首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Here, we reported the development of a label-free and real-time surface plasmon resonance (SPR) based biosensor for cancer stem cells (CSCs) detection using cell surface biomarker; CD133. The fabricated biosensor was used for detection of this marker in some acute myeloid leukemia (AML) patients and the results were compared with those obtained from flow cytometry (FC) method. CD133 antibody was immobilized on the gold chip surface via EDC/NHS coupling method and binding of the candidate cells to the modified gold sensor surface was monitored after isolation of mononuclear cells from bone marrow of the patients. The method was validated in terms of various parameters such as CD133- antibody concentration and cell density. The CD133-marked cells were investigated in seven AML patients. All SPR results were compared with those obtained from FC method. A very good correlation (R2 = 0.96) was obtained between SPR and FC responses related to CD133-marked cells densities. In conclusion, in this study, a label-free and real-time SPR cytometry method was developed to detect CD133 and it was successfully applied to follow this cancer stem cell biomarker in AML patients.  相似文献   

2.
To facilitate biosensor studies of G-protein coupled receptors (GPCR) and other membrane proteins, reliable methods for preparation of sensor surfaces with high protein density are required. We present here a method for the easy and rapid immobilization and reconstitution of GPCR on carboxylated dextran surfaces modified with long alkyl groups. Following amine coupling of the detergent-solubilized receptor, lipid/detergent-mixed micelles were adhered as they were injected over the immobilized surface, taking advantage of the integrated flow cells. The detergent was eluted in the subsequent buffer flow and the remaining lipid formed a bilayer on the chip surface. With this procedure, rhodopsin was functionally reconstituted in a lipid environment in approximately 1 min. This method can also be used for the easy formation of pure supported lipid bilayers for use in model membrane interaction studies.  相似文献   

3.
The BARC biosensor applied to the detection of biological warfare agents   总被引:10,自引:0,他引:10  
The Bead ARray Counter (BARC) is a multi-analyte biosensor that uses DNA hybridization, magnetic microbeads, and giant magnetoresistive (GMR) sensors to detect and identify biological warfare agents. The current prototype is a table-top instrument consisting of a microfabricated chip (solid substrate) with an array of GMR sensors, a chip carrier board with electronics for lock-in detection, a fluidics cell and cartridge, and an electromagnet. DNA probes are patterned onto the solid substrate chip directly above the GMR sensors, and sample analyte containing complementary DNA hybridizes with the probes on the surface. Labeled, micron-sized magnetic beads are then injected that specifically bind to the sample DNA. A magnetic field is applied, removing any beads that are not specifically bound to the surface. The beads remaining on the surface are detected by the GMR sensors, and the intensity and location of the signal indicate the concentration and identity of pathogens present in the sample. The current BARC chip contains a 64-element sensor array, however, with recent advances in magnetoresistive technology, chips with millions of these GMR sensors will soon be commercially available, allowing simultaneous detection of thousands of analytes. Because each GMR sensor is capable of detecting a single magnetic bead, in theory, the BARC biosensor should be able to detect the presence of a single analyte molecule.  相似文献   

4.
Biomolecular interaction analysis mass spectrometry (BIA/MS) is a multiplexed analytical technique that utilizes a unique combination of surface plasmon resonance (SPR) and matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) for the detection and analysis of small amounts of proteins residing in complex biological systems. In order to achieve high sensitivity during BIA/MS, certain experimental parameters and sequences of events need to be optimized and maintained. Immobilized ligand density, flow rate and biosensor control (in SPR-BIA) and matrix choice and application (in MALDI-TOF MS) have significant influence on the final outcome of the BIA/MS analysis and, consequently, need to be optimized and carefully controlled. In addition, chip washing and cutting are essential in converting the SPR-active sensor chips into target surfaces amenable to MALDI-TOF MS. Reviewed here are the prerequisites for successfully interfacing SPR-BIA with MALDI-TOF MS.  相似文献   

