首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 162 毫秒
1.
2.
It is not known if murine cytomegalovirus (MCMV) establishes a state of molecular latency independent of low-level persistent infection. The presence of low levels of infectious MCMV distinguishes persistence from molecular latency. Thus, the distinction between persistence and latency has depended on the sensitivity of plaque assays for detecting low levels of infectious virus in tissue of previously infected mice. To determine whether MCMV establishes molecular latency or remains persistent, we developed two assays for detecting low levels of MCMV in tissue. Using prolonged in vitro culture of virus with either mouse embryonic fibroblasts or the murine 3T12 fibroblast cell line, we reproducibly detected a single PFU of MCMV. Inclusion of undiluted sonicated tissue in this assay decreased sensitivity by up to 100-fold. However, sensitivity was improved to 1 PFU of MCMV when sonicated tissue was appropriately diluted. Severe combined immunodeficient (SCID) mice were also used to detect MCMV in sonicated tissue. Infection of SCID mice with a single PFU of MCMV killed two of eight SCID mice, and the 50% lethal dose of MCMV in SCID mice was 2 to 3 PFU. Applying these two methods, we detected infectious virus in 0 of 34 spleens, 1 of 34 kidneys, and 0 of 37 salivary glands from latently infected mice. Spleens and kidneys assessed for persistent virus contained MCMV DNA by PCR and reactivated after 10 to 50 days in explant cultures. Latently infected kidney cells reactivated after adoptive transfer to SCID mice. Quantitation of the MCMV genome by PCR showed that latently infected spleens without detectable infectious MCMV contained about 3,000,000 copies of the MCMV genome. These results demonstrate that MCMV latency in spleen and kidney exists in the absence of low-level persistent infection. Use of assays with defined sensitivity for detection of MCMV in tissue provides a basis for evaluation of cytomegalovirus gene expression in the spleen and kidney during molecular latency.  相似文献   

3.
A colorimetric nucleic acid sequence-based amplification-enzyme-linked immunosorbent assay (NASBA-ELISA) was developed for rapid detection and identification of human rotavirus. Oligonucleotide primers targeting gene 9 encoding a serotype-specific antigen VP7 were selected and used for the amplification of viral RNA by the isothermal NASBA process, resulting in the accumulation of biotinylated RNA amplicons. Amplicons were hybridized with a specific amino-linked oligonucleotide probe covalently immobilized on microtiter plates. The DNA-RNA hybrids were colorimetrically detected by the addition of streptavidin-peroxidase conjugate and tetramethylbenzidine substrate. Using the NASBA-ELISA system, as little as 0.2 PFU (4 x 10(1) PFU ml(-1)) and 15 PFU (3 x 10(3) PFU ml(-1)) of rotavirus were detected within 6 h in spiked MQ water and sewage treatment effluent respectively. No interference was encountered in the amplification and detection of rotavirus in the presence of non-target RNA or DNA. Moreover, the presence of non-target bacteria and virus does not generate any non-specific signal, confirming the specificity of the developed NASBA-ELISA system and its effectiveness in specifically detecting rotavirus. The NASBA-ELISA system offers several advantages in terms of sensitivity, rapidity and simplicity. This technique should be readily adaptable for detection of other RNA viruses in both foods and clinical samples.  相似文献   

