首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
This work aimed to characterise the whole human muscle input/output law during electrical stimulation with triangular varying frequency and amplitude trains through combined analysis of torque, mechanomyogram (MMG) and electromyogram (EMG).The tibialis anterior (TA) of ten subjects (age 23–35 years) was investigated during static contraction obtained through neuromuscular electrical stimulation. After potentiation, TA underwent two 15 s stimulation patterns: (a) frequency triangle (FT): 2 > 35 > 2 Hz at Vmax (amplitude providing full motor unit recruitment); (b) amplitude triangle (AT): Vmin > Vmax > Vmin (Vmin providing TA least mechanical response) at 35 Hz. 2 > 35 Hz or Vmin > Vmax as well as 35 > 2 Hz or Vmax > Vmin were defined as up-going ramp (UGR) and down-going ramp (DGR), respectively. TA torque, MMG and EMG were detected by a load cell, an optical laser distance sensor and a probe with two silver bar electrodes, respectively. For both FT and AT, only the two mechanical signals resulted always larger in DGR than in UGR, during AT extra-torque and extra-MMG were present even in the first 1/3 of the amplitude range where EMG data presented no significant differences between DGR and UGR.Our data suggest that extra-torque and extra-displacement are evident for both FT and AT, being mainly attributed to an intrinsic muscle property.  相似文献   

2.
Studies have demonstrated that the electromyographic (EMG) amplitude versus submaximal isometric force relationship is relatively linear. The purpose of this investigation was to determine the minimum number of contractions required to study this relationship. Eighteen men (mean age = 23 years) performed isometric contractions of the leg extensors at 10–90% of the maximum voluntary contraction (MVC) in 10% increments while surface EMG signals were detected from the vastus lateralis and vastus medialis. Linear regression was used to determine the coefficient of determination, slope coefficient, and y-intercept for each muscle and force combination with successively higher levels included in the model (i.e., 10–30%,  10–90% MVC). For the slope coefficients, there was a main effect for force combination (P < .001). The pairwise comparisons showed there was no difference from 10–60% through 10–90% MVC. For the y-intercepts, there were main effects for both muscle (vastus lateralis [4.3 μV RMS] > vastus medialis [−3.7 μV RMS]; P = .034) and force combination (P < .001), with similar values shown from 10–50% through 10–90% MVC. The linearity of the absolute EMG amplitude versus isometric force relationship for the vastus lateralis and vastus medialis suggests that investigators may exclude high force contractions from their testing protocol.  相似文献   

3.
The aims of the current study were to examine the stationarities of surface electromyographic (EMG) signals obtained from eight bilateral back and hip muscles during a modified Biering-Sørensen test, and to investigate whether short-time Fourier (STFT) and continuous wavelet transforms (CWT) provided similar information with regard to EMG spectral parameters in the analysis of localized muscle fatigue. Twenty healthy subjects participated in the study after giving their informed consent. Reverse arrangement tests showed that 91.6% of the EMG signal epochs demonstrated no significant trends (all p > 0.05), meaning 91.6% of the EMG signal epochs could be considered as stationary signals. Pearson correlation coefficients showed that STFT and CWT in general provide similar information with respect to the EMG spectral variables during isometric back extensions, and as a consequence STFT can still be used.  相似文献   

4.
Embryonic stem cell-derived cardiomyocytes (ESC-CMs) have applications in understanding cardiac disease pathophysiology, pharmacology, and toxicology. Comprehensive characterization of their basic physiological and pharmacological properties is critical in determining the suitability of ESC-CMs as models of cardiac activity. In this study we use video microscopy and quantitative PCR to investigate the responses of mouse ESC-CMs to adrenoceptor, muscarinic, angiotensin II (Ang II), and endothelin-1 (ET-1) receptor activation. Isoprenaline (10 nM–10 μM) increased beating rate and contraction amplitude in all beating bodies (BBs), whereas carbachol (up to 1 μM) and the If channel blocker ZD-7288 (10 μM) decreased contraction frequency. ET-1 (0.01–100 nM) reduced contraction amplitude in all BBs and increased contraction frequency in 50% of BBs; these effects were blocked by the ETA receptor antagonist BQ123 (250 nM). Ang II (0.01 nM–1 μM) increased both contraction amplitude (all BBs) and frequency (in 50% of BBs), effects blocked, respectively, by losartan (100 nM) and PD123,319 (200 nM). These results indicate the presence of functional ETA and both AT1 and AT2 receptors in murine ESC-CMs, but their expression and or activity appears to be evident only in a limited set of BBs.  相似文献   

