首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 33 毫秒
1.
2.
AimThe primary aim of this study is to provide preliminary indications for safe constraints of rectum and bladder in patients re-irradiated with stereotactic body RT (SBRT).MethodsData from patients treated for prostate cancer (PCa) and intraprostatic relapse, from 1998 to 2016, were retrospectively collected. First RT course was delivered with 3D conformal RT techniques, SBRT or volumetric modulated arc therapy (VMAT). All patients underwent re-irradiation with SBRT with heavy hypofractionated schedules. Cumulative dose-volume values to organs at risk (OARs) were computed and possible correlation with developed toxicities was investigated.ResultsTwenty-six patients were included. Median age at re-irradiation was 75 years, mean interval between the two RT courses was 5.6 years and the median follow-up was 47.7 months (13.4–114.3 months). After re-irradiation, acute and late G ≥ 2 GU toxicity events were reported in 3 (12%) and 10 (38%) patients, respectively, while late G ≥ 2 GI events were reported in 4 (15%) patients. No acute G ≥ 2 GI side effects were registered. Patients receiving an equivalent uniform dose of the two RT treatments < 131 Gy appeared to be at higher risk of progression (4-yr b-PFS: 19% vs 33%, p = 0.145). Cumulative re-irradiation constraints that appear to be safe are D30% < 57.9 Gy for bladder and D30% < 66.0 Gy, D60% < 38.0 Gy and V122.1 Gy < 5% for rectum.ConclusionPreliminary re-irradiation constraints for bladder and rectum have been reported. Our preliminary investigation may serve to clear some grey areas of PCa re-irradiation.  相似文献   

3.
IntroductionTo investigate the dosimetric impact of daily on-line repositioning during a full course of IMRT for prostate cancer.Materials and methodsTwenty patients were treated with image-guided IMRT. Each pre-treatment plan (Plan A) was compared with a post-treatment plan sum (Plan B) based on couch shifts measured. The delivered dose to the prostate without a daily repositioning was inferred by considering each daily couch shift during the whole course of image-guided IMRT (i.e. plan B). Dose metrics were compared for prostate CTV (P-CTV) and PTV (P-PTV) and for organs at risk. Ten patients were treated with a 5 mm margin and 10 patients with a 10 mm margin.ResultsFor plan A vs plan B: the average D95, D98, D50, D mean and EUD were: 76.4 Gy vs 73.9 Gy (p = 0.0007), 75.4 Gy vs 72.3 Gy (p = 0.001), 78.9 Gy vs 78.4 Gy (p = 0.014), 78.7 Gy vs 77.8 Gy (p = 0.003) and 78.1 Gy vs 75.9 Gy (p = 0.002), respectively for P-CTV, and 73.2 Gy vs 69.3 Gy (p = 0.0006), 70.7 Gy vs 66.0 Gy (p = 0.0008), 78.3 Gy vs 77.5 Gy (p = 0.001), 77.8 Gy vs 76.4 Gy (p = 0.0002) and 74.4 Gy vs 69.2 Gy (p = 0.003), respectively for P-PTV. Margin comparison showed no differences in dose metrics between the two plans except for D98 of the rectum in plan B which was significantly higher with a 10 mm margin.ConclusionsThe absence of daily image-guided IMRT resulted in a significantly less uniform and less homogeneous dose distribution to the prostate. A reduction in PTV margin showed neither a lower target coverage nor a better spare of OAR with and without daily image-guided IMRT.  相似文献   

