1.
PurposeTo generate pseudo low monoenergetic CT images of the abdomen from 120-kVp CT images with cGAN.Materials and MethodsWe retrospectively included 48 patients who underwent contrast-enhanced abdominal CT using dual-energy CT. We reconstructed paired data sets of 120 kVp CT images and virtual low monoenergetic (55-keV) CT images. cGAN was prepared to generate pseudo 55-keV CT images from 120-kVp CT images. The pseudo 55 keV CT images in epoch 10, 50, 100, and 500 were compared to the 55 keV images generated using peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM).ResultsThe PSNRs were 28.0, 28.5, 28.6, and 28.8 at epochs 10, 50, 100, and 500, respectively. The SSIM was approximately constant from epochs 50 to 500.ConclusionPseudo low monoenergetic abdominal CT images were generated from 120-kVp CT images using cGAN, and the images had good quality similar to that of monochromatic images obtained with DECT software.  相似文献   

2.
PurposeTo investigate differences in image-to-image variations between full- and half-scan reconstruction on myocardial CT perfusion (CTP) study.MethodsUsing a cardiac phantom we performed ECG-gated myocardial CTP on a second-generation 320-multidetector CT volume scanner. The heart rate was set at 60 bpm; once per second for a total of 24 s were performed. CT images were acquired at 80- and 120 kVp and subjected to full- and half-scan reconstruction. On images acquired at the same slice level we then measured image-to-image variations, coefficients of variance (CV), and image noise.ResultsThe image-to-image variations with full- and half-scan reconstruction were 1.3 HU vs. 27.2 HU at 80 kVp (p < 0.001) and 0.70 HU vs. 9.3 HU at 120 kVp (p < 0.001) even though the mean HU value was almost the same for both reconstruction methods. The CV of 80- and 120-kVp images of the left ventricular cavity decreased by 0.16% and 0.17%, respectively, with full-scan reconstruction; with half-scan reconstruction it decreased by 3.34% and 2.30%, respectively. Compared with half-scan reconstruction, the image noise was reduced by 27.2% at 80 kVp and by 28.0% at 120 kVp with full-scan reconstruction.ConclusionMyocardial CTP with full-scan reconstruction substantially decreased image-to-image variations and provided accurate CT attenuation.  相似文献   

3.
PurposeHybrid iterative reconstruction (IR) is useful to reduce noise in computed tomography (CT) images. However, it often decreases the spatial resolution. The ability of high spatial resolution kernels (harder kernels) to compensate for the decrease in the spatial resolution of hybrid IRs was investigated.MethodsAn elliptic cylindrical phantom simulating an adult abdomen was used. Two types of rod-shaped objects with ~330 and ~130 HU were inserted to simulate contrasts of arteries in CT angiography. Two multi-slice CT systems were used to scan the phantoms with 120 kVp and scan doses of 20 and 10 mGy. The task transfer functions (TTFs) were measured from the circular edges of the rod images. The noise power spectrum (NPS) was measured from the images of the water-only section. The CT images were reconstructed using a filtered back projection (FBP) with baseline kernels and two levels of hybrid IRs with harder kernels. The profiles of the clinical images across the aortic dissection flaps were measured to evaluate actual spatial resolutions.ResultsThe TTF degradation of each hybrid IR was recovered by the harder kernels, whereas the noise reduction effect was retained, for both the 20 and 10 mGy. The profiles of the dissection flaps for the FBP were maintained by using the harder kernels. Even with the best combination of hybrid IR and harder kernel, the noise level at 10 mGy was not reduced to the level of FBP at 20 mGy, suggesting no capability of a 50% dose reduction while maintaining noise.  相似文献   

