首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Giardia lamblia is recognized as one of the most prevalent parasites in dogs. The present study aimed to establish a loop-mediated isothermal amplification (LAMP) assay for rapid and specific detection of G. lamblia from dogs. The fecal samples were collected and prepared for microscopic analysis, and then the genomic DNA was extracted directly from purified cysts. The concentration of DNA samples of G. lamblia were diluted by 10-fold serially ranging from 10-1 to 10-5 ng/µl for LAMP and PCR assays. The LAMP assay allows the amplification to be finished within 60 min under isothermal conditions of 63℃ by employing 6 oligonucleotide primers designed based on G. lamblia elongation factor 1 alpha (EF1α) gene sequence. Our tests showed that the specific amplification products were obtained only with G. lamblia, while no amplification products were detected with DNA of other related protozoans. Sensitivity evaluation indicated that the LAMP assay was sensitive 10 times more than PCR. It is concluded that LAMP is a rapid, highly sensitive and specific DNA amplification technique for detection of G. lamblia, which has implications for effective control and prevention of giardiasis.  相似文献   

2.
Aims: To develop a sensitive, rapid and simple method for detection of Botrytis cinerea based on loop‐mediated isothermal amplification (LAMP) that would be suitable for use outside a conventional laboratory setting. Methods and Results: A LAMP assay was designed based on the intergenic spacer of the B. cinerea nuclear ribosomal DNA (rDNA). The resulting assay was characterized in terms of sensitivity and specificity using DNA extracted from cultures. The assay consistently amplified 65 pg B. cinerea DNA. No cross‐reactivity was observed with a range of other fungal pathogens, with the exception of the closely related species Botrytis pelargonii. Use of a novel real‐time LAMP platform (the OptiGene Genie I) allowed detection of B. cinerea in infected rose petals, with amplification occurring in <15 min. Conclusions: The LAMP assay that was developed is suitable for rapid detection of B. cinerea in infected plant material. Significance and Impact of the Study: The LAMP method combines the sensitivity and specificity of nucleic acid‐based methods with simplified equipment and a reduced reaction time. These features make the method potentially suitable for on‐site use, where the results of testing could help to inform decisions regarding the storage and processing of commodities affected by B. cinerea, such as cut flowers, fruit and vegetables.  相似文献   

3.
A real-time immunoquantitative PCR (iqPCR) method for detection of Staphylococcus aureus enterotoxin B (SEB) was developed and evaluated using both pure cultures and foods. The assay consisted of immunocapture of SEB and real-time PCR amplification of the DNA probe linked to the detection antibody. iqPCR was compared to an in-house enzyme-linked immunosorbent assay (ELISA) using the same couple of capture-detection antibodies and to commercial kits for detection of S. aureus enterotoxins (SE). The iqPCR was approximately 1,000 times more sensitive (<10 pg ml−1) than the in-house ELISA and had a dynamic range of approximately 10 pg ml−1 to approximately 30,000 pg ml−1. iqPCR was not inhibited by any of the foods tested and was able to detect SEB present in these foods. No cross-reactivity with SE other than SEB was observed. Application of iqPCR for detection of SEB in cultures of S. aureus revealed the onset of SEB production after 4 h of incubation at 22, 37, and 42°C, which was in the first half of the exponential growth phase. The total amounts of SEB produced by the two strains tested were larger at 42°C than at 37°C and were strain dependent.  相似文献   

4.
Opisthorchis viverrini and other foodborne trematode infections are major health problem in Thailand, the Lao People's Democratic Republic, Vietnam and Cambodia. Differential diagnosis of O. viverrini based on the microscopic observation of parasite eggs is difficult in areas where Clonorchis sinensis and minute intestinal flukes coexist. We therefore established a rapid, sensitive and specific method for detecting O. viverrini infection from the stool samples using the loop-mediated isothermal amplification (LAMP) method. A total of five primers from seven regions were designed to target the internal transcribed spacer 1 (ITS1) in ribosomal DNA for specific amplification. Hydroxy naphthol blue (HNB) was more effective to detect the LAMP product compared to the Real-time LAMP and turbidity assay for its simple and distinct detection. The LAMP assay specifically amplified O. viverrini ITS1 but not C. sinensis and minute intestinal flukes with the limit of detection around 10− 3 ng DNA/μL. The sensitivity of the LAMP was 100% compared to egg positive samples. While all microscopically positive samples were positive by LAMP, additionally 5 of 13 (38.5%) microscopically negative samples were also LAMP positive. The technique has great potential for differential diagnosis in endemic areas with mixed O. viverrini and intestinal fluke infections. As it is an easy and simple method, the LAMP is potentially applicable for point-of-care diagnosis.  相似文献   

