/noise ratio of 3, +0.8 V versus Ag/AgCl), high selectivity (almost no interference by 0.5 mM ascorbic acid) for glucose quantification, and rapid response (<4 s to reach 95% of maximum response). Additionally, the devices showed a small and stable background current (0.35+/-0.013 microA) compared with the glucose response (ca. 10 microA at 10mM glucose) and suitable reproducibility from sample-to-sample (<3%, n=4).  相似文献   

5.
The interfacial electron transfer of glucose oxidase (GOx) on a poly(glutamic acid)-modified glassy carbon electrode (PGA/GCE) was investigated. The redox peaks measured for GOx and flavin adenine dinucleotide (FAD) are similar, and the anodic peak of GOx does not increase in the presence of glucose in a mediator-free solution. These indicate that the electroactivity of GOx is not the direct electron transfer (DET) between GOx and PGA/GCE and that the observed electroactivity of GOx is ascribed to free FAD that is released from GOx. However, efficient electron transfer occurred if an appropriate mediator was placed in solution, suggesting that GOx is active. The PGA/GCE-based biosensor showed wide linear response in the range of 0.5–5.5 mM with a low detection limit of 0.12 mM and high sensitivity and selectivity for measuring glucose.  相似文献   

6.
An amperometric-mediated glucose sensor has been developed by employing a silica sono-gel carbon composite electrode (SCC). The chosen mediators, ferrocene (Fc) and 1,2-diferrocenylethane (1), have been immobilized in the sono-gel composite matrix. The complex 1 has been employed for the first time as an electron transfer mediator for signal transduction from the active centre of the enzyme to the electrode conductive surface. After the optimisation of the construction procedure the best operative conditions for the analytical performance of the biosensor have been investigated in terms of pH, temperature and applied potential. Cyclic voltammetric and amperometric measurements have been used to study the response of both the glucose sensors, which exhibit a fast response and good reproducibility. The sensitivity to glucose is quite similar (6.7+/-0.1 microA/mM versus 5.3+/-0.1 microA/mM) when either Fc or 1 are used as mediators as are the detection limit ca. 1.0 mM (S/N=3) and the range of linear response (up to 13.0 mM). However, the dynamic range for glucose determination results wider when using 1 (up to 25.0 mM). The apparent Michaelis-Menten constants, calculated from the reciprocal plot under steady state conditions, are 27.7 and 31.6 mM for SCC-Fc/GOx and SCC-1/GOx electrodes, respectively, in agreement with a slightly higher electrocatalytic efficiency for the mediator 1.  相似文献   

7.
Microspheres coated with polyelectrolyte multilayers (PEM's) are being investigated for potential use as implantable biosensors-so-called "smart tattoos." In this work, the feasibility of this approach for glucose sensors was demonstrated by glucose oxidase encapsulated within calcium alginate microspheres, followed by entrapment of an oxygen-quenched ruthenium compound in the same microstructure. A novel feature of these microdevices is the formation of multilayer nanofilms on the surface of the microspheres, used to stabilize enzyme entrapment and control substrate diffusion. Confocal microscopy was used to confirm the stable encapsulation of sensor chemistry. The reversible response of sensors to step changes in glucose was observed, and preliminary experimental data were compared to theoretical predictions produced by a computational model. These findings demonstrate the promise of the described nanoengineering approach for production of functional implantable glucose sensor materials.  相似文献   

8.
Glucose sensing electrodes have been realized by immobilizing glucose oxidase (GOx) on unmodified edge plane of highly oriented pyrolytic graphite (epHOPG) and the native oxide of heavily doped silicon (SiO2/Si). Both kinds of electrode show direct interfacial electron transfer due to the redox process of the immobilized GOx. The measured formal potential of the redox process agrees with that of the native enzyme, suggesting that the immobilized GOx has retained its enzymatic activity. The electron transfer rates of the GOx immobilized electrode are 2s(-1) for GOx/epHOPG electrode and 7.9s(-1) for GOx/SiO2/Si electrode, which are greater than those for which GOx is immobilized on modified electrodes, probably due to the fact that the enzyme makes direct contact to electrode surface. The preservation of the enzymatic activity of the immobilized GOx has been confirmed by observing the response of the GOx/epHOPG and GOx/SiO2/Si electrodes to glucose with a detection limit of 0.050 mM. The response signals the catalyzed oxidation of glucose and, therefore, confirms that the immobilized GOx retained its enzymatic activity. The properties of the electrode as a glucose sensor are presented.  相似文献   