5.
The purpose of this study was to use a wavelet-based signal processing technique to examine the influence of electrode placement over the innervation zone (IZ) on the shape of the electromyographic (EMG) frequency spectrum. Ten healthy males (mean ± SD age = 23.6 ± 3.0 years) performed isometric muscle actions of the dominant leg extensors at 10%, 40%, 70%, and 100% of the maximum voluntary contraction (MVC). Surface EMG signals were detected simultaneously from the vastus lateralis with two bipolar electrode arrangements. One of the electrode arrangements had its center point located directly over the IZ, while the other arrangement had its center point distal to the IZ (i.e., 20 mm away). All EMG signals were processed with a wavelet-based procedure. The results showed that for all isometric torque levels, the EMG signals from the distal electrode arrangement demonstrated greater total intensity values than those for the IZ arrangement for frequencies ranging from approximately 2 to 110 Hz. There were no consistent differences, however, between the IZ and distal electrode arrangements for total EMG intensity values above 110 Hz. Thus, these findings indicated that electrode placement over the IZ affected primarily the low-, rather than the high-frequency portion of the EMG frequency spectrum.  相似文献   

6.
This paper reviews data acquisition and signal processing issues relative to producing an amplitude estimate of surface EMG. The paper covers two principle areas. First, methods for reducing noise, artefact and interference in recorded EMG are described. Wherever possible noise should be reduced at the source via appropriate skin preparation, and the use of well designed active electrodes and signal recording instrumentation. Despite these efforts, some noise will always accompany the desired signal, thus signal processing techniques for noise reduction (e.g. band-pass filtering, adaptive noise cancellation filters and filters based on the wavelet transform) are discussed. Second, methods for estimating the amplitude of the EMG are reviewed. Most advanced, high-fidelity methods consist of six sequential stages: noise rejection/filtering, whitening, multiple-channel combination, amplitude demodulation, smoothing and relinearization. Theoretical and experimental research related to each of the above topics is reviewed and the current recommended practices are described.  相似文献   

7.
《IRBM》2008,29(4):231-238
This work focuses on the power line interference (PLI) rejection from surface EMG signal. It contains three parts: the algorithm, the experimental setting and the results. This study begins with describing the new technique, which consists in filtering respiratory surface electromyogram signals (EMG + PLI), then, becoming familiar with it. The proposed algorithm requires only one channel to both estimating the adaptive filter input reference noise and the EMG signal. The algorithm of PLI rejection has been organized into two steps. The first step insists to apply adaptive filter, especially the LMS one, in which the reference input is mathematically constructed using two different cosine functions; 50 Hz (the fundamental) function and 150 Hz (the first harmonic) function. Whereas, the second step applies the matching pursuit algorithm that uses the cosine packet dictionary to improve the result of PLI obtained at the first step. After trying statistical, as well as mathematical analysis, the complete investigation ensures that all details and steps make proof that our rigorous method is appropriate, we have also compared our method with the previous known techniques.  相似文献   

8.
The purpose of this study was to determine the effect of the ECG artifact on low-level trunk muscle activation amplitudes and assess the effectiveness of two methods used to remove the ECG. Simulations were performed and percent error in root mean square (RMS) amplitudes were calculated from uncontaminated and contaminated EMG signals at various ECG to EMG ratios. Two methods were used to remove the ECG: (1) filtering by adaptive sampling (FAS) and (2) Butterworth high pass filter at 30 Hz (BW-30 Hz HPF). The percent error was also calculated between the ECG removed and the uncontaminated EMG RMS amplitudes. Next, the BW-30 Hz HPF method was used to remove the ECG from 3-bilateral external oblique (EO) muscle sites collected from 30 healthy subjects performing a one handed lift and replace task. Two separate ANOVA models assessed the effects of ECG on the statistical interpretation of EO recruitment strategies. One model included EMG data that contained the ECG and the other model included EMG data after the ECG was removed. Large percent errors were observed when the ECG was not removed. These errors increased with larger ECG to EMG ratios. Both removal methods reduced the errors to below 10%, but the BW-30 Hz HPF method was more time efficient in removing the ECG artifact. Different statistical findings were observed among the muscle sites for the ECG contaminated model compared to the ECG removed model, which resulted in different conclusions concerning neuromuscular control.  相似文献   

