首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The microalgal species Chlorella pyrenoidosa was cultivated in synthetic wastewater of initial chemical oxygen demand (COD), nitrate, and phosphate concentrations of 5000, 100, and 40 mg/L, respectively. The aim of the study was to find out the tolerance of microalgae to different COD concentrations and the extent of COD degradation at those concentrations. Three dilutions of wastewater (initial COD concentrations 5000, 3000, and 1000 mg/L) and three inoculum sizes (0.1, 0.2, and 0.3 g/L) were considered for the study. The experimental parameters such as total organic carbon, total inorganic carbon, COD, optical density, total solids, nitrate, and phosphate were measured on a daily basis. Biodegradation kinetics was determined for all cases using first-order reaction and Monod degradation equations. Optimal results showed that up to 90% reduction in TOC was obtained for 1000 COD wastewater while only 38% reduction in total organic carbon (TOC) was achieved for 5000 COD wastewater. Over 95% reduction in nitrate and nearly 90% removal of phosphate were obtained with the lowest microalgal inoculum concentration (i.e., 0.1 g/L) for all COD dilutions. This study showed that microalgal species C. pyrenoidosa can successfully degrade the organic carbon source (i.e., acetate) with significant removal efficiencies for nitrate and phosphate.  相似文献   

2.
The main aim of this study is to investigate the performance of organic oxidation and denitrification of the system under long-term operation. The MFC reactor was operated in continuous mode for 180 days. Nitrate was successfully demonstrated as terminal electron acceptor, where nitrate was reduced at the cathode using electron provided by acetate oxidation at the anode. The removal efficiencies of chemical oxygen demand (COD) and nitrate were higher in the closed circuit system than in open circuit system. Both COD and nitrate reduction improved with the increase of organic loading and subsequently contributed to higher power output. The maximum nitrate removal efficiency was 88 ± 4 % (influent of 141 ± 14 mg/L). The internal resistant was 50 Ω, which was found to be low for a double chambered MFC. The maximum power density was 669 mW/m3 with current density of 3487 mA/m3.  相似文献   

3.
Bruguiera gymnorhiza, an evergreen mangrove tree, is tolerant of bisphenol A (BPA) and has potential BPA removal capability. BPA is highly toxic to plants at high concentrations, wherein they exhibit damaged symptoms such as chlorosis, necrosis, and wilting. The LD50 of BPA toxicity for this plant was statistically estimated to be 39.97 mg L–1. B. gymnorhiza can reduce COD from 15408 ± 246 to 49 ± 30 mg L–1 by (approximately 99% reduction of the initial value) and can reduce content to levels below the industrial effluent standard of Thailand (<120 mg L–1) within 48 days. This plant can completely remove BPA from the solution within 51 days of treatment. Polysaccharides and organic acids were found in the solution and were caused by plant response to the toxicity of BPA. In addition, B. gymnorrhiza can also reduce total dissolved solids (TDS) and salinity in real wastewater. Therefore, B. gymnorrhiza has potential for removal of BPA and TDS in contaminated in wastewater.  相似文献   

4.
Pilot-scale constructed wetlands (CW) were constructed and operated to treat pre-treated olive mill wastewater. Pilot-scale units comprising three identical series with four pilot-scale vertical flow CWs were operated for one harvest season in a Greek olive mill plant. The pilot-scale CWs were filled with various porous media (i.e., cobble, gravel, and sand) of different gradations. Two series of pilot-scale units were planted with common reeds and the third (control) was unplanted. Mean influent concentrations were 14,120 mg/L, 2841 mg/L, 95 mg/L, 123 mg/L and 506 mg/L for COD, phenols, ortho-phosphate, ammonia and TKN, respectively. Despite the rather high influent concentrations, the performance of the CW units was very effective since it achieved removals of about 70%, 70%, 75% and 87% for COD, phenols, TKN and ortho-phosphate, respectively. COD, phenol and TKN removal seems to be significantly higher in the planted series, while ortho-phosphate removal shows no significant differences among the three series. Temperature and pollutant surface load seem to affect the removal efficiency of all pollutants. Compared to previous studies, pollutant surface loads applied here were higher (by one or two orders of magnitude). Even though high removal efficiencies were achieved, effluent pollutant concentrations remained high, thus preventing their use for irrigation or immediate disposal into the environment.  相似文献   