5.
The growth factor receptor-binding protein 2-Src homology 2 (Grb2-SH2) domain plays an important role in the oncogenic Ras signal transduction pathway, therefore, peptidic inhibitors of the Grb2-SH2 domain has been chosen as our target for the development of antiproliferative agents. The inhibitory effects of peptide analogs on the Grb2-SH2 domain have been determined by using surface plasmon resonance (SPR) technology developed with the BIACORE biosensor. Recently, we reported the analysis of interactions between peptides and the GST-Grb2-SH2 that was immobilized on the surface of sensor chip by using BIACORE biosensor (the protein-immobilized method). Herein, we analyze interactions of peptides with the GST-Grb2-SH2 that was captured by the anti-GST antibodies immobilized on the surface of sensor chip (the protein-captured method). Results obtained by both methods are in good correlation, indicating the immobilization of GST-Grb2-SH2 on the sensor chip did not significantly affect the binding of Grb2-SH2 with peptides. Both SPR-based assays are very sensitive bioanalytical methods and can be applied in screening inhibitors of target proteins or purifying GST-fusion proteins, however, considering the efficiency and the cost, the GST-Grb2-SH2-immobilized method is suggested for routinely determining the binding potency of inhibitors of Grb2-SH2.  相似文献   

6.
Multiple phage-based magnetoelastic (ME) biosensors were simultaneously monitored for the detection of different biological pathogens that were sequentially introduced to the measurement system. The biosensors were formed by immobilizing phage and 1mg/ml BSA (blocking agent) onto the magnetoelastic resonator's surface. The detection system included a reference sensor as a control, an E2 phage-coated sensor specific to S. typhimurium, and a JRB7 phage-coated sensor specific to B. anthracis spores. The sensors were free standing during the test, being held in place by a magnetic field. Upon sequential exposure to single pathogenic solutions, only the biosensor coated with the corresponding specific phage responded. As the cells/spores were captured by the specific phage-coated sensor, the mass of the sensor increased, resulting in a decrease in the sensor's resonance frequency. Additionally, non-specific binding was effectively eliminated by BSA blocking and was verified by the reference sensor, which showed no frequency shift. Scanning electron microscopy was used to visually verify the interaction of each biosensor with its target analyte. The results demonstrate that multiple magnetoelastic sensors may be simultaneously monitored to detect specifically targeted pathogenic species with good selectivity. This research is the first stage of an ongoing effort to simultaneously detect the presence of multiple pathogens in a complex analyte.  相似文献   

7.
Hasegawa K  Ono K  Yamada M  Naiki H 《Biochemistry》2002,41(46):13489-13498
To establish the kinetic model of the extension and dissociation of beta-amyloid fibrils (f(A)beta) in vitro, we analyzed these reactions using a surface plasmon resonance (SPR) biosensor. Sonicated f(A)beta were immobilized on the surface of the SPR sensor chip as seeds. The SPR signal increased linearly as a function of time after amyloid beta-peptides (Abeta) were injected into the f(A)beta-immobilized chips. The extension of f(A)beta was confirmed by atomic force microscopy. When flow cells were washed with running buffer, the SPR signal decreased with time after the extension reaction. The curve fitting resolved the dissociation reaction into the fast exponential and slow linear decay phases. Kinetic analysis of the effect of Abeta/f(A)beta concentrations on the reaction rate indicated that both the extension reaction and the slow linear phase of the dissociation were consistent with a first-order kinetic model; i.e., the extension/dissociation reactions proceed via consecutive association/dissociation of Abeta onto/from the end of existing fibrils. On the basis of this model, the critical monomer concentration ([M](e)) and the equilibrium association constant (K) were calculated, for the first time, to be 20 nM and 5 x 10(7) M(-1), respectively. Alternatively, [M](e) was directly measured as 200 nM, which may represent the equilibrium between the extension reaction and the fast phase of the dissociation. The SPR biosensor is a useful quantitative tool for the kinetic and thermodynamic study of the molecular mechanisms of f9A)beta formation in vitro.  相似文献   

