首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In diabetes research, mouse and rat models are used for in vivo experiments, and quantification of insulin in serum samples under different pathophysiological conditions and after treatment with compounds is essential. There are few commercial radioimmunoassay and enzyme-linked immunosorbent assay (ELISA) assay kits to determine the rat/mouse plasma levels of insulin. However, reliability in insulin measurements using the available biological assays is a great concern. The authors report a robust, extremely sensitive electrochemiluminescence (ECL) insulin assay using the Origen technology platform. The assay performance, as judged by the Z' value of 0.82+/-0.03 and the signal-to-background (S/B) ratio of 133, suggests that this is a robust and reliable assay. The intra-assay and interassay variation is less than 5%. The dynamic range of detection for insulin is 5 pg to 5 ng in the ECL assays. Recovery of insulin was about 100% when different volumes of serum were spiked with exogenous insulin. These results suggest that the ECL insulin assay is an extremely sensitive, robust, nonradioactive homogeneous assay and can be used successfully to determine the insulin levels in rodent serum samples.  相似文献   

2.
Primary cytomegalovirus (CMV) infection during pregnancy often results in congenital CMV infection with severe clinical complications. IgM antibodies are one of the indices of primary infection. The IgG avidity index (AI) is also known to remain low for 3 months after primary infection. Here, we evaluated and compared the performance of CMV IgM and IgG avidity assays. Because sensitivity and specificity reportedly differ between CMV IgM kits, CMV IgM detection was compared between the two commercially available ELISA kits that are most commonly used in Japan. Sera for CMV IgM were first screened using a traditional indirect ELISA kit. Selected samples were then tested for CMV IgM and CMV AI using a CMV IgM‐capture ELISA kit and a CMV IgG avidity assay, respectively. The rate of concordance between the IgM kits was 89% (42/47), indicating the absence of any significant difference. Most of the CMV IgM‐positive plasma samples showed high CMV IgG AI; however, 18 commercially available plasma samples with low CMV IgG AI were all CMV IgM‐positive. One plausible explanation for this discrepancy is that the duration of low IgG AI is shorter than that of IgM positivity. Alternatively, CMV IgM tests may generate pseudo‐positive readouts in cases of congenital infection. Nevertheless, our study confirms that CMV IgG AI can be a reliable indicator of CMV primary infection.  相似文献   

3.
Traditionally used methods of antibody affinity determination either by ELISA or by the surface plasmon resonance technique do not allow detection of the presence of low‐affinity antibodies in samples of high‐affinity antibodies. In this paper we demonstrate the possibility to reveal their presence and to determine the affinities of both categories of antibodies as well as the ratio of their concentrations. This is especially important since by using traditional methods for antibody affinity evaluation the admixture of low‐affinity antibodies in a sample diminishes the accuracy in determination of specific antibody affinity. In addition, the presence of an admixture of low‐affinity antibodies may be an important biological characteristic of the system under study; their revelation and the evaluation of their binding parameters may be valuable in many cases for obtaining a more complete characterization of the binding properties of the multiple antibodies generated in an immune response. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
J Neppert  S G?hring  W Schneider  P Wernet 《Blut》1986,53(2):115-117
Sera collected 13 years ago from 592 residents of the Republic of Liberia have been tested for antibodies to LAV polypeptides. 7 sera were positive by ELISA using two commercially available test kits whereas immunoblotting did not confirm antibodies specific for LAV.  相似文献   

5.
Staphylococcal food poisoning is one of the leading causes of bacterial food poisoning each year. Detection kits for staphylococcal enterotoxins are commercially available and the assays can require from one and a half to twenty-four hours to complete with detection limits ranging from 0.5 to 2 ng enterotoxin per gram of food. We have successfully demonstrated a microsphere-packed capillary (MPC) ELISA for the detection of staphylococcal enterotoxin A (SEA) and have compared it to two commercially available kits. The MPC assay detected a lower amount of SEA in ham, chicken, cheese, and bean sprouts than either of the two commercially available kits. In addition, the novel MPC assay was completed in less than ten minutes, as compared to three and twenty-four hours for the two commercially available kits. This research also demonstrated that the MPC ELISA can contain integrated positive and negative controls and has the potential to simultaneously detect and identify multiple enterotoxins.  相似文献   

