首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Patellofemoral pain is common amongst recreational runners and associated with altered running kinematics. However, it is currently unclear how sex may influence kinematic differences previously reported in runners with patellofemoral pain. This case-control study aimed to evaluate lower limb kinematics in males and females with and without patellofemoral pain during running. Lower limb 3D kinematics were assessed in 20 runners with patellofemoral pain (11 females, 9 males) and 20 asymptomatic runners (11 females, 9 males) during a 3 km treadmill run. Variables of interest included peak hip adduction, internal rotation and flexion angles; and peak knee flexion angle, given their previously reported association with patellofemoral pain. Age, height, mass, weekly run distance and step rate were not significantly different between groups. Mixed-sex runners with patellofemoral pain were found to run with a significantly greater peak hip adduction angle (mean difference = 4.9°, d = 0.91, 95% CI 1.4–8.2, p = 0.01) when compared to matched controls, but analyses for all other kinematic variables were non-significant. Females with patellofemoral pain ran with a significantly greater peak hip adduction angle compared to female controls (mean difference = 6.6°, p = 0.02, F = 3.41, 95% CI 0.4–12.8). Analyses for all other kinematic variables between groups (males and females with/without PFP) were non-significant. Differences in peak hip adduction between those with and without patellofemoral pain during running appear to be driven by females. This potentially highlights different kinematic treatment targets between males and females. Future research is encouraged to report lower limb kinematic variables in runners with patellofemoral pain separately for males and females.  相似文献   

2.
The purpose of the present study was to determine the effects of orthoses designed to support the forefoot and rearfoot on the kinematics and kinetics of the lower extremity joints during walking. Fifteen participants volunteered for this study. Kinematic and kinetic variables during overground walking were compared with the participants wearing sandals without orthoses or sandals with orthoses. Orthoses increased knee internal abduction moment during late stance and knee abduction angular impulse, and reduced the medial ground reaction force during late stance, adduction free moment, forefoot eversion angle, ankle inversion moment and angular impulse, hip adduction angle, hip abduction moment, and hip external rotation moment and angular impulse (p<0.05). Orthoses decreased the torsional forces on the lower extremity and reduced the loading at the hip during walking. These findings combined with our previous studies and those of others suggest that forefoot abnormalities are critically important in influencing lower extremity kinematics and kinetics, and may underlie some non-traumatic lower extremity injuries.  相似文献   

3.
Female runners have a two-fold risk of sustaining certain running-related injuries as compared to their male counterparts. Thus, a comprehensive understanding of the sex-related differences in running kinematics is necessary. However, previous studies have either used discrete time point variables and inferential statistics and/or relatively small subject numbers. Therefore, the first purpose of this study was to use a principal component analysis (PCA) method along with a support vector machine (SVM) classifier to examine the differences in running gait kinematics between female and male runners across a large sample of the running population as well as between two age-specific sub-groups. Bilateral 3-dimensional lower extremity gait kinematic data were collected during treadmill running. Data were analysed on the complete sample (n = 483: female 263, male 220), a younger subject group (n = 56), and an older subject group (n = 51). The PC scores were first sorted by the percentage of variance explained and we also employed a novel approach wherein PCs were sorted based on between-gender statistical effect sizes. An SVM was used to determine if the sex and age conditions were separable and classifiable based on the PCA. Forty PCs explained 84.74% of the variance in the data and an SVM classification accuracy of 86.34% was found between female and male runners. Classification accuracies between genders for younger subjects were higher than a subgroup of older runners. The observed interactions between age and gender suggest these factors must be considered together when trying to create homogenous sub-groups for research purposes.  相似文献   

4.
The purpose of this study was to identify the gait strategies in women with mild and moderate knee osteoarthritis (OA). Forty women diagnosed with OA of the knee and 40 healthy women participated in the study. Toe-out progression angle, trunk lateral lean, hip internal abduction moment and gait speed were measured using Qualisys ProReflex System and two force plates. Principal component analysis was applied to extract features from the gait waveforms data that characterized the waveforms main modes of temporal variation. Discriminant analysis with a stepwise model was conducted to determine which strategies could best discriminate groups. According to the discriminant model, the PC2 of the internal abduction moment of the hip and the gait speed were the most discriminatory variables between the groups. The OA group showed decreased gait speed, decreased hip internal abduction moment during the loading response phase, and increased hip internal abduction moment during the mid and terminal stance phases. Interventions that may increase hip internal abduction moment, such as the strengthening of the hip abductors muscles, may benefit women with knee OA. Training slower than normal gait speeds must be considered in light of potential adverse implications on overall physical function, daily tasks, and safety.  相似文献   

