首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 93 毫秒
1.
The trace elements Ba, Bi, Cd, Co, Cs, Cu, Hg, La, Mn, Mo, Pb, Rb, Sb, Sn, Sr, Tl, and Zn were determined by inductively coupled plasma mass spectrometry in plasma samples of 68 hemodialysis patients. The same elements (with exception of La and Mn) were also determined in whole blood after mineralization with high-purity nitric acid/hydrogen peroxide in a closed-pressurized microwave system. The accuracy and precision was checked by analyzing two Seronorm “whole blood” reference materials. All samples were contaminated with barium (heparinized tubes) and the plasma samples with tin (collection tubes). The concentrations for Bi, Hg, Pb, Rb, Sb, and Sr in whole blood were within the literature ranges for healthy adults. All of the concentrations for Co, and some of the concentrations for Cd, Cs, Tl, and Zn were higher than the high limits of the normal ranges. Approximately 14% of the Cu concentrations were lower than the low limit of the normal range. The Mo and Sn concentrations are difficult to evaluate, because the normal ranges appears to be unreliable. All concentrations for Cd, Co, Mo, Pb, Sn, and Sr and some of the concentrations for Cu (15%) and Mn (75%) in the plasma samples were higher than the high limits of the normal ranges. The concentrations for Rb tended to be lower than the normal range. To establish unequivocally the causes for elevated and reduced concentrations of trace elements in whole blood and plasma of dialysis patients, all fluids in the dialysis process must be investigated.  相似文献   

2.
The concentrations of 26 major to trace elements in rat kidneys aging from 5 to 113 weeks old were determined. The rats investigated were the same rats used previously reported to have 29 elements in bones (femurs). The samples were decomposed by high purity nitric acid and hydrogen peroxide. Eight elements (Na, Mg, Si, P, K, Ca, Fe and Zn) were determined using inductively coupled plasma atomic emission spectrometry (ICP-AES) and 18 elements (Mn, Co, Ni, Cu, As, Se, Rb, Sr, Mo, Cd, Sn, Sb, Cs, Ba, Tl, Pb, Bi and U) were determined using inductively coupled plasma mass spectrometry (ICP-MS). The aging effects on the concentrations of these elements and mutual elemental relationships were investigated. Analysis of variance (ANOVA) for age variations indicated that the concentrations of P, K, Mn and Mo were almost constant across the age of rats (p > 0.3). The concentration of many elements such as Na, Mg, Ca, Fe, Co, Cu, Zn, As, Se, Cd, Sn, Sb, Tl, Pb and Bi, showed significant increasing trends (p < 0.01) with different patterns. Rubidium, Cs, Pb and Bi showed significant age variations but not monotonic trends. Silicon, Ni, Sr, Ba and U showed large concentration scatterings without any significant trends (p > 0.01). The metabolism of these elements may not be well established in the kidney. Many toxic elements such as As, Cd, Sn, Pb and Bi showed a narrow concentration range among age-matched rats. The kidney may have established metabolic mechanisms to confine or accumulate these toxic elements even though their concentrations are very low (e.g., 10 ng g?1 of Cd). These elements also closely coupled with Fe. A cluster analysis was performed using an elemental correlation matrix and indicated that these elements, including Fe, formed a cluster. However, another cluster analysis using “an aging effect eliminated” elemental correlation showed different clustering in which the Fe, Cd cluster disappeared.  相似文献   

3.
Concentrations of the 18 elements, barium (Ba), beryllium (Be), bismuth (Bi), calcium (Ca), cadmium (Cd), cesium (Cs), copper (Cu), lanthanum (La), lithium (Li), magnesium (Mg), molybdenum (Mo), lead (Pb), rubidium (Rb), antimony (Sb), tin (Sn), strontium (Sr), thallium (Tl), and zinc (Zn), were determined in the synovial fluids of osteoarthritic knee joints and in the corresponding sera of 16 patients by inductively coupled plasma-mass spectrometry. Knee-joint effusions have lower elemental concentrations than their corresponding sera. For the essential elements Ca, Cu, Mg, and Zn and for the nonessential and toxic elements Ba, Be, Bi, La, and Sb, this difference was highly significant. Strong positive correlations between concentrations in effusions and sera for the essential elements Cu and Mg and for the nonessential elements Cs, Li, Rb, and Sr could be established. The grade of localized hyperperfusion of the knee region in the blood pool phase of 99mTc HDP bone scan indicating inflammation did not correlate with any elemental concentration determined. Deceased.  相似文献   