5.
This paper elucidates the phytoremediation potential of water hyacinth and water lettuce on the reduction of wastewater toxicity. Acute toxicity tests were performed in an aquarium with a population of Sarotherodon melanotheron, contaminated by different concentrations of wastewaters before and after phytoremediation with Eichhornia crassipes and Pistia stratiotes. Lethal concentrations (LC50) of the fish's population obtained during 24 hours of exposures were determined. COD, BOD, ammonium, TKN and PO43? concentrations in wastewaters were of 1850.29, 973.33, 38.34, 61.49 and 39.23 mg L?1, respectively, for each plant. Phytoremediation reduced 58.87% of ammonium content, 50.04% of PO43?, 82.45% of COD and 84.91% of BOD. After 15 days of the experiment, metal contents in treated wastewaters decreased from 6.65 to 97.56% for water hyacinth and 3.51 to 93.51% for water lettuce tanks. Toxicity tests showed that the mortality of fish exposed increased with increase in concentration of pollutants in wastewaters and the time of exposure. Therefore, the highest value of LC50 was recorded for fish subjected to 3 hours of exposure (16.37%). The lowest rate was obtained after an exposure of 20 to 24 hours (5.85%). After phytoremediation, the effluents purified by Eichhornia crassipes can maintain the fish life beyond 24 hours of exposure.  相似文献   

6.
Treatment of domestic wastewater using microbial fuel cells (MFCs) will require reactors with multiple electrodes, but this presents unique challenges under continuous flow conditions due to large changes in the chemical oxygen demand (COD) concentration within the reactor. Domestic wastewater treatment was examined using a single-chamber MFC (130 mL) with multiple graphite fiber brush anodes wired together and a single air cathode (cathode specific area of 27 m2/m3). In fed-batch operation, where the COD concentration was spatially uniform in the reactor but changed over time, the maximum current density was 148?±?8 mA/m2 (1,000 Ω), the maximum power density was 120 mW/m2, and the overall COD removal was >90 %. However, in continuous flow operation (8 h hydraulic retention time, HRT), there was a 57 % change in the COD concentration across the reactor (influent versus effluent) and the current density was only 20?±?13 mA/m2. Two approaches were used to increase performance under continuous flow conditions. First, the anodes were separately wired to the cathode, which increased the current density to 55?±?15 mA/m2. Second, two MFCs were hydraulically connected in series (each with half the original HRT) to avoid large changes in COD among the anodes in the same reactor. The second approach improved current density to 73?±?13 mA/m2. These results show that current generation from wastewaters in MFCs with multiple anodes, under continuous flow conditions, can be improved using multiple reactors in series, as this minimizes changes in COD in each reactor.  相似文献   

7.
Edible oil industry produced massive wastewater, which requires extensive treatment to remove pungent smell, high phosphate, carbon oxygen demand (COD), and metal ions prior to discharge. Traditional anaerobic and aerobic digestion could mainly reduce COD of the wastewater from oil refinery factories (WEORF). In this study, a robust oleaginous microalga Desmodesmus sp. S1 was adapted to grow in WEORF. The biomass and lipid content of Desmodesmus sp. S1 cultivated in the WEORF supplemented with sodium nitrate were 5.62 g·L?1 and 14.49%, whereas those in the WEORF without adding nitrate were 2.98 g·L?1 and 21.95%. More than 82% of the COD and 53% of total phosphorous were removed by Desmodesmus sp. S1. In addition, metal ions, including ferric, aluminum, manganese and zinc were also diminished significantly in the WEORF after microalgal growth, and pungent smell vanished as well. In comparison with the cells grown in BG-11 medium, the cilia-like bulges and wrinkles on the cell surface of Desmodesmus sp. S1 grown in WEORF became out of order, and more polyunsaturated fatty acids were detected due to stress derived from the wastewater. The study suggests that growing microalgae in WEORF can be applied for the dual roles of nutrient removal and biofuel feedstock production.  相似文献   