5.
Tibial stress fractures are a common and debilitating injury that occur in distance runners. Runners may be able to decrease tibial stress fracture risk by adopting a running pattern that reduces biomechanical parameters associated with a history of tibial stress fracture. The purpose of this study was to test the hypothesis that converting to a forefoot striking pattern or increasing cadence without focusing on changing foot strike type would reduce injury risk parameters in recreational runners. Running kinematics, ground reaction forces and tibial accelerations were recorded from seventeen healthy, habitual rearfoot striking runners while running in their natural running pattern and after two acute retraining conditions: (1) converting to forefoot striking without focusing on cadence and (2) increasing cadence without focusing on foot strike. We found that converting to forefoot striking decreased two risk factors for tibial stress fracture: average and peak loading rates. Increasing cadence decreased one risk factor: peak hip adduction angle. Our results demonstrate that acute adaptation to forefoot striking reduces different injury risk parameters than acute adaptation to increased cadence and suggest that both modifications may reduce the risk of tibial stress fractures.  相似文献   

6.
Principal component analysis is a powerful tool in biomechanics for reducing complex multivariate datasets to a subset of important parameters. However, interpreting the biomechanical meaning of these parameters can be a subjective process. Biomechanical interpretations that are based on visual inspection of extreme 5th and 95th percentile waveforms may be confounded when extreme waveforms express more than one biomechanical feature. This study compares interpretation of principal components using representative extremes with a recently developed method, called single component reconstruction, which provides an uncontaminated visualization of each individual biomechanical feature. Example datasets from knee joint moments, lateral gastrocnemius EMG, and lumbar spine kinematics are used to demonstrate that the representative extremes method and single component reconstruction can yield equivalent interpretations of principal components. However, single component reconstruction interpretation cannot be contaminated by other components, which may enhance the use and understanding of principal component analysis within the biomechanics community.  相似文献   

7.
Stress fractures are a common and serious overuse injury in runners, particularly female runners. They may be related to loading characteristics of the lower extremity during running stance. Some tibial stress fractures (TSFs) are spiral in nature and, therefore, may be related to torque. Free moment (FM) is a measure of torque about a vertical axis at the interface with the shoe and ground. Increases in FM variables may be related to a history of TSF in runners. The purpose of this cross-sectional study was to investigate differences in FM between female distance runners with and without a history of TSF and, additionally, to investigate the relationship between absolute FM and the occurrence of TSF. A group of 25 currently uninjured female distance runners with a history of TSF (28+/-10 years, 46+/-15 km week(-1)) and an age- and mileage-matched control group of 25 healthy runners with no previous lower extremity fractures (26+/-9 years, 46+/-19 km week(-1)) participated in this study. Ground reaction forces and foot placement on the force platform were recorded during running at 3.7 ms(-1) (+/-5%). Peak adduction, braking peak and absolute peak FM and impulse were compared between groups using one-tailed t-tests. The predictive value of absolute peak FM was investigated via a binary logistic regression. All variables, except impulse, were significantly greater in runners with a history of TSF. Absolute peak FM had a significant predictive relationship with history of TSF. There is a significant relationship between higher values for FM variables and a history of TSF.  相似文献   