9.
In situ growth of gold nanoparticles (Au NPs) was performed in an alginate gel matrix co‐encapsulating Au NP seeds and glucose oxidase (GOx) for the development of a glucose‐sensing platform. We observed a simultaneous growth of Au NPs in the alginate matrix through the reduction of AuCl by H2O2 on Au NP seeds. The detection of the glucose level was carried out successfully via the coupling of Au NP enlargement with the oxidation of glucose catalyzed by the immobilized GOx. The enlargement of Au NPs in the alginate matrix exhibited only a red‐shift in absorbance maxima, while the generation of small Au NPs in a free solution caused a blue‐shift in higher glucose concentrations. This study shows that the co‐encapsulation of metal NPs and bioreceptor in a gel matrix may provide a simple route for the fabrication of an optical biosensor. Biotechnol. Bioeng. 2010;105: 210–214. © 2009 Wiley Periodicals, Inc.  相似文献   

10.
In this paper, a mediatorless amperometric glucose biosensor based on direct covalent immobilisation of monomolecular layer of glucose oxidase (GOx) on a semiconducting indium-tin oxide (ITO) is demonstrated. The abundance of surface hydroxyl functional group of ITO allows it to be used as a suitable platform for direct covalent immobilisation of the enzyme for sensor architecture. The anodic current corresponding to electrochemical oxidation of the enzymatic product, hydrogen peroxide, at a sputtered Pt electrode at 0.500 V (vs. SCE) was obtained as the sensor signal. It was found that the biosensor based on the direct immobilisation scheme shows a fast biosensor response, minimum interference from other common metabolic species and ease of biosensor miniaturisation. A linear range of 0-10 mM of glucose was demonstrated, which exhibits a high sensitivity as far as performance per immobilised GOx molecule is concerned. A detection limit as low as 0.05 mM and long-term stability were observed. Even more important, the biosensor design allows fabrication through a dry process. These characteristics make it possible to achieve mass production of biosensor compatible with the current electronic integrated circuit manufacturing technologies.  相似文献   

11.
For the first time glucose oxidase (GOx) was successfully co-deposited on nickel-oxide (NiO) nanoparticles at a glassy carbon electrode. In this paper we present a simple fabrication method of biosensor which can be easily operated without using any specific reagents. Cyclic voltammetry was used for electrodeposition of NiO nanoparticle and GOx immobilization. The direct electron transfer of immobilized GOx displays a pair of well defined and nearly reversible redox peaks with a formal potential (E(0')) of -0.420 V in pH 7 phosphate buffer solution and the response shows a surface controlled electrode process. The surface coverage and heterogeneous electron transfer rate constant (k(s)) of GOx immobilized on NiO film glassy carbon electrode are 9.45 x 10(-13)mol cm(-2) and 25.2+/-0.5s(-1), indicating the high enzyme loading ability of the NiO nanoparticles and great facilitation of the electron transfer between GOx and NiO nanoparticles. The biosensor shows excellent electrocatalytical response to the oxidation of glucose when ferrocenmethanol was used as an artificial redox mediator. Furthermore, the apparent Michaelis-Menten constant 2.7 mM, of GOx on the nickel oxide nanoparticles exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. In addition, this glucose biosensor shows fast amperometric response (3s) with the sensitivity of 446.2nA/mM, detection limit of 24 microM and wide concentration range of 30 microM to 5mM. This biosensor also exhibits good stability, reproducibility and long life time.  相似文献   

12.
Insulin is a peptide hormone that can regulate the metabolism of carbohydrates and lipids. This hormone is closely related to glucose‐uptake in cells and can control blood glucose levels. Dextran is a polysaccharide composed of glucose units. In this study, we discovered that dextran‐encapsulated gold nanoparticles (AuNPs@Dextran) and nanoclusters (AuNCs@Dextran) can be used to recognize insulin. The dissociation constant of insulin toward AuNPs@Dextran was estimated to be ~5.3 × 10?6 M. The binding site on insulin toward the dextran on the nanoprobes was explored as well. It was found that the sequence of numbers 1–22 on the insulin B chain can interact with the dextran encapsulated nanoprobes. Additionally, we also demonstrated that the dextran‐encapsulated nanoprobes could be used as concentration probes to selectively enrich trace amounts of insulin (~1 pM) from serum samples. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
A novel glucose biosensor was fabricated. The first layer of the biosensor was polythionine, which was formed by the electrochemical polymerisation of the thionine monomer on a glassy carbon electrode. The remaining layers were coated with chitosan-MWCNTs, GOx, and the chitosan-PTFE film in sequence. The MWCNTs embedded in FAD were like “conductive wires” connecting FAD with electrode, reduced the distance between them and were propitious to fast direct electron transfer. Combining with good electrical conductivity of PTH and MWCNTs, the current response was enlarged. The sensor was a parallel multi-component reaction system (PMRS) and excellent electrocatalytic performance for glucose could be obtained without a mediator. The glucose sensor had a working voltage of −0.42 V, an optimum working temperature of 25°C, an optimum working pH of 7.0, and the best percentage of polytetrafluoroethylene emulsion (PTFE) in the outer composite film was 2%. Under the optimised conditions, the biosensor displayed a high sensitivity of 2.80 µA mM−1 cm−2 and a low detection limit of 5 µM (S/N = 3), with a response time of less than 15 s and a linear range of 0.04 mM to 2.5 mM. Furthermore, the fabricated biosensor had a good selectivity, reproducibility, and long-term stability, indicating that the novel CTS+PTFE/GOx/MWCNTs/PTH composite is a promising material for immobilization of biomolecules and fabrication of third generation biosensors.  相似文献   

