首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
It is not currently known how the mechanical properties of human tendons change with maturation in the two sexes. To address this, the stiffness and Young's modulus of the patellar tendon were measured in men, women, boys and girls (each group, n=10). Patellar tendon force (Fpt) was calculated from the measured joint moment during a ramped voluntary isometric knee extension contraction, the antagonist knee extensor muscle co-activation quantified from its electromyographical activity, and the patellar tendon moment arm measured from magnetic resonance images. Tendon elongation was imaged using the sagittal-plane ultrasound scans throughout the contraction. Tendon cross-sectional area was measured at rest from ultrasound scans in the transverse plane. Maximal Fpt and tendon elongation were (mean±SE) 5453±307 N and 5±0.5 mm for men, 3877±307 N and 4.9±0.6 mm for women, 2017±170 N and 6.2±0.5 mm for boys and 2169±182 N and 5.9±0.7 mm for girls. In all groups, tendon stiffness and Young's modulus were examined at the level that corresponded to the maximal 30% of the weakest participant's Fpt and stress, respectively; these were 925–1321 N and 11.5–16.5 MPa, respectively. Stiffness was 94% greater in men than boys and 84% greater in women than girls (p<0.01), with no differences between men and women, or boys and girls (men 1076±87 N/mm; women 1030±139 N/mm; boys 555±71 N/mm and girls 561.5±57.4 N/mm). Young's modulus was 99% greater in men than boys (p<0.01), and 66% greater in women than girls (p<0.05). There were no differences in modulus between men and women, or boys and girls (men 597±49 MPa; women 549±70 MPa; boys 255±42 MPa and girls 302±33 MPa). These findings indicate that the mechanical stiffness of tendon increases with maturation due to an increased Young's modulus and, in females due to a greater increase in tendon cross-sectional area than tendon length.  相似文献   

2.
Ectopic tendon mineralization can develop following tendon rupture or trauma surgery. The pathogenesis of ectopic tendon mineralization and its clinical impact have not been fully elucidated yet. In this study, we utilized a mouse Achilles tendon injury model to determine whether ectopic tendon mineralization alters the biomechanical properties of the tendon and whether BMP signaling is involved in this condition. A complete transverse incision was made at the midpoint of the right Achilles tendon in 8-week-old CD1 mice and the gap was left open. Ectopic cartilaginous mass formation was found in the injured tendon by 4 weeks post-surgery and ectopic mineralization was detected at 8 to 10 weeks post-surgery. Ectopic mineralization grew over time and volume of the mineralized materials of 25-weeks samples was about 2.5 fold bigger than that of 10-weeks samples, indicating that injury-induced ectopic tendon mineralization is progressive. In vitro mechanical testing showed that max force, max stress and mid-substance modulus in the 25-weeks samples were significantly lower than the 10-weeks samples. We observed substantial increases in expression of bone morphogenetic protein family genes in injured tendons 1 week post-surgery. Immunohistochemical analysis showed that phosphorylation of both Smad1 and Smad3 was highly increased in injured tendons as early as 1 week post-injury and remained high in ectopic chondrogenic lesions 4-weeks post-injury. Treatment with the BMP receptor kinase inhibitor (LDN193189) significantly inhibited injury-induced tendon mineralization. These findings indicate that injury-induced ectopic tendon mineralization is progressive, involves BMP signaling and associated with deterioration of tendon biomechanical properties.  相似文献   

3.
In order to maintain their native properties, cryopreserved tendons are usually used in biomechanical research and in transplantation of allogenic tendon grafts. The use of different study protocols leads to controversy in literature and thus complicates the evaluation of the current literature. The aim of this study consisted in examining the influence of different freezing and thawing temperatures on the mechanical properties of tendons. 60 porcine tendons were frozen at either −80 °C or −20 °C for 7 days and thawed at room or body temperature for 240 or 30 min, respectively. A subgroup of ten tendons was quick-frozen with liquid nitrogen (−196 °C) for 2 s before cryopreservation. Biomechanical testing was performed with a material testing machine and included creep, cyclic and load-to-failure tests. The results showed that freezing leads to a reduced creep strain after constant loading and to an increased secant modulus. Freezing temperature of −80 °C increased the secant modulus and decreased the strain at maximum stress, whereas thawing at room temperature reduced the maximum stress, the strain at initial tendon failure and the Young’s Modulus. Quick-freezing led to increased creep strain after constant loading, increased strain at initial failure in the load-to-failure test, and decreased strain at maximum stress. When cryopreserving, tendons for scientific or medical reasons, freezing temperature of −20 °C and thawing temperature of 37.5 °C are recommended to maintain the native properties of tendons. A treatment with liquid nitrogen in the sterilization process of tendon allografts is inadvisable because it alters the tendon properties negatively.  相似文献   