4.
PurposeTo determine the suitable kVp pair for optimal image quality of the virtual monochromatic images (VMIs) and iodine quantification accuracy at low concentration, using a third generation dual-source CT (DSCT).Materials and methodsMulti-energy CT phantoms with and without body rings were scanned with a DSCT using four kVp pairs (tube “A”/“B” voltage): 100/Sn150, 90/Sn150, 80/Sn150 and 70/Sn150 kVp. The reference mAs was adjusted to obtain a CTDIvol close to 11 mGy. HU values accuracy (RMSDHU), noise (SD) and contrast-to-noise ratio (CNR) of iodine inserts of 0.5, 1, 2 and 5 mg/mL concentrations were assessed on VMIs at 40/50/60/70 keV. Iodine quantification accuracy was assessed using the RMSDiodine and iodine bias (IBiodine).ResultsThe RMSDHU decreased when the tube “A” voltage increased. The mean noise value increased significantly with tube “A” voltage (p < 0.001) but decreased between 80/Sn150 and 90/Sn150 kVp for the small phantom (1.1 ± 0.1%; p = 0.047). The CNR significantly decreased with tube “A” voltage (p < 0.001), except between 80/Sn150 and 90/Sn150 kVp for all inserts and between 90/Sn150 kVp and 100/Sn150 kVp for the 1.0 and 0.5 mg/mL inserts in the large phantom. In the small phantom, no significant difference was found between 80/Sn150 kVp and 90/Sn150 kVp for all inserts and between 80/Sn150, 90/Sn150 and 100/Sn150 kVp for the 1 and 0.5 mg/mL inserts. The RMSDiodine and IBiodine decreased as the tube “A” voltage of the kVp pair increased.ConclusionThe kVp pair of 70/Sn150 led to better image quality in VMIs and sufficient iodine accuracy.  相似文献   

5.
PurposeTo quantitatively assess CT image quality and fracture visibility using virtual monochromatic imaging and iterative metal artifact reduction (iMAR) in a femoral bone fracture phantom with different fixation implants.MethodsA custom made phantom was scanned at 120-kVp and 140-kVp single-energy and 100/150-kVp dual-energy. Three stainless steel and two titanium implants with different thicknesses were placed on the phantom containing simulated one and two mm fractures. Single-energy CT images were reconstructed with and without iMAR, while DECT images were reconstructed at monochromatic energies between 70 and 190 keV. Non-metal scans were used as a reference. A Fourier power spectrum method and fracture model were used to analyze several anatomical areas.ResultsCT-value deviations of titanium implants were much lower compared to stainless steel implants. These deviations decreased for both DECT and iMAR. Fracture visibility, measured with the fracture model, improved the most when DECT was used while artifact reduction benefitted more from iMAR. The optimal monochromatic energy for metal artifact reduction, based on CT-value deviation, varied for each metal between 130 and 150 keV. The fracture model provided a signal-to-noise ratio for the near metal fracture visibility, providing the optimal keV.ConclusioniMAR and high keV monochromatic images extracted from DECT both reduce metal artifacts caused by different metal fixation implants. Quantitative femoral phantom results show that DECT is superior to iMAR regarding fracture visualization adjacent to metal fixation implants. The introduction of new artifacts when using iMAR impedes its value in near metal fixation implant imaging.  相似文献   

6.
PurposeWe used pediatric and adult anthropomorphic phantoms to compare the radiation dose of low- and standard tube voltage chest and abdominal non-contrast-enhanced computed tomography (CT) scans. We also discuss the optimal low tube voltage for non-contrast-enhanced CT.MethodsUsing a female adult- and three differently-sized pediatric anthropomorphic phantoms we acquired chest and abdominal non-contrast-enhanced scans on a 320-multidetector CT volume scanner. The tube voltage was set at 80-, 100-, and 120 kVp. The tube current was automatically assigned on the CT scanner in response to the set image noise level. On each phantom and at each tube voltage we measured the surface and center dose using high-sensitivity metal-oxide-semiconductor field-effect transistor detectors.ResultsThe mean surface dose of chest and abdominal CT scans in 5-year olds was 4.4 and 5.3 mGy at 80 kVp, 4.5 and 5.4 mGy at 100 kV, and 4.0 and 5.0 mGy at 120 kVp, respectively. These values were similar in our 3-pediatric phantoms (p > 0.05). The mean surface dose in the adult phantom increased from 14.7 to 19.4 mGy for chest- and from 18.7 to 24.8 mGy for abdominal CT as the tube voltage decreased from 120 to 80 kVp (p < 0.01).ConclusionCompared to adults, the surface and center dose for pediatric patients is almost the same despite a decrease in the tube voltage and the low tube voltage technique can be used for non-contrast-enhanced chest- and abdominal scanning.  相似文献   