8.
This study aimed to identify adaptive changes in running kinematics and impact shock transmission as a function of head stability requirements. Fifteen strides from twelve recreational runners were collected during preferred speed treadmill running. Head stability demands were manipulated through real-time visual feedback that required head-gaze orientation to maintain within boxes of different sizes, ranging from 21° to 3° of visual angle with 3° decrements. The main outcome measures were tibial and head peak accelerations in the time and frequency domains (impact and active phases), shock transmission from tibia to head, stride parameters, and sagittal plane joint kinematics. Increasing head stability requirements resulted in decreases in the amplitude and integrated power of head acceleration during the active phase of stance. During the impact portion of stance tibial and head acceleration and shock transmission remained similar across visual conditions. In response to increased head stability requirements, participants increased stride frequency approximately 8% above preferred, as well as hip flexion angle at impact; stance time and knee and ankle joint angles at impact did not change. Changes in lower limb joint configurations (smaller hip extension and ankle plantar-flexion and greater knee flexion) occurred at toe-off and likely contributed to reducing the vertical displacement of the center of mass with increased head stability demands. These adaptive changes in the lower limb enabled runners to increase the time that voluntary control is allowed without embedding additional impact loadings, and therefore active control of the head orientation was facilitated in response to different visual task constraints.  相似文献   

9.
The purpose of this study was to assess the reproducibility of fascicle length (FL) and pennation angle (PA) of gastrocnemius medialis (GM) muscle during running in vivo. Twelve male recreational long distance runners (mean ± SD; age: 24 ± 3 years, mass: 76 ± 7 kg) ran on a treadmill at a speed of 3.0 m/s, wearing their own running shoes, for two different 10 min sessions that were at least 2 days apart. For each test day 10 acceptable trials were recorded. Ankle and knee joint angle data were recorded by a Vicon 624 system with three cameras operating at 120 Hz. B-mode ultrasonography was used to examine fascicle length and pennation angle of gastrocnemius medialis muscle. The ultrasound probe was firmly secured on the muscle belly using a lightweight foam fixation. The results indicated that fascicle length and pennation angle demonstrated high reproducibility values during treadmill running both for within and between test days. The root mean square scores between the repeated waveforms of pennation angle and fascicle length were small (∼2° and ∼3.5 mm, respectively). However, ∼14 trials for pennation angle and ∼9 trials for fascicle length may be required in order to record accurate data from muscle architecture parameters. In conclusion, ultrasound measurements may be highly reproducible during dynamic movements such as treadmill running, provided that a proper fixation is used in order to assure the constant location and orientation of the ultrasound probe throughout the movement.  相似文献   

10.
Researchers conduct gait analyses utilizing both overground and treadmill modes of running. Previous studies comparing these modes analyzed discrete variables. Recently, techniques involving quantitative pattern analysis have assessed kinematic curve similarity in gait. Therefore, the purpose of this study was to compare hip, knee and rearfoot 3-D kinematics between overground and treadmill running using quantitative kinematic curve analysis. Twenty runners ran at 3.35 m/s ± 5% during treadmill and overground conditions while right lower extremity kinematics were recorded. Kinematics of the hip, knee and rearfoot at footstrike and peak were compared using intraclass correlation coefficients. Kinematic curves during stance phase were compared using the trend symmetry method within each subject. The overall average trend symmetry was high, 0.94 (1.0 is perfect symmetry) between running modes. The transverse plane and knee frontal plane exhibited lower similarity (0.86-0.90). Other than a 4.5 degree reduction in rearfoot dorsiflexion at footstrike during treadmill running, all differences were ≤1.5 degrees. 17/18 discrete variables exhibited modest correlations (>0.6) and 8/18 exhibited strong correlations (>0.8). In conclusion, overground and treadmill running kinematic curves were generally similar when averaged across subjects. Although some subjects exhibited differences in transverse plane curves, overall, treadmill running was representative of overground running for most subjects.  相似文献   

11.
The flow properties of typial tablet and capsule formulation excipients, active compounds, and representative formulation blends were tested with current and novel flow measurement techniques to identify a reliable bench test to quantify powder flow as a screening method in early tablet and capsule formulation development. Test methods employed were vibrating spatula, critical orifice, angle of repose, compressibility index, and avalanching analysis. Powder flow results from each method were compiled in a database, sorted, and compared. An empirical composite index was established and powder flow was ranked in accordance with formulator experience. Principal components analyses of the angle of repose, percent compressibility, and critical orifice of the powder materials were also performed. The first principal component accounted for 72.8% of data variability; scores associated with this principal component score can serve as an index of flowability. Data generated from vibrating spatula and avalanching methods were not reproducible and were inconsistent with formulator experience and cited vendor references for flow. Improvements of test instruments and further studies are necessary for better assessment of these approaches.  相似文献   

