首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The ability of an anaerobic hybrid reactor, treating coffee wastewater, to achieve a quick start-up was tested at pilot scale. The unacclimatized seed sludge used showed a low specific methanogenic activity of 26.47 g CH4 as chemical oxygen demand (COD)/kg volatile suspended solids (VSS) x day. This strongly limited the reactor performance. After a few days of operation, a COD removal of 77.2% was obtained at an organic loading rate (OLR) of 1.89 kg COD/m3 x day and a hydraulic retention time (HRT) of 22 h. However, suddenly increasing OLR above 2.4 kg COD/m3 x day resulted in a deterioration in treatment efficiency. The reactor recovered from shock loads after shutdowns of 1 week. The hybrid design of the anaerobic reactor prevented the biomass from washing-out but gas clogging in the packing material was also observed. Wide variations in wastewater strength and flow rates prevented stable reactor operation in the short period of the study.  相似文献   

2.
固定载体卧式厌氧反应器处理糖蜜废水的快速启动   总被引:1,自引:0,他引:1  
为高效处理高浓度有机废水而设计了固定载体卧式厌氧反应器R1和R2, 它是厌氧折流板反应器(ABR)的改进, 以活性炭纤维作为生物膜载体固定并充当反应器的折流板, 在实验室规模上对R1和R2处理糖蜜废水进行快速启动运行。HRT和ORL是影响R1和R2稳定高效运行及启动的2个重要工艺参数。实验证明: HRT为2 d时, 反应器运行最佳。在第30天时, R1的COD去除率达到84.88%, R2达到81.72%。随着进水ORL由1.25 kg/(m3·d)提升到10 kg/(m3·d), 沼气容积产气率由0.35 L/(L·d)逐渐增加到4.98 L/(L·d)。进水pH值为3.9?4.5之间, 整个启动运行过程中, 未调节pH值, R1和R2的出水pH值均在6.7?7.6之间, 2个反应器均有较强的抗酸能力, R1的pH波动更为平缓。在整个实验过程中, 污泥流失量小, 没有发生堵塞现象, 在处理酸性高浓度有机废水时, 2个反应器均表现出较强的抗负荷冲击能力。  相似文献   

3.
In this study, performance of a lab-scale hybrid up-flow anaerobic sludge blanket (UASB) reactor, treating a chemical synthesis-based pharmaceutical wastewater, was evaluated under different operating conditions. This study consisted of two experimental stages: first, acclimation to the pharmaceutical wastewater and second, determination of maximum loading capacity of the hybrid UASB reactor. Initially, the carbon source in the reactor feed came entirely from glucose, applied at an organic loading rate (OLR) 1 kg COD/m(3) d. The OLR was gradually step increased to 3 kg COD/m(3) d at which point the feed to the hybrid UASB reactor was progressively modified by introducing the pharmaceutical wastewater in blends with glucose, so that the wastewater contributed approximately 10%, 30%, 70%, and ultimately, 100% of the carbon (COD) to be treated. At the acclimation OLR of 3 kg COD/m(3) d the hydraulic retention time (HRT) was 2 days. During this period of feed modification, the COD removal efficiencies of the anaerobic reactor were 99%, 96%, 91% and 85%, and specific methanogenic activities (SMA) were measured as 240, 230, 205 and 231 ml CH(4)/g TVS d, respectively. Following the acclimation period, the hybrid UASB reactor was fed with 100% (w/v) pharmaceutical wastewater up to an OLR of 9 kg COD/m(3) d in order to determine the maximum loading capacity achievable before reactor failure. At this OLR, the COD removal efficiency was 28%, and the SMA was measured as 170 ml CH(4)/g TVS d. The hybrid UASB reactor was found to be far more effective at an OLR of 8 kg COD/m(3) d with a COD removal efficiency of 72%. At this point, SMA value was 200 ml CH(4)/g TVS d. It was concluded that the hybrid UASB reactor could be a suitable alternative for the treatment of chemical synthesis-based pharmaceutical wastewater.  相似文献   

