1.
It is clinically challenging to distinguish between ankle and subtalar joints instability in vivo. Understanding the changes in load-displacement at the ankle and subtalar joints after ligament injuries may detect specific changes in joint characteristics that cannot be detected by investigating changes in range of motion alone. The effect of restricting joints end range of motion with ankle braces was already established, but little is known about the effect of an ankle brace on the flexibility of the injured ankle and subtalar joints. Therefore, the purposes of this study were to (1) understand how flexibility is affected at the ankle and subtalar joints after sectioning lateral and intrinsic ligaments during combined sagittal foot position and inversion and during internal rotation and (2) investigate the effect of a semi-rigid ankle brace on the ankle and subtalar joint flexibility. Kinematics and kinetics were collected from nine cadaver feet during inversion through the range of ankle flexion and during internal rotation. Motion was applied with and without a brace on an intact foot and after sequentially sectioning the calcaneofibular ligament (CFL) and the intrinsic ligaments. Segmental flexibility was defined as the slope of the angle-moment curve for each 1 Nm interval. Early flexibility significantly increased at the ankle and subtalar joint after CFL sectioning during inversion. The semi-rigid ankle brace significantly decreased early flexibility at the subtalar joint during inversion and internal rotation for all ligament conditions and at the ankle joint after all ligaments were cut.  相似文献   

2.
3.
Understanding in vivo subtalar joint kinematics is important for evaluation of subtalar joint instability, the design of a subtalar prosthesis and for analysing surgical procedures of the ankle and hindfoot. No accurate data are available on the normal range of subtalar joint motion. The purpose of this study was to introduce a method that enables the quantification of the extremes of the range of motion of the subtalar joint in a loaded state using multidetector computed tomography (CT) imaging. In 20 subjects, an external load was applied to a footplate and forced the otherwise unconstrained foot in eight extreme positions. These extreme positions were foot dorsiflexion, plantarflexion, eversion, inversion and four extreme positions in between the before mentioned positions. CT images were acquired in a neutral foot position and each extreme position separately. After bone segmentation and contour matching of the CT data sets, the helical axes were determined for the motion of the calcaneus relative to the talus between four pairs of opposite extreme foot positions. The helical axis was represented in a coordinate system based on the geometric principal axes of the subjects’ talus. The greatest relative motion between the calcaneus and the talus was calculated for foot motion from extreme eversion to extreme inversion (mean rotation about the helical axis of 37.3±5.9°, mean translation of 2.3±1.1 mm). A consistent pattern of range of subtalar joint motion was found for motion of the foot with a considerable eversion and inversion component.  相似文献   

4.
The in-vitro, three dimensional kinematic characteristics of the human ankle and subtalar joint were investigated in this study. The main goals of this investigation were: 1) To determine the range of motion of the foot-shank complex and the associated range of motion of the ankle and subtalar joints; 2) To determine the kinematic coupling characteristics of the foot-shank complex, and 3) To identify the relationship between movements at the ankle and subtalar joints and the resulting motion produced between the foot and the shank. The tests were conducted on fifteen fresh amputated lower limbs and consisted of incrementally displacing the foot with respect to the shank while the motion of the articulating bones was measured through a three dimensional position data acquisition system. The kinematic analysis was based on the helical axis parameters describing the incremental displacements between any two of the three articulating bones and on a joint coordinate system used to describe the relative position between the bones. From the results of this investigation it was concluded that: 1) The range of motion of the foot-shank complex in any direction (dorsiflexion/plantarflexion, inversion/eversion and internal rotation/external rotation) is larger than that of either the ankle joint or the subtalar joint.; 2) Large kinematic coupling values are present at the foot-shank complex in inversion/eversion and in internal rotation/external rotation. However, only a slight amount of coupling was observed to occur in dorsiflexion/plantarflexion.; 3) Neither the ankle joint nor the subtalar joint are acting as ideal hinge joints with a fixed axis of rotation.; 4) Motion of the foot-shank complex in any direction is the result of rotations at both the ankle and the subtalar joints. However, the contribution of the ankle joint to dorsiflexion/plantarflexion of the foot-shank complex is larger than that of the subtalar joint and the contribution of the subtalar joint to inversion/eversion is larger than that of the ankle joint.; 5) The ankle and the subtalar joints have an approximately equal contribution to internal rotation/external rotation movements of the foot-shank complex.  相似文献   