5.
Xanthomonas fragariae is a bacterium that causes angular leaf spot of strawberry. Asymptomatic infection is common and contributes to the difficulties in disease management. The aim of this study was to develop a loop-mediated isothermal amplification (LAMP) assay as an efficient method for detection of asymptomatic infections of X. fragariae. In addition, a new method of sample preparation was developed that allows sampling of a larger amount of plant tissue, hence increasing the detection rate in real-life samples. The sample preparation procedure includes an overnight incubation of strawberry tissues in phosphate-buffered saline (PBS), followed by a quick sample concentration and a boiling step to extract DNA for amplification. The detection limit of the LAMP assay was approximately 2×103 CFU/mL for pure bacteria culture and 300 CFU/mL for bacteria spiked strawberry leaf and petiole samples. LAMP provided a 2–3 fold lower detection limit than the standard qPCR assay but was faster, and more user-friendly. The LAMP assay should serve as a rapid, sensitive and cost-effective tool for detecting asymptomatic infections of X. fragariae in strawberry nursery stock and contribute to improved disease management.  相似文献   

6.
7.
In order to counter the common perception that molecular diagnostics are too complicated to work in low resource settings, we have performed a difficult sample preparation and DNA amplification protocol using instrumentation designed to be operated without wall or battery power. In this work we have combined a nearly electricity-free nucleic acid extraction process with an electricity-free isothermal amplification assay to detect the presence of Clostridium difficile (C. difficile) DNA in the stool of infected patients. We used helicase-dependent isothermal amplification (HDA) to amplify the DNA in a low-cost, thermoplastic reaction chip heated with a pair of commercially available toe warmers, while using a simple Styrofoam insulator. DNA was extracted from known positive and negative stool samples. The DNA extraction protocol utilized an air pressure driven solid phase extraction device run using a standard bicycle pump. The simple heater setup required no electricity or battery and was capable of maintaining the temperature at 65°C±2°C for 55 min, suitable for repeatable HDA amplification. Experiments were performed to explore the adaptability of the system for use in a range of ambient conditions. When compared to a traditional centrifuge extraction protocol and a laboratory thermocycler, this disposable, no power platform achieved approximately the same lower limit of detection (1.25×10−2 pg of C. difficile DNA) while requiring much less raw material and a fraction of the lab infrastructure and cost. This proof of concept study could greatly impact the accessibility of molecular assays for applications in global health.  相似文献   

8.
A loop-mediated isothermal amplification (LAMP) assay for rapid and sensitive detection of the L. ivanovii strains had been developed and evaluated in this study. Oligonucleotide primers specific for L. ivanovii species were designed corresponding to smcL gene sequences. The primers set comprise six primers targeting eight regions on the species-specific gene smcL. The LAMP assay could be completed within 1 h at 64°C in a water bath. Amplification products were directly observed by the Loopamp Fluorescent Detection Reagent (FD) or detected by agarose gel electrophoresis. Moreover, the LAMP reactions were also detected by real-time measurement of turbidity. The exclusivity of 77 non-L. ivanovii and the inclusivity of 17 L. ivanovii were both 100% in the assay. Sensitivity of the LAMP assay was 250 fg DNA and 16 CFU per reaction for detection of L. ivanovii in pure cultures and simulated human stool. The LAMP assay was 10 and 100-fold more sensitive than quantitative PCR (qPCR) and conventional PCR assays,respectively. When applied to human stool samples spiked with low level (8 CFU/0.5 g) of L. ivanovii strains, the new LAMP assay described here achieved positive detection after 6 hours enrichment. In conclusion, the new LAMP assay in this study can be used as a valuable, rapid and sensitive detection tool for the detection of L. ivanovii in field, medical and veterinary laboratories.  相似文献   

9.