4.
The objectives of this study was to investigate the acute effects of various magnitudes of tendon strain on the mechanical properties of the human medial gastrocnemius (MG) in vivo during controlled heel-drop exercises. Seven male and seven female volunteers performed two different exercises executed one month apart: one was a heel-drop exercise on a block (HDB), and the other was a heel-drop exercise on level floor (HDL). In each regimen, the subjects completed a session of 150 heel-drop exercises (15 repetitions × 10 sets; with a 30 s rest following each set). Before and immediately after the heel-drop exercise, the ankle plantar flexor torque and elongation of the MG were measured using a combined measurement system of dynamometry and ultrasonography and then the MG tendon strain and stiffness were evaluated in each subject. The tendon stiffness measured prior to the exercises was not significantly different between the two groups 23.7 ± 10.6 N/mm and 24.1 ± 10.0 N/mm for the HDB and HDL, respectively (p > .05). During the heel-drop exercise, it was found that the tendon strain during the heel-drop exercise on a block (8.4 ± 3.7%) was significantly higher than the strain measured on the level floor (5.4 ± 3.8%) (p < .05). In addition, the tendon stiffness following the heel-drop exercise on a block (32.3 ± 12.2 N/mm) was significantly greater than the tendon stiffness measured following the heel-drop exercise on the level floor (25.4 ± 11.4 N/mm) (p < .05). The results of this study suggest that tendon stiffness immediately following a heel-drop exercise depends on the magnitude of tendon strain.  相似文献   

5.
In early stages of tendon disease, mechanical properties may become altered prior to changes in morphological anatomy. Ultrashort echo time (UTE) magnetic resonance imaging (MRI) can be used to directly detect signal from tissues with very short T2 values, including unique viscoelastic tissues such as tendons. The purpose of this study was to use UTE sequences to measure T21, T1 and magnetization transfer ratio (MTR) variations of tendon samples under static tensile loads. Six human peroneal tendons were imaged before and under static loading using UTE sequences on a clinical 3 T MRI scanner. Tendons were divided into two static tensile loading groups: group A that underwent one-step loading (15 N) and group B that underwent two-step loading (15 and 30 N). The T21, T1 and MTR variations were investigated in two selected section regions of interest (ROIs), including whole and core sections. Mean T21 values for the first step of loading (groups A and B) in both whole section and core section ROIs were significantly decreased by 13 ± 7% (P = 0.028) and 16 ± 5% (P = 0.017), respectively. For the second loading step (group B), there was a consistent, but non-significant reduction in T21 value by 9 ± 2% (P = 0.059) and 7 ± 5% (P = 0.121) for whole and core sections, respectively. Mean T1 did not show any consistent changes for either loading steps (P > 0.05). Mean MTR increased slightly, but not significantly for both loading steps (P > 0.05). Significant differences were found only in T21 values of tendons by static tensile load application. Therefore, T21 monitoring during loading is suggested for quantitative investigation of the tendons biomechanics.  相似文献   