7.
By using the CT images obtained by subtracting two CT images acquired under the same conditions and slice locations, we have devised a method for detecting streak artifacts in non-uniform regions and only radiological noise components in CT images. A chest phantom was scanned using 16- and 64-multidetector row helical CT scanners with various mAs values at 120 kVp. The upper lung slice image was employed as a target image for evaluating the streak artifacts and radiological noise. One hundred parallel line segments with a length of 80 pixels were placed on the subtracted CT image, and the largest CT value in each CT value profile was employed as a feature variable of the streak artifacts; these feature variables were analyzed with the extreme value theory (Gumbel distribution). To detect only the radiological noise, all CT values contained in the 100 line profile were plotted on normal probability paper and the standard deviation was estimated from the inclination of its fitted line for the CT value plots. The two detection methods devised in this study were able to evaluate the streak artifacts and radiological noise in the CT images with high accuracy.  相似文献   

8.
Background and purposeTo evaluate the impact of deformation magnitude and image modality on deformable-image-registration (DIR) accuracy using Halcyon megavoltage cone beam CT images (MVCBCT).Materials and methodsPlanning CT images of an anthropomorphic Head phantom were aligned rigidly with MVCBCT and re-sampled to achieve the same resolution, denoted as pCT. MVCBCT was warped with twenty simulated pre-known virtual deformation fields (Ti, i = 1–20) with increasing deformation magnitudes, yielding warped CBCT (wCBCT). The pCT and MVCBCT were registered to wCBCT respectively (Multi-modality and Uni-modality DIR), generating deformation vector fields Vi and Vi′ (i = 1–20). Vi and Vi′ were compared with Ti respectively to assess the DIR accuracy geometrically. In addition, Vi, Ti, and Vi′ were applied to pCT, generating deformed CT (dCTi), ground-truth CT (Gi) and deformed CT′ (dCTi′) respectively. The Hounsfield Unit (HU) on these virtual CT images were also compared.ResultsThe mean errors of vector displacement increased with the deformation magnitude. For deformation magnitudes between 2.82 mm and 7.71 mm, the errors of uni-modality DIR were 1.16 mm ~ 1.73 mm smaller than that of multi-modality (p = 0.0001, Wilcoxon signed rank test). DIR could reduce the maximum signed and absolute HU deviations from 70.8 HU to 11.4 HU and 208 HU to 46.2 HU respectively.ConclusionsAs deformation magnitude increases, DIR accuracy continues to deteriorate and uni-modality DIR consistently outperformed multi-modality DIR. DIR-based adaptive radiotherapy utilizing the noisy MVCBCT images is only conditionally applicable with caution.  相似文献   

9.
PurposeSimulating low-dose Computed Tomography (CT) facilitates in-silico studies into the required dose for a diagnostic task. Conventionally, low-dose CT images are created by adding noise to the projection data. However, in practice the raw data is often simply not available. This paper presents a new method for simulating patient-specific, low-dose CT images without the need of the original projection data.MethodsThe low-dose CT simulation method included the following: (1) computation of a virtual sinogram from a high dose CT image through a radon transform; (2) simulation of a ‘reduced’-dose sinogram with appropriate amounts of noise; (3) subtraction of the high-dose virtual sinogram from the reduced-dose sinogram; (4) reconstruction of a noise volume via filtered back-projection; (5) addition of the noise image to the original high-dose image. The required scanner-specific parameters, such as the apodization window, bowtie filter, the X-ray tube output parameter (reflecting the photon flux) and the detector read-out noise, were retrieved from calibration images of a water cylinder. The low-dose simulation method was evaluated by comparing the noise characteristics in simulated images with experimentally acquired data.ResultsThe models used to recover the scanner-specific parameters fitted accurately to the calibration data, and the values of the parameters were comparable to values reported in literature. Finally, the simulated low-dose images accurately reproduced the noise characteristics in experimentally acquired low-dose-volumes.ConclusionThe developed methods truthfully simulate low-dose CT imaging for a specific scanner and reconstruction using filtered backprojection. The scanner-specific parameters can be estimated from calibration data.  相似文献   

