1.
Metoprolol is available for clinical use as a racemic mixture. The S‐(?)‐metoprolol enantiomer is the one expressing higher activity in the blockade of the β1‐adrenergic receptor. The α‐hydroxymetoprolol metabolite also has activity in the blockade of the β1‐adrenergic receptor. The present study describes the development and validation of a stereoselective method for sequential analysis of metoprolol and of α‐hydroxymetoprolol in plasma using high‐performance liquid chromatography with tandem mass spectrometry (LC‐MS/MS). 1‐ml aliquots of plasma were extracted with dichloromethane : diisopropyl ether (1:1, v/v). Metoprolol enantiomers and α‐hydroxymetoprolol isomers were separated on a Chiralpak AD column (Daicel Chemical Industries, New York, NY, USA) and quantitated by LC‐MS/MS. The limit of quantitation obtained was 0.2 ng of each metoprolol enantiomer/ml plasma and 0.1 ng/ml of each α‐hydroxymetoprolol isomer/ml plasma. The method was applied to the study of kinetic disposition of metoprolol in plasma samples collected up to 24 h after the administration of a single oral dose of 100‐mg metoprolol tartrate to a hypertensive parturient with a gestational age of 42 weeks. The clinical study showed that the metoprolol pharmakokinetics is enantioselective, with the observation of higher area under the curve (AUC)0?∞ values for S‐(?)‐metoprolol (AUCS‐(?)/AUCR‐(+) = 1.81) and the favoring of the formation of the new chiral center 1′R of α‐hydroxymetoprolol (AUC0?∞1′R/1′S = 2.78). Chirality, 25:1–7, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

2.
Chiral pesticide enantiomers often show different bioactivity and toxicity; however, this property is usually ignored when evaluating their environmental and public health risks. Hexaconazole is a chiral fungicide used on a variety of crops for the control of many fungal diseases. This use provides opportunities for the pollution of food and soil. In this study, a sensitive and convenient chiral liquid chromatography coupled with tandem mass spectrometry (LC‐MS/MS) method was developed and validated for measuring hexaconazole enantiomers in tomato, cucumber, and soil. Separation was by a reversed‐phase Chiralcel OD‐RH column, under isocratic conditions using a mixture of acetonitrile‐2 mM ammonium acetate in water (60/40, v/v) as the mobile phase at a flow rate of 0.4 mL/min. Parameters including the matrix effect, linearity, precision, accuracy and stability were undertaken. Then the proposed method was successfully applied to investigate the possible enantioselective degradation of rac‐hexaconazole in plants (tomato and cucumber) and soil under field conditions. The degradation of the two enantiomers of hexaconazole proved to be enantioselective and dependent on the media: The (+)‐enantiomer showed a faster degradation in plants, while the (?)‐enantiomer dissipated faster than the (+)‐form in field soil, resulting in relative enrichment of the opposite enantiomer. The results of this work demonstrate that both the environmental media and environmental conditions influenced the direction and rate of enantioselective degradation of hexaconazole. Chirality 25:160–169, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

3.
8‐Prenylnaringenin (8PN) is a naturally occurring bioactive chiral prenylflavonoid found most commonly in the female flowers of hops (Humulus lupulus L.). A stereospecific method of analysis for 8PN in biological fluids is necessary to study the pharmacokinetic disposition of each enantiomer. A novel and simple liquid chromatographic‐electrospray ionization‐mass spectrometry (LC‐ESI‐MS) method was developed for the simultaneous determination of R‐ and S‐8PN in rat serum and urine. Carbamazepine was used as the internal standard (IS). Enantiomeric resolution of 8PN was achieved on a Chiralpak® AD‐RH column with an isocratic mobile phase consisting of 2‐propanol and 10 mM ammonium formate (pH 8.5) (40:60, v/v) and a flow rate of 0.7 mL/min. Detection was achieved using negative selective ion monitoring (SIM) of 8PN at m/z 339.15 for both enantiomers and positive SIM m/z at 237.15 for the IS. The calibration curves for urine were linear over a range of 0.01–75 µg/mL and 0.05–75 µg/mL for serum with a limit of quantification of 0.05 µg/mL in serum and 0.01 µg/mL in urine. The method was successfully validated showing that it was sensitive, reproducible, and accurate for enantiospecific quantification of 8PN in biological matrices. The assay was successfully applied to a preliminary study of 8PN enantiomers in rat. Chirality 26:419–426, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