4.
The NDDO semiempirical methods MNDO, AM1, and PM3 have been extended to all the remaining non-radioactive elements of the main group, excluding the noble gases. Most of the new elements are of Groups I and II. 44 sets of parameters are presented for the following methods and elements. MNDO: Na, Mg, K, Ca, Ga, As, Se, Rb, Sr, In, Sb, Te, Cs, Ba, Tl, and Bi; AM1: Li, Be, Na, Mg, K, Ca, Ga, As, Se, Rb, Sr, In, Sn, Sb, Te, Cs, Ba, Tl, Pb, and Bi; PM3: B, Na, K, Ca, Rb, Sr, Cs, and Ba. Average errors are presented for heats of formation, molecular geometries, etc.  相似文献   

5.
The concentrations of 22 major and trace elements in livers from rats aging from 5 to 113 weeks old were determined. The rats investigated were the same rats previously reported with respect to 29 elements in bones (femur) and 26 elements in kidneys. The samples were decomposed with high-purity nitric acid and hydrogen peroxide. Seven elements (Na, Mg, P, K, Ca, Fe and Zn) were determined by inductively coupled plasma atomic emission spectrometry (ICP-AES), and 15 elements (Mn, Co, Cu, As, Se, Rb, Sr, Mo, Cd, Sn, Sb, Cs, Ba, Pb and Bi) were determined by inductively coupled plasma mass spectrometry (ICP-MS). Analysis of variance (ANOVA) for age variations indicated that the concentrations of many elements, such as Mg, P, K, Mn, Fe, Cu, Zn, Sr, Mo and Cd, were almost constant across the ages of the rats with the exception of 5 weeks old (p > 0.05). Arsenic, Pb and Bi showed significant increasing trends, while Na and Co showed decreasing trends (p < 0.01). Selenium showed a decreasing trend except at the initial stage of 5–9 weeks old. Calcium, Rb, Sn, Sb, Cs and Ba showed significant age-related variations, but their patterns were not monotonic. The liver clearly contrasts with the kidneys, in which many elements showed significant age-related variations with increasing trends. The concentration ranges of Mg, P, K, Mn, Cu, Zn, and Mo were controlled within 15% across all ages of rats. The homeostasis of the aforementioned elements may be well established in the liver. The toxic elements, such as Cd, Pb and Bi, showed a narrow concentration range among age-matched rats.  相似文献   

6.
The trace elements Ag, As, Au, B, Ba, Be, Bi, Cd, Ce, Co, Cs, Cu, Ga, Hf, Hg, In, La, Mn, Mo, Ni, Pb, Pd, Rb, Rh, Ru, Sb, Se, Sn, Sr, Te, Th, Tl, U, V, W, Y and Zr were determined in 130 human blood samples from occupationally non-exposed volunteers living in the greater area of Bremen in northern Germany. The blood samples were collected in lithium heparin monovettes developed for trace metal determination and were analysed by inductively coupled plasma mass spectrometry (ICP–MS) with an octopole-based collision/reaction cell. For sample introduction into the ICP, the blood samples were diluted 1/10 (V/V) with a 0.1% Triton-X-100 and 0.5% (V/V) ammonia solution. The method validation of our developed routine method is described for all 37 elements and results about internal and external quality assurance are discussed. Information on exposure conditions of all human subjects were collected by questionnaire-based interviews, including smoking habits, seafood consumption and the type of dental alloys in the teeth. Mean values, geometric mean values, ranges and selected percentiles of all elemental concentrations in human blood are presented, which helps toxicologists and clinical chemists planning research about exposition to metals and health effects caused by exposition to metals.  相似文献   

7.
With inductively coupled plasma-mass spectrometry (ICP-MS), the 18 trace elements Ba, (Be), (Bi), Cd, Co, Cs, Cu, La, Li, Mn, Mo, Pb, Rb, (Sb), (Sn), Sr, (Tl), and Zn were quantified in the digests of 13 formulas based on cow milk, of two formulas based on soy protein, of two milk powders, from which formulas were prepared, of two samples of Austrian cow milk, and in the water, with which the powders were suspended. Concentrations in parentheses were at or below the method detection limits in the formulas. The accuracy and precision of the analytical procedure tested with milk powder reference materials BCR 063 and BCR 150 were satisfactory. The concentrations of trace elements in the powders vary considerably from batch to batch. The ratios of high to low concentrations ranged from 1.1 to 4.8 and were higher for the essential trace elements Co, Cu, Mn, Mo, Sn, and Zn than for nonessential or toxic elements. The contribution of tap water from the water system of the city of Graz, Austria to the concentrations of trace elements in the formulas ranges from 45% for Pb to 0.2% for Rb and is negligible, for instance, for Cd, Cs, La, Mo, and Sn. Preformulas and follow-up formulas are partly supplemented with the essential trace elements Cu, Mn, and Zn and, therefore, concentrations of these trace elements in the formulas vary considerably. However, supplementation of a formula with a particular element must not necessarily result in higher concentrations compared to nonsupplemented formulas. Concentrations of the essential elements were in the following ranges for preformulas, follow-up formulas, soy-based formulas (in μg/kg): Co, 8.3–11.2, 4.5–13, 5.0–5.7; Cu, 330–750, 27–730, 440–530; Mn, 33–580, 40–390, 440–530; Mo, 10–32, 9–39, 44-6; Sn, <0.44-3.8, <0.44-1.0, <0.44-5.8; Zn, 3340-11,380, 4120–7100, 5590-6,840. A preformula supplemented with Mn had a 10 times higher manganese concentration than preformulas without supplementation. Concentrations of all trace elements quantified were lower in cow milk than in formulas and do not meet the dietary requirements of infants.  相似文献   