4.
Treatment of simulated wastewater containing 40 mg/l of 4-chlorophenol (4-CP) was carried out in an upflow anaerobic sludge blanket (UASB) reactor under methanogenic condition. The performance of this test UASB reactor was evaluated in terms of 4-CP removal. Hydraulic retention time (HRT) and substrate:co-substrate ratio for the 4-CP removal was optimized by varying the influent flow rate (13-34.7 ml/min) and sodium acetate concentration (2-5 g/l), respectively. A control UASB reactor, which was not exposed to 4-CP was also operated under similar conditions. Organic loading rate (OLR) was varied in the range of 2-5.3 kg/m(3)/d and 1.7-4.2 kg/m(3)/d, respectively, for HRT and substrate:co-substrate ratio studies, respectively. The optimum HRT and substrate:co-substrate ratio for the removal of 4-CP was 12h and 1:75, respectively. Removal of 4-CP achieved at optimum HRT and substrate:co-substrate ratio was 88.3+/-0.7%. Removal of 4-CP occurred through dehalogenation and caused increase in chloride ion concentration in the effluent by 0.23-0.27 mg/mg 4-CP removed. The ring cleavage test showed the ortho mode of ring cleavage of 4-CP. Change in the elemental composition of the anaerobic biomass of UASB reactors was observed during the study period. Concentration of Ca(2+) increased in the biomass and this could be attributed to the biosoftening. Specific methanogenic activity of the sludge of control and test UASB reactor was 0.832 g CH(4) COD/g VSS d and 0.694 g CH(4) COD/g VSS d, respectively.  相似文献   

5.
The effect of temperature and organic loading rate on the rate of methane production from acidic petrochemical wastewater without neutralization was investigated by continuously feeding an anaerobic upflow fixed-film reactor. The temperatures selected for the studies were 25, 37, 45 and 55 degrees C. Organic loading rate (OLR) for each temperature was varied from 3.6 to 21.7 kg COD m(-3) d(-1). Best performance with respect to COD and BOD reduction, total gas production and methane yield was obtained with the reactor operating at 37 degrees C. OLR could be increased to a maximum of 21.7 kg COD m(-3) d(-1) with 90-95% COD and BOD reduction and methane yield of 0.450 m3 kg(-1) COD d(-1) added. The reactor operating at 55 degrees C gave the highest methane yield of 0.666 m3 kg(-1) COD d(-1) at an OLR of 6 kg COD m(-3) d(-1). This decreased to 0.110 m3 kg(-1) COD d(-1) when the OLR was increased to 18.1 kg COD m(-3) d(-1). The reactor operating at 45 degrees C gave a maximum methane yield of 0.416 m3 kg(-1) COD d(-1) added at an OLR of 6 kg COD m(-3) d(-1). On further increasing the OLR to 9 kg COD m(-3) d(-1), COD reduction was 89%, however, methane yield decreased to 0.333 m3 kg(-1) COD d(-1) added. The highest methane yield of 0.333 m3 kg(-1) COD d(-1) added at an OLR of 6 kg COD m(-3) d(-1) was obtained with reactors operating at 25 degrees C. These studies indicate potential rates of methane production from acidic petrochemical wastewater under different temperatures. This provides a guideline for various kinetic analyses and economic evaluation of the potential feasibility of fermenting acidic wastewater to methane.  相似文献   