14.
Fluorescein and tetramethylrhodamine conjugates to protein or dextran were used to determine subcellular pH. The pH dependence of fluorescence of fluorescein isothiocyanate (FITC) conjugates could be described by a single proton dissociation (pK'a approximately 6.8). This allowed pH to be derived accurately from spectra using the simple Henderson-Hasslebach equation. FITC and TRITC conjugates were delivered to mouse macrophage lysosomes by pinocytosis. Lysosomal pH was then determined in several different ways. First, by direct matching of the subcellular fluorescence spectrum with calibration spectra obtained in free solution. Secondly, monensin was used to equilibrate internal and extracellular pH. Subcellular pH could then be determined by the relative increase in fluorescence of the FITC conjugate without loss of probe from the lysosomes. This allowed the calibration of pH dependence with the probe in situ. Finally, macrophages were permitted to pinocytose FITC and TRITC dextran conjugates simultaneously. pH could be determined from the ratio of emissions from the two dyes within the lysosomes. Each of these different methods gave a similar value for lysosomal pH (4.8 +/- 0.1).  相似文献   

15.
A highly sensitive electrochemical glucose sensor has been developed by the co-immobilization of glucose oxidase (GOx) and horseradish peroxidase (HRP) onto a gold electrode modified with biocompatible cyclic bisureas–gold nanoparticle conjugate (CBU–AuNP). A self-assembled monolayer of mercaptopropionic acid (MPA) and CBU–AuNP was formed on the gold electrode through a layer-by-layer assembly. This modified electrode was used for immobilization of the enzymes GOx and HRP. Both the HRP and GOx retained their catalytic activity for an extended time, as indicated by the low value of Michaelis–Menten constant. Analytical performance of the sensor was examined in terms of sensitivity, selectivity, reproducibility, lower detection limit, and stability. The developed sensor surface exhibited a limit of detection of 100 nM with a linear range of 100 nM to 1 mM. A high sensitivity of 217.5 μA mM−1 cm−2 at a low potential of −0.3 V was obtained in this sensor design. Various kinetic parameters were calculated. The sensor was examined for its practical clinical application by estimating glucose in human blood sample.  相似文献   

16.
A novel design and fabrication method of glucose sensors based on high aspect ratio carbon post-microarrays is reported in this paper. Apart from the fact that carbon has a wide electrochemical stability window, a major advantage of using carbon post-microarrays as working electrodes for an amperometric glucose sensor is the large reactive surface per unit footprint substrate area, improving sensitivity of the glucose sensor. The carbon post-microarrays were fabricated by carbon-microelectromechanical systems (C-MEMS) technology. Immobilization of enzyme onto the carbon post-electrodes was carried out through co-deposition of glucose oxidase (GOx) and electrochemically polymerized polypyrrole (PPy). Sensing performance of the glucose sensors with different post-heights and various post-densities was tested and compared. The carbon post-glucose sensors show a linear range from 0.5 mM to 20 mM and a response time of about 20 s, which are comparable to the simulation result. Sensitivity per unit footprint substrate area as large as 2.02 mA/(mM cm2) is achieved with the 140 μm high (aspect ratio around 5:1) carbon post-samples, which is two times the sensitivity per unit footprint substrate area of the flat carbon films. This result is consistent with the hypothesis that the number of reaction sites scales with the reactive surface area of the sensor. Numerical simulation based on enzymatic reaction and glucose diffusion kinetics gives the optimum geometric design rules for the carbon post-glucose sensor. Glucose sensors with even higher sensitivity can be achieved utilizing higher carbon post-microarrays when technology evolution will permit it.  相似文献   