12.
Metal-on-metal hip resurfacing patients demonstrate hip biomechanics closer to normal in comparison to total hip arthroplasty during gait. However, it is not clear how symmetric is the gait of hip resurfacing patients. Biomechanical data of 12 unilateral metal-on-metal hip resurfacing participants were collected during gait at a mean time of 45 months (SD 24) after surgery. Ankle, knee, hip, pelvis and trunk kinematics and kinetics of both sides were measured with a motion and force-capture system. Principal component analysis and mean hypothesis’ tests were used to compare the operated and healthy sides. The operated side had prolonged ankle eversion angle during late stance and delayed increased ankle inversion angle during early swing (p = 0.008; effect size = 0.70), increased ankle inversion moment during late stance (p = 0.001; effect size = 0.78), increased knee adduction angle during swing (p = 0.044; effect size = 0.57), decreased knee abduction moment during stance (p = 0.05; effect size = 0.40), decreased hip range of motion in the sagittal plane (p = 0.046; effect size = 0.56), decreased range of hip abduction moment during stance (p = 0.02; effect size = 0.63), increased hip range of motion in the transverse plane (p = 0.02; effect size = 0.62), decreased hip internal rotation moment during the transition from loading response to midstance (p = 0.001; effect size = 0.81) and increased trunk ipsilateral lean (p = 0.03; effect size = 0.60). Therefore, hip resurfacing patients have some degree of asymmetry in long term, which may be related to hip weakness and decreased range of motion, to foot misalignments and to strategies implemented to reduce loading on the operated hip. Interventions such as muscle strengthening and stretching, insoles and gait feedback training may help improving symmetry following hip resurfacing.  相似文献   

13.
To investigate the biomechanical strategy adopted by older adults with medial compartment knee osteoarthritis (OA) for successful obstacle crossing with the trailing limb, and to discuss its implications for fall-prevention, 15 older adults with bilateral medial compartment knee OA and 15 healthy controls were recruited to walk and cross obstacles of heights of 10%, 20%, and 30% of their leg lengths. Kinematic and kinetic data were obtained using a three-dimensional (3D) motion analysis system and forceplates. The OA group had higher trailing toe clearance than the controls. When the trailing toe was above the obstacle, the OA group showed greater swing hip abduction, yet smaller stance hip adduction, knee flexion, and ankle eversion. They showed greater pelvic anterior tilt and toe-out angle. They also exhibited greater peak knee abductor moments during early stance and at the instant when the swing toe was above the obstacle, while a greater peak hip abductor moment was found during late stance. Smaller knee extensor, yet greater hip extensor moments, were found in the OA group throughout the stance phase. In order to achieve higher toe clearance with knee OA, particular joint kinematic and kinetic strategies have been adopted by the OA group. Weakness in the hip abductors and extensors in individuals with OA may be risk factors for tripping owing to the greater demands on these muscle groups during obstacle crossing by these individuals.  相似文献   

14.
The polar-lipid composition of the placenta reflects its cellular heterogeneity and metabolism. This study explored relationships between placental polar-lipid composition, gene expression and neonatal body composition.Placental tissue and maternal and offspring data were collected in the Southampton Women's Survey. Lipid and RNA were extracted from placental tissue and polar lipids measured by mass spectrometry, while gene expression was assessed using the nCounter analysis platform. Principal component analysis was used to identify patterns within placental lipid composition and these were correlated with neonatal body composition and placental gene expression.In the analysis of placental lipids, the first three principal components explained 19.1%, 12.7% and 8.0% of variation in placental lipid composition, respectively. Principal component 2 was characterised by high principal component scores for acyl-alkyl-glycerophosphatidylcholines and lipid species containing DHA. Principal component 2 was associated with placental weight and neonatal lean mass; this component was associated with gene expression of APOE, PLIN2, FATP2, FABP4, LEP, G0S2, PNPLA2 and SRB1. Principal components 1 and 3 were not related to birth outcomes but they were associated with the gene expression of lipid related genes. Principal component 1 was associated with expression of LEP, APOE, FATP2 and ACAT2. Principal component 3 was associated with expression of PLIN2, PLIN3 and PNPLA2.This study demonstrates that placentas of different sizes have specific differences in polar-lipid composition and related gene expression. These differences in lipid composition were associated with birth weight and neonatal lean mass, suggesting that placental lipid composition may influence prenatal lean mass accretion.  相似文献   