4.
Rotaviruses infect mature, differentiated enterocytes of the small intestine and, by an unknown mechanism, escape the gastrointestinal tract and cause viremia. The neonatal rat model of rotavirus infection was used to determine the kinetics of viremia, spread, and pathology of rotavirus in extraintestinal organs. Five-day-old rat pups were inoculated intragastrically with an animal (RRV) or human (HAL1166) rotavirus or phosphate-buffered saline. Blood was collected from a subset of rat pups, and following perfusion to remove residual blood, organs were removed and homogenized to analyze rotavirus-specific antigen by enzyme-linked immunosorbent assay and infectious rotavirus by fluorescent focus assay or fixed in formalin for histology and immunohistochemistry. Viremia was detected following rotavirus infection with RRV and HAL1166. The RRV 50% antigenemia dose was 1.8 x 10(3) PFU, and the 50% diarrhea dose was 7.7 x 10(5) PFU, indicating that infection and viremia occurred in the absence of diarrhea and that detecting rotavirus antigen in the blood was a more sensitive measure of infection than diarrhea. Rotavirus antigens and infectious virus were detected in multiple organs (stomach, intestines, liver, lungs, spleen, kidneys, pancreas, thymus, and bladder). Histopathological changes due to rotavirus infection included acute inflammation of the portal tract and bile duct, microsteatosis, necrosis, and inflammatory cell infiltrates in the parenchymas of the liver and lungs. Colocalization of structural and nonstructural proteins with histopathology in the liver and lungs indicated that the histological changes observed were due to rotavirus infection and replication. Replicating rotavirus was also detected in macrophages in the lungs and blood vessels, indicating a possible mechanism of rotavirus dissemination. Extraintestinal infectious rotavirus, but not diarrhea, was observed in the presence of passively or actively acquired rotavirus-specific antibody. These findings alter the previously accepted concept of rotavirus pathogenesis to include not only gastroenteritis but also viremia, and they indicate that rotavirus could cause a broad array of systemic diseases in a number of different organs.  相似文献   

5.
A modified polyethylene glycol precipitation method for concentration of virus followed by a new method to recover nucleic acid was used to detect hepatitis A virus (HAV) and rotavirus (SA11) in shellfish (oysters and hard-shell clams) by hybridization tests. Infectious virus, seeded into relatively large quantities of shellfish, was recovered consistently, with greater than 90% efficiency as measured by either in situ hybridization (HAV) or plaque assay (rotavirus SA11). Viral nucleic acid for dot blot hybridization assays was extracted and purified from virus-containing polyethylene glycol concentrates. Separation of shellfish polysaccharides from nucleic acid was necessary before viral RNA could be detected by dot blot hybridization. Removal of shellfish polysaccharides was accomplished by using the cationic detergent cetyltrimethylammonium bromide (CTAB). Use of CTAB reduced background interference with hybridization signals, which resulted in increased hybridization test sensitivity. After polysaccharide removal, dot blot hybridization assays could detect approximately 10(6) physical particles (corresponding to approximately 10(3) infectious particles) of HAV and 10(4) PFU of SA11 rotavirus present in 20-g samples of oyster and clam meats. These studies show continuing promise for the development of uniform methods to directly detect human viral pathogens in different types of shellfish. However, practical applications of such methods to detect noncultivatable human viral pathogens of public health interest will require additional improvements in test sensitivity.  相似文献   

6.
A modified polyethylene glycol precipitation method for concentration of virus followed by a new method to recover nucleic acid was used to detect hepatitis A virus (HAV) and rotavirus (SA11) in shellfish (oysters and hard-shell clams) by hybridization tests. Infectious virus, seeded into relatively large quantities of shellfish, was recovered consistently, with greater than 90% efficiency as measured by either in situ hybridization (HAV) or plaque assay (rotavirus SA11). Viral nucleic acid for dot blot hybridization assays was extracted and purified from virus-containing polyethylene glycol concentrates. Separation of shellfish polysaccharides from nucleic acid was necessary before viral RNA could be detected by dot blot hybridization. Removal of shellfish polysaccharides was accomplished by using the cationic detergent cetyltrimethylammonium bromide (CTAB). Use of CTAB reduced background interference with hybridization signals, which resulted in increased hybridization test sensitivity. After polysaccharide removal, dot blot hybridization assays could detect approximately 10(6) physical particles (corresponding to approximately 10(3) infectious particles) of HAV and 10(4) PFU of SA11 rotavirus present in 20-g samples of oyster and clam meats. These studies show continuing promise for the development of uniform methods to directly detect human viral pathogens in different types of shellfish. However, practical applications of such methods to detect noncultivatable human viral pathogens of public health interest will require additional improvements in test sensitivity.  相似文献   