4.
5.
ObjectiveTo investigate the potential of Particle Swarm Optimization (PSO) for fully automatic VMAT radiotherapy (RT) treatment planning.Material and MethodsIn PSO a solution space of planning constraints is searched for the best possible RT plan in an iterative, statistical method, optimizing a population of candidate solutions. To identify the best candidate solution and for final evaluation a plan quality score (PQS), based on dose volume histogram (DVH) parameters, was introduced.Automatic PSO-based RT planning was used for N = 10 postoperative prostate cancer cases, retrospectively taken from our clinical database, with a prescribed dose of EUD = 66 Gy in addition to two constraints for rectum and one for bladder. Resulting PSO-based plans were compared dosimetrically to manually generated VMAT plans.ResultsPSO successfully proposed treatment plans comparable to manually optimized ones in 9/10 cases. The median (range) PTV EUD was 65.4 Gy (64.7–66.0) for manual and 65.3 Gy (62.5–65.5) for PSO plans, respectively. However PSO plans achieved significantly lower doses in rectum D2% 67.0 Gy (66.5–67.5) vs. 66.1 Gy (64.7–66.5, p = 0.016). All other evaluated parameters (PTV D98% and D2%, rectum V40Gy and V60Gy, bladder D2% and V60Gy) were comparable in both plans. Manual plans had lower PQS compared to PSO plans with −0.82 (−16.43–1.08) vs. 0.91 (−5.98–6.25).ConclusionPSO allows for fully automatic generation of VMAT plans with plan quality comparable to manually optimized plans. However, before clinical implementation further research is needed concerning further adaptation of PSO-specific parameters and the refinement of the PQS.  相似文献   

6.
AimTo assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction.BackgroundImplementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution.Materials and methodsSeventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed.ResultsIn 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively.ConclusionSufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.  相似文献   

7.
Background and purposeTomotherapy treatment planning depends on parameters that are not used conventionally such as: field width (FW), pitch factor (PF) and modulation factor (MF). The aim of this study is to analyze the relationship between these parameters and their influence on the quality of treatment plans and beam-on time.Material and methodsTen prostate cancer patients were included in the study. For each patient, two cases of irradiation were considered depending on the target volume: PTV1 included the prostate gland, seminal vesicles, pelvic lymph nodes and a 1 cm margin, whereas PTV2 included only the prostate gland with a 1 cm margin. For each patient and each case of irradiation (PTV1 and PTV2) 8 treatment plans were created – all consisted of a different combination of planning parameters (FW = 1.05, 2.5, 5 cm; PF = 0.107, 0.215, 0.43; MF = 1.5, 2.5, 3.5). Default values used in this study were FW = 2.5 cm, PF = 0.215 and MF = 2.5. Hence, for plans with different FWs, parameters of PF and MF were 0.215 and 2.5, respectively; for different PFs, FW and MF were 2.5 and 2.5, respectively; finally for different MFs, FW and PF were 2.5 and 0.215, respectively. The reference plan was optimized for FW = 1.05 cm, PF = 0.107 and MF = 3.5, which was assumed to result in the best dose distribution and the longest treatment time. As a result, 160 plans were created. Each plan was analyzed for dose distribution and execution time.Results and conclusion: Treatment plans with FW of 5 cm resulted in the shortest execution time compromising the dose distribution. Moreover, the dose fall off in the longitudinal direction was not sharp. FW of 1.05 cm and PF of 0.107 were not recommended for routine prostate plans due to long execution time, which was 3 times longer than for plans with FW = 5 cm. There was no substantial decrease of irradiation time when PF was increased from 0.215 to 0.43 for both cases (PTV1 and PTV2); however, the dose distribution was slightly compromised. Finally, decreasing MF from 2.5 to 1.5 was useless because it did not change the beam-on time; however, it did remarkably decrease the dose distribution. Nevertheless, increasing MF up to 3.5 could be considered. The lowest EUD for the rectum and intestines, could be observed for PF = 0.107. For the other plans the differences were rather small (the EUD was almost the same). By reducing PF from 0.43 to 0.107 or FW from 5 to 1.05 the EUD for bladder (in PTV1 case) decreased by 3.13% and 2.60%. When PTV2 was a target volume, the EUD for bladder decreased by 4.54% and 3.43% when FW was changed from 5 to 1.05 and MF from 1.5 to 3.5, respectively. For optimal balance between beam-on time and dose distribution in OARs for routine patients, the authors would suggest to use: FW = 2.5, PF = 0.215 and MF = 2.5.  相似文献   