10.
PurposeA novel fast kilovoltage switching dual-energy CT with deep learning [Deep learning based-spectral CT (DL-Spectral CT)], which generates a complete sinogram for each kilovolt using deep learning views that complement the measured views at each energy, was commercialized in 2020. The purpose of this study was to evaluate the accuracy of CT numbers in virtual monochromatic images (VMIs) and iodine quantifications at various radiation doses using DL-Spectral CT.Materials and methodsTwo multi-energy phantoms (large and small) using several rods representing different materials (iodine, calcium, blood, and adipose) were scanned by DL-Spectral CT at varying radiation doses. Images were reconstructed using three reconstruction parameters (body, lung, bone). The absolute percentage errors (APEs) for CT numbers on VMIs at 50, 70, and 100 keV and iodine quantification were compared among different radiation dose protocols.ResultsThe APEs of the CT numbers on VMIs were <15% in both the large and small phantoms, except at the minimum dose in the large phantom. There were no significant differences among radiation dose protocols in computed tomography dose index volumes of 12.3 mGy or larger. The accuracy of iodine quantification provided by the body parameter was significantly better than those obtained with the lung and bone parameters. Increasing the radiation dose did not always improve the accuracy of iodine quantification, regardless of the reconstruction parameter and phantom size.ConclusionThe accuracy of iodine quantification and CT numbers on VMIs in DL-Spectral CT was not affected by the radiation dose, except for an extremely low radiation dose for body size.  相似文献   

11.
ObjectiveTo assess the image quality of aorta obtained by dual-source computed tomography angiography (DSCTA), performed with high pitch, low tube voltage, and low iodine concentration contrast medium (CM) with images reconstructed using iterative reconstruction (IR).MethodsOne hundred patients randomly allocated to receive one of two types of CM underwent DSCTA with the electrocardiogram-triggered Flash protocol. In the low-iodine group, 50 patients received CM containing 270 mg I/mL and were scanned at low tube voltage (100 kVp). In the high-iodine CM group, 50 patients received CM containing 370 mg I/mL and were scanned at the tube voltage (120 kVp). The filtered back projection (FBP) algorithm was used for reconstruction in both groups. In addition, the IR algorithm was used in the low-iodine group. Image quality of the aorta was analyzed subjectively by a 3-point grading scale and objectively by measuring the CT attenuation in terms of the signal- and contrast-to-noise ratios (SNR and CNR, respectively). Radiation and CM doses were compared.ResultsThe CT attenuation, subjective image quality assessment, SNR, and CNR of various aortic regions of interest did not differ significantly between two groups. In the low-iodine group, images reconstructed by FBP and IR demonstrated significant differences in image noise, SNR, and CNR (p<0.05). The low-iodine group resulted in 34.3% less radiation (4.4 ± 0.5 mSv) than the high-iodine group (6.7 ± 0.6 mSv), and 27.3% less iodine weight (20.36 ± 2.65 g) than the high-iodine group (28 ± 1.98 g). Observers exhibited excellent agreement on the aortic image quality scores (κ = 0.904).ConclusionsCT images of aorta could be obtained within 2 s by using a DSCT Flash protocol with low tube voltage, IR, and low-iodine-concentration CM. Appropriate contrast enhancement was achieved while maintaining good image quality and decreasing the radiation and iodine doses.  相似文献   

12.
PurposeTo measure the combined errors due to geometric inaccuracy and image co-registration on secondary images (dynamic CT angiography (dCTA), 3D DynaCT angiography (DynaCTA), and magnetic resonance images (MRI)) that are routinely used to aid in target delineation and planning for stereotactic radiosurgery (SRS).MethodsThree phantoms (one commercial and two in-house built) and two different analysis approaches (commercial and MATLAB based) were used to quantify the magnitude of geometric image distortion and co-registration errors for different imaging modalities within CyberKnife’s MultiPlan treatment planning software. For each phantom, the combined errors were reported as a mean target registration error (TRE). The mean TRE’s for different intramodality imaging parameters (e.g., mAs, kVp, and phantom set-ups) and for dCTA, DynaCTA, and MRI systems were measured.ResultsOnly X-ray based imaging can be performed with the commercial phantom, and the mean TRE ± standard deviation values were large compared to the in-house analysis using MATLAB. With the 3D printed phantom, even drastic changes in treatment planning CT imaging protocols did not greatly influence the mean TRE (<0.5 mm for a 1 mm slice thickness CT). For all imaging modalities, the largest mean TRE was found on DynaCT, followed by T2-weighted MR images (albeit all <1 mm).ConclusionsThe user may overestimate the mean TRE if the commercial phantom and MultiPlan were used solely. The 3D printed phantom design is a sensitive and suitable quality assurance tool for measuring 3D geometric inaccuracy and co-registration errors across all imaging modalities.  相似文献   