15.
Knowledge of accurate in-vivo 6 degree-of-freedom (6-DOF) kinematics of total hip arthroplasty (THA) during daily activities is critical for improvement of longevity of the components. Previous studies assessed in-vivo THA kinematics using skin marker-based motion analysis. However, skin markers are prone to move with respect to the underlying bones. A non-invasive dual fluoroscopic imaging system (DFIS) based tracking technique has been used to avoid skin artifacts and provide accurate 6-DOF kinematic measurement. This study aimed to quantify in-vivo 6-DOF THA kinematics during gait using DFIS. Twenty eight well-functioning THAs were evaluated during treadmill gait under DFIS surveillance. The maximum translations of the femoral head were 0.46±0.10 mm and 0.45±0.10 mm during the stance and swing phases (p=0.57), respectively. The range of hip flexion was from 8.7° to 47.6°, adduction from 3.0° to 12.5° and external rotation from 19.2° to 29.7°. The THA was flexed, externally rotated and adducted throughout the gait. The magnitudes of the femoral head translations were found to be within the manufacture tolerance of the components, suggesting that in-vivo hip “pistoning” during gait cycle may be minimal in well-functioning THAs. The 6-DOF kinematics could be used as the baseline knowledge for further improvement of wear-testing of hip implant, implants manufacturing and implant positioning during surgery.  相似文献   

16.
There appears a linear relationship between small increases in running speed and cardiovascular health benefits. Encouraging or coaching recreational runners to increase their running speed to derive these health benefits might be more effective if their joint level kinematic and kinetic strategy was understood. The aim of this investigation was to compare the peak sagittal plane motions, moments, and powers of the hip, knee and ankle at 85%, 100%, 115% and 130% of self-selected running speed. Overground running data were collected in 12 recreational runners (6 women, 6 men) with a full body marker set using a 12-camera Vicon MX system with an AMTI force plate. Kinematics and kinetics were analyzed with Vicon Nexus software. Participants chose to run at 2.6 ± 0.5 m/s (85%); 3.0 ± 0.5 m/s (100%); 3.3 ± 0.5 m/s (115%); and 3.7 ± 0.5 m/s (130%); these four speeds approximately correspond to 6:24-, 5:33-, 5:03-, and 4:30-min kilometer running paces. Running speed had a significant effect (P < 0.05) on peak kinematic and kinetic variables of the hips, knees and ankles, with peak sagittal hip moments invariant (P > 0.54) and the peak sagittal ankle power generation (P < 0.0001) the most highly responsive variable. The timing of the peak sagittal extensor moments and powers at the hip, knee and ankle were distributed across stance in a sequential manner. This study shows that running speed affects lower limb joint kinematics and kinetics and suggests that specific intersegmental kinetic strategies might exist across the narrow range of running speeds.  相似文献   

17.
Carbon fiber running-specific prostheses (RSPs) have allowed individuals with lower extremity amputation (ILEA) to participate in running. It has been established that as running speed increases, leg stiffness (Kleg) remains constant while vertical stiffness (Kvert) increases in able-bodied runners. The Kvert further depends on a combination of the torsional stiffnesses of the joints (joint stiffness; Kjoint) and the touchdown joint angles. Thus, an increased understanding of spring-like leg function and stiffness regulation in ILEA runners using RSPs is expected to aid in prosthetic design and rehabilitation strategies. The aim of this study was to investigate stiffness regulation to various overground running speeds in ILEA wearing RSPs. Eight ILEA performed overground running at a range of running speeds. Kleg, Kvert and Kjoint were calculated from kinetic and kinematic data in both the intact and prosthetic limbs. Kleg and Kvert in both the limbs remained constant when running speed increased, while intact limbs in ILEA running with RSPs have a higher Kleg and Kvert than residual limbs. There were no significant differences in Kankle, Kknee and touchdown knee angle between the legs at all running speeds. Hip joints in both the legs did not demonstrate spring-like function; however, distinct impact peaks were observed only in the intact leg hip extension moment at the early stance phase, indicating that differences in Kvert between limbs in ILEA are due to attenuating shock with the hip joint. Therefore, these results suggest that ILEA using RSPs has a different stiffness regulation between the intact and prosthetic limbs during running.  相似文献   