8.
A novel sensor chip for use in surface plasmon resonance (SPR) biosensors has been developed to capture vesicles which may contain membrane-bound receptors. Sulforhodamine-containing vesicles were shown by fluorescence microscopy to be immobilized intact on the sensor chip. Binding of cholera toxin to captured vesicles containing ganglioside GM(1) was demonstrated using SPR, and the derived kinetic and affinity constants were similar to literature values. Biotinylated vesicles captured on the sensor chip were used to bind streptavidin and then biotinylated ss-DNA. The hybridization of complementary ss-DNA to the immobilized ss-DNA was then analyzed using SPR. The values obtained were similar to those obtained for an identical interaction analyzed using a commercially available streptavidin-containing sensor chip. Binding of vancomycin-group antibiotics to captured vesicles containing a bacterial cell wall mucopeptide analogue was demonstrated. No binding of the bacterial endotoxin Cry1A(c) to captured vesicles containing its cell surface receptor could be demonstrated.  相似文献   

9.
A biosensor based on mammalian metallothionein (MT) for the detection of metal ions was developed and characterized. MT was immobilized onto a carboxymethylated dextran matrix as a biosensor for the detection of metal ions by surface plasmon resonance (SPR). The optimal pH for the immobilization step was determined to be 4. The temperature for the analysis was also defined, and the highest interaction was observed at 30 degrees C. The MT sensor chip binds cadmium (Cd), zinc (Zn) or nickel (Ni), but not magnesium (Mg), manganese (Mn) and calcium (Ca). Calibration curves for the quantification of metal ions showed excellent linearity. The sensitivity for metal detection is at the micromolar level. The interaction between the metal ions and the sensor chip is influenced significantly by the presence of NaCl, Tween 20 and the pH of the reaction buffer. By decreasing the NaCl in the reaction buffer to 1 mM, the MT chip effectively differentiates cadmium from zinc and nickel. Kinetic parameters of the metal-MT interactions were also determined by using this chip. The binding affinity between the metal ions and the immobilized MT follows the order of cadmium > zinc > nickel, which is the same as that determined for MT in solution. Thus, the MT chip can be an effective biosensor for the detection and measurement of several metal ions.  相似文献   

10.
寻找与SARS-CoV核蛋白相互作用的宿主细胞蛋白,从而探索SARS-CoV的致病机理。可溶性表达SARS-CoV核蛋白,利用His标签和离子交换层析对表达的蛋白进行了纯化,获得较纯的可溶性核蛋白。再将SPR/BIA技术与MALDI-TOF MS技术结合起来,使用SPR生物传感芯片作为亲和吸附的表面,分别捕获2BS细胞和A549细胞裂解液中与SARS-CoV核蛋白相互作用的细胞蛋白,收集足够量的相互作用蛋白,再利用MALDI-TOF-MS分析获得蛋白的性质。结果鉴定出与SARS-CoV核蛋白相互作用的蛋白:26S蛋白酶调节亚单位S10B(蛋白酶体亚单位p42)(蛋白酶体26S亚单位ATPase 6)(P62333),属于泛素/蛋白酶体系统;目前国内外尚未见类似报道。此研究初步发现了一种与SARS-CoV核蛋白在细胞外相互作用的蛋白,但这种相互作用在SARS-CoV感染及SARS的发生发展中发挥的作用还有待于深入研究和探索。  相似文献   