7.
As part of our studies on the ecology of human enteric viruses, an improved method for detection of rotaviruses in water was developed, and their presence in Galveston Bay was monitored. Samples (378 liters) of estuarine water adjusted to pH 3.5 and a final AlCl3 molarity of 0.001 were filtered through 25-cm pleated cartridge-type filters (Filterite Corp., Timonium, Md.) of 3.0- and 0.45-micron porosity. Adsorbed virus was eluted with 1 liter of 10% tryptose phosphate broth, pH 9.5. Primary eluates were reconcentrated to a final volume of 10 to 20 ml by a simple and rapid magnetic iron oxide adsorption and elution procedure. Two percent casein at pH 8.5 effectively eluted rotavirus from iron oxide. A total of 21 of 72 samples of water, suspended solids, fluffy sediments, and compact sediments collected in different seasons in Galveston Bay yielded rotaviruses. Recovery of rotaviruses varied from 119 to 1,000 PFU/378 liters of water, 1,200 PFU/1,000 g of compact sediment, 800 to 3,800 PFU/378 liters of fluffy sediment, and 1,800 to 4,980 PFU from suspended solids derived from 378 liters of water based on immunofluorescent foci counts on cover slip cultures of fetal monkey kidney cells.  相似文献   

8.
As part of our studies on the ecology of human enteric viruses, an improved method for detection of rotaviruses in water was developed, and their presence in Galveston Bay was monitored. Samples (378 liters) of estuarine water adjusted to pH 3.5 and a final AlCl3 molarity of 0.001 were filtered through 25-cm pleated cartridge-type filters (Filterite Corp., Timonium, Md.) of 3.0- and 0.45-micron porosity. Adsorbed virus was eluted with 1 liter of 10% tryptose phosphate broth, pH 9.5. Primary eluates were reconcentrated to a final volume of 10 to 20 ml by a simple and rapid magnetic iron oxide adsorption and elution procedure. Two percent casein at pH 8.5 effectively eluted rotavirus from iron oxide. A total of 21 of 72 samples of water, suspended solids, fluffy sediments, and compact sediments collected in different seasons in Galveston Bay yielded rotaviruses. Recovery of rotaviruses varied from 119 to 1,000 PFU/378 liters of water, 1,200 PFU/1,000 g of compact sediment, 800 to 3,800 PFU/378 liters of fluffy sediment, and 1,800 to 4,980 PFU from suspended solids derived from 378 liters of water based on immunofluorescent foci counts on cover slip cultures of fetal monkey kidney cells.  相似文献   

9.
应用ELISA直接双抗体夹心法检查轮状病毒抗原,24份仔猪和29份犊牛的腹泻粪样,分别有12和16份阳性。用病毒RNA电泳分析检查阳性粪样,各出现两种病毒RNA电泳型,用中和试验检查17份成年牛和16份成年猪血清,分别有16和15份病毒抗体阳性。将其与ELISA间接法和结合法进行了比较。  相似文献   

10.
Long-term survival of human rotavirus in raw and treated river water   总被引:4,自引:0,他引:4  
This study was aimed at assessing the role of water as a vehicle for rotavirus spread by determining how well these viruses survive in the water environment. A cell culture adapted strain of human rotavirus subgroup 2, grown in MA-104 cells, was used as a model. Virus survival was tested in the following types of water samples, derived from the Ottawa River, at two different times of the year: (i) raw water (RW), (ii) muncipally treated tap water (TW), and (iii) raw water that had been filtered (FW) through a membrane (0.22 micron). The water samples, with approximately 5.0 X 10(4) plaque-forming units (PFU) of the virus, were held at either 4 or 20 degrees C and tested for infectious virus over a period of 64 days. The TW samples had a total and free chlorine content of 0.05 and less than 0.05 mg/L, respectively. The chlorine in these samples was not neutralized before virus contamination. Irrespective of the holding temperature, the virus titre in FW remained essentially unaltered throughout the test period. In TW held at 4 degrees C, there was no significant drop in the virus titre even after 64 days, whereas at 20 degrees C the titre in TW was reduced by about 2 log10 over the same period. Even though the loss of virus infectivity was most rapid in RW held at 20 degrees C, it took about 10 days for a 99.0% reduction in the plaque titre of the virus. These findings, therefore, indicate that rotaviruses can survive for several days in raw and treated river water thus making recreational and potable waters potential vehicles for the transmission of rotavirus infections.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号