5.
A technique to study the three-dimensional (3D) mechanical characteristics of the ankle and of the subtalar joints in vivo and in vitro is described. The technique uses an MR scanner compatible 3D positioning and loading linkage to load the hindfoot with precise loads while the foot is being scanned. 3D image processing algorithms are used to derive from the acquired MR images bone morphology, hindfoot architecture, and joint kinematics. The technique was employed to study these properties both in vitro and in vivo. The ankle and subtler joint motion and the changes in architecture produced in response to an inversion load and an anterior drawer load were evaluated. The technique was shown to provide reliable measures of bone morphology. The left-to-right variations in bone morphology were less than 5%. The left-to-right variations in unloaded hindfoot architecture parameters were less than 10%, and these properties were only slightly affected by inversion and anterior drawer loads. Inversion and anterior drawer loads produced motion both at the ankle and at the subtalar joint. In addition, high degree of coupling, primarily of internal rotation with inversion, was observed both at the ankle and at the subtalar joint. The in vitro motion produced in response to inversion and anterior drawer load was greater than the in vivo motion. Finally, external motion, measured directly across the ankle complex, produced in response to load was much greater than the bone movements measured through the 3D stress MRI technique indicating the significant effect of soft tissue and skin interference.  相似文献   

6.
Mobility of the subtalar joint in the intact ankle complex   总被引:8,自引:0,他引:8  
A previous study by these authors showed that the calcaneus follows a unique path of unresisted coupled motion relative to the tibia during passive flexion and that most of this motion occurred at the ankle level. Subtalar motion in the intact ankle complex was observed only when perturbations from this path were induced by the application of force to the calcaneus. Relative motion of the bones of the ankle complex was tracked by stereophotogrammetry in seven specimens. Anatomical landmarks, reference frames and joint angles were defined by standard techniques. Sequential moments were applied to the calcaneus about the long axis of the tibia. Measured movements at subtalar level demonstrated plantarflexion coupled to supination and internal rotation (inversion) and dorsiflexion coupled to pronation and external rotation (eversion). These movements were resisted and were fully recovered when the external load was removed. Subtalar motion diminished as the ankle approached maximal dorsi- and plantarflexion. Two clearly distinguished mean axes of rotation were observed for inversion and eversion runs. The axes of inversion and eversion of the subtalar complex changed orientation along a preferred and repeatable path. The subtalar joint complex occupied only a single stable position in the unloaded state and with no range of unresisted motion. It is inferred that mobility was possible only by the stretching and lengthening of the ligaments and the indentation of the articular surfaces, requiring the application of loads. The subtalar joint complex behaves like a flexible structure.  相似文献   

7.
The paper describes a method in which two data-collecting systems, medical imaging and electrogoniometry, are combined to allow the accurate and simultaneous modeling of both the spatial kinematics and the morphological surface of a particular joint. The joint of interest (JOI) is attached to a Plexiglas jig that includes four metallic markers defining a local reference system (R(GONIO)) for the kinematics data. Volumetric data of the JOI and the R(GONIO) markers are collected from medical imaging. The spatial location and orientation of the markers in the global reference system (R(CT)) of the medical-imaging environment are obtained by applying object-recognition and classification methods on the image dataset. Segmentation and 3D isosurfacing of the JOI are performed to produce a 3D model including two anatomical objects-the proximal and distal JOI segments. After imaging, one end of a custom-made 3D electrogoniometer is attached to the distal segment of the JOI, and the other end is placed at the R(GONIO) origin; the JOI is displaced and the spatial kinematics data is recorded by the goniometer. After recording, data registration from R(GONIO) to R(CT) occurred prior to simulation. Data analysis was performed using both joint coordinate system (JCS) and instantaneous helical axis (IHA).Finally, the 3D joint model is simulated in real time using the experimental kinematics data. The system is integrated into a computer graphics interface, allowing free manipulation of the 3D scene.The overall accuracy of the method has been validated with two other kinematics data collection methods including a 3D digitizer and interpolation of the kinematics data from discrete positions obtained from medical imaging. Validation has been performed on both superior and inferior radio-ulna joints (i.e. prono-supination motion). Maximal RMS error was 1 degrees and 1.2mm on the helical axis rotation and translation, respectively. Prono-supination of the forearm showed a total rotation of 132 degrees for 0.8mm of translation. The method reproducibility using JCS parameters was in average 1 degrees (maximal deviation=2 degrees ) for rotation, and 1mm (maximal deviation=2mm) for translation. In vitro experiments have been performed on both knee joint and ankle joint. Averaged JCS parameters for the knee were 109 degrees, 17 degrees and 4 degrees for flexion, internal rotation and abduction, respectively. Averaged maximal translation values for the knee were 12, 3 and 4mm posteriorly, medially and proximally, respectively. Averaged JCS parameters for the ankle were 43 degrees, 9 degrees and 3 degrees for plantarflexion, adduction and internal rotation, respectively. Averaged maximal translation values for the ankle were 4, 2 and 1mm anteriorly, medially and proximally, respectively.  相似文献   