11.
A surface plasmon resonance (SPR)-immunosensor for detection of benzo[a]pyrene (BaP) is developed by using a model BaP-hapten compound, BaP-bovine serum albumin conjugate (BaP-BSA), and an anti-BaP-BSA monoclonal antibody. BaP-BSA conjugate is immobilized on a gold thin-film sensor chip by means of simple physical adsorption. The number of BaP-hapten units in BaP-BSA conjugate is estimated to be 28 from the difference in molecular weight (MW) between BaP-BSA conjugate and BSA based on the results of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) measurement. Anti-BaP-BSA antibody on contact with the BaP-BSA conjugate immobilized sensor chip causes an increase in the incident angle of the sensor chip. Binding of anti-BaP-BSA antibody with surface-immobilized BaP-BSA conjugate is inhibited by the presence of BaP in analyte solution, because of the inhibition effect of BaP. The SPR immunosensor for BaP functioning with the indirect competitive immunoreaction of anti-BaP-BSA antibody between the analyte (BaP) in testing solution and the BaP-BSA conjugate immobilized on the sensor chip provides a rapid determination (response time: ca. 15 min) of BaP in the concentration range of 0.01-1000 ppb. The antibody anchored to the sensor chip by antigen-antibody binding is removed on treatment with a pepsin solution (pH 2.0) for few minutes. The SPR sensor chip is found to be reusable for more than 20 times with a little decrease (<7%) in the sensor response. Detection of BaP by direct competitive immunoreactions is also carried out by enzyme-linked immunosorbent assay (ELISA). The concentration of BaP could be determined as low as 0.01 ppb and 2 ppb using the SPR sensor and the ELISA method, respectively. The SPR sensor is found to detect BaP selectively in the presence of 2-hydroxybiphenyl (HBP); the incident angle shift of the SPR sensor for BaP is found to be same irrespective to the presence or the absence of a same concentration (as much as 30 ppb) of HBP together.  相似文献   

12.
The determination of bile acid concentration in urine is useful for the screening and diagnosis of various hepatobiliary diseases. Currently, there is no concise method to determine bile acid concentration in urine. This study describes a bile acid biosensor fabricated by electrochemical technique for urinalysis. The micro-planar electrodes employed for the study consisted of a working electrode (platinum), a counter electrode (platinum) and a reference electrode (silver/silver chloride (Ag/AgCl)). The sensor chip was coated with Nafion using a spin-coater in order to both eliminate many interference species in urine and achieve long-term stability of the reference electrode. Nafion coating allowed the sensor chip to prevent the electrode reaction from interference species in urine, because it is charged negative strongly (Nafion contains sulfonic acid group). Three enzymes (bile acid sulfate sulfatase: BSS, beta-hydroxysteroid dehydrogenase: beta-HSD, and NADH oxidase: NHO) were immobilized by glutaraldehyde (GA: cross-linker) onto the sensor chip, because the immobilization of enzymes by GA is simple and commonly carried out. The sensor chip was able to detect bile acid in buffer solution. The optimum enzyme ratio immobilized onto the sensor chip was BSS:beta-HSD:NHO=4:4:20 U/1 chip. There was a relationship between the concentration of bile acid and the response current value. The dynamic range of the sensor chip was 2-100 microM for bile acid. Additionally, bile acid in the urine specimen could be detected using this bile acid biosensor. We present a simple and rapid bile acid biosensor with high sensitivity and high reproducibility.  相似文献   

13.
Surface plasmon resonance imaging (SPRi) has emerged as a versatile biosensor to detect a wide range of biomolecular interactions with divergent potential applications. However, the use of this advanced-level technology for stem cell lysate study is still not much explored. Cell lysates are significant biological analytes used for disease diagnostics and proteomic studies, but their complex nature limits their use as an analyte for SPRi biosensors. Here, we review the problems associated with the use of SPRi for stem cell lysate study and examine the role of surface chemistry, running buffer, and blocking solution in order to minimize nonspecific adsorption (NSA). We detect the expression of Oct4, Sox2, Nanog, Rex1, and Lin28 biomarkers present in mouse embryonic stem cell (mESC) lysate against their corresponding antibodies immobilized on the sensor surface with reduced NSA. The current study shows that the conjunction of SPRi and microarray can be used as a label-free, high-throughput, and rapid technique for detection of biomarkers and their relative abundance in stem cell lysate study.  相似文献   