6.
The aim of this work was to study the influence of influent chemical oxygen demand (COD), upflow velocity of wastewater, and cationic polymer additives in inoculum, on biomass granulation and COD removal efficiency in upflow anaerobic sludge blanket (UASB) reactor for treating low strength wastewater. Statistical models were formulated based on these three variables to optimize the biomass granulation and COD removal efficiency in UASB reactors using a two-level, full factorial design. For the thick inoculum used in this study, having suspended solids (SS) >80 g/l and volatile suspended solids (VSS) to SS ratio <0.3, cationic polymer additives in the inoculum showed adverse effect on biomass granulation and COD removal efficiency. It is concluded that for such thick inoculum, granulation can be obtained while treating low strength wastewaters in UASB reactor by selecting proper combination of influent COD and liquid upflow velocity so as to represent the organic loading rate (OLR) greater than 1.0 kg COD/m(3) d. Validation of model predictions for treatment of synthetic wastewater and actual sewage reveals the efficacy of these models for enhancing granulation and COD removal efficiency.  相似文献   

7.
A 19.2 l multiplate anaerobic reactor (MPAR) was used to assess the impact of lime (Ca(OH)2) on the anaerobic treatment of whey permeate effluents. The amount of Ca(OH)2 required to maintain the pH of the whey permeate around 5 ranged between 3.0 and 4.5 kg/m3, which corresponded to concentration varying between 1.62 and 2.43 kg/m3. Soluble chemical oxygen demand (COD) removal efficiency exceeded 92% with a methane production rate of 6.7 m3/m3.d. at an organic loading rate (OLR) as high as 20 kg COD/m3.d. Extended operation of the MPAR resulted in the accumulation of significant amounts of calcium precipitates in the sludge bed which reached after three months of operation 0.19, 0.25 and 0.33 kg Ca2+ per kg of suspended solid (SS) in the lower, the middle and the upper compartment of the MPAR, respectively. The volatile suspended solids to suspended solids ratio (VSS/SS) decreased from 0.83 in inoculum to 0.37, 0.22 and 0.08 in the lower, the middle and the upper compartment of the MPAR, respectively. As a result, the soluble COD reduction and the methane production rate decreased to 31% and to 2.3 m3/m3.d. respectively, at OLR of 20 kg COD/m3.d.The authors thank Saputo Cheese Ltd. for providing the whey permeate effluents, Alain Corriveau for expert analytical assistance and Hervé Macarie for revising the article. NRC Paper No. 33907  相似文献   

8.
This paper examines the effect of organic loading rate on the removal efficiency of COD and TOC anaerobic thermophilic fluidized bed reactor (AFBR) in the treatment of cutting-oil wastewater at different hydraulic retention time (HRT) conditions. The essays are development at laboratory scale using a porous support medium. The AFBR reactor was subjected to a programme of steady-state operation over a range of hydraulic retention times, HRTs, in the range 12-2h and organic loading rates, OLRs, between 11.9 and 51.3kgCOD/m(3)d. The highest efficiency was 95.9% for an OLR of 13kgCOD/m(3)d and HRT of 11h. Over an operating period of 92 days, an OLR of 51.3kgCOD/m(3)d was achieved with 67.1% COD removal efficiency (71.3% TOC) in the experimental AFBR reactor. Although the level of biogas generation was not high, the anaerobic fluidized bed technology provided significant advantages over the conventional physico-chemical treatment applied in the factory. The effluent had a better quality (lower organic loading) and it was possible to reuse it in different applications in the factory (e.g., irrigation of gardens). The biological treatment did not lead to the generation of oily sludge, which is considered as hazardous waste by legislation. Furthermore, a continuous stream is produced and this reduced the impact of large flows discharged 4-5 times per week to the urban collector and MWWTP (municipal wastewater treatment plant).  相似文献   

9.
The study was aimed at treating the complex, combined wastewater generated in Mangolpuri industrial cluster. It was considered as a low strength wastewater with respect to its organic content. Anaerobic treatment of this wastewater was studied using an anaerobic hybrid reactor (AHR) which combined the best features of both the upflow anaerobic sludge blanket (UASB) reactor and anaerobic fluidized bed rector (AFBR). The performance of the reactor under different organic and hydraulic loading rates were studied. The COD removal reached 94% at an organic loading rate (OLR) of 2.08 kg COD m(-3)d(-1) at an hydraulic retention time (HRT) of 6.0 h. The granules developed were characterized in terms of their diameter and terminal settling velocity.  相似文献   