13.
PurposeTo assess the impact of iterative reconstructions on image quality and detectability of focal liver lesions in low-energy monochromatic images from a Fast kV-Switching Dual Energy CT (KVSCT) platform.MethodsAcquisitions on an image-quality phantom were performed using a KVSCT for three dose levels (CTDIvol:12.72/10.76/8.79 mGy). Raw data were reconstructed for five energy levels (40/50/60/70/80 keV) using Filtered Back Projection (FBP) and four levels of ASIR (ASIR30/ASIR50/ASIR70/ASIR100). Noise power spectrum (NPS) and task-based transfer function (TTF) were measured before computing a Detectability index (d′) to model the detection task of liver metastasis (LM) and hepatocellular carcinoma (HCC) as function of keV.ResultsFrom 40 to 70 keV, noise-magnitude was reduced on average by −68% ± 1% with FBP; −61% ± 3% with ASIR50 and −52% ± 6% with ASIR100. The mean spatial frequency of the NPS decreased when the energy level decreased and the iterative level increased. TTF values at 50% decreased as the energy level increased and as the percentage of ASIR increased. The detectability of both lesions increased with increasing dose level and percentage of ASIR. For the LM, d′ peaked at 70 keV for all reconstruction types, except for ASIR70 at 12.72 mGy and ASIR100, where d' peaked at 50 keV. For HCC, d’ peaked at 60 keV for FBP and ASIR30 but peaked at 50 keV for ASIR50, ASIR70 and ASIR100.ConclusionsUsing percentage of ASIR above 50% at low-energy monochromatic images could limit the increase of noise-magnitude, benefit from spatial resolution improvement and hence enhance detectability of subtle low contrast focal liver lesions such as HCC.  相似文献   

14.
PurposeTo investigate whether electrocardiogram (ECG)-gated single- and dual-heartbeat computed tomography coronary angiography (CTCA) with automatic exposure control (AEC) yields images with uniform image noise at reduced radiation doses.Materials and methodsUsing an anthropomorphic chest CT phantom we performed prospectively ECG-gated single- and dual-heartbeat CTCA on a second-generation 320-multidetector CT volume scanner. The exposure phase window was set at 75%, 70–80%, 40–80%, and 0–100% and the heart rate at 60 or 80 or corr80 bpm; images were reconstructed with filtered back projection (FBP) or iterative reconstruction (IR, adaptive iterative dose reduction 3D). We applied AEC and set the image noise level to 20 or 25 HU. For each technique we determined the image noise and the radiation dose to the phantom center.ResultsWith half-scan reconstruction at 60 bpm, a 70–80% phase window- and a 20-HU standard deviation (SD) setting, the imagenoise level and -variation along the z axis manifested similar curves with FBP and IR. With half-scan reconstruction, the radiation dose to the phantom center with 70–80% phase window was 18.89 and 12.34 mGy for FBP and 4.61 and 3.10 mGy for IR at an SD setting SD of 20 and 25 HU, respectively. At 80 bpm with two-segment reconstruction the dose was approximately twice that of 60 bpm at both SD settings. However, increasing radiation dose at corr80 bpm was suppressed to 1.39 times compared to 60 bpm.ConclusionAEC at ECG-gated single- and dual-heartbeat CTCA controls the image noise at different radiation dose.  相似文献   