18.
Running research has focused on reducing injuries by changing running technique. One proposed method is to change from rearfoot striking (RFS) to forefoot striking (FFS) because FFS is thought to be a more natural running pattern that may reduce loading and injury risk. Muscle activity affects loading and influences running patterns; however, the differences in muscle activity between natural FFS runners and natural RFS runners are unknown. The purpose of this study was to measure muscle activity in natural FFS runners and natural RFS runners. We tested the hypotheses that tibialis anterior activity would be significantly lower while activity of the plantarflexors would be significantly greater in FFS runners, compared to RFS runners, during late swing phase and early stance phase. Gait kinematics, ground reaction forces and electromyographic patterns of ten muscles were collected from twelve natural RFS runners and ten natural FFS runners. The root mean square (RMS) of each muscle?s activity was calculated during terminal swing phase and early stance phase. We found significantly lower RMS activity in the tibialis anterior in FFS runners during terminal swing phase, compared to RFS runners. In contrast, the medial and lateral gastrocnemius showed significantly greater RMS activity in terminal swing phase in FFS runners. No significant differences were found during early stance phase for the tibialis anterior or the plantarflexors. Recognizing the differences in muscle activity between FFS and RFS runners is an important step toward understanding how foot strike patterns may contribute to different types of injury.  相似文献   

19.
Research concerning forefoot strike pattern (FFS) versus rearfoot strike pattern (RFS) running has focused on the ground reaction force even though internal joint contact forces are a more direct measure of the loads responsible for injury. The main purpose of this study was to determine the internal loading of the joints for each strike pattern. A secondary purpose was to determine if converted FFS and RFS runners can adequately represent habitual runners with regards to the internal joint loading. Using inverse dynamics to calculate the net joint moments and reaction forces and optimization techniques to estimate muscle forces, we determined the axial compressive loading at the ankle, knee, and hip. Subjects consisted of 15 habitual FFS and 15 habitual RFS competitive runners. Each subject ran at a preferred running velocity with their habitual strike pattern and then converted to the opposite strike pattern. Plantar flexor muscle forces and net ankle joint moments were greater in the FFS running compared to the RFS running during the first half of the stance phase. The average contact forces during this period increased by 41.7% at the ankle and 14.4% at the knee joint during FFS running. Peak ankle joint contact force was 1.5 body weights greater during FFS running (p<0.05). There was no evidence to support a difference between habitual and converted running for joint contact forces. The increased loading at the ankle joint for FFS is an area of concern for individuals considering altering their foot strike pattern.  相似文献   

20.
Participation in running events has increased recently, with a concomitant increase in the rate of running related injuries (RRI). Mechanical overload is thought to be a primary cause of RRI, it is often detected using motion analysis to examine running mechanics during either overground or treadmill running. In treadmill running, no clear consensus for the number of strides required to establish stable kinematic data exists. The aim of this study was to establish the number of strides needed for stable data when analysing gait kinematics in the stance phase of treadmill running. Twenty healthy, masters age group, club runners completed a high intensity interval training run (HIIT) and an energy-expenditure matched medium intensity continuous run (MICR). Thirty consecutive strides at start and end of each run were identified. Sequential averaging was employed to determine the number of strides required to establish a stable value. No significant differences existed in the number of strides required to achieve stable values. Twenty consecutive strides are required to be 95% confident stable values exist for maximum angle, angle at initial foot contact, and range of motion at the ankle, knee, and hip joints variables at the ankle, knee, and hip joints, in all three planes of motion, and spatiotemporal regardless of running speed and time of capture.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号