6.
This study used subject-specific measures of three-dimensional (3D) free Achilles tendon geometry in conjunction with a finite element method to investigate the effect of variation in subject-specific geometry and subject-specific material properties on tendon stress during submaximal isometric loading. Achilles tendons of eight participants (Aged 25–35 years) were scanned with freehand 3D ultrasound at rest and during a 70% maximum voluntary isometric contraction. Ultrasound images were segmented, volume rendered and transformed into subject-specific 3D finite element meshes. The mean (±SD) lengths, volumes and cross-sectional areas of the tendons at rest were 62 ± 13 mm, 3617 ± 984 mm3 and 58 ± 11 mm2 respectively. The measured tendon strain at 70% MVIC was 5.9 ± 1.3%. Subject-specific material properties were obtained using an optimisation approach that minimised the difference between measured and modelled longitudinal free tendon strain. Generic geometry was represented by the average mesh and generic material properties were taken from the literature. Local stresses were subsequently computed for combinations of subject-specific and generic geometry and material properties. For a given geometry, changing from generic to subject-specific material properties had little effect on the stress distribution in the tendon. In contrast, changing from generic to subject-specific geometry had a 26-fold greater effect on tendon stress distribution. Overall, these findings indicate that the stress distribution experienced by the living free Achilles tendon of a young and healthy population during voluntary loading are more sensitive to variation in tendon geometry than variation in tendon material properties.  相似文献   

7.
In this study the influence of the grip position (crimp grip vs. slope grip position) on the pulley system of the finger was investigated. For this purpose 21 cadaver finger (11 hands, 10 donors) were fixed into an isokinetic loading device. Nine fingers were loaded in the slope grip position and 12 fingers in the crimp grip position. The forces in the flexor tendons and at the fingertip were recorded. A rupture of the A4 pulley occurred most often in the crimp grip position (50%) but did not occur in the slope grip position, in which alternative events were the most common (67%). The forces in the deep flexor tendon (FDP) (slope grip: 371 N, crimp grip: 348 N) and at the fingertip (slope grip: 105 N, crimp grip: 161 N) were not significantly different between the 2 finger positions, but the forces acting on the pulleys were higher in the crimp grip position (A2 pulley: 287 N, A4 pulley: 226 N) than in the slope grip position (A2 pulley: 121 N, A4 pulley: 103 N). The crimp grip position may be the main cause for A4 pulley ruptures but the slope grip position may be hazardous for other injuries as the forces recorded in the flexor tendons and at the fingertip were comparable at the occurrence of a terminal event.  相似文献   

8.
The present study investigated the effects of submaximal sustained and maximal repetitive contractions on the compliance of human vastus lateralis (VL) tendon and aponeurosis in vivo using two different fatiguing protocols. Twelve male subjects performed three maximum voluntary isometric contractions (MVC) of the knee extensors before and after two fatiguing protocols on a dynamometer. The first fatiguing protocol consisted of a long-lasting sustained isometric knee extension contraction at 25% MVC until failure (inability to hold the defined load). The second fatiguing protocol included long-lasting isokinetic (90°/s) knee extension contractions, where maximum moment was exerted and failure was proclaimed when this value fell below 70% of unfatigued maximum isokinetic moment. Ultrasonography was used to determine the elongation and strain of the VL tendon and aponeurosis. Muscle fatigue was indicated by a significant decrease in maximum resultant knee extension moment (p < 0.05) observed during the MVCs after both long-lasting contractions. No significant (p > 0.05) differences in elongation and strain of the VL tendon and aponeurosis were found, when compared every 300 N (tendon force) before and after the fatiguing protocols. The present data indicate, that the VL tendon and aponeurosis in vivo do not suffer from changes in the compliance neither after long-lasting static mechanical loading (strain ~3.2%) nor after long-lasting cyclic mechanical loading (strain 6.2–5.5%).  相似文献   

