首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
In recent years, increasing emphasis has been placed on quantitative characterization of drug metabolites for better insight into the correlation between metabolite exposure and toxicological observations or pharmacological efficacy. One common strategy for metabolite quantitation is to adopt the stable isotope labeled (STIL) parent drug as the internal standard in an isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay. In the current work, we demonstrate this strategy could have a potential pitfall resulting in quantitation bias if the internal standard is subject to ion suppression from the co-eluting parent drug in the incurred samples. Propranolol and its metabolite 4-hydroxypropranolol were used as model compounds to demonstrate this phenomenon and to systematically evaluate different approaches to mitigate the issue, including atmospheric pressure chemical ionization (APCI) mode of ionization, increased internal standard concentration, quantitation without internal standard, the use of a structural analog as internal standard, and dilution of the samples. Case studies of metabolite quantitation in nonclinical and clinical studies in drug development were also included to demonstrate the importance of using an appropriate bioanalytical strategy for metabolite quantitation in the real world. We present that bias of metabolite concentrations could pose a potential for poor estimation of safety risk. A strategy for quantitation of metabolites in support of drug safety assessment is proposed.  相似文献   

2.
An experimental platform has been developed for rapid sampling and quenching of chemostat cultivated Penicillium chrysogenum broth for metabolome analysis in highly dynamic experiments, aimed at the elucidation of the in vivo kinetic properties of metabolism. The sampling and quenching protocol available from Saccharomyces cerevisiae had to be modified for Penicillium chrysogenum mainly because of its filamentous character. Intracellular metabolites of glycolysis, TCA cycle, and adenine nucleotides were measured with isotope dilution mass spectrometry (IDMS) using a U-(13)C-labeled metabolite mix produced from yeast cells as internal standard. By addition of the U-(13)C internal standard mix prior to the metabolite extraction procedure, partial degradation of metabolites as well as non-linearity and drift of the LC-MS/MS could be successfully compensated for. It was found that there is a serious matrix effect on metabolite extraction between different organisms, which is however completely corrected for by the IDMS approach. Intracellular metabolites could be analyzed with standard deviations of around 5%. A comparison of the metabolite levels between Saccharomyces cerevisiae and Penicillium chrysogenum showed both significant similarities and large differences, which seem to be related to the presence of the penicillin pathway.  相似文献   

3.
A relatively simple gas chromatographic method has been developed for the quantitative determination of hydralazine simultaneously with its acetylated metabolite, 3-methyl-s-triazolo[3,4-α]phthalazine (MTP). The proteins were removed by means of sulfosalicylic acid and Sure-Sep®. On treatment with formic acid, hydralazine and its internal standard were converted into their formylated derivatives. These derivatives, MTP and its internal standard were extracted with toluene and determined by gas chromatography with a nitrogen-selective detector. The lower limits of detection for hydralazine and MTP were 0.13 and 0.27 μmol/l, respectively.  相似文献   

4.
The simultaneous determination of methadone (Mtd) enantiomers and its major metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), in human urine and serum by enantioselective HPLC using a new Cyclobond I-2000 RSP column is described. After alkaline extraction from urine or serum with estazolam as an internal standard, Mtd enantiomers and its metabolite (EDDP) are separated on the previous column with reversed-mobile phase and detected at 210 nm. Peak resolutions are about 2.0 for Mtd enantiomers. The relative standard deviations (R.S.D.) of Mtd and EDDP standards are between 0.5 and 4.5%. Most drugs of abuse are shown not to interfere with this technique. The method has been applied to study levels of each Mtd enantiomer and of its racemic metabolite in urine and serum of patients under maintenance treatment for opiate dependence. In urine, R-(−)-Mtd levels are always higher (about 2±0.5-fold_ than those of S-(+)-Mtd and in most cases, metabolite concentrations are greater than those of global Mtd enantiomers. However, the R-(−) enantiomer levels of residual drug in serum of some patients were lower than those of its antipode. This method is suitable for pharmacokinetic and toxicological studies of Mtd enantiomers and its major metabolite in biological fluids.  相似文献   