8.
The performance of an intermittently aerated sequencing batch reactor (IASBR) technology was investigated in achieving partial nitrification, organic matter removal and nitrogen removal from separated digestate liquid after anaerobic digestion of pig manure. The wastewater had chemical oxygen demand (COD) concentrations of 11,540 ± 860 mg/L, 5-day biochemical oxygen demand (BOD5) concentrations of 2,900 ± 200 mg/L and total nitrogen (TN) concentrations of 4,041 ± 59 mg/L, with low COD:N ratios (2.9) and BOD5:COD ratios (0.25). Synthetic wastewater, simulating the separated digestate liquid with similar COD and nitrogen concentrations but BOD5 of 11,500 ± 100 mg/L, was also treated using the IASBR technology. At a mean organic loading rate of 1.15 kg COD/(m3 d) and a nitrogen loading rate of 0.38 kg N/(m3 d), the COD removal efficiency was 89.8% in the IASBR (IASBR-1) treating digestate liquid and 99% in the IASBR (IASBR-2) treating synthetic wastewater. The IASBR-1 effluent COD was mainly due to inert organic matter and can be further reduced to less than 40 mg/L through coagulation. The partial nitrification efficiency of 71–79% was achieved in the two IASBRs and one cause for the stable long-term partial nitrification was the intermittent aeration strategy. Nitrogen removal efficiencies were 76.5 and 97% in IASBR-1 and IASBR-2, respectively. The high nitrogen removal efficiencies show that the IASBR technology is a promising technology for nitrogen removal from low COD:N ratio wastewaters. The nitrogen balance analysis shows that 59.4 and 74.3% of nitrogen removed was via heterotrophic denitrification in the non-aeration periods in IASBR-1 and IASBR-2, respectively.  相似文献   

9.
Effective wastewater treatment using microbial fuel cells (MFCs) will require a better understanding of how operational parameters and solution chemistry affect treatment efficiency, but few studies have examined power generation using actual wastewaters. The efficiency of wastewater treatment of a beer brewery wastewater was examined here in terms of maximum power densities, Coulombic efficiencies (CEs), and chemical oxygen demand (COD) removal as a function of temperature and wastewater strength. Decreasing the temperature from 30°C to 20°C reduced the maximum power density from 205 mW/m2 (5.1 W/m3, 0.76 A/m2; 30°C) to 170 mW/m2 (20°C). COD removals (R COD) and CEs decreased only slightly with temperature. The buffering capacity strongly affected reactor performance. The addition of a 50-mM phosphate buffer increased power output by 136% to 438 mW/m2, and 200 mM buffer increased power by 158% to 528 mW/m2. In the absence of salts (NaCl), maximum power output varied linearly with wastewater strength (84 to 2,240 mg COD/L) from 29 to 205 mW/m2. When NaCl was added to increase conductivity, power output followed a Monod-like relationship with wastewater strength. The maximum power (P max) increased in proportion to the solution conductivity, but the half-saturation constant was relatively unaffected and showed no correlation to solution conductivity. These results show that brewery wastewater can be effectively treated using MFCs, but that achievable power densities will depend on wastewater strength, solution conductivity, and buffering capacity.  相似文献   

10.
The effect of hydraulic loading rate (HLR) and hydraulic retention time (HRT) on the bioremediation of municipal wastewater using a pilot scale subsurface horizontal flow constructed treatment wetland (HFCTW) vegetated with Cyprus papyrus was investigated. Different HLRs were applied to the treatment system namely 0.18, 0.10, and 0.07 m3/m2. d with corresponding HRTs of 1.8, 3.2, and 4.7 days, respectively. The flow rate was 8 m3/d, and the average organic loading rate (OLR) was 0.037 kg BOD/m3/d. Results showed that the performance of the HFCTW was linearly affected by decreasing the HLR and increasing the HRT. The highest treatment efficiency was achieved at HRT (4.7 days) and HLR (0.07 m3/m2. d). The percentage reductions of chemical oxygen demand (COD), biochemical oxygen demand (BOD), and total suspended solids (TSS) were 86%, 87%, and 80%, respectively. Satisfactory nutrient removal was obtained. Also, removal of 2–3 logs of bacterial indicators of pollution was achieved. The dry biomass of Cyperus was 7.7 kg/m2 and proved to be very efficient in nitrification processes due to high diversity of the roots that increase the treatment surface area.  相似文献   