4.
Alpha‐cypermethrin (α‐CP), [(RS)‐a‐cyano‐3‐phenoxy benzyl (1RS)‐cis‐3‐(2, 2‐dichlorovinyl)‐2, 2‐dimethylcyclopropanecarboxylate], comprises a diastereoisomer pair of cypermethrin, which are (+)‐(1R‐cis‐αS)–CP (insecticidal) and (?)‐(1S‐cis‐αR)–CP (inactive). In this experiment, the stereoselective degradation of α‐CP was investigated in rat liver microsomes by high‐performance liquid chromatography (HPLC) with a cellulose‐tris‐ (3, 5‐dimethylphenylcarbamate)‐based chiral stationary phase. The results revealed that the degradation of (?)‐(1S‐cis‐αR)‐CP was much faster than (+)‐(1R‐cis‐αS)‐CP both in enantiomer monomers and rac‐α‐CP. As for the enzyme kinetic parameters, there were some variances between rac‐α‐CP and the enantiomer monomers. In rac‐α‐CP, the Vmax and CLint of (+)‐(1R‐cis‐αS)–CP (5105.22 ± 326.26 nM/min/mg protein and 189.64 mL/min/mg protein) were about one‐half of those of (?)‐(1S‐cis‐αR)–CP (9308.57 ± 772.24 nM/min/mg protein and 352.19 mL/min/mg protein), while the Km of the two α‐CP enantiomers were similar. However, in the enantiomer monomers of α‐CP, the Vmax and Km of (+)‐(1R‐cis‐αS) ‐CP were 2‐fold and 5‐fold of (?)‐(1S‐cis‐αR)‐CP, respectively, which showed a significant difference with rac‐α‐CP. The CLint of (+)‐(1R‐cis‐αS)–CP (140.97 mL/min/mg protein) was still about one‐half of (?)‐(1S‐cis‐αR)–CP (325.72 mL/min/mg protein) in enantiomer monomers. The interaction of enantiomers of α‐CP in rat liver microsomes was researched and the results showed that there were different interactions between the IC50 of (?)‐ to (+)‐(1R‐cis‐αS)‐CP and (+)‐ to (?)‐(1S‐cis‐αR)‐CP(IC50(?)/(+) / IC50(+)/(?) = 0.61). Chirality 28:58–64, 2016. © 2015 Wiley Periodicals, Inc.  相似文献   

5.
A sensitive and high‐throughput chiral liquid chromatography–tandem mass spectrometry method was developed and validated for the quantification of R‐pantoprazole and S‐pantoprazole in human plasma. Sample extraction was carried out by using ethyl acetate liquid–liquid extraction in 96‐well plate format. The separation of pantoprazole enantiomers was performed on a CHIRALCEL OJ‐RH column and an overlapping injection mode was used to achieve a run time of 5.0 min/sample. The mobile phase consisted of 1) 10 mM ammonium acetate in methanol: acetonitrile (1:1, v/v) and 2) 20 mM ammonium acetate in water. Isocratic elution was used with flow rate at 500 μL/min. The enantiomers were quantified on a triple‐quadrupole mass spectrometer under multiple reaction monitoring (MRM) mode with m/z 382.1/230.0 for pantoprazole and m/z 388.4/230.1 for pantoprazole‐d7. Linearity from 20.0 to 5000 ng/mL was established for each enantiomer (r2 > 0.99). Extraction recovery ranged from 91.7% to 96.4% for R‐pantoprazole and from 92.5% to 96.5% for S‐pantoprazole and the IS‐normalized matrix factor was 0.98 to 1.07 for R‐pantoprazole and S‐pantoprazole, respectively. The method was demonstrated with acceptable accuracy, precision, selectivity, and stability and the method was applied to support a pharmacokinetic study of a phase I clinical trial of racemic pantoprazole in healthy Chinese subjects. Chirality 28:569–575, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