8.
The impact of a rectal spacer and an increased near maximum target dose in VMAT prostate SBRT is studied.For a group of 11 patients (35 Gy-in-five-fractions VMAT prostate SBRT) a set of 4 plans were generated, namely two VMAT plans, with D2%  37.5 Gy (Hom) and with D2%  40.2 Gy (Het), were created for each of two CT scans taken before (NoSpc) and after (Spc) transperineal spacer insertion. Consequently the methodology for parameter invariant TCP (tumor control probability) plan ranking was applied for comparison of the plans in terms of tumor control. NTCPs (normal tissue complication probabilities) were calculated for rectum and bladder using Lyman’s model.For all 11 patients the TCP plan ranking has shown that the Het plans would perform considerably better in TCP terms than the Hom ones. The plans without rectal spacer were ranked worse compared to those with rectal spacer except for one set of Hom plans. The calculated NTCPs for rectum produced by the Het plans were quite similar to the NTCPs of the Hom ones. The rectal NTCPs of the Hom Spc plans were always lower than the NTCPs of the Hom NoSpc plans. The NTCP values for bladder were extremely low in all cases.The use of rectal spacer leads in general to lower risk of rectal complications, as expected, and even to better tumor control. Plans with increased near maximum target dose (D2%  40.2 Gy) are expected to perform much better in terms of tumor control than those with D2%  37.5 Gy.  相似文献   

9.
PurposeEvaluating performance of modern dose calculation algorithms in SBRT and locally advanced lung cancer radiotherapy in free breathing (FB) and deep inspiration breath hold (DIBH).MethodsFor 17 patients with early stage and 17 with locally advanced lung cancer, a plan in FB and in DIBH were generated with Anisotropic Analytical Algorithm (AAA). Plans for early stage were 3D-conformal SBRT, 45 Gy in 3 fractions, prescribed to 95% isodose covering 95% of PTV and aiming for 140% dose centrally in the tumour. Locally advanced plans were volumetric modulated arc therapy, 66 Gy in 33 fractions, prescribed to mean PTV dose. Calculation grid size was 1 mm for SBRT and 2.5 mm for locally advanced plans. All plans were recalculated with AcurosXB with same MU as in AAA, for comparison on target coverage and dose to risk organs.ResultsLung volume increased in DIBH, resulting in decreased lung density (6% for early and 13% for locally-advanced group).In SBRT, AAA overestimated mean and near-minimum PTV dose (p-values < 0.01) compared to AcurosXB, with largest impact in DIBH (differences of up to 11 Gy). These clinically relevant differences may be a combination of small targets and large dose gradients within the PTV.In locally advanced group, AAA overestimated mean GTV, CTV and PTV doses by median less than 0.8 Gy and near-minimum doses by median 0.4–2.7 Gy.No clinically meaningful difference was observed for lung and heart dose metrics between the algorithms, for both FB and DIBH.ConclusionsAAA overestimated target coverage compared to AcurosXB, especially in DIBH for SBRT.  相似文献   

10.
11.
PurposeThis study aims to investigate the feasibility of using convolutional neural networks to predict an accurate and high resolution dose distribution from an approximated and low resolution input dose.MethodsSixty-six patients were treated for prostate cancer with VMAT. We created the treatment plans using the Acuros XB algorithm with 2 mm grid size, followed by the dose calculated using the anisotropic analytical algorithm with 5 mm grid with the same plan parameters. U-net model was used to predict 2 mm grid dose from 5 mm grid dose. We investigated the two models differing for the training data used as input, one used just the low resolution dose (D model) and the other combined the low resolution dose with CT data (DC model). Dice similarity coefficient (DSC) was calculated to ascertain how well the shape of the dose-volume is matched. We conducted gamma analysis for the following: DVH from the two models and the reference DVH for all prostate structures.ResultsThe DSC values in the DC model were significantly higher than those in the D model (p < 0.01). For the CTV, PTV, and bladder, the gamma passing rates in the DC model were significantly higher than those in the D model (p < 0.002–0.02). The mean doses in the CTV and PTV for the DC model were significantly better matched to those in the reference dose (p < 0.0001).ConclusionsThe proposed U-net model with dose and CT image used as input predicted more accurate dose.  相似文献   