11.
Abstract

Laboratory-scale anaerobic-aerobic fluidized-bed bioreactors (FBR) with porous magnetic ceramics as support were successfully applied to treat purified terephthalic acid (PTA) wastewater. After a short 14-day start-up period, the system was stably operating. During the 40?d stable period, the system organic loading rate (OLR) increased from 6.68 to 23.87?kg chemical oxygen demand (COD)/(m3d), the effluent COD and PTA were below 90 and 30?mg/L, respectively. The FBR presented excellent COD and PTA removal efficiency with a low hydraulic retention time (HRT) value of six hours. The growth kinetic parameters suggested that the biomass in FBR possess high maximum specific growth rate (μmax?=?2.22?d?1) and good tolerance to varied OLR (Ks?=?258.67?mg COD/L).  相似文献   

12.
A pre-anoxic MBBR system was subjected to increasing organic loading rates up to 18 gCOD/(m2 day). At 3 gCOD/(m2 day), most of the incoming organic matter was removed via denitrification. However, at higher loads, anoxic COD removal became limited by the nitrite/nitrate supply from the aerobic reactor, which assumed an important role in this conversion. Despite the application of low dissolved oxygen (DO) levels (<2 mg/L) in this tank, nitrification was observed to be nearly complete until 8 gCOD/(m2 day). As the organic input was increased, the maximum specific nitrifying activity gradually declined. Activity tests suggested that an oxygen-limited environment was established in the biofilm. At lower loads [3–8 gCOD/(m2 day)], the nitrification product obtained was affected by the DO concentration, whereas from 16 to 21 gCOD/(m2 day), nitrite/nitrate profiles were likely associated with microbial stratification in the biofilm. The results also indicated that the role of the suspended biomass in the overall nitrification and denitrification can be very significant in high loaded MBBRs and should not be neglected, even at low HRTs.  相似文献   

13.
This paper reports the results obtained during an investigation aimed at transferring to the demonstrative scale an aerobic granular biomass system (SBBGR – Sequencing Batch Biofilter Granular Reactor) integrated with ozonation for the efficient treatment of tannery wastewater. The results show that the integrated process was able to achieve high removal efficiencies for COD, TSS, TKN, surfactants and colour with residual concentrations much lower than the current discharge limits. Furthermore, the process was characterised by a very low sludge production (i.e., 0.1 kg dry sludge/m3 of treated wastewater) with interesting repercussions on treatment costs (about 1 € per m3 of wastewater).  相似文献   

14.
15.
Addressing the need to recover energy from the treatment of domestic wastewater, a 120-L microbial electrolysis cell was operated on site in Northern England, using raw domestic wastewater to produce virtually pure hydrogen gas (100?±?6.4 %) for a period of over 3 months. The volumetric loading rate was 0.14 kg of chemical oxygen demand (COD) per cubic metre per day, just below the typical loading rates for activated sludge of 0.2–2 kg?COD?m?3?day?1, at an energetic cost of 2.3 kJ/g?COD, which is below the values for activated sludge 2.5–7.2 kJ/g?COD. The reactor produced an equivalent of 0.015 L?H2?L?1?day?1, and recovered around 70 % of the electrical energy input with a coulombic efficiency of 55 %. Although the reactor did not reach the breakeven point of 100 % electrical energy recovery and COD removal was limited, improved hydrogen capture and reactor design could increase the performance levels substantially. Importantly, for the first time, a ‘proof of concept’ has been made, showing that this technology is capable of energy capture as hydrogen gas from low strength domestic wastewaters at ambient temperatures.  相似文献   

16.
This study reports a comparative account of metal accumulation in the trees, grasses, and flowering plants from agricultural fields contaminated with tannery wastewater. Soil physico-chemical properties along the pollution gradient and soil depth were analyzed. Monitoring and assessment of the plants growing on contaminated sites revealed that the accumulation of Cr in the aboveground part of the trees ranged from 1.87 to 34.44 μg g?1 dw with maximum concentration in Dendro-calamus strictus (34.44 μg g?1 dw). Chrysanthemum coronarium and Tagetes erecta showed better accumulation of Cr than other flowering plants. Separate field experiments were conducted on the contaminated area. The shoots of Vetiveria zizanoides (532 mg 4 m?2) and Cymbopogan winterianus (535.46 mg 4 m?2) have shown almost similar removal potential of Cr, with maximum removal potential in the roots of C. winterianus (1206.43 mg 4 m?2). Seasonal flowering plants (i.e., C. coronarium) have shown better accumulation of Cr than T. erecta. The results indicate that the plants of V. zizanoides, C. coronarium, and C. winterianus are suitable for phytoremediation of contaminated sites and trees can successfully be used for phytostabilization.  相似文献   