9.
Conservative treatment (non-operative) of Achilles tendon ruptures is suggested to produce equivalent capacity for return to function; however, long term results and the role of return to activity (RTA) for this treatment paradigm remain unclear. Therefore, the objective of this study was to evaluate the long term response of conservatively treated Achilles tendons in rodents with varied RTA. Sprague Dawley rats (n = 32) received unilateral blunt transection of the Achilles tendon followed by randomization into groups that returned to activity after 1-week (RTA1) or 3-weeks (RTA3) of limb casting in plantarflexion, before being euthanized at 16-weeks post-injury. Uninjured age-matched control animals were used as a control group (n = 10). Limb function, passive joint mechanics, tendon properties (mechanical, histological), and muscle properties (histological, immunohistochemical) were evaluated. Results showed that although hindlimb ground reaction forces and range of motion returned to baseline levels by 16-weeks post-injury regardless of RTA, ankle joint stiffness remained altered. RTA1 and RTA3 groups both exhibited no differences in fatigue properties; however, the secant modulus, hysteresis, and laxity were inferior compared to uninjured age-matched control tendons. Despite these changes, tendons 16-weeks post-injury achieved secant stiffness levels of uninjured tendons. RTA1 and RTA3 groups had no differences in histological properties, but had higher cell numbers compared to control tendons. No changes in gastrocnemius fiber size or type in the superficial or deep regions were detected, except for type 2x fiber fraction. Together, this work highlights RTA-dependent deficits in limb function and tissue-level properties in long-term Achilles tendon and muscle healing.  相似文献   

10.
The purpose of the current study in combination with our previous published data (Arampatzis et al., 2007) was to examine the effects of a controlled modulation of strain magnitude and strain frequency applied to the Achilles tendon on the plasticity of tendon mechanical and morphological properties. Eleven male adults (23.9±2.2 yr) participated in the study. The participants exercised one leg at low magnitude tendon strain (2.97±0.47%), and the other leg at high tendon strain magnitude (4.72±1.08%) of similar frequency (0.5 Hz, 1 s loading, 1 s relaxation) and exercise volume (integral of the plantar flexion moment over time) for 14 weeks, 4 days per week, 5 sets per session. The exercise volume was similar to the intervention of our earlier study (0.17 Hz frequency; 3 s loading, 3 s relaxation) allowing a direct comparison of the results. Before and after the intervention ankle joint moment has been measured by a dynamometer, tendon–aponeurosis elongation by ultrasound and cross-sectional area of the Achilles tendon by magnet resonance images (MRI). We found a decrease in strain at a given tendon force, an increase in tendon–aponeurosis stiffness and tendon elastic modulus of the Achilles tendon only in the leg exercised at high strain magnitude. The cross-sectional area (CSA) of the Achilles tendon did not show any statistically significant (P>0.05) differences to the pre-exercise values in both legs. The results indicate a superior improvement in tendon properties (stiffness, elastic modulus and CSA) at the low frequency (0.17 Hz) compared to the high strain frequency (0.5 Hz) protocol. These findings provide evidence that the strain magnitude applied to the Achilles tendon should exceed the value, which occurs during habitual activities to trigger adaptational effects and that higher tendon strain duration per contraction leads to superior tendon adaptational responses.  相似文献   

11.
Background: Previous literature has shown in vivo changes in muscle-tendon interaction during exhaustive stretch-shortening cycle (SSC) exercise. It is unclear whether these changes in muscle-tendon length during exhaustive SSC exercise are associated with changes in mechanical efficiency (ME). The purpose of the study was to investigate whether changes in platarflexor contractile component (CC) length, tendon length, and changes in plantarflexor muscle activity could explain reduction in ME during exhaustive SSC exercise. Methods: Eight males participated in an exhaustive hopping task to fatigue. Mechanical work and energy expenditure were calculated at different time-points during the hopping task. Furthermore, hopping kinetics and kinematics, medial gastrocnemius (MG) muscle activity, and in vivo ultrasound of the MG were also collected at different time-points throughout the hopping task. Results: ME did not change during the hopping protocol despite shorter tendon and longer CC lengths as subjects approached exhaustion. Percent decreases in pennation angle and muscle thickness were most strongly correlated to time to exhaustion (r = 0.94, p  0.05; r = 0.87, p  0.05; respectively). Percent changes in CC length change and pennation angle were strongly correlated to percent decrease in maximal voluntary isometric plantarflexion (MVIP) force (r = −0.71, p  0.04; r = 0.70, p  0.05; respectively). Braking/push-off EMG ratio increased from initial pre-fatigue values to all other time points showing neuromuscular adaptations to altered muscle lengths. Conclusion: Findings from the current study suggest that changes in CC and tendon lengths occur during repetitive hopping to exhaustion, with the amount change strongly related to time to exhaustion. ME of hopping remained unchanged in the presence of altered CC and tendon lengths.  相似文献   