10.
In this study wastewaters of a sunflower oil factory in Elazig (Turkey) were investigated in a pilot-scale mesophilic upflow anaerobic sludge blanket (UASB) reactor by determination of removal of total lipids (TL) and fatty acids (FA). The removal efficiencies of TL and FA (linoleic, oleic, myristic, palmitic, stearic, arashidic, behenic and other FA) were above 70% at organic loading rates (OLR) between 1.6 and 7.8 kg COD/m(3)d and at optimum hydraulic retention times of 2.0 and 2.8 day. The conversion rate of removed COD to methane was between 0.16 and 0.354 m(3) CH(4)/kg COD.  相似文献   

11.
Cherry stillage is a high strength organic wastewater arising from the manufacture of alcoholic products by distillation of fermented cherries. It is made up of biorefractory polyphenols in addition to readily biodegradable organic matter. An anaerobic sequencing batch reactor (AnSBR) was used to treat cherry stillage at influent COD ranging from 5 to 50 g/L. Different cycle times were selected to test biomass organic loading rates (OLR(B)), from 0.3 to 1.2 g COD/g VSS.d. COD and TOC efficiency removals higher than 80% were achieved at influent COD up to 28.5 g/L but minimum OLR(B) tested. However, as a result of the temporary inhibition of acetogens and methanogens, volatile fatty acids (VFA) noticeably accumulated and methane production came to a transient standstill when operating at influent COD higher than 10 g/L. At these conditions, the AnSBR showed signs of instability and could not operate efficiently at OLR(B) higher than 0.3 g COD/g VSS.d. A feasible explanation for this inhibition is the presence of toxic polyphenols in cherry stillage. Thus, an ozonation step prior to the AnSBR was observed to be useful, since more than 75% of polyphenols could be removed by ozone. The integrated process was shown to be a suitable treatment technology as the following advantages compared to the single AnSBR treatment were observed: greater polyphenols and color removals, higher COD and TOC removal rates thus enabling the process to effectively operate at higher OLR, higher degree of biomethanation, and good stability with less risk of acidification.  相似文献   

12.
The effect of cationic polymer additives on biomass granulation and COD removal efficiency had been examined in lab-scale upflow anaerobic sludge blanket (UASB) reactors, treating low strength synthetic wastewater (COD 300-630 mg/l). Under identical conditions, two reactors were operated with and without polymer additives in inoculum under four different organic loading rates (OLRs). The optimum polymer dose was adopted based upon the results of jar test and settling test carried out with inoculum seed sludge. With the use of thick inoculum, SS greater than 110 g/l and VSS/SS ratio less than 0.3, granulation was observed in UASB reactor treating synthetic wastewater as well as actual sewage, when OLR was greater than 1.0 kg COD/m(3) d. Polymer additive with such thick inoculum was observed to deteriorate percentage granules and COD removal efficiency compared to inoculum without polymer additives. At OLR less than 1.0 kg COD/m(3) d, proper granulation could not be achieved in both the reactors inoculated with and without polymer additive. Also, under this low loading, drastic reduction in COD removal efficiency was observed with polymer additives in inoculum. Hence, it is rational to conclude that biomass granulation for treatment of low strength biodegradable wastewater depends on the applied loading rate and selection of thick inoculum sludge.  相似文献   

13.
This study presents the performance characteristics of a plug flow phase separated anaerobic granular bed baffled reactor (GRABBR) fed with brewery wastewater at various operating conditions. The reactor achieved chemical oxygen demand (COD) removal of 93-96% with high methane production when operated at organic loading rates (OLRs) of 2.16-13.38kg COD m(-3)d(-1). The reactor configuration and microbial environment encouraged the acidogenic dominant zone to produce intermediate products suitable for degradation in the predominantly methanogenic zone. Noticeable phase separation between acidogenesis and methanogenesis mainly occurred at high OLR, involving a greater number of compartments to contribute to wastewater treatment. The highly active nature and good settling characteristics of methanogenic granular sludge offered high biomass retention and enhanced methanogenic activities within the system. The granular structure in the acidogenic dominant zone of the GRABBR was susceptible to disintegration and flotation. Methanogenic granular sludge was a multi-layered structure with Methanosaeta-like organisms dominant in the core.  相似文献   