Background

Carrion'' disease, caused by Bartonella bacilliformis, remains truly neglected due to its focal geographical nature. A wide spectrum of clinical manifestations, including asymptomatic bacteremia, and lack of a sensitive diagnostic test can potentially lead to a spread of the disease into non-endemic regions where competent sand fly vectors may be present. A reliable test capable of detecting B. bacilliformis is urgently needed. Our objective is to develop a loop-mediated isothermal amplification (LAMP) assay targeting the pap31 gene to detect B. bacilliformis.

Methods and Findings

The sensitivity of the LAMP was evaluated in comparison to qPCR using plasmid DNA containing the target gene and genomic DNA in the absence and presence of human or sand fly DNA. The detection limit of LAMP was 1 to 10 copies/µL, depending on the sample metrics. No cross-reaction was observed when testing against a panel of various closely related bacteria. The utility of the LAMP was further compared to qPCR by the examination of 74 Lutzomyia longipalpis sand flies artificially fed on blood spiked with B. bacilliformis and harvested at days (D) 1, 3, 5, 7 and 9 post feeding. Only 86% of sand flies at D1 and 63% of flies at D3 were positive by qPCR. LAMP was able to detect B. bacilliformis in all those flies confirmed positive by qPCR. However, none of the flies after D3 were positive by either LAMP or qPCR. In addition to demonstrating the sensitivity of the LAMP assay, these results suggest that B. bacilliformis cannot propagate in artificially fed L. longipalpis.

Conclusions

The LAMP assay is as sensitive as qPCR for the detection of B. bacilliformis and could be useful to support diagnosis of patients in low-resource settings and also to identify B. bacilliformis in the sand fly vector.  相似文献   

10.
Sustainable disease management depends on the ability to monitor the development of fungicide resistance in pathogen populations. A point mutation resulting in an alteration (F200Y) at codon 200 of the target protein β‐tubulin leads to a moderate level of resistance to carbendazim in Botrytis cinerea. Although traditional methods remain a cornerstone in detection of fungicide resistance, molecular methods that do not require the isolation of pathogens, can detect the presence of resistance alleles at low frequencies, and require less time and labour than traditional methods. In this study, we present an efficient, rapid, and highly specific method for detecting the moderately carbendazim‐resistant isolates in B. cinerea based on loop‐mediated isothermal amplification (LAMP). By using specific LAMP primers, we detected the resistance‐conferring mutation underlying β‐tubulin F200Y. The concentrations of LAMP components and LAMP parameters were optimised, resulting in reaction temperatures and times of 61–65°C and 45 min, respectively. The feasibility of the LAMP assay was verified by assaying the diseased samples with artificial inoculation in the different hosts. The LAMP assay developed in the current study was specific, stable, repeatable and sensitive, and was successfully applied for detection of moderately carbendazim‐resistant isolates of B. cinerea in plant samples.  相似文献   

11.
To investigate the effect of UV light on Cryptosporidium parvum and Cryptosporidium hominis oocysts in vitro, we exposed intact oocysts to 4-, 10-, 20-, and 40-mJ·cm−2 doses of UV irradiation. Thymine dimers were detected by immunofluorescence microscopy using a monoclonal antibody against cyclobutyl thymine dimers (anti-TDmAb). Dimer-specific fluorescence within sporozoite nuclei was confirmed by colocalization with the nuclear fluorogen 4′,6′-diamidino-2-phenylindole (DAPI). Oocyst walls were visualized using either commercial fluorescein isothiocyanate-labeled anti-Cryptosporidium oocyst antibodies (FITC-CmAb) or Texas Red-labeled anti-Cryptosporidium oocyst antibodies (TR-CmAb). The use of FITC-CmAb interfered with TD detection at doses below 40 mJ·cm−2. With the combination of anti-TDmAb, TR-CmAb, and DAPI, dimer-specific fluorescence was detected in sporozoite nuclei within oocysts exposed to 10 to 40 mJ·cm−2 of UV light. Similar results were obtained with C. hominis. C. parvum oocysts exposed to 10 to 40 mJ·cm−2 of UV light failed to infect neonatal mice, confirming that results of our anti-TD immunofluorescence assay paralleled the outcomes of our neonatal mouse infectivity assay. These results suggest that our immunofluorescence assay is suitable for detecting DNA damage in C. parvum and C. hominis oocysts induced following exposure to UV light.  相似文献   

