首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
An HPLC method for determining a flavonoid naringin and its metabolite, naringenin, in human urine is presented for application to the pharmacokinetic study of naringin. Isocratic reversed-phase HPLC was employed for the quantitative analysis by using hesperidin for naringin or hesperetin for naringenin as internal standard and solid-phase extraction using a strong anion exchanger, Sep-Pak Accell QMA cartridge. The HPLC assay was carried out using an Inertsil ODS-2 column (250×4.6 mm I.D., 5 μm particle size). The mobile phases were acetonitrile–0.1 M ammonium acetate–acetic acid (18:81:1, v/v; pH 4.7) for naringin and acetonitrile–0.1 M ammonium acetate–triethylamine (25:75:0.05; v/v; pH 8.0) for naringenin. The flow-rate was 1.0 ml min−1. The analyses were performed by monitoring the wavelength of maximum UV absorbance at 282 nm for naringin and at 324 nm for naringenin. The lower limits of quantification were ca. 25 ng/ml for naringin and naringenin with R.S.D. less than 10%. The lower limits of detection (defined as a signal-to-noise ratio of about 3) were approximately 5 ng for naringin and 1 ng for naringenin. A preliminary experiment to investigate the urinary excretion of naringin, naringenin and naringenin glucuronides after oral administration of 500 mg of naringin to a healthy volunteer demonstrated that the present method was suitable for determining naringin and naringenin in human urine.  相似文献   

2.
A method for determining flavonoids in human plasma is presented for application to pharmacokinetic studies of two flavonoids, rhoifolin and daidzin. Isocratic reversed-phase high-performance liquid chromatography (HPLC) was used with genistin as an internal standard and solid-phase extraction using a Sep-Pak C18 cartridge. The mobile phases were acetonitrile—0.1 M ammonium acetate solution (20:80, v/v) for rhoifolin and methanol—0.1 M ammonium acetate solution (33:67, v/v) for daidzin. The detection limits on-column were 2 ng for rhoifolin and 0.5 ng for daidzin.  相似文献   

3.
A rapid and selective high-performance liquid chromatographic assay for determination of a new antimalarial drug (benflumetol, BFL) is described. After extraction with hexane-diethyl ether (70:30, v/v) from plasma, BFL was analysed using a C18 Partisil 10 ODS-3 reversed-phase stainless steel column and a mobile phase of acetonitrile-0.1 M ammonium acetate (90:10, v/v) adjusted to pH 4.9 with ultraviolet detection at 335 nm. The mean recovery of BFL over a concentration range of 50–400 ng/ml was 96.8±5.2%. The within-day and day-to-day coefficients of variation were 1.8–4.0 and 1.8–4.2%, respectively. The minimum detectable concentration in plasma for BFL was 5 ng/ml with a C.V. of less than 10%. This method was found to be suitable for clinical pharmacokinetic studies.  相似文献   

4.
We present new HPLC methods for the quantitation in human plasma of two investigative metallotexaphyrin agents, motexafin gadolinium (Gd-Tex) and motexafin lutetium (Lu-Tex). Each assay uses: the other texaphyrin analogue as an internal standard; protein precipitation with acetonitrile:methanol (50:50, v/v); an ODS reversed-phase column; an isocratic mobile phase of 100 mM ammonium acetate, pH 4.3:acetonitrile:methanol (59:21:20, v/v/v); and absorbance detection at 470 nm. The Gd-Tex assay has a lower limit of quantitation (LLOQ) of 0.01 μM and is linear between 0.01and 30 μM. The Lu-Tex assay has an LLOQ of 0.1 μM and is linear between 0.1 and 30 μM. The assays are suited for in vivo preclinical studies and clinical trials because they require minimal amounts of plasma, are sensitive, and involve a 30-min run time. These assays are important tools for evaluating the potential of Gd-Tex and Lu-Tex as a radiation enhancer and photosensitizer, respectively.  相似文献   