12.
PurposeTo demonstrate the strength of an innovative knowledge-based model-building method for radiotherapy planning using hypofractionated, multi-target prostate patients.Material and methodsAn initial RapidPlan model was trained using 48 patients who received 60 Gy to prostate (PTV60) and 44 Gy to pelvic nodes (PTV44) in 20 fractions. To improve the model's goodness-of-fit, an intermediate model was generated using the dose-volume histograms of best-spared organs-at-risk (OARs) of the initial model. Using the intermediate model and manual tweaking, all 48 cases were re-planned. The final model, trained using these re-plans, was validated on 50 additional patients. The validated final model was used to determine any planning advantage of using three arcs instead of two on 16 VMAT cases and tested on 25 additional cases to determine efficacy for single-PTV (PTV60-only) treatment planning.ResultsFor model validation, PTV V95% of 99.9% was obtained by both clinical and knowledge-based planning. D1% was lower for model plans: by 1.23 Gy (PTV60, CI = [1.00, 1.45]), and by 2.44 Gy (PTV44, CI = [1.72, 3.16]). OAR sparing was superior for knowledge-based planning: ΔDmean = 3.70 Gy (bladder, CI = [2.83, 4.57]), and 3.22 Gy (rectum, CI = [2.48, 3.95]); ΔD2% = 1.17 Gy (bowel bag, CI = [0.64, 1.69]), and 4.78 Gy (femoral heads, CI = [3.90, 5.66]). Using three arcs instead of two, improvements in OAR sparing and PTV coverage were statistically significant, but of magnitudes < 1 Gy. The model failed at reliable DVH predictions for single PTV plans.ConclusionsOur knowledge-based model delivers efficient, consistent plans with excellent PTV coverage and improved OAR sparing compared to clinical plans.  相似文献   

13.
AimTo investigate the predictive value of convenience of rectum dosimetry with Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC) dose limits, maximum rectum dose (Dmax), total rectal volume (TVrectum), rectal volume included in PTV (VrectumPTV) on Grade 2–3 acute rectal toxicity for utilization in clinical practice.BackgroundNumerous previous data have reported frequent acute proctitis after external-beam RT of prostate cancer. Predicting toxicity limited with dose information is inadequate in clinical practice due to comorbidities and medications used.Materials and MethodSixty-four non-metastatic prostate cancer patients treated with IMRT were enrolled. Patients were treated to a total dose of 70–76 Gy. Rectal dose volume histograms (DVH) of all patients were evaluated retrospectively, and a QUANTEC Score between 0 and 5 was calculated for each patient. The correlation between the rectal DVH data, QUANTEC score, TVrectum, VrectumPTV, rectum Dmax and Grade 2–3 rectal toxicity was investigated.ResultsIn the whole group grade 1, 2 and 3 acute rectal toxicities were 25%, 18.8% and 3.1%, respectively. In the DVH data, rectum doses of all patients were under RTOG dose limits. Statistically significant correlation was found between grade 2–3 rectal toxicity and TVrectum (p = 0,043); however. It was not correlated with QUANTEC score, VrectumPTV and Dmax.ConclusionOur results were not able to show any significant correlation between increasing convenience with QUANTEC limits and lower rectal toxicity. Conclusively, new dosimetric definitions are warranted to predict acute rectal toxicity more accurately in prostate cancer patients during IMRT treatment.  相似文献   

14.
PurposeRadiation treatment planning inherently involves multiple conflicting planning goals, which makes it a suitable application for multicriteria optimization (MCO). This study investigates a MCO algorithm for VMAT planning (VMAT–MCO) for prostate cancer treatments including pelvic lymph nodes and uses standard inverse VMAT optimization (sVMAT) and Tomotherapy planning as benchmarks.MethodsFor each of ten prostate cancer patients, a two stage plan was generated, consisting of a stage 1 plan delivering 22 Gy to the prostate, and a stage 2 plan delivering 50.4 Gy to the lymph nodes and 56 Gy to the prostate with a simultaneous integrated boost. The single plans were generated by three planning techniques (VMAT–MCO, sVMAT, Tomotherapy) and subsequently compared with respect to plan quality and planning time efficiency.ResultsPlan quality was similar for all techniques, but sVMAT showed slightly better rectum (on average Dmean −7%) and bowel sparing (Dmean −17%) compared to VMAT–MCO in the whole pelvic treatments. Tomotherapy plans exhibited higher bladder dose (Dmean +42%) in stage 1 and lower rectum dose (Dmean −6%) in stage 2 than VMAT–MCO. Compared to manual planning, the planning time with MCO was reduced up to 12 and 38 min for stage 1 and 2 plans, respectively.ConclusionMCO can generate highly conformal prostate VMAT plans with minimal workload in the settings of prostate-only treatments and prostate plus lymph nodes irradiation. In the whole pelvic plan manual VMAT optimization led to slightly improved OAR sparing over VMAT–MCO, whereas for the primary prostate treatment plan quality was equal.  相似文献   