14.
Studies are carried out on the treatment of wastewater from a bulk drug industry using an anaerobic fixed film reactor (AFFR) designed and fabricated in the laboratory. The chemical oxygen demand (COD) and total dissolved solids (TDS) of the wastewater are found to be very high with low Biochemical oxygen demand (BOD) to COD ratio and high total suspended solid (TSS) concentration. Acclimatization of seed consortia and start up of the reactor is carried out by directly using the wastewater, which resulted in reducing the period of startup to 30 days. The reactor is studied at different organic loading rates (OLR) and it is found that the optimum OLR is 10 kg COD/m3/day. The wastewater under investigation, which is having considerable quantity of SS, is treated anaerobically without any pretreatment. The COD and BOD of the reactor outlet wastewater are monitored and reduction at steady state and optimum OLR is observed to be 60-70% of COD and 80-90% of BOD. The reactor is subjected to organic shock loads at two different OLR and it is observed that the reactor could withstand shocks and performance could be restored to normalcy at that OLR. The results obtained indicated that AFFR could be used efficiently for the treatment of wastewater from a bulk drug industry having high COD, TDS and TSS.  相似文献   

15.
Studies were carried out on the treatment of wastewater from a bulk drug industry using an anaerobic fixed film reactor (AFFR) designed and fabricated in the laboratory. The chemical oxygen demand (COD) and total dissolved solids (TDS) of the wastewater were found to be very high with low biochemical oxygen demand (BOD) to COD ratio and high total suspended solid (TSS) concentration. Acclimatization of seed consortia and startup of the reactor was carried out by directly using the wastewater, which resulted in reducing the period of startup to 30 days. The reactor was studied at different organic loading rates (OLR) and it was found that the optimum OLR was 10 kg COD/m(3)/day. The wastewater under investigation, which had a considerable quantity of SS, was treated anaerobically without any pretreatment. COD and BOD of the reactor outlet wastewater were monitored and at steady state and optimum OLR 60-70% of COD and 80-90% of BOD were removed. The reactor was subjected to organic shock loads at two different OLR and the reaction could withstand the shocks and performance could be restored to normalcy at that OLR. The results obtained indicated that AFFR could be used efficiently for the treatment of wastewater from a bulk drug industry having high COD, TDS and TSS.  相似文献   

16.
Treatment of brewery slurry in a thermophilic anaerobic sequencing batch reactor (ASBR) was studied using conventional fully mixed semi-continuous digestion as a control. The process phases were adapted to fit the brewery slurry discharge schedule. ASBR experiments were conducted under different organic loading rates (OLR) from 3.23 to 8.57 kg of COD/m(3)day of reactor and control was conducted with OLR of 3.0 kg of COD/m(3)day. The ASBR COD degradation efficiency was from 79.6% to 88.9%, control experiment efficiency was 65%. ASBR VSS removal efficiency was from 78.5% to 90.5%, control experiment efficiency was 54%. The ASBR methane production yield was from 371 to 418 L/kg COD inserted, control experiment methane yield was 248 L/kg COD inserted. The ASBR process was superior to conventional fully mixed digestion, and is fully adaptable to brewery slurry discharge, needs no additional collection and settling pools and experiences no solids settling problems.  相似文献   