6.
The chiral inversion and pharmacokinetics of two enantiomers of trantinterol, a new β2 agonist, were studied in rats dosed (+)‐ or (?)‐trantinterol separately. Plasma concentrations of (+)‐ and (?)‐trantinterol were measured by chiral stationary phase liquid chromatography tandem mass spectroscopy (LC‐MS/MS). The apparent inversion ratio was calculated as the ratio of AUC0‐t of (?)‐trantinterol or (+)‐trantinterol inverted from their antipodes to the sum of the AUC0‐t of (?)‐ and (+)‐trantinterol. Following single intravenous administration, both given enantiomers declined in similar plasma concentrations, suggesting that the two enantiomers have approximately the same disposition kinetics by the route of intravenous administration. However, after single oral administration, plasma concentrations of uninverted (?)‐trantinterol at many timepoints were significantly higher than those of uninverted (+)‐trantinterol, suggesting that the two enantiomers undergo apparently different absorption or metabolism after oral administration. Significant bidirectional chiral inversion occurred after intravenous and oral administration of (+)‐ or (?)‐trantinterol. After dosing with optically pure enantiomer, the concentration of the administered enantiomer predominated in vivo. The AUC0‐36 of (+)‐trantinterol after intravenous and oral dosing of (?)‐trantinterol were 16.6 ± 5.2 and 33.3 ± 16%, respectively of those of total [(+) + (?)] trantinterol. The AUC0‐36 of (?)‐trantinterol after intravenous and oral dosing of (+)‐trantinterol were 19.6 ± 8.8 and 37.9 ± 4.5%, respectively, of those of total [(?) + (+)] trantinterol. After intravenous administration of (+)‐ and (?)‐trantinterol the chiral inversion ratios of the two enantiomers were not significantly different and similar results were found for oral administration. The extent of chiral inversion after intravenous administration was apparently lower, indicating that the bidirectional chiral inversion was not only systemic but also presystemic. Chirality 25:934–938, 2013.© 2013 Wiley Periodicals, Inc.  相似文献   

7.
A stereoselective high‐performance liquid chromatographic (HPLC) method was developed and validated to determine S‐(?)‐ and R‐(+)‐propranolol in rat serum. Enantiomeric resolution was achieved on cellulose tris(3,5‐dimethylphenylcarbamate) immobilized onto spherical porous silica chiral stationary phase (CSP) known as Chiralpak IB. A simple analytical method was validated using a mobile phase consisted of n‐hexane‐ethanol‐triethylamine (95:5:0.4%, v/v/v) at a flow rate of 0.6 mL min‐1 and fluorescence detection set at excitation/emission wavelengths 290/375 nm. The calibration curves were linear over the range of 10–400 ng mL‐1 (R = 0.999) for each enantiomer with a detection limit of 3 ng mL‐1. The proposed method was validated in compliance with ICH guidelines in terms of linearity, accuracy, precision, limits of detection and quantitation, and other aspects of analytical validation. Actual quantification could be made for propranolol isomers in serum obtained from rats that had been intraperitoneally (i.p.) administered a single dose of the drug. The proposed method established in this study is simple and sensitive enough to be adopted in the fields of clinical and forensic toxicology. Molecular modeling studies including energy minimization and docking studies were first performed to illustrate the mechanism by which the active enantiomer binds to the β‐adrenergic receptor and second to find a suitable interpretation of how both enantiomers are interacting with cellulose tris(3,5‐dimethylphenylcarbamate) CSP during the process of resolution. The latter interaction was demonstrated by calculating the binding affinities and interaction distances between propranolol enantiomers and chiral selector. Chirality 26:194–199, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