6.
Phage display technology has been utilized for identification of specific binding molecules to an antigenic target thereby enabling the rapid generation and selection of high affinity, fully human antibodies directed towards disease target appropriate for antibody therapy. In the present study, single chain Fv antibody fragment (scFv) to hepatitis A virus (HAV) was selected from phage displayed antibody library constructed from peripheral blood lymphocytes (PBLs) of a vaccinated donor. The variable heavy (V(H)) and light chains (V(L)) were amplified using cDNA as template, assembled into scFv using splicing by overlap extension PCR (SOE PCR) and cloned into phagemid vector as a fusion for display of scFv on bacteriophage. The phage displaying antibody fragments were subjected to three rounds of panning with HAV antigen on solid phase. High affinity antibodies reactive to hepatitis A virus were identified by phage ELISA and cloned into a bacterial expression vector pET20b. The scFv was purified by immobilized metal affinity chromatography (IMAC) on a nickel-nitrilotriacetic acid (NTA) agarose column and characterized. The binding activity and specificity of the scFv was established by its non-reactivity towards other human viral antigens as determined by ELISA and immunoblot analysis. The scFv was further used in the development of an in-house IC-ELISA format in combination with a commercially available mouse monoclonal antibody for the quantification of hepatitis A virus antigen in human vaccine preparations. The adjusted r2 values obtained by subjecting the values obtained by quantification of the NIBSC standards using the commercial and the in-house ELISA kits by regression analysis were 0.99 and 0.95. 39 vaccine samples were subjected to quantification using both the kits. Regressional statistical analysis through the origin of the samples indicated International Unit (IU) values of 0.0416x and 0.0419x, respectively for the commercial and in-house kit respectively.  相似文献   

7.
To test the association of HLA-DR antigens with high-responder and low-responder status to either beef or pork insulin, insulin antibodies in diabetic sera were separated into those with average low and those with average high affinity and their insulin-binding capacities for each insulin determined. Significantly less binding of pork insulin by the high affinity antibodies occurred in the group of patients with DR3 antigens compared with those with DR4 antigens (p less than 0.01) and DR3/4 antigens (p less than 0.01). The difference in the binding capacity of beef insulin by the high affinity antibodies between the groups with DR3 and DR4 antigens was less pronounced but still significant. The high-responder status of DR3/4 antigens to pork insulin suggests that the gene or genes associated with HLA-DR4, and responsible for a high response to pork insulin, are dominant to genes associated with HLA-DR3 and a low response. If extended to human insulin and different HLA-DR and HLA-B antigen patterns, these finding should help in the therapeutic selection of the appropriate insulin and thus reduce the induction of an anti-insulin response in patients with diabetes.  相似文献   

8.
Antibody-binding fragments (Fab) are generated from whole antibodies by treatment with papain and can be separated from the Fc component using Protein-A affinity chromatography. Commercial kits are available, which facilitate the production and purification of Fab fragments; however, the manufacturer fails to report that this method is inefficient for antibodies with VH3 domains as a result of the intrinsic variable region affinity for Protein-A. A commercially available, modified Protein-A resin (MabSelect SuRe) has been engineered for greater stability. Here, we report that an additional consequence of the modified resin is the ability to purify VH3 family Fab fragments, which cannot be separated effectively from other components of the papain digest by traditional Protein-A resin. This improvement of a commonly used procedure is of significance, as increasingly, therapeutic antibodies are being derived from human origin, where VH3 is the most abundantly used variable region family.  相似文献   

9.
为探讨一株肝细胞癌特异性鼠源及其人源化单链抗体基因在大肠杆菌中的可溶性表达策略并比较二者对抗原的结构能力,在三种载体中分别以融合、分泌及胞内表达的方式进行了研究,表达产物均以包涵体形式存在;对复性后的单链抗体以细胞ELISA及竞争抑制流式细胞仪法进行检测,表明人源化单链抗体和鼠源单链抗体有相近的抗原结合能力。结论是:大肠杆菌中表达的基因工程单链抗体的可溶性可能主要由自身氨基酸一级序列决定;先前的设  相似文献   