15.
AimTo compare the radiotherapy technique used in a randomised trial with VMAT and an in-house technique for prostate cancer.BackgroundTechniques are evolving with volumetric modulated arc therapy (VMAT) commonly used. The CHHiP trial used a 3 PTV forward planned IMRT technique (FP_CH). Our centre has adopted a simpler two PTV technique with locally calculated margins.Materials and methods25 patients treated with FP_CH to 60 Gy in 20 fractions were re-planned with VMAT (VMAT_CH) and a two PTV protocol (VMAT_60/52 and VMAT_60/48). Target coverage, conformity index (CI), homogeneity index (HI), monitor units (MU) and dose to the rectum, bladder, hips and penile bulb were compared.ResultsPTV coverage was high for all techniques. VMAT_CH plans had better CI than FP_CH (p   0.05). VMAT_60/52/48 plans had better CI than VMAT_CH. FP_CH had better HI and fewer MU than VMAT (p   0.05). More favourable rectum doses were found for VMAT _CH than FP_CH (V48.6, V52.8, V57, p   0.05) with less difference for bladder (p   0.05). Comparing VMAT_CH to VMAT_60/52/48 showed little differences for the bladder and rectum but VMAT_CH had larger penile bulb doses (V40.8, V48.6, mean, D2, p   0.05). Femoral head doses (V40.8) were similarly low for all techniques (p = ≥ 0.05).ConclusionVMAT produced more conformal plans with smaller rectum doses compared to FP_CH albeit worse HI and more MU. VMAT_60/52 and VMAT_60/48 plans had similar rectal and bladder doses to VMAT_CH but better CI and penile bulb doses which may reduce toxicity.  相似文献   

16.
AimTo discuss current dosage for stereotactic body radiation therapy (SBRT) in hepatocellular carcinoma (HCC) patients and suggest alternative treatment strategies according to liver segmentation as defined by the Couinaud classification.BackgroundSBRT is a safe and effective alternative treatment for HCC patients who are unable to undergo liver ablation/resection. However, the SBRT fractionation schemes and treatment planning strategies are not well established.Materials and methodsIn this article, the latest developments and key findings from research studies exploring the efficacy of SBRT fractionation schemes for treatment of HCC are reviewed. Patients’ characteristics, fractionation schemes, treatment outcomes and toxicities were compiled. Special attention was focused on SBRT fractionation approaches that take into consideration liver segmentation according to the Couinaud classification and functional hepatic reserve based on Child–Pugh (CP) liver cirrhosis classification.ResultsThe most common SBRT fractionation schemes for HCC were 3 × 10–20 Gy, 4–6 × 8–10 Gy, and 10 × 5–5.5 Gy. Based on previous SBRT studies, and in consideration of tumor size and CP classification, we proposed 3 × 15–25 Gy for patients with tumor size <3 cm and adequate liver reserve (CP-A score 5), 5 × 10–12 Gy for patients with tumor sizes between 3 and 5 cm or inadequate liver reserve (CP-A score 6), and 10 × 5–5.5 Gy for patients with tumor size >5 cm or CP-B score.ConclusionsTreatment schemes in SBRT for HCC vary according to liver segmentation and functional hepatic reserve. Further prospective studies may be necessary to identify the optimal dose of SBRT for HCC.  相似文献   