5.
A sensitive, quantitative reversed-phase high-performance liquid chromatographic method has been established for the simultaneous determination of butorphanol, a synthetic opioid, and its metabolites, hydroxybutorphanol and norbutorphanol, in human urine samples. The method involved extraction of butorphanol, hydroxybutorphanol, and norbutorphanol from urine (1.0 ml), buffered with 0.1 ml of 1.0 M ammonium acetate (pH 6.0), onto 1-ml Cyano Bond Elut columns. The eluent was evaporated under nitrogen and low heat, and reconstituted with the HPLC mobile phase, acetonitrile—methanol—water (20:10:70, v/v/v), containing 10 mM ammonium acetate and 10 mM TMAH (pH 5.0). The samples were chromatographed on a reversed-phase octyl 5-μm column. The analysis was accomplished by detection of the fluorescence of the three analytes, at excitation and emission wavelengths of 200 nm and 325 nm, respectively. The retention times for hydroxybutorphanol, norbutorphanol, the internal standard, and butorphanol were 5.5, 9.0, 13.0, and 23.4 min respectively. The validated quantitation range of the method was 1–100 ng/ml for butorphanol and hydroxybutorphanol, and 2–200 ng/ml for norbutorphanol in urine. The observed recoveries for butorphanol, hydroxybutorphanol, and norbutorphanol were 93%, 72%, and 50%, respectively. Standard curve correlation coefficients of 0.995 or greater were obtained during validation experiments and analysis of study samples. The method was applied on study samples from a clinical study of butorphanol, providing a pharmacokinetic profiling of butorphanol.  相似文献   

6.
A method for the quantification of mycophenolate mofetil (MMF, CellCept) in plasma using solid-phase extraction and HPLC is described here. A solution of internal standard is added to a 0.5-ml plasma aliquot. The resulting sample is treated with water and dilute HCl and applied to a C18 solid-phase extraction column. After a water wash, the MMF and internal standard are eluted with methanol-0.1 M citrate-phosphate buffer, pH 2.6 (80:20, v/v). A 20-μl aliquot of the eluate is injected onto a C18 column (5 μm particle size, 150 × 4.6 mm I.D.) and eluted at ambient temperature with acetonitrile-0.05 M citrate-phosphate buffer, pH 3.6, containing 0.02 M heptanesulfonic acid (41:59, v/v). Quantification is achieved by UV detection at 254 nm. The method is reproducible, accurate and specific for MMF. Using 0.5 ml of plasma for analysis, the quantification limit is 0.400 μg/ml and the range is 0.400–20 μg/ml. Based on the stability profile of MMF in plasma, it is recommended that blood samples collected following intravenous infusion be immediately stored on ice and that plasma be prepared rapidly, immediately stored frozen at −80°C and analyzed within four months of collection.  相似文献   

7.
A high-performance liquid chromatographic assay is described as a routine analytical method for the determination of fumagillin in rainbow trout muscle tissue. Muscle tissue samples (1 g) containing fumagillin were deproteinized with 8 ml of an acetonitrile-water mixture (2:6, v/v). The extracts were purified with a Bond Elut Octyl C8 cartridge column, washed with a water-methanol mixture (95:5, v/v; 4 ml) and fumagillin was eluted with acetonitrile (1 ml). Analytical separations were performed by reversed-phase HPLC with UV detection at 351 nm under gradient conditions. The mobile phase was acetonitrile-0.005 M tetrabutyl ammonium phosphate in water (pH 7.8). The assay is specific and reproducible within the fumagillin range of 20–1000 ng/g and recovery at 20 ng/g was 69.2%. Sample preparation involves the use of a robotic sample preparation system. Gravimetric validation of all operations enabled Good Laboratory Practices to be observed.  相似文献   