14.
We enhanced the sensitivity of surface plasmon resonance biosensor by the conversion of the real-time direct binding immunoassay into the sandwich immunoassay, in which colloidal gold particles coated with anti-mouse IgG was used. By the immobilization of anti-mouse IgG onto the carboxymethyl dextran surface of thin gold film, the direct binding of analyte (mouse IgG) onto the sensor chip, and the injection of colloidal gold particles coated with antimouse IgG, about 100 times of sensitivity enhancement was obtained. This result suggests that nanoparticles, which has a high refractive index, homogeneous ultrafine structure and capability of size control, would be applicable for the detection of very small quantity of biomaterial.  相似文献   

15.
The interaction between S-layer protein SbsB and the secondary cell wall polymer (SCWP) of Geobacillus stearothermophilus PV72/p2 was investigated by real-time surface plasmon resonance biosensor technology. The SCWP is an acidic polysaccharide that contains N-acetylglucosamine, N-acetylmannosamine, and pyruvic acid. For interaction studies, recombinant SbsB (rSbsB) and two truncated forms consisting of either the S-layer-like homology (SLH) domain (3SLH) or the residual part of SbsB were used. Independent of the setup, the data showed that the SLH domain was exclusively responsible for SCWP binding. The interaction was found to be highly specific, since neither the peptidoglycan nor SCWPs from other organisms nor other polysaccharides were recognized. Data analysis from that setup in which 3SLH was immobilized on a sensor chip and SCWP represented the soluble analyte was done in accordance with a model that describes binding of a bivalent analyte to a fixed ligand in terms of an overall affinity for all binding sites. The measured data revealed the presence of at least two binding sites on a single SCWP molecule with a distance of about 14 nm and an overall Kd of 7.7 x 10(-7) M. Analysis of data from the inverted setup in which the SCWP was immobilized on a sensor chip was done in accordance with an extension of the heterogeneous-ligand model, which indicated the existence of three binding sites with low (Kd = 2.6 x 10(-5) M), medium (Kd = 6.1 x 10(-8) M), and high (Kd = 6.7 x 10(-11) M) affinities. Since in this setup 3SLH was the soluble analyte and the presence of small amounts of oligomers in even monomeric protein solutions cannot be excluded, the high-affinity binding site may result from avidity effects caused by binding of at least dimeric 3SLH. Solution competition assays performed with both setups confirmed the specificity of the protein-carbohydrate interaction investigated.  相似文献   

16.
A fractal analysis is presented for the binding and dissociation of different heart-related compounds in solution to receptors immobilized on biosensor surfaces. The data analyzed include LCAT (lecithin cholesterol acyl transferase) concentrations in solution to egg white apoA-I rHDL immobilized on a biosensor chip surface (1), native, mildly oxidized, and strongly oxidized LDL in solution to a heparin-modified Au-surface of a surface plasmon resonance (SPR) biosensor (2), and TRITC-labeled HDL in solution to a bare optical fiber surface (3). Single-and dual-fractal models were used to fit the data. Values of the binding and the dissociation rate coefficient(s), affinity values, and the fractal dimensions were obtained from the regression analysis provided by Corel Quattro Pro 8.0 (4). The binding rate coefficients are quite sensitive to the degree of heterogeneity on the sensor chip surface. Predictive equations are developed for the binding rate coefficient as a function of the degree of heterogeneity present on the sensor chip surface and on the LCAT concentration in solution and for the affinity as a function of the ratio of fractal dimensions present in the binding and the dissociation phases. The analysis presented provided physical insights into these analyte-receptor reactions occurring on different biosensor surfaces.  相似文献   