9.
The purpose of this study was to examine the influence of interelectrode distance (IED) over the estimated innervation zone (IZ) for the vastus lateralis muscle and normalization on the torque-related patterns of responses for electromyographic (EMG) amplitude and mean power frequency (MPF) during concentric isokinetic, eccentric isokinetic, and isometric muscle actions of the leg extensors. Eight men performed submaximal to maximal concentric isokinetic, eccentric isokinetic, and isometric muscle actions of the dominant leg extensors. Surface EMG signals were recorded simultaneously with two bipolar electrode arrangements in single differential configuration (20 and 40 mm IEDs) placed over the estimated IZ for the vastus lateralis muscle and a third electrode arrangement in single differential configuration (20 mm IED) placed distal to the estimated IZ. The results indicated that there were only a few (six of 90 statistical comparisons) significant (p < 0.05) mean differences among the three electrode arrangements for absolute EMG amplitude. There were no mean differences among the three electrode arrangements for absolute or normalized EMG MPF values or normalized EMG amplitude for the three types of muscle actions. Thus, it may be possible to reduce the potential influence of the IZ on amplitude and spectral parameters of the EMG signal through normalization.  相似文献   

10.
11.
Sweat accumulation underneath surface EMG (sEMG) electrodes is a common problem in workplace studies which compromises electrode adherence to the skin as well as signal fidelity. In this study, the effect of sweat accumulation on signal amplitude and mean frequency (MF) was examined to determine if the sEMG signal becomes altered through the sweat layer and whether this effect can be avoided by interrupting the pool of sweat using a thin strip of medical adhesive between the electrode snaps. Nine males performed a maximum, isometric contraction of their right quadriceps as sEMG was collected. Skin conditions under the electrode were dry and wet in incremental layers of 0.02 mm of artificial sweat. The results demonstrated that sweat accumulation under sEMG electrodes dampens the amplitude of the EMG signal in a predictable way (r = .88 and .97 for double and single snap electrodes, respectively) with almost 2% and 3% deterioration for every 0.02 mm of sweat depending on the type of electrode used. The medical adhesive proved to be highly effective at preventing amplitude deterioration indicating that signal shunting can be prevented. MF was not influenced by sweat accumulation even under the extreme wet condition.  相似文献   

12.
The present study aimed to evaluate the effect of a resistance training program based on the electromyographic fatigue threshold (EMGFT, defined as the highest exercise intensity performed without EMG alterations), on the EMG amplitude (root mean square, RMS) and frequency (median frequency, MF) values for biceps brachii (BB), brachioradialis (BR), triceps brachii (TB) and multifidus (MT). Twenty healthy male subjects, (training group [TG], n = 10; control group [CG], n = 10), firstly performed isometric contractions, and after this, dynamic biceps curl at four different loads to determine the EMGFT. The TG training program used the BB EMGFT value (8 weeks, 2 sessions/week, 3 exhaustive bouts/session, 2 min rest between bouts). No significant differences were found for the isometric force after the training. The linear regression slopes of the RMS with time during the biceps curl presented significant decrease after training for the BB, BR and TB muscles. For the MT muscle, the slope and MF intercept values changed with training. The training program based on the EMGFT influenced EMG the amplitude more than EMG frequency, possibly related to the recruitment patterns of the muscles, although the trunk extensor muscles presented changes in the frequency parameter, showing adaptation to the training program.  相似文献   