17.
The encapsulation of biological enzymes within polyelectrolyte microcapsules is an important step toward microscale devices for processing and analytical applications, one which could be applied to the realization of minimally invasive sensing technology. In this work, the encapsulation and functional characterization of a bienzymatic coupled catalytic system within polyelectrolyte microcapsules is described. The two components, glucose oxidase (GOx) and horseradish peroxidase (HRP), were coprecipitated with calcium carbonate microspheres, followed by layer-by-layer assembly to form ultrathin polymer film coatings that act as capsule walls after removal of the sacrificial carbonate cores. Encapsulated concentrations of GOx and HRP were determined to be 19.7 +/- 1.0 and 29.4 +/- 3.6 mg/mL, respectively. An 85% decrease in the rate of glucose consumption relative to GOx and HRP in free solution was observed, which is attributed to substrate diffusion limitations. To further understand the temporal and spatial dynamics of the two-step reaction, a technique for monitoring microscale glucose consumption was developed using confocal imaging techniques. Time-based acquisition of capsule/Amplex Red suspensions was performed, from which it was observed that the high concentration of enzyme immobilized within the capsule walls resulted in a greater rate and quantity of glucose consumption at the capsule periphery when compared to glucose consumption within the capsule interior. These findings demonstrate the function of a bienzymatic catalytic system within the controlled environment of polyelectrolyte microspheres and a novel approach to analysis of the internal reactions using confocal imaging that will allow direct comparison with reaction-diffusion modeling and further explorations to optimize the distribution and activity of the encapsulated species.  相似文献   

18.
New polymeric microspheres containing azomethine ( 1a ‐ 1c and 2a ‐ 2c ) were synthesized by condensation to compare the enzymatic properties of the enzyme glucose oxidase (GOx) and to investigate antimutagenic and antimicrobial activities. The polymeric microspheres were characterized by elemental analysis, infrared spectra (FT‐IR), proton nuclear magnetic resonance spectra, thermal gravimetric analysis, and scanning electron microscopy analysis. The catalytic activity of the glucose oxidase enzyme follows Michaelis‐Menten kinetics. Influence of temperature, reusability, and storage capacity of the free and immobilized glucose oxidase enzyme were investigated. It is determined that immobilized enzymes exhibit good storage stability and reusability. After immobilization of GOx in polymeric supports, the thermal stability of the enzyme increased and the maximum reaction rate (Vmax) decreased. The activity of the immobilized enzymes was preserved even after 5 months. The antibacterial and antifungal activity of the polymeric microspheres were evaluated by well‐diffusion method against some selected pathogenic microorganisms. The antimutagenic properties of all compounds were also examined against sodium azide in human lymphocyte cells by micronuclei and sister chromatid exchange tests.  相似文献   

19.
Cerium oxide nanorods (CeO(2) NRs) were synthesized without templates through a low cost and simple non-isothermal precipitation method. The structure and morphology of CeO(2) NRs were characterized by X-ray diffraction and transmission electron microscopy. The CeO(2) NRs films, deposited on indium tin oxide (ITO)-coated glass substrates through electrophoretic deposition, were used for the immobilization of glucose oxidase (GOx). Field emission scanning electron microscopy, Fourier transform infrared spectroscopy, cyclic voltammetry, and electrochemical impedance spectroscopy were used to characterize the CeO(2) NRs/ITO and GOx/CeO(2) NRs/ITO electrodes. The GOx/CeO(2) NRs/ITO electrode exhibits a linear range for the detection of glucose from 2 to 26 mM (correlation coefficient: 0.99) at 1-2s response time. Biosensor sensitivity is 0.165 μA mM(-1) cm(-2) with 100 μM detection limit. The anti-interference ability of the biosensor was also examined. The mediator-less application of CeO(2) NRs for glucose sensing was demonstrated.  相似文献   

20.
The potential use of hydrazine sulfate was examined for the catalytic reduction of enzymatically generated H2O2 in a biosensor system. The performance of the hydrazine-based sensor was compared with an HRP-based glucose sensor as a model of a biosensor. Hydrazine and HRP were covalently immobilized onto a conducting polymer layer with glucose oxidase. The direct electron transfer reactions of the immobilized hydrazine and HRP onto the poly-5,2':5,2'-terthiophene-3'-carboxylic acid (poly-TTCA) layer were investigated by using cyclic voltammetric method and the electron transfer rate constants were determined. The glucose oxidase- and hydrazine-immobilized sensor efficiently reduced the enzymatically generated H2O2 at -0.15 V versus Ag/AgCl. The surface of this GOx/hydrazine/poly-TTCA-based glucose sensor was characterized by QCM, SEM, and ESCA. Glucose-sensing properties were studied using cyclic voltammetric and chronoamperometric techniques. Various experimental parameters were optimized according to the amount of hydrazine, pH, the temperature, and the applied potential. A linear calibration plot was obtained in the concentration range between 0.1 and 15.0 mM, and the detection limit was determined to be 40.0+/-7.0 microM. Interferences from other biological compounds were studied. The long-term stability of the GOx/hydrazine sensor was better than that of the one based on a GOx/HRP biosensor. The proposed glucose sensor was successfully applied to human whole blood and urine samples for the detection of glucose.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号