17.
A two-stage anaerobic treatment pilot plant was tested for the treatment of raw domestic wastewater under temperatures ranging from 21 to 14 degrees C. The plant consisted of a hydrolytic upflow sludge bed (HUSB) digester (25.5m3) followed by an upflow anaerobic sludge blanket (UASB) digester (20.36m3). The hydraulic retention time (HRT) varied from 5.7 to 2.8h for the first stage (HUSB digester) and from 13.9 to 6.5h for the second stage (UASB digester). Total suspended solids (TSS), total chemical oxygen demand (TCOD), and biochemical oxygen demand (BOD) removals ranged from 76% to 89%, from 49% to 65%, and from 50% to 77%, respectively, for the overall system. The percentage of influent COD converted to methane was 36.1%, the hydrolysis of influent volatile suspended solids (VSS) reached 59.7% and excess biomass was 21.6% of the incoming VSS. Plant performance was influenced by the wastewater concentration and temperature, yet better results were obtained for influent COD higher than 250mg/l.  相似文献   

18.
A study of the anaerobic digestion of wastewater derived from the production of protein isolates from extracted sunflower flour was carried out in a laboratory-scale, mesophilic (35 degrees C) fluidized-bed reactor with saponite as bacterial support. Chemical oxygen demand (COD) removal efficiencies in the range of 98.3-80.0% were achieved in the reactor at organic loading rates (OLR) of between 0.6 and 9.3 g COD/I d, hydraulic retention times (HRT) of between 20.0 and 1.1 d and average feed COD concentration of 10.6 g/l. Eighty percent of feed COD could be removed up to OLR of 9.3 g COD/l d. The yield coefficient of methane production was 0.33 l of methane (at STP) per gram of COD removed and was virtually independent of the OLR applied. Because the buffering capacity of the experimental system was maintained at favorable levels with excess total alkalinity present at all loadings, the rate of methanogenesis was not affected by loading. The experimental data indicated that a total alkalinity in the range of 2,000-2,460 mg/l as CaCO3 was sufficient to prevent the pH from dropping to below 7.0 for OLR of up to 9.3 g COD/l d. The volatile fatty acid (VFA) levels and the VFA/alkalinity ratio were lower than the suggested limits for digester failure (0.3-0.4) for OLR and HRT up to 9.3 g COD/l d and 1.1 d, respectively. For a HRT of 0.87 d (OLR of 12.1 g COD/l d) the start of acidification was observed in the reactor.  相似文献   

19.
A lab-scale investigation was conducted to examine the effectiveness of a multi-fed upflow anaerobic filter process for the methane production from a rice winery effluent at ambient temperatures. The experiment was carried in two identical 3.0-l upflow filters, a single-fed reactor and a multi-fed reactor. The results showed that the multi-fed reactor, operated at the ambient temperatures of 19–27 °C and influent chemical oxygen demand (COD) of 8.34–25.76 g/l, could remove over 82% of COD even at an organic loading rate (OLR) of 37.68 g-COD/l d and a short hydraulic retention time (HRT) of 8 h. This reactor produced biogas with a methane yield of 0.30–0.35 l-CH4/g-CODremoved. The multi-fed upflow anaerobic filter was proved to be more efficient than the single-fed reactor in terms of COD removal efficiency and stability against hydraulic loading shocks. A linear-regression model with influent COD concentration and HRT terms adequately described the multi-fed upflow anaerobic filter system for the treatment of rice winery wastewater at ambient temperatures.  相似文献   

20.
Shao X  Peng D  Teng Z  Ju X 《Bioresource technology》2008,99(8):3182-3186
Brewery wastewater was treated in a pilot-scale anaerobic sequencing batch reactor (ASBR) in which a floating cover(@) was employed. Long time experiments showed that the reactor worked stably and effectively for COD removal and gas production. When the organic loading rate was controlled between 1.5 kg COD/m3 d and 5.0 kg COD/m(3)d, and hydraulic retention time one day, COD removal efficiency could reach more than 90%. Sludge granulation was achieved in the reactor in approximately 60 days, which is much less than the granulation time ever reported. In addition, high specific methanogenic activity (SMA) for formate was observed. The study suggests that the ASBR technology is a potential alternative for brewery wastewater treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号