8.
《Chirality》2017,29(10):603-609
d ‐ and l ‐Tryptophan (Trp) and d ‐ and l ‐kynurenine (KYN) were derivatized with a chiral reagent, (S )‐4‐(3‐isothiocyanatopyrrolidin‐1‐yl)‐7‐(N,N‐dimethylaminosulfonyl)‐2,1,3‐benzoxadiazole (DBD‐PyNCS), and were separated enantiomerically by high‐performance liquid chromatography (HPLC) equipped with a triazole‐bonded column (Cosmosil HILIC) using tandem mass spectrometric (MS/MS) detection. Effects of column temperature, salt (HCO2NH4) concentration, and pH of the mobile phase in the enantiomeric separation, followed by MS detection of (S )‐DBD‐PyNCS‐d ,l ‐Trp and ‐d ,l ‐KYN, were investigated. The mobile phase consisting of CH3CN/10 mM ammonium formate in H2O (pH 5.0) (90/10) with a column temperature of 50–60 °C gave satisfactory resolution (R s) and mass‐spectrometric detection. The enantiomeric separation of d ,l ‐Trp and d ,l ‐KYN produced R s values of 2.22 and 2.13, and separation factors (α) of 1.08 and 1.08, for the Trp and KYN enantiomers, respectively. The proposed LC–MS/MS method provided excellent detection sensitivity of both enantiomers of Trp and KYN (5.1–19 nM).  相似文献   

9.
Citalopram (CITA) is available as a racemic mixture and as a pure enantiomer. Its antidepressive action is related to the (+)-(S)-CITA and to the metabolite (+)-(S)-demethylcitalopram (DCITA). In the present investigation, a method for the analysis of CITA and DCITA enantiomers in human and rat plasma was developed and applied to the study of pharmacokinetics. Plasma samples (1 ml) were extracted at pH 9.0 with toluene:isoamyl alcohol (9:1, v/v). The CITA and DCITA enantiomers were analyzed by LC-MS/MS on a Chiralcel OD-R column. Recovery was higher than 70% for both enantiomers. The quantification limit was 0.1 ng/ml, and linearity was observed up to 500 ng/ml plasma for each CITA and DCITA enantiomer. The method was applied to the study of the kinetic disposition of CITA administered in a single oral dose of 20 mg to a healthy volunteer and in a single dose of 20 mg/kg (by gavage) to Wistar rats (n = 6 for each time). The results showed a higher proportion of the (-)-(R)-CITA in human and rat plasma, with S/R AUC ratios for CITA of 0.28 and 0.44, respectively. S/R AUC ratios of DCITA were 0.48 for rats and 1.04 for the healthy volunteer.  相似文献   

10.
Verapamil (VER) is commercialized as a racemic mixture of the (+)‐(R)‐VER and (?)‐(S)‐VER enantiomers. VER is biotransformed into norverapamil (NOR) and other metabolites through CYP‐dependent pathways. N‐hexane is a solvent that can alter the metabolism of CYP‐dependent drugs. The present study investigated the influence of n‐hexane (nose‐only inhalation exposure chamber at concentrations of 88, 176, and 352 mg/m3) on the kinetic disposition of the (+)‐(R)‐VER, (?)‐(S)‐VER, (R)‐NOR and (S)‐NOR in rats treated with a single dose of racemic VER (10 mg/kg). VER and NOR enantiomers in rat plasma was analyzed by LC‐MS/MS (m/z = 441.3 > 165.5 for the NOR and m/z 455.3 > 165.5 for the VER enantiomers) using a Chiralpak® AD column. Pharmacokinetic analysis was performed using a monocompartmental model. The pharmacokinetics of VER was enantioselective in control rats, with higher plasma proportions of the (?)‐(S)‐VER eutomer (AUC0?∞ = 250.8 vs. 120.4 ng/ml/h; P ≤ 0.05, Wilcoxon test). The (S)‐NOR metabolite was also found to accumulate in plasma of control animals, with an S/R AUC0?∞ ratio of 1.5. The pharmacokinetic parameters AUC0?∞, Cl/F, Vd/F, and t1/2 obtained for VER and NOR enantiomers were not altered by nose‐only exposure to n‐hexane at concentrations of 88, 176, or 352 mg/m3 (P > 0.05, Kruskal‐Wallis test). However, the verapamil kinetic disposition was not enantioselective for the animals exposed to n‐hexane at concentrations equal to or higher than the TLV‐TWA. This finding is relevant considering that the (?)‐(S)‐VER eutomer is 10–20 times more potent than R‐(+)‐VER in terms of its chronotropic effect on atrioventricular conduction in rats and humans. Chirality 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