8.
A double column-switching high-performance liquid chromatographic (HPLC) method for the determination of concentrations for TAK-603 (T) and its metabolites, T-72258 (M-I) and T-72294 (M-III), in human serum was developed. The analytes were extracted with ethyl acetate from human serum samples treated with triethylamine and injected into the HPLC system. Separation of the analytes was performed on the HPLC system with double column-switching technique. The mobile phases A and B for the first column and the mobile phase C for the second column used were a mixture of methanol–10 mM aqueous ammonium acetate solution (1:1, v/v), methanol and a mixture of methanol–10 mM aqueous ammonium acetate solution (11:9, v/v), respectively. The eluate was monitored with a UV detector at a wavelength of 253 nm. The work-up procedure was reproducible and more than 90% of the analytes could be recovered from human serum. The lower limits of quantitation were all 1 ng/ml for the analytes when 0.5 ml of human serum was used. Standard curves were linear with a correlation coefficient (R) of more than 0.999 in the range of 1–500 ng/ml for T, M-I and M-III in human serum. The intra- and inter-day precision of the method for the various analytes were below 4.8%. The accuracy was good with the deviations between spiked and calculated concentrations of the analytes being within 11.0%. The method was successfully applied to analyze serum samples after an oral administration of T to healthy male volunteers.  相似文献   

9.
A sensitive and selective method for the determination of cefuroxime in bronchoalveolar lavage (BAL) fluid using high-performance liquid chromatography (HPLC) with UV detection at 280 nm after solid-phase extraction with C18 cartridges was developed. A Waters symmetry C18 column was used and the mobile phase was acetonitrile-0.05 M ammonium phosphate buffer (pH 3.2) (15:85, v/v). The method enabled the determination of cefuroxime at concentrations below 100 ng/ml, with a linear calibration curve at concentrations of 5–100 ng/ml for 400 μl of BAL. The intra- and inter-assay coefficient of variations for 10, 40 and 80 ng/ml were between 5.3 and 8.9%. Analytical recoveries were between 92.7 and 106.2%. The detection limit was 1 ng/ml at a signal-to-noise ratio of 3:1 using 400 μl of BAL. The method was successfully used for the analysis of BAL fluid from patients after oral administration of 500 mg cefuroxime axetil twice daily.  相似文献   

10.
Achiral and chiral HPLC methods were developed for clinafloxacin, a quinolone antimicrobial agent. For achiral assay, analytes were isolated from plasma by precipitating plasma proteins. Separation was achieved on a C18 column using an isocratic eluent of ion pairing solution–acetonitrile (80:20, v/v) at 1.0 ml/min with UV detection at 340 nm. The ion pairing solution was 0.05 M citric acid, 1.15 mM tetrabutylammonium hydroxide and 0.1% ammonium perchlorate. Inter-assay accuracy was within 4.9% with an inter-assay precision of 3.7% over a quantitation range of 0.025 to 10.0 μg/ml. For chiral assay, analytes were isolated from plasma by solid-phase extraction. Separation was achieved on a Crownpak CR(+) column using an isocratic eluent of water–methanol (88:12, v/v) containing 0.1 mM decylamine at 1.0 ml/min with UV detection at 340 nm. Perchloric acid was added to adjust pH to 2. Inter-assay accuracy was within 3.5% with a inter-assay precision of 5.4% over a quantitation range of 0.040 to 2.5 μg/ml.  相似文献   

11.
A high-performance liquid chromatographic method for the determination of the anthelmintic nitroxynil has been developed. The drug was extracted from cattle muscle tissue with 1% triethylamine in acetonitrile. The extract was evaporated to dryness and taken up in 0.1 M ammonium acetate—acetonitrile (50:50, v/v). The extract was then injected onto a polymeric anion-exchange precolumn. After clean-up with 0.1 M ammonium acetate—acetonitrile (50:50, v/v) for 5 min, the precolumn was eluted with 1% aqueous trifluoroacetic acid—acetonitrile (50:50, v/v) onto a PLRP-S polymer column and chromatographed with a mobile phase of 0.01 M phosphate pH 7—acetonitrile (80:20, v/v). Detection was by ultraviolet at 273 nm. Average recoveries at four levels from 0.005 to 1.000 mg kg−1 were > 88%. The limit of determination was 0.005 mg kg−1.  相似文献   