17.
Affinity-based analyses on biosensors depend partly on regeneration between measurements. Regeneration is performed with a buffer that efficiently breaks all interactions between ligand and analyte while maintaining the active binding site of the ligand. We demonstrated a regeneration buffer scouting using the combination of a continuous flow microspotter with a surface plasmon resonance imaging platform to simultaneously test 48 different regeneration buffers on a single biosensor. Optimal regeneration conditions are found within hours and consume little amounts of buffers, analyte, and ligand. This workflow can be applied to any ligand that is coupled through amine, thiol, or streptavidin immobilization.  相似文献   

18.
A method has been developed for measurement of antibody affinity and cross-reactivity by surface plasmon resonance spectroscopy using the EK-coil heterodimeric coiled-coil peptide capture system. This system allows for reversible capture of synthetic peptide ligands on a biosensor chip surface, with the advantage that multiple antibody-antigen interactions can be analyzed using a single biosensor chip. This method has proven useful in the development of a synthetic peptide anti-Pseudomonas aeruginosa (PA) vaccine. Synthetic peptide ligands corresponding to the receptor binding domains of pilin from four strains of PA were conjugated to the E-coil strand of the heterodimeric coiled-coil domain and individually captured on the biosensor chip through dimerization with the immobilized K-coil strand. Polyclonal rabbit IgG raised against pilin epitopes was injected over the sensor chip surface for kinetic analysis of the antigen-antibody interaction. The kinetic rate constants, k(on) and k(off), and equilibrium association and dissociation constants, KA and KD, were calculated. Antibody affinities ranged from 1.14 x 10(-9) to 1.60 x 10(-5) M. The results suggest that the carrier protein and adjuvant used during immunization make a dramatic difference in antibody affinity and cross-reactivity. Antibodies raised against the PA strain K pilin epitope conjugated to keyhole limpet haemocyanin using Freund's adjuvant system were more broadly cross-reactive than antibodies raised against the same epitope conjugated to tetanus toxoid using Adjuvax adjuvant. The method described here is useful for detailed characterization of the interaction of polyclonal antibodies with a panel of synthetic peptide ligands with the objective of obtaining high affinity and cross-reactive antibodies in vaccine development.  相似文献   

19.
Xu G  Ye X  Qin L  Xu Y  Li Y  Li R  Wang P 《Biosensors & bioelectronics》2005,20(9):1757-1763
Cell-based biosensors incorporate cells as sensing elements that convert changes in immediate environment to signals for processing. This paper reports an investigation on light-addressable potentiometric sensor (LAPS) to be used as a possible cell-base biosensor that will enable us to monitor extracellular action potential of single living cell under stimulant. In order to modify chip surface and immobilize cells, we coat a layer of poly-L-ornithine and laminin on surface of LAPS chip on which rat cortical cells are grown well. When 10 microg/ml acetylcholine solution is administrated, the light pointer is focused on a single neuronal cell and the extracellular action potential of the targeted cell is recorded with cell-based biosensor based on LAPS. The results demonstrate that this kind of biosensor has potential to monitor electrophysiology of living cell non-invasive for a long term, and to evaluate drugs primarily.  相似文献   

20.
Grating-coupled surface plasmon resonance imaging (GCSPRI) is a method for the accurate assessment of both cell phenotype and function. In GCSPRI, cells and/or proteins of interest are flowed across antibodies immobilized on a gold-coated sensor chip. The surface of the chip is illuminated with monochromatic light that couples with surface plasmons in the gold. At a specific angle of incidence, the GCSPR angle, the maximum amount of coupling occurs. Shifts in the GCSPR angle can be correlated with refractive index changes following cell or analyte capture by the immobilized antibodies. In addition, GCSPRI can image the cells as they are being captured. GCSPRI's multiplexed format allows for the parallel assessment of up to 400 individual antibody regions. In this paper, we demonstrate GCSPRI's ability to identify cells and proteins of interest and compare results to a traditional flow cytometry system. This technology represents a fast and powerful method for the simultaneous assessment of cell phenotype and function.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号