11.
A chiral liquid chromatography/mass spectrometry (LC/MS) bioanalytical procedure has been developed for the analysis of the antimalaric agent Fenozan B07 in dog plasma. Normal-phase chromatography involving a phenylcarbamate derivative of cellulose coated on silica gel as the chiral stationary phase was used to resolve (-)-(S,S)-B07 from (+)-(R,R)-B07. The enantiomers were detected by a mass spectrometer equipped with an atmospheric pressure chemical ionization (APCI) interface operated in the negative ion mode. A mass spectrum, characterized by a base peak of m/z 285, was obtained for each enantiomer. The m/z 285 ion was very specific for the analysis of both enantiomers in the plasma. The selected ion monitoring analysis of the plasma samples was therefore performed at m/z 285 for quantitative purposes. The enantiomers were extracted from the plasma in a basic medium and purified by solid-phase extraction using a hydrophilic-lipophilic balanced sorbent. A lower limit of quantification of 2 ng/mL in plasma was achieved for both enantiomers. The quantitative procedure reported in this study was highly specific and sensitive, and was validated according to the FDA guidance on bioanalytical method validation.  相似文献   

12.
In this study, we report the synthesis, spectral characterization, antiepileptic activity and biotransformation of three new, chiral, N‐aminoalkyl derivatives of trans – 2 aminocyclohexan‐1‐ol: 1 (R enantiomer), 2 (S enantiomer) and 3 (racemate). Antiepileptic activity of the titled compounds was studied using MES and scMet. Moreover, in this study, the biotransformation of 1 , 2 and 3 in microbial model (Cunninghamella), liver microsomal assay as well as in silico studies (MetaSite) was evaluated. Studies have indicated that 1 , 2 and 3 have good antiepileptic activity in vivo, comparable to valproate. Biotransformation assays showed that the most probable metabolite (indicated in every tested assays) was M1 . The microbial model as well as in silico study showed no difference in biotransformation between tested enantiomers. However, in a rat liver microsomal study compound 1 and 2 (R and S enantiomer) had different main metabolite – M2 for 1 and M1 for 2 . MS/MS fragmentation allowed us to predict the structures of obtained metabolites, which were in agreement with 1°alcohol ( M1 ) and carboxylic acid ( M2 ). Our research has shown that microbial model, microsomal assay, and computational methods can be included as useful and reliable tools in early ADME‐Tox assays in the process of developing new drug candidates. Chirality 27:163–169, 2015. © 2014 Wiley Periodicals, Inc.  相似文献   

13.
Zhang Y  Shi K  Wen J  Fan G  Chai Y  Hong Z 《Chirality》2012,24(3):239-244
Tetrahydroberberine (THB), a racemic mixture of (+)‐ and (?)‐enantiomer, is a biologically active ingredient isolated from a traditional Chinese herb Rhizoma corydalis (yanhusuo). A chiral high performance liquid chromatography method has been developed for the determination of THB enantiomers in rat plasma. The enantioseparation was carried out on a Chiral®‐AD column using methanol:ethanol (80:20, v/v) as the mobile phase at the flow rate 0.4 ml/min. The ultraviolet detection was set at 230 nm. The calibration curves were linear over the range of 0.01–2.5 μg/ml for (+)‐THB and 0.01‐5.0 μg/ml for (?)‐THB, respectively. The lower limit of quantification was 0.01 μg/ml for both (+)‐THB and (?)‐THB. The stereoselective pharmacokinetics of THB enantiomers in rats was studied after oral and intravenous administration at a dose of 50 and 10 mg/kg racemic THB (rac‐THB). The mean plasma levels of (?)‐THB were higher at almost all time points than those of (+)‐THB. (?)‐THB also exhibited greater Cmax, and AUC0–∞, smaller CL and Vd, than its antipode. The (?)/(+)‐enantiomer ratio of AUC0–∞ after oral and intravenous administration were 2.17 and 1.43, respectively. These results indicated substantial stereoselectivity in the pharmacokinetics of THB enantiomers in rats. Chirality, 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