5.
A rapid and sensitive high-performance liquid chromatographic method was developed for determination of diclofenac and its major metabolite, 4'-hydroxydiclofenac, in serum from rats treated with diclofenac. The method is simple with a one-step extraction procedure, isocratic HPLC separation, and UV detection at 280 nm. Use of N-phenylanthranilic acid as the internal standard provided good accuracy without interference by endogenous compounds or 5-hydroxydiclofenac, another metabolite of interest. Limits of detection for diclofenac and 4'-hydroxydiclofenac were 0.0225 and 0.0112 microg/ml, respectively. Average extraction efficiencies of diclofenac, 4'-hydroxydiclofenac, and the internal standard were >/=76%. The method was applied to serum collected at 3h after rats were treated with an experimentally useful dosage range of 3, 10 and 50mg/kg diclofenac. Recovery (as a percentage of dose) for the 4'-hydroxy metabolite in serum was found to consistently average from 0.10 to 0.12% following each dosage, whereas recovery of diclofenac in serum declined from 0.45 to 0.37%. Thus, the method is suitable for measurement of a major diclofenac metabolite in experimental studies.  相似文献   

6.
A method for the determination of chlorimipramine and its metabolite demethylchlorimipramine in the plasma of depressed patients during treatment is described. The method involves extraction of the parent drug, its metabolite and the internal standard from plasma, back-extraction into an acidic aqueous phase and re-extraction into a small volume of organic phase. Separation and quantitation are carried out by ion-pair partition chromatography with UV detection. Accurate determination is possible down to levels of 30 and 60 nmole per liter of plasma for chlorimipramine and the metabolite, respectively, when 1 ml of plasma is used.The coefficient of variation is 7.3% or less at different levels for chlorimipramine and demethylchlorimipramine. Plasma levels of the parent drug and the metabolite measured by this liquid chromatographic method and by a gas chromatographic procedure with electron-capture detection were in good agreement (r = 0.98).The steady-state plasma level of the metabolite was always higher than that of the parent drug in the 34 depressed patients investigated. The mean ratio between the metabolite and the parent drug was 2.7 ± 1.1 (S.D.) Large inter-individual differences in the levels of the two compounds in patients receiving similar doses were found.  相似文献   

7.
This protocol provides a method for quantitating the intracellular concentrations of endogenous metabolites in cultured cells. The cells are grown in stable isotope-labeled media to near-complete isotopic enrichment and then extracted in organic solvent containing unlabeled internal standards in known concentrations. The ratio of endogenous metabolite to internal standard in the extract is determined using mass spectrometry (MS). The product of this ratio and the unlabeled standard amount equals the amount of endogenous metabolite present in the cells. The cellular concentration of the metabolite can then be calculated on the basis of intracellular volume of the extracted cells. The protocol is exemplified using Escherichia coli and primary human fibroblasts fed uniformly with (13)C-labeled carbon sources, with detection of (13)C-assimilation by liquid chromatography-tandem MS. It enables absolute quantitation of several dozen metabolites over approximately 1 week of work.  相似文献   

8.
A rapid, sensitive and selective method has been developed for the quantification of plasma concentrations of neuromuscular blocking drug, rocuronium, using gas chromatography with mass spectrometric detection. 3-Desacetylvecuronium served as the internal standard. The method involved iodide ion pair formation and a single-step liquid–liquid extraction with dicholoromethane. This method also permits simultaneous determination of its putative metabolite, 17-desacetylrocuronium, although the high detection limit for the metabolite limits the practical application of this method in pharmacokinetic study of the metabolite. The extraction efficiency was 75% for rocuronium and 50% for 17-desacetylrocuronium. The limit of quantification was 26 ng/ml for rocuronium and 870 ng/ml for its metabolite. The assay was used successfully in a patient undergoing liver transplantation and receiving rocuronium as a constant rate infusion and in a patient undergoing general elective surgery receiving the drug as an intravenous bolus. This assay is a time-saving alternative to published gas or liquid chromatographic methods for assaying rocuronium.  相似文献   

9.
A specific and sensitive method is described for the simultaneous determination of carbamazepineand carbamazepine-10,11-epoxide in biological specimens by combined gas chromatography-mass spectrometry. Cytenamide is used as the internal standard for quantitation. Kinetics of the distribution of the drug and its metabolite in plasma and in different areas of rat brain are reported. Determinations are possible at the nanogram level.  相似文献   

10.
Doxorubicin, a highly effective anticancer drug, produces severe side effect such as cardiotoxicity, which is mainly caused by its metabolite, doxorubicinol. While in vitro studies by measuring cellular concentration of doxorubicin have been reported, there have been no reports on measuring cellular concentration of the metabolites. In this report, we developed a sensitive and high-throughput method for measuring cellular concentrations of doxorubicin and its metabolites by ultra-high-performance liquid chromatography. The method achieved more than 96% recovery of doxorubicin and its metabolites from cell homogenates. Using simple separation conditions, doxorubicin and its three main metabolites, and the internal standard, were separated within 3 min. The method has a limit of quantification of 17.4 pg (32.0 fmol) injected doxorubicin. This high sensitivity enables the detection and intracellular quantification of doxorubicin and its metabolite, doxorubicinol, in cell homogenates, and its use will facilitate studies of the relationship between doxorubicin pharmacokinetics and therapeutic outcome.  相似文献   