10.
The enormous diversity of antibody specificities is generated by random rearrangement of immunoglobulin gene segments and is important for general protection against pathogens. Since random rearrangement harbors the risk of producing self‐destructive antibodies, it is assumed that autoreactive antibody specificities are removed during early B‐cell development leading to a peripheral compartment devoid of autoreactivity. Here, we immunized wild‐type mice with insulin as a common self‐antigen and monitored diabetes symptoms as a measure for autoimmune disease. Our results show that autoreactive anti‐insulin IgM and IgG antibodies associated with autoimmune diabetes can readily be generated in wild‐type animals. Surprisingly, recall immunizations induced increased titers of high‐affinity insulin‐specific IgM, which prevented autoimmune diabetes. We refer to this phenomenon as adaptive tolerance, in which high‐affinity memory IgM prevents autoimmune destruction by competing with self‐destructive antibodies. Together, this study suggests that B‐cell tolerance is not defined by the absolute elimination of autoreactive specificities, as harmful autoantibody responses can be generated in wild‐type animals. In contrast, inducible generation of autoantigen‐specific affinity‐matured IgM acts as a protective mechanism preventing self‐destruction.  相似文献   

11.
Staphylococcal enterotoxins (SEs) are the second most common causal agents of food poisoning throughout the world. Staphylococcal enterotoxin B (SEB) is one of the most potent and a listed biological warfare agent. Therefore, its quick, accurate and sensitive detection is of paramount importance. But availability of sensitive and specific antibodies against SEB is the major bottleneck in the development of an immunodetection system. Therefore, in the present study seb gene was cloned and expressed in a heterologous host resulting in a yield of 92 mg pure toxin per litre of culture broth after Ni–NTA affinity purification. Antibodies raised against the recombinant toxin did not cross react with related enterotoxins and organisms that can gain access in the food. Further, a sandwich ELISA was developed to detect SEB after extraction from artificially spiked food samples like milk, orange juice, skim milk and khoya. The sandwich ELISA was able to detect SEB in the range of 0.25 to 0.49 ng/ml or g of food. The detection system developed in the present study is at least as specific and sensitive as other commercially available kits which use monoclonal antibodies.  相似文献   

12.
Two types of commercially available ELISA kits for the immunoassay of cyanobacterial microcystins were evaluated for potential interference effects due to methanol, salinity, pH, plasticware and cyanobacterial extract. Of the treatments examined, methanol had the greatest effect, giving false positive microcystin concentrations with increasing methanol concentrations up to 30% (v/v) compared with the negative calibrators of each kit. False positive microcystin results were also produced with increasing salinity up to full strength seawater. Decreases in microcystin-LR equivalents were observed when assaying purified microcystin-LR at pH values between 6.25 and 10. Aqueous microcystin-LR solutions in plastic microcentrifuge tubes after pipetting with disposable plastic tips had lower toxin concentrations than expected when analysed by ELISA. Indicated microcystin concentrations in cyanobacterial extracts varied between kit types and the choice of blanks used. Although ELISAs can be useful tools for the screening of water and cyanobacterial blooms for microcystins and nodularins, users should be aware that commercial kits can be susceptible to interference by commonly encountered environmental and laboratory conditions and materials.  相似文献   