13.
PurposeVibratory stimuli enhance muscle activity and may be used for rehabilitation and performance enhancement. Efficacy of vibration varies with the frequency of stimulation, but the optimal frequency is unclear. The purpose of this study was to examine the effects of 30 Hz and 60 Hz local muscle vibration (LMV) on quadriceps function.MethodsTwenty healthy volunteers (age = 20.4 ± 1.4 years, mass = 68.1 ± 11.0 kg, height = 170.1 ± 8.8 cm, males = 9) participated. Isometric knee extensor peak torque (PT), rate of torque development (RTD), and electromyography (EMG) of the quadriceps were assessed followed by one of the three LMV treatments (30 Hz, 60 Hz, control) applied under voluntary contraction, and again immediately, 5, 15, and 30 min post-treatment in three counterbalanced sessions. Dependent variables were analyzed using condition by time repeated-measures ANOVA.ResultsThe condition × time interaction was significant for EMG amplitude (p = 0.001), but not for PT (p = 0.324) or RTD (p = 0.425). The increase in EMG amplitude following 30 Hz LMV was significantly greater than 60 Hz LMV and control.ConclusionsThese findings suggest that 30 Hz LMV may elicit an improvement in quadriceps activation and could be used to treat quadriceps dysfunction resulting from knee pathologies.  相似文献   

14.
The aim of this study was to assess differences in physiological tremor amplitude of the hand between the dominant and non-dominant side of right-handed individuals. Mechanical loading of the hand and frequency analysis were used in an attempt to identify the physiological mechanisms involved in observed differences. Seventeen healthy right-handed adults participated in a single session where physiological tremor of the outstretched left and right hands was recorded under different loading conditions (0 g up to 5614 g). Physiological tremor amplitude was quantified through accelerometry and electromyographic (EMG) signals of wrist extensor and flexor muscles were also recorded. The main findings were: ~30% greater amplitude of fluctuations in acceleration for the non-dominant compared with the dominant hand, no difference in the frequency content of acceleration or demodulated EMG signals between dominant and non-dominant sides across all loads, and condition-dependent associations between the amplitude of fluctuations in acceleration and EMG amplitude and frequency content. These associations suggest a potential role of central modulation of neural activity to explain dominance-related differences in physiological tremor amplitude of the hand.  相似文献   

15.
PurposeTo compare a new normalization technique (wax pad, WAX) with the currently utilized cotton roll (COT) method in surface electromyography (sEMG) of the masticatory muscles.MethodssEMG of the masseter and anterior temporalis muscles of 23 subjects was recorded while performing two repetitions of 5 s maximum voluntary clenches (MVC) on COT and WAX. For each task, the mean value of sEMG amplitude and its coefficient of variation were calculated, and the differences between the two repetitions computed. The standard error of measurement (SEM) was calculated. For each subject and muscle, the COT-to-WAX maximum activity increment was computed. Participant preference between tasks was also recorded.ResultsWAX MVC tasks had larger maximum EMG amplitude than COT MVC tasks (P < 0.001), with COT-to-WAX maximum amplitude increments of 61% (temporalis) and 94% (masseter) (P = 0.006). WAX MVC had better test-retest repeatability than COT. For both MVC modalities, the mean amplitude (P > 0.391) and its coefficient of variation were unchanged (P > 0.180). The WAX task was the more comfortable for 18/23 subjects (P = 0.007).ConclusionWAX normalization ensures the same stability level of maximum EMG amplitude as COT normalization, but it is more repeatable, elicits larger maximum muscular contraction, and is felt to be more comfortable by subjects.  相似文献   

16.
The purpose of the present study was to examine the patterns of responses for torque, electromyographic (EMG) amplitude, EMG mean power frequency (MPF), mechanomyographic (MMG) amplitude, and MMG MPF across 30 repeated maximal isometric (ISO) and concentric (CON) muscle actions of the leg extensors. Twelve female subjects (21.1 ± 1.4 yrs; 63.3 ± 7.4 kg) performed ISO and CON fatigue protocols with EMG and MMG signals recorded from the vastus lateralis. The relationships for torque, EMG amplitude, EMG MPF, MMG amplitude, and MMG MPF versus repetition number were examined using polynomial regression. The results indicated there were decreases (p < 0.05) across the ISO muscle actions for torque (r2 = 0.95), EMG amplitude (R2 = 0.44), EMG MPF (r2 = 0.62), and MMG MPF (r2 = 0.48), but no change in MMG amplitude (r2 = 0.07). In addition, there were decreases across the CON muscle actions for torque (R2 = 0.97), EMG amplitude (R2 = 0.46), EMG MPF (R2 = 0.86), MMG amplitude (R2 = 0.44), and MMG MPF (R2 = 0.80). Thus, the current findings suggested that the mechanisms of fatigue and motor control strategies used to modulate torque production were similar between maximal ISO and CON muscle actions.  相似文献   