12.
An isocratic high-performance liquid chromatographic method has been developed and validated for the quantitative determination of paclitaxel (Taxol®), a novel antimitotic, anticancer agent, in human plasma. The analysis required 0.5 ml of plasma, and was accomplished by detection of the UV absorbance of paclitaxel at 227 nm following extraction and concentration. The method involved extraction of paclitaxel from plasma, buffered with 0.5 ml of 0.2 M ammonium acetate (pH 5.0), onto 1-ml cyano Bond Elut columns. The eluent was evaporated under nitrogen and low heat, and reconstituted with the mobile phase, acetonitrile-methanol-water (4:1:5, v/v/v) containing 0.01 M ammonium acetate (pH 5.0). The samples were chromatographed on a reversed-phase octyl 5 μm column. The retention time of paclitaxel was 10 min. The validated quantitation range of the method was 10–1000 ng/ml (0.012–1.17 μM) of paclitaxel in plasma. Standard curve correlation coefficients of 0.995 or greater were obtained during validation experiments and analysis of clinical study samples. The observed recovery for paclitaxel was 83%. Epitaxol, a biologically active stereoisomer, and baccatin III, a degradation product, were also chromatographically separated from taxol by this assay. The method was applied to samples from a clinical study of paclitaxel in cancer patients, providing a pharmacokinetic profiling of paclitaxel.  相似文献   

13.
A rapid and sensitive method using HPLC has been developed for the quantification of nicorandil (SG-75) in human plasma samples for routine bioequivalence studies. The sample preparation needs two liquid–liquid extractions, first with CH3Cl and HClO4 as denaturation reagent and second with addition of ethyl acetate and Na2CO3(aq). Detection wavelength was 256 nm. The obtained correlation coefficient for weighted linear curve in the range from 5.0 to 300 ng/ml was higher than 0.9950. The limit of quantitation (LOQ) was established at 5.0 ng/ml. The HPLC separation was accomplished on Nucleosil Phenyl (5 μm) stainless steel column within 7 min. The mixture of 0.01 M ammonium acetate buffer (pH 6.2) and acetonitrile 10:3 (v/v) was used as the mobile phase. The same separation method was examined on HPLC–MS system. Using this system, the LOQ was established at 1.0 ng/ml and the linearity was obtained in the range from 1.0 to 150 ng/ml.  相似文献   

14.
A sensitive reversed-phase high-performance liquid chromatographic method for the determination of atevirdine and its primary metabolite in human saliva or cerebrospinal fluid using solid-phase extraction is described. Samples mixed with internal standard and sodium phosphate buffer were applied to an activated C18 solid-phase extraction column. The reconstituted eluate was injected onto a Zorbax RX C8 column utilizing a mobile phase of 100 mM ammonium acetate (pH 4.0)–isopropyl alcohol–acetonitrile (55:20:25, v/v/v). Fluorescence detection was employed with excitation at 295 nm and emission at 456 nm. Quantitation was achieved using peak-height ratios. The detection response curve was linear from 2 to 850 nM for atevirdine in both human saliva and cerebrospinal fluid and from 2 to 250 nM for the metabolite in human saliva. The method was utilized to analyze cerebrospinal fluid and saliva samples from clinical studies.  相似文献   

15.
The objective of this research was to develop a rapid, sensitive and reliable method for the separation of phosphonodipeptide prodrugs and parent compounds to facilitate the evaluation of cell permeation using in vitro cell culture models. Separation was accomplished isocratically within 10.0 min using a C18 (150×4.6 mm I.D., 3 μm) reversed-phase column. The mobile phase consisted of 5 mM tetrahexyl ammonium (ion-pair reagent) in 0.02 M phosphate buffer pH 6.5-acetonitrile (48.5:51.5, v/v). The flow-rate was 1.1 ml/min with detection at 221 nm. The standard curves were linear (r2>0.999) over the concentration range 1–100 μM. The method was reliable and reproducible, with the limit of quantitation being 1 μM (25 ng on column).  相似文献   