13.
We have demonstrated the formation of hybrid insulin/insulin-like growth factor-I(IGF-I) receptors in transfected rodent fibroblasts, which overexpress human receptors, by examining reactivity with species- and receptor-specific monoclonal antibodies. In NIH 3T3 and Rat 1 fibroblasts, endogenous IGF-I receptors were unreactive with anti-(human insulin receptor)monoclonal antibodies (47-9, 25-49, 83-14, 83-7, 18-44). However, in transfected cells expressing high levels of insulin receptors, 60-80% of high-affinity IGF-I receptors reacted with these antibodies, as assessed either by inhibition of ligand binding in intact cells or by precipitation of solubilized receptors. Conversely, endogenous insulin receptors in NIH 3T3 cells were unreactive with anti-(IGF-I receptor) antibodies alpha IR-3 and 16-13. However, approx. 50% of high-affinity insulin receptors reacted with these antibodies in cells expressing high levels of human IGF-I receptors. The hybrid receptors in transfected cells bound insulin or IGF-I with high affinity. However, responses to these ligands were asymmetrical, in that binding of IGF-I inhibited subsequent binding of insulin, but prior binding of insulin did not affect the affinity for IGF-I. The existence of hybrid receptors in normal tissues could have important implications for metabolic regulation by insulin and IGF-I.  相似文献   

14.
Monoclonal antibodies to subunits of bovine heart cytochrome c oxidase were prepared by immunizing mice with the isolated enzyme. The majority of antibody-producing cell lines were found to react with two different subunits of similar molecular mass, as shown by Western blotting and ELISA titrations with the HPLC-purified subunits. The affinities of the monoclonal antibodies to the subunits were determined by ELISA titrations with increasing concentrations of NH4SCN. Two monoclonal antibodies with a low affinity to subunit VIa had a high affinity to subunit VIc, whereas two other antibodies showed the same affinity to subunits VIIa and VIIb. The same affinity of monoclonal antibodies suggested an evolutionary relationship of subunits VIIa and VIIb, which was further supported by reactivity of these antibodies to subunits VIIa and VIIb of cytochrome c oxidase from different species and tissues. Also the evolutionary relationship between subunit VIa and VIc was shown by hybridization at low stringency of cDNAs for rat cytochrome c oxidase subunits VIc and VIa-h (heart-type), after amplification by the polymerase chain reaction, with a probe of VIa-l (liver-type).  相似文献   

15.
Unbiased discovery proteomics strategies have the potential to identify large numbers of novel biomarkers that can improve diagnostic and prognostic testing in a clinical setting and may help guide therapeutic interventions. When large numbers of candidate proteins are identified, it may be difficult to validate candidate biomarkers in a timely and efficient fashion from patient plasma samples that are event-driven, of finite volume and irreplaceable, such as at the onset of acute graft-versus-host disease (GVHD), a potentially life-threatening complication of allogeneic hematopoietic stem cell transplantation (HSCT).Here we describe the process of performing commercially available ELISAs for six validated GVHD proteins: IL-2Rα5, TNFR16, HGF7, IL-88, elafin2, and REG3α3 (also known as PAP1) in a sequential fashion to minimize freeze-thaw cycles, thawed plasma time and plasma usage. For this procedure we perform the ELISAs in sequential order as determined by sample dilution factor as established in our laboratory using manufacturer ELISA kits and protocols with minor adjustments to facilitate optimal sequential ELISA performance. The resulting plasma biomarker concentrations can then be compiled and analyzed for significant findings within a patient cohort. While these biomarkers are currently for research purposes only, their incorporation into clinical care is currently being investigated in clinical trials.This technique can be applied to perform ELISAs for multiple proteins/cytokines of interest on the same sample(s) provided the samples do not need to be mixed with other reagents. If ELISA kits do not come with pre-coated plates, 96-well half-well plates or 384-well plates can be used to further minimize use of samples/reagents.  相似文献   

16.
E Templ  H Templ 《Hormone research》1991,36(1-2):78-79
The quantitation of circulating angiotensin (ANG) II is not consistent among various commercially available kits. We measured plasma concentrations with three radioimmunoassay kits (Bühlmann Laboratories, Basel, Switzerland; Immuno Technology Service Production, The Netherlands, and Amersham, UK). The antibody specificity and their cross-reactions with ANG I decapeptide and with fragments of ANG II, were evaluated. The antibodies of the three kits cross-reacted with nearly all immunoreactive fragments of ANG II with intact carboxyl end. Cross-reaction with ANG I was detected with the antibody of the Immuno Technology Service kit only.  相似文献   