15.
PurposeTo assess the quality of images obtained on a dual energy computed tomography (CT) scanner.MethodsImage quality was assessed on a 64 detector-row fast kVp-switching dual energy CT scanner (Revolution GSI, GE Medical Systems). The Catphan phantom and a low contrast resolution phantom were employed. Acquisitions were performed at eight different radiation dose levels that ranged from 9 mGy to 32 mGy. Virtual monochromatic spectral images (VMI) were reconstructed in the 40–140 keV range using all available kernels and iterative reconstruction (IR) at four different blending levels. Modulation Transfer Function (MTF) curves, image noise, image contrast, noise power spectrum and contrast to noise ratio were assessed.ResultsIn-plane spatial resolution at the 10% of the MTF curve was 0.60 mm−1. In-plane spatial resolution was not modified with VMI energy and IR blending level. Image noise was reduced from 16.6 at 9 mGy to 6.7 at 32 mGy, while peak frequency remained within 0.14 ± 0.01 mm−1. Image noise was reduced from 14.3 at IR 10% to 11.5 at IR 50% at a constant peak frequency. The lowest image noise and maximum peak frequency were recorded at 70 keV.ConclusionsOur results have shown how objective image quality is varied when different levels of radiation dose and different settings in IR are applied. These results provide CT operators an in depth understanding of the imaging performance characteristics in dual energy CT.  相似文献   

16.

Purpose

To prospectively investigate the effect of using Gemstone Spectral Imaging (GSI) and adaptive statistical iterative reconstruction (ASIR) for reducing radiation and iodine contrast dose in abdominal CT patients with high BMI values.

Materials and Methods

26 patients (weight > 65kg and BMI ≥ 22) underwent abdominal CT using GSI mode with 300mgI/kg contrast material as study group (group A). Another 21 patients (weight ≤ 65kg and BMI ≥ 22) were scanned with a conventional 120 kVp tube voltage for noise index (NI) of 11 with 450mgI/kg contrast material as control group (group B). GSI images were reconstructed at 60keV with 50%ASIR and the conventional 120kVp images were reconstructed with FBP reconstruction. The CT values, standard deviation (SD), signal-noise-ratio (SNR), contrast-noise-ratio (CNR) of 26 landmarks were quantitatively measured and image quality qualitatively assessed using statistical analysis.

Results

As for the quantitative analysis, the difference of CNR between groups A and B was all significant except for the mesenteric vein. The SNR in group A was higher than B except the mesenteric artery and splenic artery. As for the qualitative analysis, all images had diagnostic quality and the agreement for image quality assessment between the reviewers was substantial (kappa = 0.684). CT dose index (CTDI) values for non-enhanced, arterial phase and portal phase in group A were decreased by 49.04%, 40.51% and 40.54% compared with group B (P = 0.000), respectively. The total dose and the injection rate for the contrast material were reduced by 14.40% and 14.95% in A compared with B.

Conclusion

The use of GSI and ASIR provides similar enhancement in vessels and image quality with reduced radiation dose and contrast dose, compared with the use of conventional scan protocol.  相似文献   

17.

Objective

To evaluate the clinical value of using monochromatic images in spectral CT pulmonary angiography to improve image quality of bronchial arteries.

Methods

We retrospectively analyzed the chest CT images of 38 patients who underwent contrast-enhanced spectral CT. These images included a set of 140kVp polychromatic images and the default 70keV monochromatic images. Using the standard Gemstone Spectral Imaging (GSI) viewer on an advanced workstation (AW4.6,GE Healthcare), an optimal energy level (in keV) for obtaining the best contrast-to-noise ratio (CNR) for the artery could be automatically obtained. The signal-to-noise ratio (SNR), CNR and objective image quality score (1–5) for these 3 image sets (140kVp, 70keV and optimal energy level) were obtained and, statistically compared. The image quality score consistency between the two observers was also evaluated using Kappa test.

Results

The optimal energy levels for obtaining the best CNR were 62.58±2.74keV.SNR and CNR from the 140kVp polychromatic, 70keV and optimal keV monochromatic images were (16.44±5.85, 13.24±5.52), (20.79±7.45, 16.69±6.27) and (24.9±9.91, 20.53±8.46), respectively. The corresponding subjective image quality scores were 1.97±0.82, 3.24±0.75, and 4.47±0.60. SNR, CNR and subjective scores had significant difference among groups (all p<0.001). The optimal keV monochromatic images were superior to the 70keV monochromatic and 140kVp polychromatic images, and there was high agreement between the two observers on image quality score (kappa>0.80).