14.
Labetalol is clinically available as a mixture of two racemates (four stereoisomers). The stereoisomer (R,R) has as main activity the β1‐antagonism and the stereoisomer (S,R) is highly selective for the α1 adrenoceptor and is responsible for most of the α‐blocker activity. In the present investigation, a method for the analysis of labetalol stereoisomers in human plasma was developed and applied to pharmacokinetic studies. Plasma samples (0.5 ml) were extracted with methyl tert‐butyl ether at pH 9.5. The four labetalol stereoisomers were analyzed by LC‐MS/MS on a Chirobiotic® V column using a mobile phase consisting of methanol, acetic acid, and diethylamine, with a recovery of more than 90% for all four. The quantitation limit was 0.5 ng/ml and linearity was observed at 250 ng/ml plasma for each stereoisomer. Studies of precision and accuracy presented coefficients of variation and percentage inaccuracy of less than 15%, indicating that the method is precise and accurate. The method was applied to the study of the kinetic disposition of labetalol over a period of 12 h after oral administration of a single 100 mg dose to a hypertensive pregnant woman. The clinical study revealed stereoselectivity in the pharmacokinetics of labetalol, with a lower plasma proportion for the active stereoisomers (R,R)‐labetalol and (S,R)‐labetalol. The stereoselectivity observed after oral administration is due to the hepatic metabolism and the first pass effect, with an AUC(R,R)/AUC(S,S) ratio of 0.5. Chirality, 2009. © 2008 Wiley‐Liss, Inc.  相似文献   

15.
Warfarin is a commonly prescribed oral anti‐coagulant with narrow therapeutic index. It interferes with vitamin K cycle to achieve anti‐coagulating effects. Warfarin has two enantiomers, S(?) and R(+) and undergoes stereoselective metabolism, with the S(?) enantiomer being more effective. We reported that the intracellular protein profile in HepG2 cells incubated with S(?) and R(+) warfarin, using iTRAQ‐coupled 2‐D LC‐MS/MS. In samples incubated with S(?) and R(+) warfarin alone, the multi‐task protein Protein SET showed significant elevation in cells incubated with S(?) warfarin but not in those incubated with R(+) warfarin. In cells incubated with individual enantiomers of warfarin in the presence of vitamin K, protein disulfide isomerase A3 which is known as a glucose‐regulated protein, in cells incubated with S(?) warfarin was found to be down‐regulated compared to those incubated with R(+) warfarin. In addition, Protein DJ‐1 and 14‐3‐3 Proteinσ were down‐regulated in cells incubated with either S(?) or R(+) warfarin regardless of the presence of vitamin K. Our results indicated that Protein DJ‐1 may act as an enzyme for expression of essential enzymes in vitamin K cycle. Taken together, our findings provided molecular evidence on a comprehensive protein profile on warfarin–cell interaction, which may shed new lights on future improvement of warfarin therapy.  相似文献   

16.
Fluoxetine is used clinically as a racemic mixture of (+)‐(S) and (–)‐(R) enantiomers for the treatment of depression. CYP2D6 catalyzes the metabolism of both fluoxetine enantiomers. We aimed to evaluate whether exposure to gasoline results in CYP2D inhibition. Male Wistar rats exposed to filtered air (n = 36; control group) or to 600 ppm of gasoline (n = 36) in a nose‐only inhalation exposure chamber for 6 weeks (6 h/day, 5 days/week) received a single oral 10‐mg/kg dose of racemic fluoxetine. Fluoxetine enantiomers in plasma samples were analyzed by a validated analytical method using LC‐MS/MS. The separation of fluoxetine enantiomers was performed in a Chirobiotic V column using as the mobile phase a mixture of ethanol:ammonium acetate 15 mM. Higher plasma concentrations of the (+)‐(S)‐fluoxetine enantiomer were found in the control group (enantiomeric ratio AUC(+)‐(S)/(–)‐(R) = 1.68). In animals exposed to gasoline, we observed an increase in AUC0‐∞ for both enantiomers, with a sharper increase seen for the (–)‐(R)‐fluoxetine enantiomer (enantiomeric ratio AUC(+)‐(S)/(–)‐(R) = 1.07), resulting in a loss of enantioselectivity. Exposure to gasoline was found to result in the loss of enantioselectivity of fluoxetine, with the predominant reduction occurring in the clearance of the (–)‐(R)‐fluoxetine enantiomer (55% vs. 30%). Chirality 25:206–210, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