16.
A sensitive, selective and simple HPLC method with fluorimetric detection is described for quantitating cocaine and its three metabolites in rat serum microsamples (50 μl). Chromatographic separation is achieved on a Hypersil BDS C18 column (100×2.1 mm, 5 μm) with an isocratic mobile phase consisting of methanol–acetonitrile–25.8 mM sodium acetate buffer, pH 2.6, containing 1.0·10−4 M tetrabutylammonium phosphate (14:10:76, v/v/v). The detection limit (0.5 ng/ml) for all the compounds, using direct fluorometric detection operated at excitation and emission wavelengths of 230 and 315 nm, respectively, was approximately five-times lower than that of using a UV detector operated at 235 nm. The effects of ratio of 2-propanol to chloroform in extraction solvents on the recovery and precision for cocaine and its metabolites were systematically examined. The method was used to study the pharmacokinetics of cocaine after administration of intravenous 2 mg/kg and oral 20 mg/kg doses.  相似文献   

17.
Extraction of DMP 450 from plasma was performed with C2 solid-phase extraction columns, using 0.1 M ammonium acetate in 90% methanol to elute DMP 450. The extraction recovery over the range of 10 to 10 000 ng/ml averaged 81.0, 96.2, 77.4, 95.2 and 68.0% from rat, dog, monkey, chimpanzee (25–10 000 ng/ml) and human plasma, respectively. HPLC analysis was carried out with a C18 column and a mobile phase of acetonitrile, methanol and 30 mM potassium phosphate (pH 3), the composition dependent on the type of plasma being analyzed, and monitored at a wavelength of 229 nm. Intra-day and inter-day coefficients of variation were less than 9.9 and 12.9%, respectively. Absolute differences were less than 11.5%.  相似文献   

18.
A new, simple and accurate high-performance liquid chromatography (HPLC) method for the determination of formycin A in plasma is presented. The samples were chromatographed on a LiChrosorb RP-18 column after purification using a Bakerbond SPE column. The mobile phase was methanol–0.067 M phosphate buffer, pH 4.20 (1:4, v/v) containing 0.005 M sodium hexanesulfonate. Azathioprine was applied as an internal standard. UV detection was carried out at 293 nm. The method was tested for linearity (over the range 0.1–9.0 μg/ml). The recovery was 91.89% (mean). The described method has been successfully applied to the quantitative determination of formycin A in plasma and should be useful for clinical and bioavailability investigations.  相似文献   

19.
A high-performance liquid chromatographic–electrochemical assay was developed and validated for the quantitation of BMS-181885 (I), an anti-migraine agent, in monkey plasma. The assay involved a solid-phase extraction of I and BMY-46317 (internal standard; I.S.) on a 1-ml cyano cartridge using the automatic solid-phase extraction cartridge (ASPEC) system. Immediately following the conditioning of the cyano column (3 ml of methanol and 2 ml of 1% glacial acetic acid), plasma (0.25 ml) was loaded on to the column. The column was then washed with a 3 ml of 0.1 M ammonium acetate buffer (pH 6). The final elution of the analytes was performed using 2 ml of methanol. The eluate was then evaporated to dryness (gentle stream of nitrogen at 40°C) and the residue was dissolved in the mobile phase and injected on to a YMC basic column (15 cm×4.6 mm; 5 μm particle size) at a flow-rate of 1 ml/min. A mixture of 0.1 M ammonium acetate at pH 6–acetonitrile–methanol (70:20:10, v/v) was used as the mobile phase. Standard curves, with a lower limit of quantitation of 2 ng/ml of I were linear (r2≥0.998; range: 2–50 ng/ml). Based on the analysis of the quality control (QC) samples, the assay was both accurate and precise. The stability of I was established following freeze–thaw cycles and storage at or below −20°C. The extraction recovery of I from monkey plasma was about 82%. The validated assay method was applied to determine the pharmacokinetics of I in monkeys following a single 1 mg/kg intravenous dose.  相似文献   

20.
A sensitive high-performance liquid chromatographic method for a routine assay of nadolol in serum is described. Serum samples spiked with atenolol (internal standard) were extracted with diethyl ether. After centrifugation, the organic layer was evaporated to dryness. The residue was redissolved in the mobile phase and injected onto an octadecyl silica column (150 mm × 4.6 mm I.D.). The mobile phase was 0.05 M ammonium acetate (pH 4.5)—acetonitrile (85:15, v/v). Fluorometric detection (excitation 230 nm, emission 300 nm) was used. The minimum detectable level of nadolol in serum was 1 ng/ml.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号