12.
The marine bacterium Vibrio parahaemolyticus (V. parahaemolyticus) causes gastroenteritis in humans via the ingestion of raw or undercooked contaminated seafood, and early diagnosis and prompt treatment are important for the prevention of V. parahaemolyticus-related diseases. In this study, a real-time resistance measurement based on loop-mediated isothermal amplification (LAMP), electrochemical ion bonding (Crystal violet and Mg2+), real-time monitoring, and derivative analysis was developed. V. parahaemolyticus DNA was first amplified by LAMP, and the products (DNA and pyrophosphate) represented two types of negative ions that could combine with a positive dye (Crystal violet) and positive ions (Mg2+) to increase the resistance of the reaction liquid. This resistance was measured in real-time using a specially designed resistance electrode, thus permitting the quantitative detection of V. parahaemolyticus. The results were obtained in 1–2 hours, with a minimum bacterial density of 10 CFU.mL−1 and high levels of accuracy (97%), sensitivity (96.08%), and specificity (97.96%) when compared to cultivation methods. Therefore, this simple and rapid method has a potential application in the detection of V. parahaemolyticus on a gene chip or in point-of-care testing.  相似文献   

13.
An estrogen-inducible bacterial lux-based bioluminescent reporter was developed in Saccharomyces cerevisiae for applications in chemical sensing and environmental assessment of estrogen disruptor activity. The strain, designated S. cerevisiae BLYES, was constructed by inserting tandem estrogen response elements between divergent yeast promoters GPD and ADH1 on pUTK401 (formerly pUA12B7) that constitutively express luxA and luxB to create pUTK407. Cotransformation of this plasmid with a second plasmid (pUTK404) containing the genes required for aldehyde synthesis (luxCDE) and FMN reduction (frp) yielded a bioluminescent bioreporter responsive to estrogen-disrupting compounds. For validation purposes, results with strain BLYES were compared to the colorimetric-based estrogenic assay that uses the yeast lacZ reporter strain (YES). Strains BLYES and YES were exposed to 17β-estradiol over the concentration range of 1.2 × 10−8 through 5.6 × 10−12 M. Calculated 50% effective concentration values from the colorimetric and bioluminescence assays (n = 7) were similar at (4.4 ± 1.1) × 10−10 and (2.4 ± 1.0) × 10−10 M, respectively. The lower and upper limits of detection for each assay were also similar and were approximately 4.5 × 10−11 to 2.8 × 10−9 M. Bioluminescence was observed in as little as 1 h and reached its maximum in 6 h. In comparison, the YES assay required a minimum of 3 days for results. Strain BLYES fills the niche for rapid, high-throughput screening of estrogenic compounds and has the ability to be used for remote, near-real-time monitoring of estrogen-disrupting chemicals in the environment.  相似文献   

14.
We report a novel electrochemical immunosensor that can sensitively detect avian influenza virus H5 subtype (AIV H5) captured by graphene oxide-H5-polychonal antibodies-bovine serum albumin (GO-PAb-BSA) nanocomposite. The graphene oxide (GO) carried H5-polychonal antibody (PAb) were used as signal amplification materials. Upon signal amplification, the immunosensor showed a 256-fold increase in detection sensitivity compared to the immunosensor without GO-PAb-BSA. We designed a PAb labeling GO strategy and signal amplification procedure that allow ultrasensitive and selective detection of AIV H5. The established method responded to 2−15 HA unit/50 µL H5, with a linear calibration range from 2−15 to 2−8 HA unit/50 µL. In summary, we demonstrated that the immunosenser has a high specificity and sensitivity for AIV H5, and the established assay could be potentially applied in the rapid detection of other pathogenic microorganisms.  相似文献   