17.
Benalaxyl is widely applied as a fungicide during grape planting processing. In this experiment, the stereoselective behavior of benalaxyl was studied during the grape growth and wine‐making process. A simple method based on high‐performance liquid chromatography (HPLC) equipped with a chiral column and UV detector was established to separate and determine the enantiomers of benalaxyl. Stereoselective degradation of the two enantiomers of benalaxyl was found in grapes. The degradation of both enantiomers followed pseudofirst‐order kinetics, and the degradation rate of R‐(?)‐benalaxyl was faster than S‐(+)‐benalaxyl. The half‐life of R‐(?)‐benalaxyl was 27 h, while the half‐life of S‐(+)‐benalaxyl was 31 h. The enantiomer fraction value decreased from 0.50 to 0.34 and finally only S‐(+)‐benalaxyl could be detected. In the fermentation process, both enantiomers of benalaxyl were hardly degraded, and no configuration interconversion was observed. Meanwhile, both enantiomers of benalaxyl showed little influence on the growth of the yeast, consumption of carbon sources, or production of alcohol. The result of this study might provide more sufficient data for the evaluation of food safety and potential risk. Chirality 28:394–398, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

18.
A sensitive and enantioselective vancomycin chiral stationary phase high‐performance liquid chromatography–tandem mass spectrometry method was developed for the determination of trantinterol enantiomers in human plasma. Baseline resolution was achieved using the vancomycin chiral stationary phase known as Chirobiotic V with polar ionic mobile phase consisting of acetonitrile–methanol (60:40, v/v) containing 0.01% ammonia and 0.02% acetic acid at a flow rate of 1.0 mL/min. Waters Oasis HLB C18 solid phase extraction cartridges were used in the sample preparation of trantinterol samples from plasma. The detection was performed on a triple‐quadrupole tandem mass spectrometer by multiple reaction monitoring mode via electrospray ionization. The calibration curve was linear in a concentration range from 0.0606 to 30.3 ng/mL in plasma, with the lower limit of quantification of 0.0606 ng/mL. The intra‐ and interday precision (relative standard deviation) values were within 9.7% and the accuracy (relative error) was from ?6.6 to 7.2% at all quality control levels. The method was successfully applied to a study of stereoselective pharmacokinetics in human. Chirality 27:327–331, 2015.© 2015 Wiley Periodicals, Inc.  相似文献   

19.
A simple and rapid chiral high‐performance liquid chromatography (HPLC) method was developed and validated for bioanalysis of clopidogrel enantiomers on rat dried blood spots (DBS). Clopidogrel enantiomers were extracted from DBS using ethanol: methanol (80:20, v/v) and separated on a Chiralcel OJ‐H column containing cellulose tris (4‐methly benzoate) as a polysaccharide stationary phase using n‐hexane–ethanol‐diethylamine (70:30, 0.1 v/v) as a mobile phase at a flow rate of 1.0 mL/min. The detection was carried out at 220 nm using a photodiode array (PDA) detector while the elution order of the enantiomers was determined by a polarimeter connected to PDA in series. The effect of hematocrit on extraction of clopidogrel enantiomers from DBS was evaluated and no interference from endogenous substances was noticed. The overall accuracy of (R) and (S) enantiomers of clopidogrel from DBS were 91.6 and 89.2%, respectively. The calibration curves were linear over the concentration range of 1–500 µg/mL for both enantiomers. The results show that the method is specific, precise, and reproducible (intra‐ and interday precision relative standard deviations (RSDs) <10.0%). The stability of racemic clopidogrel was performed under all storage conditions and the results were found to be well within the acceptance limits. Chirality 26:102–107, 2014.© 2014 Wiley Periodicals, Inc.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号