17.
Residual force enhancement (RFE) and force depression (FD) refer to an increased or decreased force following an active lengthening or shortening contraction, respectively, relative to the isometric force produced at the same activation level and muscle length. Our intent was to determine if EMG characteristics differed in the RFE or FD states compared with a purely isometric reference contraction for maximal and submaximal voluntary activation of the adductor pollicis muscle. Quantifying these alterations to EMG in history-dependent states allows for more accurate modeling approaches for movement control in the future. For maximal voluntary contractions (MVC), RFE was 6–15% (P < 0.001) and FD was 12–19% (P < 0.001). The median frequency of the EMG was not different between RFE, FD and isometric reference contractions for the 100% and 40% MVC intensities (P > 0.05). However, root mean square EMG (EMGRMS) amplitude for the submaximal contractions was higher in the FD and lower in the RFE state, respectively (P < 0.05). For maximal contractions, EMGRMS was lower for the FD state but was the same for the RFE state compared to the isometric reference contractions (P > 0.05). Neuromuscular efficiency (NME; force/EMG) was lower in the force depressed state and higher in the force enhanced state (P < 0.05) compared to the isometric reference contractions. EMG spectral properties were not altered between the force-enhanced and depressed states relative to the isometric reference contractions, while EMG amplitude measures were.  相似文献   

18.
IntroductionThe purpose of this study was to examine possible correlations between skinfold thicknesses and the a terms from the log-transformed electromyographic (EMGRMS) and mechanomyographic amplitude (MMGRMS)-force relationships, EMG M-Waves, and MMG gross lateral movements (GLM).MethodsForty healthy subjects performed a 6-s isometric ramp contraction from 5% to 85% of their maximal voluntary contraction with EMG and MMG sensors placed on the vastus lateralis (VL) and rectus femoris (RF). A single electrical stimulus was applied to the femoral nerve to record the EMG M-waves and MMG GLMs. Skinfold thickness was assessed at the site of each electrode. Pearson’s product correlation coefficients were calculated comparing skinfold thicknesses with the a terms from the log-transformed EMGRMS-and MMGRMS-force relationships, EMG M-waves, and MMG GLMs.ResultsThere were no significant cor1relations (p > 0.05) between the a terms and skinfold thicknesses for the RF and VL from the EMGRMS and MMGRMS-force relationships. However, there were significant correlations (p < 0.05) between skinfold thicknesses and the EMG M-waves and MMG GLMs for the RF (r = −0.521, −0.376) and VL (r = −0.479, −0.484).DiscussionRelationships were only present between skinfold thickness and the amplitudes of the EMG and MMG signals during the non-voluntary muscle actions.  相似文献   

19.
Oh ES  Seo YK  Yoon HH  Cho H  Yoon MY  Park JK 《Life sciences》2011,88(3-4):169-177
AimsAlthough low and high intensity sub-sonic vibrations (SSV) have been shown to facilitate wound healing, very few studies have investigated the effects of SSV on 3T3-L1 preadipocytes. Therefore, the present study was undertaken to investigate the influence of SSV on the proliferation and maturation of 3T3-L1 preadipocytes.Main methodsTo evaluate the effect of SSV on 3T3-L1 cell proliferation, the cells were maintained in an apparatus that administered SSV (0.5 V) for 3 days at a frequency of 10, 20, 30, or 40 Hz. In addition, to study the effect of SSV on 3T3-L1 cell maturation, the cells were stimulated with SSV for 6 days at a frequency of 10, 20, 30, or 45 Hz.Key findingsSub-sonic vibrations inhibited the proliferation of 3T3-L1 preadipocytes at frequencies of 20 and 30 Hz. Triglyceride levels in cells subjected to SSV at frequencies ranging from 10 to 30 Hz increased compared with those measured in control cells. The expression of adipogenic genes, such as PPAR-γ and C/EBP-α, markedly increased in response to SSV at 20 Hz and 30 Hz during maturation.SignificanceThese results suggest that SSV affected adipogenic gene expression at 20 and 30 Hz.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号