17.
抗吡虫啉单克隆抗体的制备及鉴定   总被引:1,自引:0,他引:1  
为制备灵敏度高,特异性强的抗吡虫啉单克隆抗体,建立经济、快速、准确的吡虫啉残留免疫学分析方法,采用分子模拟技术分析吡虫啉及其类似农药的电荷分布后,选择1-[6-(2-羧乙硫基-3-吡啶)甲基]-N-硝基-2-咪唑啉亚胺 (H1) 作为免疫半抗原,1-(6-氯-3-吡啶甲基)-3-羧丙基-N-硝基-2-咪唑啉亚胺 (H2) 作为包被半抗原,利用NHS酯法将H1和H2分别与牛血清蛋白 (BSA) 和卵清蛋白 (OVA) 偶联合成免疫原与包被原。免疫BALB/c小鼠后,采用常规杂交瘤技术共获得2株稳定分泌抗吡虫  相似文献   

18.
Oxidative stress, originating from reactive oxygen species (ROS), has been implicated in aging and various human diseases. The ROS generated can oxidize proteins producing protein carbonyl derivatives. The level of protein carbonyls in blood plasma has been used as a measure of overall oxidative stress in the body. Classically, protein carbonyls have been quantitated spectrophotometrically by directly reacting them with 2,4-dinitrophenylhydrazine (DNPH). However, the applicability of this method to biological samples is limited by its low inherent sensitivity. This limitation has been overcome by the development of sensitive enzyme-linked immunosorbent assay (ELISA) methods to measure protein carbonyls. As part of the Healthy Aging in Neighborhoods of Diversity across the Lifespan (HANDL) study, oxidative stress in humans was quantified by measuring blood plasma protein carbonyls using the two commercially available ELISA kits and the spectrophotometric DNPH assay. Surprisingly, two ELISA methods gave very different values for protein carbonyls, both of which were different from the value of the spectrophotometric method. We have developed a fluorescent semi-microplate format assay of protein carbonyls involving direct reaction of protein carbonyls with fluorescein thiosemicarbazide that correlates (R = 0.992) with the direct spectrophotometric method. It has a coefficient of variation of 4.99% and is at least 100 times more sensitive than the spectrophotometric method.  相似文献   

19.
金霉素单克隆抗体的制备及检测方法的建立   总被引:1,自引:0,他引:1  
采用羰基二咪唑法,将半抗原金霉素(AM)分别与牛血清白蛋白(BSA)和卵清蛋白(OVA)偶联制备金霉素免疫抗原AM-BSA和检测抗原AM-OVA,通过紫外光谱扫描检测偶联产物。采用细胞杂交瘤技术,制备抗金霉素单克隆抗体杂交瘤细胞株,建立了金霉素竞争ELISA检测方法,其灵敏度达到50ng/ml,且呈现良好的线性关系(r=0.9812),并且与其他抗生素无交叉反应。  相似文献   

20.
Endoplasmic reticulum (ER) stress contributes to beta cell death in type 2 diabetes (T2DM). ER stress is characterized by increased level of ER stress markers such as C/EBP homologous protein (CHOP). Activation of CHOP leads to its translocation into the nucleus, where it induces cell death. We previously reported nuclear CHOP in pancreatic sections from T2DM, but not T1DM, and in human islet amyloid polypeptide (IAPP) transgenic rodent pancreatic sections. These studies underscore the importance of studying nuclear CHOP. We have observed inconsistency in the detection of CHOP antibodies reported in the literature and also in our own experiments. To investigate the specificity of CHOP antibodies, we first induced ER stress by tunicamycin in rat insulinoma (INS) cells and prepared nuclear and cytoplasmic fractions. Then we examined CHOP expression by Western blotting and immunocytochemistry using seven commercially available CHOP antibodies in INS cells and human IAPP (h-IAPP) transgenic rodent pancreatic tissue. These studies show that three commercially available CHOP antibodies out of seven tested were non-specific. In conclusion, we give recommendations for CHOP antibody selection and methods to verify CHOP antibody specificity. Also, we propose that the authors report the catalog and lot numbers of the CHOP antibodies used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号