17.
PurposeAdaptive Stereotactic Body Radiotherapy (SBRT) of prostate cancer (PC) by online 1.5 T MRi-guidance prolongs session-time, due to contouring and planning tasks, thus increasing the risk of prostate motion. Hence, the interest to verify the adequacy of the delivered dose.Material and methodsFor twenty PC patients treated by 35 Gy (Dp) in five fractions, daily pre- and post- delivery MRi scans were respectively used for adapt-to-shape (ATS) optimization, and re-computation of the delivered irradiation (Drec). Two expansion recipes, from Clinical (CTV) to Planning target volume (PTV), which slightly differed in the posterior margin were used for groups I and II, of ten patients each. Plans had to assure D95% ≥ 95%Dp to PTV, and D1cc ≤ Dp to rectum, bladder, penile bulb, and urethral planning-risk-volume (urethral-PRV). The adequacy of the delivered dose was estimated by inter-fraction average (ifa) of dose-volume metrics computed from Drec. A cumulative dose (Dsum) was calculated from the five daily Drec deformed onto the simulation MRi.ResultsFor each patient, CTV coverage resulted in D95% > 95%Dp when estimated as ifa by Drec. No significant difference for D95% and D99% metrics to CTV resulted between groups I and II. D1cc was < Dp for rectum, urethral-PRV, and penile bulb, whereas < 103.5%Dp for the bladder.Significant correlations resulted between metrics computed by Dsum and as ifa by Drec, by both linear-correlation analysis, and Receiver-Operating-Characteristic curve analysis.ConclusionsOur results for PC-SBRT confirm the adequacy of the delivered dose by ATS with 1.5 T MR-linac, and the consistency between dose-volume metrics computed by Drec and Dsum.  相似文献   

18.
PurposeThe log file-based patient dose estimation includes a residual dose estimation error caused by leaf miscalibration, which cannot be reflected on the estimated dose. The purpose of this study is to determine this residual dose estimation error.Methods and materialsModified log files for seven head-and-neck and prostate volumetric modulated arc therapy (VMAT) plans simulating leaf miscalibration were generated by shifting both leaf banks (systematic leaf gap errors: ±2.0, ±1.0, and ±0.5 mm in opposite directions and systematic leaf shifts: ±1.0 mm in the same direction) using MATLAB-based (MathWorks, Natick, MA) in-house software. The generated modified and non-modified log files were imported back into the treatment planning system and recalculated. Subsequently, the generalized equivalent uniform dose (gEUD) was quantified for the definition of the planning target volume (PTV) and organs at risks.ResultsFor MLC leaves calibrated within ±0.5 mm, the quantified residual dose estimation errors that obtained from the slope of the linear regression of gEUD changes between non- and modified log file doses per leaf gap are in head-and-neck plans 1.32 ± 0.27% and 0.82 ± 0.17 Gy for PTV and spinal cord, respectively, and in prostate plans 1.22 ± 0.36%, 0.95 ± 0.14 Gy, and 0.45 ± 0.08 Gy for PTV, rectum, and bladder, respectively.ConclusionsIn this work, we determine the residual dose estimation errors for VMAT delivery using the log file-based patient dose calculation according to the MLC calibration accuracy.  相似文献   

19.
PurposeStereotactic body image guided radiation therapy (SBRT) shows good results for lung cancer treatment. Better normal tissue sparing might be achieved with scanned carbon ion therapy (PT). Therefore an in silico trial was conducted to find potential advantages of and patients suited for PT.MethodsFor 19 patients treated with SBRT, PT plans were calculated on 4D-CTs with simulated breathing motion. Prescribed single fraction dose was 24 Gy and OAR constraints used for photon planning were respected. Motion was mitigated by rescanning and range-adapted ITVs. Doses were compared to the original SBRT plans.ResultsCTV coverage was the same in SBRT and PT. The field-specific PTV including range margins for PT was 1.5 (median, 25–75% 1.3–2.1) times larger than for SBRT. Nevertheless, maximum point dose and mean dose in OARs were higher in SBRT by 2.8 (1.6–3.7) Gy and 0.7 (0.3–1.6) Gy, respectively. Patients with a CTV >2.5 cc or with multiple lung lesions showed larger differences in OAR doses in favor of PT.ConclusionsPatients receive less dose in critical OARs such as heart, spinal cord, esophagus, trachea and aorta with PT, while maintaining the same target coverage. Patients with multiple or larger lesions are particularly suited for PT.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号