Conclusions

Virtual monochromatic images at approximately 63keV in dual-energy spectral CT pulmonary angiography yielded the best CNR and highest diagnostic confidence for imaging bronchial arteries.  相似文献   

18.
PurposeTo assess the task-based performance of images obtained under different focal spot size and acquisition mode on a dual-energy CT scanner.MethodsAxial CT image series of the Catphan phantom were obtained using a tube focus at different sizes. Acquisitions were performed in standard single-energy, high resolution (HR) and dual-energy modes. Images were reconstructed using conventional and high definition (HD) kernels. Task-based transfer function at the 50% level (TTF50%) for teflon, delrin, low density polyethylene (LDPE) and acrylic, as well as image noise and noise texture, were assessed across all focal spots and acquisition modes using Noise Power Spectrum (NPS) analysis. A non-prewhitening mathematical observer model was used to calculate detectability index (dNPW).ResultsTTF50% degraded with increasing focal spot size. TTF50% ranged from 0.67 mm−1 for teflon to 0.25 mm−1 for acrylic. For standard kernel, image noise and NPS-determined average spatial frequency were 8.3 HU and 0.29 mm−1, respectively in single-energy, 12.0 HU and 0.37 mm−1 in HR, and 7.9 HU and 0.26 mm−1 in dual-energy mode. For standard kernel, dNPW was 61 in single-energy and HR mode and reduced to 56 in dual-energy mode.ConclusionsThe task-based image quality assessment metrics have shown that spatial resolution is higher for higher image contrast materials and detectability is higher in the standard single-energy mode compared to HR and dual-energy mode. The results of the current study provide CT operators the required knowledge to characterize their CT system towards the optimization of its clinical performance.  相似文献   

19.
PurposeThe purpose of this study was to develop a methodology to optimize computed radiographic techniques to image the skull, chest, and pelvis of a standard patient.MethodsOptimization was performed by varying exposure levels with different tube voltages to generate images of an anthropomorphic phantom. Image quality was evaluated using visual grading analysis and measuring objective parameters such as the effective detective quantum efficiency and the contrast-to-noise ratio. Objective and subjective evaluations were compared to obtain an optimized technique for each anatomic region.ResultsGold standard techniques provided a significant reduction in X-ray doses compared to the techniques used in our radiology service, without compromising diagnostic accuracy. They were chosen as follows 102 kVp/1.6 mAs for skull; 81 kVp/4.5 mAs for pelvis and 90 kVp/3.2 mAs for chest.ConclusionThere is a range of acceptable techniques that produce adequate images for diagnosis in computed radiography systems. This aspect allows the optimization process to be focused on the patient dose without compromising diagnostic capabilities. This process should be performed through association of quantitative and qualitative parameters, such as effective detective quantum efficiency, contrast-to-noise ratio, and visual grading analysis.  相似文献   

20.

Purpose

The purpose of this study was to evaluate image quality and status of lymph nodes in laryngeal and hypopharyngeal squamous cell carcinoma (SCC) patients using spectral CT imaging.

Materials and Methods

Thirty-eight patients with laryngeal and hypopharyngeal SCCs were scanned with spectral CT mode in venous phase. The conventional 140-kVp polychromatic images and one hundred and one sets of monochromatic images were generated ranging from 40 keV to 140 keV. The mean optimal keV was calculated on the monochromatic images. The image quality of the mean optimal keV monochromatic images and polychromatic images was compared with two different methods including a quantitative analysis method and a qualitative analysis method. The HU curve slope (λHU) in the target lymph nodes and the primary lesion was calculated respectively. The ratio of λHU was studied between metastatic and non-metastatic lymph nodes group.

Results

A total of 38 primary lesions were included. The mean optimal keV was obtained at 55±1.77 keV on the monochromatic images. The image quality evaluated by two different methods including a quantitative analysis method and a qualitative analysis method was obviously increased on monochromatic images than polychromatic images (p<0.05). The ratio of λHU between metastatic and non-metastatic lymph nodes was significantly different in the venous phase images (p<0.05).

Conclusion

The monochromatic images obtained with spectral CT can be used to improve the image quality of laryngeal and hypopharyngeal SCC and the N-staging accuracy. The quantitative ratio of λHU may be helpful for differentiating between metastatic and non-metastatic cervical lymph nodes.  相似文献   