8.
Despite several studies on metal exposure in the general population, the knowledge on the background burden of distinct metals is still sparse (e.g. Cu, In, Mn, Pb, Sn, Sr, Ta, Te). While up to date reference values exist for 16 distinct metals as Biological Reference Value (BAR) or the 95th percentile for Al, As, Ba, Be, Cd, Co, Cr, Hg, Li, Mo, Ni, Pt, Sb, Se, Tl and U respectively, the background burden of the general population for the remaining elements is unknown or yet no matter of scientific counselling. We established and validated an inductively coupled plasma triple quadrupole mass spectrometry (ICP-MSMS) human biomonitoring method (HBM), that enabled us to determine 26 metals in urine. Al, As, Ba, Be, Cd, Co, Cu, Ga, Gd, Hg, In, Li, Mo, Ni, Pb, Sb, Se, Sn, Sr, Ta, Te, Tl, V and Zn were analyzed. The method was applied to 88 urine samples collected in the ambulance of the Institute for Occupational, Social and Environmental Medicine (IASU) Aachen, Germany. Patients from two major metal processing companies (steel and copper) and a more heterogenous group of occupational exposed and non-exposed persons were defined and distinguished. HBM data from about 88, in general occupationally unexposed persons against certain metals served as a collective representing the general population in first approximation. For these the 95th percentiles are reported. Significant differences of urinary metal concentrations of the employees of the two metal processing companies compared to the third group were observed among others for Cu, Cr, Ni, Mn and are discussed, thus demonstrating the usefulness of the method for both environmental and occupational purposes.  相似文献   

9.
Concentrations of trace elements in newborns, infants, and adults may be significantly different from each other. Serum trace element reference ranges for different age groups are of value for diagnostic purposes. Inductively coupled plasma-mass spectrometry was applied to the determination of the 21 trace elements Ba, Be, Bi, Ca, Cd, Co, Cs, Cu, La, Li, Hg, Mg, Mn, Mo, Pb, Rb, Sb, Sn, Sr, TI, and Zn in a total of 117 sera of individuals representing different age groups. After microwave-assisted acid digestion with high-purity reagents, 20 umbilical cord sera, 5 sera of fully breast-fed infants, 6 sera of formula-fed infants, 66 sera of patients suffering internal diseases, and 20 sera of healthy blood donors were analyzed for trace elements. One serum and two whole-blood reference materials were analyzed for quality control. Experimental concentrations were in good agreement with certified values. Umbilical cord serum concentrations of the essential elements Ca, Co, Cu, and Mg and of the nonessential and toxic elements Ba, Be, Li, Pb, and Sb were elevated compared to the elemental concentrations in the sera of infants and adults. Serum levels of Ba, Ca, Co, Mn, Pb, and Sb of infants were much higher and serum Cu was significantly lower than in adults. Serum Cu increased significantly with age (newborns: 353 microg/L; infants: 755 microg/L; healthy adults: 810 microg/L), whereas for other trace elements no age-dependence could be established.  相似文献   

10.
The preparation of hair for the determination of elements is a critical component of the analysis procedure. Open-beaker, closedvessel microwave, and flowthrough microwave digestion are methods that have been used for sample preparation and are discussed. A new digestion method for use with inductively coupled plasma-mass spectrometry (ICP-MS) has been developed. The method uses 0.2 g of hair and 3 mL of concentrated nitric acid in an atmospheric pressurelow-temperature microwave digestion (APLTMD) system. This preparation method is useful in handling a large numbers of samples per day and may be adapted to hair sample weights ranging from 0.08 to 0.3 g. After digestion, samples are analyzed by ICP-MS to determine the concentration of Li, Be, B, Na, Mg, Al, P, S, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ge, As, Se, Rb, Sr, Zr, Mo, Pd, Ag, Cd, Sn, Sb, I, Cs, Ba, Pt, Au, Hg, Tl, Pb, Bi, Th, and U. Benefits of the APLTMD include reduced contamination and sample handling, and increased precision, reliability, and sample throughput.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号