12.
13.
The purpose of this study was to quantify strain and elongation of the long head of the biceps femoris (BFlh) and the semitendinosus (ST) tendon/aponeurosis. Forty participants performed passive knee extension trials from 90° of knee flexion to full extension (0°) followed by ramp isometric contractions of the knee flexors at 0°, 45° and 90° of knee flexion. Two ultrasound probes were used to visualize the displacement of BFlh and ST tendon/aponeurosis. Three-way analysis of variance designs indicated that: (a) Tendon/aponeurosis (passive) elongation and strain were higher for the BFlh than the ST as the knee was passively extended (p < 0.05), (b) contraction at each angular position was accompanied by a smaller BFlh tendon/aponeurosis (active) strain and elongation than the ST at higher levels of effort (p < 0.05) and (c) combined (passive and active) strain was significantly higher for the BFlh than ST during ramp contraction at 0° but the opposite was observed for the 45° and 90° flexion angle tests (p < 0.05). Passive elongation of tendon/aponeurosis has an important effect on the tendon/aponeurosis behavior of the hamstrings and may contribute to a different loading of muscle fibers and tendinous tissue between BFlh and ST.  相似文献   

14.
Decellularised porcine super flexor tendon (pSFT) offers a promising solution to the replacement of damaged anterior cruciate ligament. It is desirable to package and terminally sterilise the acellular grafts to eliminate any possible harmful pathogens. However, irradiation techniques can damage the collagen structure and consequently reduce the mechanical properties. The aims of this study were to investigate the effects of irradiation sterilisation of varying dosages on the viscoelastic properties of the decellularised pSFT.Decellularised pSFT tendons were subjected to irradiation sterilisation using either 30 kGy gamma, 55 kGy gamma, 34 kGy E-beam, 15 kGy gamma, 15 kGy E-beam and (15 + 15) kGy E-beam (fractionated dose). Specimens then underwent stress relaxation testing at 0 and 12 months post sterilisation to determine whether any effect on the viscoelastic properties was progressive.Significant differences were found which demonstrated that all irradiation treatments had an effect on the time-independent and time-dependent viscoelastic properties of irradiated tendons compared to peracetic acid only treated controls. No significant differences were found between the irradiated groups and no significant differences were found between groups at 0 and 12 months. These results indicate the decellularised pSFT graft has a stable shelf-life.  相似文献   

15.
Kinesthetic illusions by visual stimulation (KiNVIS) enhances corticomotor excitability and activates motor association areas. The purpose of this study was to investigate the effect of KiNVIS induction on muscular output function after short-term immobilization. Thirty subjects were assigned to 3 groups: an immobilization group, with the left hand immobilized for 12 h (immobilization period); an illusion group, with the left hand immobilized and additionally subjected to KiNVIS of the immobilized part during the immobilization period; and a control group with no manipulation. The maximum voluntary contraction (MVC), fluctuation of force (force fluctuation) during a force modulation task, and twitch force were measured both before (pre-test) and after (post-test) the immobilization period. Data were analyzed by performing two-way (TIME × GROUP) repeated measures ANOVA. The MVC decreased in the immobilization group only (pre-test; 37.8 ± 6.1 N, post-test; 32.8 ± 6.9 N, p < 0.0005) after the immobilization period. The force fluctuation increased only in the immobilization group (pre-test; 2.19 ± 0.54%, post-test; 2.78 ± 0.87%, p = 0.007) after the immobilization period. These results demonstrate that induction of KiNVIS prevents negative effect on MVC and force fluctuation after 12 h of immobilization.  相似文献   