17.
The purpose of this study is to evaluate the efficiency of hybrid constructed wetlands (HCWs) in a rural mountainous area. The experiment was set up in small rural community named Tidili within the region of Marrakech, Morocco. The wastewater treatment plant was composed of three vertical flow constructed wetlands (VFCWs) working in parallel, followed by two parallel horizontal-subsurface flow constructed wetlands (HFCWs), with hydraulic loading rates of 0.5 and 0.75 m3/m2.d, respectively. The two units were planted with Phragmites australis at a density of 4 plants/m2. Wastewater samples were collected at the inlet of the storage tank and at the outlet of the whole system (VFCWs, HFCWs) stages. The main removal percentages of total suspended solids (TSS), biochemical oxygen demand measured in a 5-day test (BOD5), chemical oxygen demand (COD), total nitrogen, and total phosphorus were respectively 95%, 93%, 91%, 67%, and 62%. The system showed a very high capacity to remove total coliforms, fecal coliforms, and fecal streptococci (4.46, 4.31, and 4.10 Log units, respectively). Artificial neural networks (ANNs) were used to model the quality parameters (TSS, BOD5, COD) and total coliforms and fecal streptococci. Based on the obtained results, the ANN model could be considered as an efficient tool to predict the studied phytoremediation performances using HCWs.  相似文献   

18.
Considering the diversity and the unexplored potential of regional aquatic flora, this study aimed to identify and analyze the potential of native aquatic macrophytes to reduce the organic matter of dairy wastewater (DW) using experimental constructed wetlands. The dairy wastewater (DW) had an average chemical oxygen demand (COD) of 7414.63 mg/L and then was diluted to 3133.16 mg/L (D1) and to 2506.53 mg/L (D2). Total solids, COD, temperature, and pH analyses were performed, and the biochemical oxygen demand (BOD) was estimated from the COD values. The best performance in the reduction of the organic matter was observed for Polygonum sp. (87.5% COD and 79.6% BOD) and Eichhornia paniculata (90% COD and 83.7% BOD) at dilution D1, on the 8th day of the experiment. However, the highest total solids removal was observed for Polygonum sp. (32.2%), on the 4th day, at dilution D2. The total solid (TS) concentration has also increased starting from the 8th day of the experiment was observed which may have been due to the development of mosquito larvae and their mechanical removal by sieving, thus changing the steady state of the experimental systems. The macrophytes Polygonum sp. and E. paniculata were considered suitable for the reduction of organic matter of DW using constructed wetlands.  相似文献   

19.
Wastewater of purified terephthalic acid (PTA) from a petrochemical plant was examined in a membrane-less single chamber microbial fuel cell for the first time. Time course of voltage during the cell operation cycle had two steady phases, which refers to the fact that metabolism of microorganisms was shifted from highly to less biodegradable carbon sources. The produced power density was 31.8 mW m?2 (normalized per cathode area) and the calculated coulombic efficiency was 2.05 % for a COD removal of 74 % during 21 days. The total removal rate of different pollutants in the PTA wastewater was observed in the following order: (acetic acid) > (benzoic acid) > (phthalic acid) > (terephthalic acid) > (p-toluic acid). The cyclic voltammetry results revealed that the electron transfer mechanism was dominated by mediators which were produced by bacteria.  相似文献   

20.
Two bed media were tested (gravel and Filtralite) in shallow horizontal subsurface flow (HSSF) constructed wetlands in order to evaluate the removal of ammonia and nitrate for different types of wastewater (acetate-based and domestic wastewater) and different COD/N ratios. The use of Filtralite allowed both higher mass removal rates (1.1 g NH4–N m−2 d−1 and 3 g NO3–N m−2 d−1) and removal efficiencies (>62% for ammonia, 90–100% for nitrate), in less than 2 weeks, when compared to the ones observed with gravel. The COD/N ratio seems to have no significant influence on nitrate removal and the removal of both ammonia and nitrate seems to have involved not only the conventional pathways of nitrification–denitrification. The nitrogen loading rate of both ammonia (0.8–2.4 g NH4–N m−2 d−1) and nitrate (0.6–3.2 g NO3–N m−2 d−1) seem to have influenced the respective removal rates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号