11.
A high-performance liquid chromatographic method with electrochemical detection has been developed for the simultaneous determination of epirubicin, 13-S-dihydroepirubicin, doxorubicin and 13-S-dihydrodoxorubicin in human plasma. An aliquot of 200 μl plasma, spiked with internal standard, was extracted by solid-phase extraction using polymeric adsorbent columns. Chromatography was performed using a C18 reversed-phase column with a mobile phase consisting of water–acetonitrile (71:29, v/v) containing 0.05 M Na2HPO4 and 0.05% v/v triethylamine adjusted to pH 4.6 with citric acid. Linearity of the method was obtained in the concentration range of 1–500 ng/ml for all the analytes. Analytical recoveries of the analytes ranged from 89 to 93%. The assay can be used for the simultaneous determination of the four analytes, or for epirubicin and its metabolite or doxorubicin and its metabolite, using the other parent drug as an internal standard. The method was applied to analyze human plasma samples from patients treated with epirubicin using doxorubicin as an internal standard.  相似文献   

12.
A highly sensitive and selective high-performance liquid chromatographic assay has been developed for the separation and quantitation of tolmetin and its major metabolite in human biological fluids, viz. plasma, urine and synovial fluid. Analysis of plasma and synovial fluid required only 0.5 ml of the sample. The sample was washed with diethyl ether and extracted with diethyl ether—chloroform (2:1). The extracted compounds were injected onto a reversed-phase column (RP-2) and absorbance was measured at 313 nm. The standard curves in plasma were found to be linear for both tolmetin and the metabolite at concentrations from 0.04 to 10.0 μg/ml. Urine samples (0.5 ml) were diluted (1:1) with methanol containing the internal standard and were directly injected onto the reversed-phase (RP-2) column. Standard curves of tolmetin and metabolite in urine were linear in the range 5–300 μg/ml. Serum and synovial fluid concentrations of tolmetin and its metabolite in patients receiving multiple doses of tolmetin sodium were determined using the assay procedure.  相似文献   

13.
A methane chemical ionization quantitative assay for methylphenidate and its major metabolite, ritalinic acid, is described. Methylphenidate and the internal standard, ethylphenidate, were extracted from plasma samples and derivatized to prevent thermal decomposition in the gas chromatography. Ritalinic acid was esterified with diazomethane and extracted as methylphenidate. The intensity of the protonated molecular ion of the derivatized drug and internal standard was measured by selected ion monitoring. Calibration curves were prepared from drug standards dissolved in drug-free plasma, and the lower limit of the curves extended to 0.5 ng methylphenidate per ml plasma. The method was used to generate plasma decay curves for pediatric patients undergoing methylphenidate therapy.  相似文献   

14.
The enantiomers of chlorpheniramine and its monodesmethyl metabolite were determined separately in urine by using a coupled achiral–chiral chromatographic system. The two enantiomers of the studied compound and the internal standard were separated from the biological matrix on a cyanopropyl column and reinjected into a chiral amylose AD column where the two enantiomers were separated and quantified by UV detection. The method was validated for chlorpheniramine and for the metabolite within the range 0–1000 ng/ml. It was also applied in a pilot pharmacokinetic study to samples from a volunteer given 8 mg of racemic chlorpheniramine by mouth.  相似文献   

15.
Simultaneous separation and quantification of ezetimibe (EZM) and its phase-I metabolite i.e., ezetimibe ketone (EZM-K) and phase-II metabolite i.e., ezetimibe glucuronide (EZM-G) in various matrices was accomplished by gradient HPLC with UV detection. The assay procedure involved deproteinization of 500 microL of either incubation or bile sample containing analytes and internal standard (IS, theophylline) with 75 microL acetonitrile containing 25% perchloric acid. An aliquot of 100 microL supernatant was injected onto a C18 column. The chromatographic separation was achieved by gradient elution consisting of 0.05 M formic acid:acetonitrile:methanol:water at a flow rate of 1.0 mL/min. The detection of analyte peaks were achieved by monitoring the eluate using an UV detector set at 250 nm. Nominal retention times of IS, EZM-G, ezetimibe ketone glucuronide (EZM-KG), EZM and EZM-K were 9.39, 24.23, 27.82, 29.04 and 30.56 min, respectively. Average extraction efficiencies of EZM, EZM-G and IS was >75-80% and for EZM-K was >50% from all the matrices tested. Limit of quantitation (LOQ) for EZM, EZM-K and EZM-G was 0.02 microg/mL. Due to the lack of availability of reference standard of EZM-KG, the recovery and LOQ aspects for this metabolite were not assessed. Overall, the method is suitable for simultaneous measurement of EZM, and its phase-I and phase-II metabolite (EZM-G) in in vitro and in vivo studies.  相似文献   