16.
This study examined correlations between type I percent myosin heavy chain isoform content (%MHC) and mechanomyographic amplitude (MMGRMS) during isometric muscle actions. Fifteen (age = 21.63 ± 2.39) participants performed 40% and 70% maximal voluntary contractions (MVC) of the leg extensors that included increasing, steady force, and decreasing segments. Muscle biopsies were collected and MMG was recorded from the vastus lateralis. Linear regressions were fit to the natural-log transformed MMGRMS–force relationships (increasing and decreasing segments) and MMGRMS was selected at the targeted force level during the steady force segment. Correlations were calculated among type I%MHC and the b (slopes) terms from the MMGRMS–force relationships and MMGRMS at the targeted force. For the 40% MVC, correlations were significant (P < 0.02) between type I%MHC and the b terms from the increasing (r = −0.804) and decreasing (r = −0.568) segments, and MMGRMS from the steady force segment (r = −0.606). Type I%MHC was only correlated with MMGRMS during the steady force segment (P = 0.044, r = −0.525) during the 70% MVC. Higher type I%MHC reduced acceleration in MMGRMS (b terms) during the 40% MVC and the amplitude during the steady force segments. The surface MMG signal recorded during a moderate intensity contraction provided insight on the contractile properties of the VL in vivo.  相似文献   

17.
ObjectiveTo evaluate the electromyographic activity of the Pectoralis Major (PM), Biceps Brachii (BB), Pronator Teres (PT) and Flexor Carpi Ulnaris (FCU) muscles involved in simulated armwrestling.MethodsTen trained volunteers were selected to perform the armwrestling movement, during dynamic tests with 40% and 80% of maximum voluntary load (MVL) and static tests in the initial, intermediary and final positions. Electromyographic and force data were normalized for analyses.ResultsIn dynamic tests with 40% MVL, electric activity of the PT muscle was greater than FCU (p < 0.01) and BB (p < 0.05) muscles, and with 80% MVL, PM and PT muscles were the most active. In static tests, electric activity increased from the initial to final positions for the PM muscle (p < 0.05), while it decreased for the BB and PT muscles (p < 0.001 and p < 0.05, respectively). No significant changes were observed for force and no correlation was found with the simultaneous electric activity.ConclusionsIt can be concluded that the PM and FCU muscles participate as agonists in the simulated armwrestling whereas the BB and PT muscles seem to perform secondary functions. Electric activity showed to be dependent on the load and on the position of the upper limb, but not on the force produced during the movement.  相似文献   

18.
19.
The aim of this study was to determine the effects of anterior cruciate ligament reconstruction (ACLR) on sub-maximal quadriceps force control with respect to quadriceps and hamstring muscle activity. Thirty ACLR individuals together with 30 healthy individuals participated. With real-time visual feedback of muscle force output and electromyographic electrodes attached to the quadriceps and hamstring muscles, subjects performed an isometric knee extension task where they increased and decreased their muscle force output at 0.128 Hz within a range of 5–30% maximum voluntary capacity. The ACLR group completed the task with more error and increased medial hamstring and vastus medialis activation (p < 0.05). Moderate negative correlations (p < 0.05) were observed between quadriceps force control and medial (Spearman’s rho = −0.448, p = 0.022) and lateral (Spearman’s rho = −0.401, p = 0.034) hamstring activation in the ACLR group. Diminished quadriceps sub-maximal force control in ACLR subjects was reflective of medial quadriceps and hamstring dyskinesia (i.e., altered muscle activity patterns and coordination deficits). Within the ACLR group however, augmented hamstring co-activation was associated with better quadriceps force control. Future studies should explore the convergent validity of quadriceps force control in ACLR patients.  相似文献   

20.
Temperature effects on the viscoelastic properties of the human supraspinatus tendon were investigated using static stress-relaxation experiments and the quasi-linear viscoelastic (QLV) theory. Twelve supraspinatus tendons were randomly assigned to one of two test groups for tensile testing using the following sequence of temperatures: (1) 37, 27, and 17 °C (Group I, n=6), or (2) 42, 32, and 22 °C (Group II, n=6). QLV parameter C was found to increase at elevated temperatures, suggesting greater viscous mechanical behavior at higher temperatures. Elastic parameters A and B showed no significant difference among the six temperatures studied, implying that the viscoelastic stress response of the supraspinatus tendon is not sensitive to temperature over shorter testing durations. Using regression analysis, an exponential relationship between parameter C and test temperature was implemented into QLV theory to model temperature-dependent viscoelastic behavior. This modified approach facilitates the theoretical determination of the viscoelastic behavior of tendons at arbitrary temperatures.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号