15.
In this study, a sensitive dual-label time-resolved reverse competitive chemiluminescent immunoassay was developed for simultaneous detection of chloramphenicol (CAP) and clenbuterol (CLE) in milk. The strategy was performed based on the distinction of the kinetic characteristics of horseradish peroxidase (HRP) and alkaline phosphatase (ALP) in chemiluminesecence (CL) systems and different orders of magnitude in HRP CL value for CAP and ALP CL value for CLE in the chemiluminescent immunoassay. Capture antibodies were covalently bound to the amine group functionalized chemiluminescent microtiter plate (MTP) for efficient binding of detection antibodies for the enzymes labeled CAP (HRP-CAP) and CLE (ALP-CLE). The CL signals were recorded at different time points by the automatic luminometers with significant distinction in the dynamic curves. When we considered the ALP CL value (about 105) of CLE as background for HRP CL signal value (about 107) of CAP, there was no interaction from ALP CL background of CLE and the differentiation of CAP and CLE can be easily achieved. The 50% inhibition concentration (IC50) values of CAP and CLE in milk samples were 0.00501 µg L−1 and 0.0128 µg L−1, with the ranges from 0.0003 µg L−1 to 0.0912 µg L−1 and from 0.00385 µg L−1 to 0.125 µg L−1, respectively. The developed method is more sensitive and of less duration than the commercial ELISA kits, suitable for simultaneous screening of CAP and CLE.  相似文献   

16.

Background

Buruli ulcer (BU) caused by Mycobacterium ulcerans (M. ulcerans) has emerged as an important public health problem in several rural communities in sub-Saharan Africa. Early diagnosis and prompt treatment are important in preventing disfiguring complications associated with late stages of the disease progression. Presently there is no simple and rapid test that is appropriate for early diagnosis and use in the low-resource settings where M. ulcerans is most prevalent.

Methodology

We compared conventional and pocket warmer loop mediated isothermal amplification (LAMP) methods (using a heat block and a pocket warmer respectively as heat source for amplification reaction) for the detection of M. ulcerans in clinical specimens. The effect of purified and crude DNA preparations on the detection rate of the LAMP assays were also investigated and compared with that of IS2404 PCR, a reference assay for the detection of M. ulcerans. Thirty clinical specimens from suspected BU cases were examined by LAMP and IS2404 PCR.

Principal Findings

The lower detection limit of both LAMP methods at 60°C was 300 copies of IS2404 and 30 copies of IS2404 for the conventional LAMP at 65°C. When purified DNA extracts were used, both the conventional LAMP and IS2404 PCR concordantly detected 21 positive cases, while the pocket warmer LAMP detected 19 cases. Nine of 30 samples were positive by both the LAMP assays as well as IS2404 PCR when crude extracts of clinical specimens were used.

Conclusion/Significance

The LAMP method can be used as a simple and rapid test for the detection of M. ulcerans in clinical specimens. However, obtaining purified DNA, as well as generating isothermal conditions, remains a major challenge for the use of the LAMP method under field conditions. With further improvement in DNA extraction and amplification conditions, the pwLAMP could be used as a point of care diagnostic test for BU  相似文献   

17.
Shiga toxin-producing Escherichia coli (STEC) strains are a leading cause of produce-associated outbreaks in the United States. Rapid, reliable, and robust detection methods are needed to better ensure produce safety. We recently developed a loop-mediated isothermal amplification (LAMP) suite for STEC detection. In this study, the STEC LAMP suite was comprehensively evaluated against real-time quantitative PCR (qPCR) using a large panel of bacterial strains (n = 156) and various produce items (several varieties of lettuce, spinach, and sprouts). To simulate real-world contamination events, produce samples were surface inoculated with a low level (1.2 to 1.8 CFU/25 g) of individual STEC strains belonging to seven serogroups (O26, O45, O103, O111, O121, O145, and O157) and held at 4°C for 48 h before testing. Six DNA extraction methods were also compared using produce enrichment broths. All STEC targets and their subtypes were accurately detected by the LAMP suite. The detection limits were 1 to 20 cells per reaction in pure culture and 105 to 106 CFU per 25 g (i.e., 103 to 104 CFU per g) in produce, except for strains harboring the stx2c, eae-β, and eae-θ subtypes. After 6 to 8 h of enrichment, the LAMP suite achieved accurate detection of low levels of STEC strains of various stx2 and eae subtypes in lettuce and spinach varieties but not in sprouts. A similar trend of detection was observed for qPCR. The PrepMan Ultra sample preparation reagent yielded the best results among the six DNA extraction methods. This research provided a rapid, reliable, and robust method for detecting STEC in produce during routine sampling and testing. The challenge with sprouts detection by both LAMP and qPCR calls for special attention to further analysis.  相似文献   