16.
A gas chromatographic method for the determination of oxpentifylline and a metabolite, 1-(5′-hydroxyhexyl)-3,7-dimethylxanthine is described. Oxpentifylline, metabolite and internal standard are extracted from basified plasma into dichloromethane, then the metabolite and internal standard are converted to their O-trifluoroacetates. Analysis by gas—liquid chromatography using a nitrogen-selective detector allows quantification of oxpentifylline and 1-(5′-hydroxyhexyl)-3,7-dimethylxanthine down to levels of 3 ng/ml and 3–10 ng/ml, respectively. The assay had been applied to plasma samples from volunteers after both intravenous and oral administration of oxpentifylline. The need to separate plasma from erythrocytes immediately after venipuncture sampling to prevent further metabolism of oxpentifylline is emphasized.  相似文献   

17.
An assay for the N-oxide metabolite of a benzazepine drug by fast atom bombardment ionization with tandem mass spectrometric analysis on a triple quadrupole mass spectrometer has been developed and validated for urine and plasma samples. This methodology allows analysis of this metabolite directly in crude sample extracts, without the need for extensive chromatography or sample derivatization. Quantification was accomplished with the use of a stable isotope analog of the analyte as an internal standard, using the selected reaction monitoring mode of operation.  相似文献   

18.
A simple and selective determination method of 11-dehydrothromboxane B2 (11-dehydroTXB2), which is urinary metabolite of TXA2, has been developed employing liquid chromatography-tandem mass spectrometry (LC-MS-MS). 11-DehydroTXB2 and its deuterium-labeled analogue as an internal standard were extracted from urine by simple solid-phase extraction (SPE). These compounds were analyzed using LC-MS-MS in the selected reaction monitoring (SRM) mode, by monitoring the transitions from m/z 367 to m/z 161 for 11-dehydroTXB2 and from m/z 371 to m/z 165 for its internal standard. A good linear response over the range 50 pg-10 ng per tube was demonstrated. The values determined by LC-MS-MS were well validated and closely corresponded to the values determined by gas chromatography-mass spectrometry (GC-MS). The mean concentration of 11-dehydroTXB2 in urine of healthy adults was 635 +/- 427 pg/mg creatinine (mean +/- S.D., n = 13). This simple, accurate and selective determination method described in this study should greatly aid in evaluating the role of TXA2 in vivo.  相似文献   

19.
In this paper we develop an high-performance liquid chromatographic method with ultraviolet detection for the determination of verapamil and its primary metabolite norverapamil in biological samples. Both compounds, as well as the internal standard, imipramine, were extracted from alkalinised blood, with n-hexane–isobutyl alcohol, back-extracted into 0.01 M phosphoric acid and determined using a reversed-phase column and ultraviolet monitoring at 210 nm. The average coefficient of variation obtained over the concentration range of 1–1000 ng/ml is about 3%. The detection limit is below 5 ng/ml for both compounds, and extraction recoveries close to 80%. The method was applied to a pharmacokinetic study of the drug and its active metabolite and used to analyse blood samples from verapamil treated rabbits.  相似文献   

20.
An analytical method for the determination of benazepril and its active metabolite, benazeprilat, in human plasma by capillary gas chromatography-mass-selective detection, with their respective labelled internal standard, was developed and validated according to international regulatory requirements. After addition of the internal standards, the compounds were extracted from plasma by solid-phase extraction using automated 96-well plate technology. After elution, the compounds were converted into their methyl ester derivatives by means of a safe and stable diazomethane derivative. The methyl ester derivatives were determined by gas chromatography using a mass-selective detector at m/z 365 for benazepril and benazeprilat and m/z 370 for the internal standards. Intra- and inter-day accuracy and precision were found to be suitable over the range of concentrations between 2.50 and 1000 ng/mL.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号