18.
To provide a basis for using indigenous bacteria for bioremediation of heavy metal contaminated soil, the heavy metal resistance and plant growth-promoting activity of 136 isolates from V-Ti magnetite mine tailing soil were systematically analyzed. Among the 13 identified bacterial genera, the most abundant genus was Bacillus (79 isolates) out of which 32 represented B. subtilis and 14 B. pumilus, followed by Rhizobium sp. (29 isolates) and Ochrobactrum intermedium (13 isolates). Altogether 93 isolates tolerated the highest concentration (1000 mg kg−1) of at least one of the six tested heavy metals. Five strains were tolerant against all the tested heavy metals, 71 strains tolerated 1,000 mg kg−1 cadmium whereas only one strain tolerated 1,000 mg kg−1 cobalt. Altogether 67% of the bacteria produced indoleacetic acid (IAA), a plant growth-promoting phytohormone. The concentration of IAA produced by 53 isolates was higher than 20 µg ml−1. In total 21% of the bacteria produced siderophore (5.50–167.67 µg ml−1) with two Bacillus sp. producing more than 100 µg ml−1. Eighteen isolates produced both IAA and siderophore. The results suggested that the indigenous bacteria in the soil have beneficial characteristics for remediating the contaminated mine tailing soil.  相似文献   

19.
This paper describes a quantitative and sensitive chemical assay for cereulide, the heat-stable emetic toxin produced by Bacillus cereus. The methods previously available for measuring cereulide are bioassays that give a toxicity titer, but not an accurate concentration. The dose of cereulide causing illness in humans is therefore not known, and thus safety limits for cereulide cannot be indicated. We developed a quantitative and sensitive chemical assay for cereulide based on high-performance liquid chromatography (HPLC) connected to ion trap mass spectrometry. This chemical assay and a bioassay based on boar sperm motility inhibition were calibrated with purified cereulide and with valinomycin, a structurally similar cyclic depsipeptide. The boar spermatozoan motility assay and chemical assay gave uniform results over a wide range of cereulide concentrations, ranging from 0.02 to 230 μg ml−1. The detection limit for cereulide and valinomycin by HPLC-mass spectrometry was 10 pg per injection. The combined chemical and biological assays were used to define conditions and concentrations of cereulide formation by B. cereus strains F4810/72, NC7401, and F5881. Cereulide production commenced at the end of logarithmic growth, but was independent of sporulation. Production of cereulide was enhanced by incubation with shaking compared to static conditions. The three emetic B. cereus strains accumulated 80 to 166 μg of cereulide g−1 (wet weight) when grown on solid medium. Strain NC7401 accumulated up to 25 μg of cereulide ml−1 in liquid medium at room temperature (21 ± 1°C) in 1 to 3 days, during the stationary growth phase when cell density was 2 × 108 to 6 × 108 CFU ml−1. Cereulide production at temperatures at and below 8°C or at 40°C was minimal.  相似文献   

20.
We designed a real-time PCR assay able to recognize dioxygenase large-subunit gene sequences with more than 90% similarity to the Ralstonia sp. strain U2 nagAc gene (nagAc-like gene sequences) in order to study the importance of organisms carrying these genes in the biodegradation of naphthalene. Sequencing of PCR products indicated that this real-time PCR assay was specific and able to detect a variety of nagAc-like gene sequences. One to 100 ng of contaminated-sediment total DNA in 25-μl reaction mixtures produced an amplification efficiency of 0.97 without evident PCR inhibition. The assay was applied to surficial freshwater sediment samples obtained in or in close proximity to a coal tar-contaminated Superfund site. Naphthalene concentrations in the analyzed samples varied between 0.18 and 106 mg/kg of dry weight sediment. The assay for nagAc-like sequences indicated the presence of (4.1 ± 0.7) × 103 to (2.9 ± 0.3) × 105 copies of nagAc-like dioxygenase genes per μg of DNA extracted from sediment samples. These values corresponded to (1.2 ± 0.6) × 105 to (5.4 ± 0.4) × 107 copies of this target per g of dry weight sediment when losses of DNA during extraction were taken into account. There was a positive correlation between naphthalene concentrations and nagAc-like gene copies per microgram of DNA (r = 0.89) and per gram of dry weight sediment (r = 0.77). These results provide evidence of the ecological significance of organisms carrying nagAc-like genes in the biodegradation of naphthalene.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号