8.
BACKGROUND. To describe 3D shoulder joint movements, the International Society of Biomechanics (ISB) recommends using segment coordinate systems (SCSs) on the humerus, scapula and thorax, and joint coordinate systems (JCSs) on the shoulder. However, one of the remaining problems is how to define the zero angles when the arm is in an initial reference position. The aim of this paper is to compare various methods of determining the JCSs of the shoulder that make it possible to define the zero angles of the arm in the resting position. METHODS. Able-bodied subjects performed elevation movements in the scapular plane, specifically neutral, internal and external rotations of the humerus. The initial humerus position (at the beginning of the arm movement) and range of motion were analysed for the purpose of clinical interpretation of arm attitude and movement. The following four different JCSs were explored: (1) the standard JCS, defined as recommended by the ISB, (2) a first aligned JCS, where the humerus SCS is initially aligned with the scapula SCS, (3) a second aligned JCS, where the opposite operation is performed and 4) a third aligned JCS, where both the humerus and the scapular SCS are initially aligned with the thorax SCS. FINDINGS. The second aligned JCS was the only method that did not produce any exaggerated range of movement in either anatomical plane. INTERPRETATION. Mathematical JCS alignment allows clearer clinical interpretation of arm attitude and movement.  相似文献   

9.
Joint surface interaction and ligament constraints determine the kinematic characteristics of the ankle and subtalar joints. Joint surface interaction is characterized by joint contact mechanics and by relative joint surface position potentially characterized by distance mapping. While ankle contact mechanics was investigated, limited information is available on joint distance mapping and its changes during motion. The purpose of this study was to use image-based distance mapping to quantify this interaction at the ankle and subtalar joints during tri-planar rotations of the ankle complex. Five cadaveric legs were scanned using Computed Tomography and the images were processed to produce 3D bone models of the tibia, fibula, talus and calcaneus. Each leg was tested on a special linkage through which the ankle complex was loaded in dorsiflexion/plantarflexion, inversion/eversion, and internal/external rotation and the resulting bone movements were recorded. Fiduciary bone markers data and 3D bone models were combined to generate color-coded distance maps for the ankle and subtalar joints. The results were processed focusing on the changes in surface-to-surface distance maps between the extremes of the range of motion and neutral. The results provided detailed insight into the three-dimensional highly coupled nature of these joints showing significant and unique changes in distance mapping from neutral to extremes of the range of motion. The non-invasive nature of the image-based distance mapping technique could result, after proper modifications, in an effective diagnostic and clinical evaluation technique for application such as ligament injuries and quantifying the effect of arthrodesis or total ankle replacement surgery.  相似文献   

10.
The Standardization and Terminology Committee (STC) of the International Society of Biomechanics (ISB) proposes a general reporting standard for joint kinematics based on the Joint Coordinate System (JCS), first proposed by Grood and Suntay for the knee joint in 1983 (J. Biomech. Eng. 105 (1983) 136). There is currently a lack of standard for reporting joint motion in the field of biomechanics for human movement, and the JCS as proposed by Grood and Suntay has the advantage of reporting joint motions in clinically relevant terms. In this communication, the STC proposes definitions of JCS for the ankle, hip, and spine. Definitions for other joints (such as shoulder, elbow, hand and wrist, temporomandibular joint (TMJ), and whole body) will be reported in later parts of the series. The STC is publishing these recommendations so as to encourage their use, to stimulate feedback and discussion, and to facilitate further revisions. For each joint, a standard for the local axis system in each articulating bone is generated. These axes then standardize the JCS. Adopting these standards will lead to better communication among researchers and clinicians.  相似文献   

11.
Ying N  Kim W 《Journal of biomechanics》2002,35(12):146-1657
This paper presents a modified Euler angles method, dual Euler angles approach, to describe general spatial human joint motions. In dual Euler angles approach, the three-dimensional joint motion is considered as three successive screw motions with respect to the axes of the moving segment coordinate system; accordingly, the screw motion displacements are represented by dual Euler angles. The algorithm for calculating dual Euler angles from coordinates of markers on the moving segment is also provided in this study. As an example, the proposed method is applied to describe motions of ankle joint complex during dorsiflexion–plantarflexion. A Flock of Birds electromagnetic tracking device (FOB) was used to measure joint motion in vivo. Preliminary accuracy tests on a gimbal structure demonstrate that the mean errors of dual Euler angles evaluated by using source data from FOB are less than 1° for rotations and 1 mm for translations, respectively. Based on the pilot study, FOB is feasible for quantifying human joint motions using dual Euler angles approach.  相似文献   

12.
The goal of this study was to examine the influence of changes in foot positioning at touch-down on ankle sprain occurrence. Muscle model driven computer simulations of 10 subjects performing the landing phase of a side-shuffle movement were performed. The relative subtalar joint and talocural joint angles at touchdown were varied, and each subject-specific simulation was exposed to a set of perturbed floor conditions. The touchdown subtalar joint angle was not found to have a considerable influence on sprain occurrence, while increased touchdown plantar flexion caused increased ankle sprain occurrences. Increased touchdown plantar flexion may be the mechanism which causes ankles with a history of ankle sprains to have an increased susceptibility to subsequent sprains. This finding may also reveal a mechanism by which taping of a sprained ankle or the application of an ankle brace leads to decreased ankle sprain susceptibility.  相似文献   

13.
In vivo estimates of tibiotalar and the subtalar joint kinematics can unveil unique information about gait biomechanics, especially in the presence of musculoskeletal disorders affecting the foot and ankle complex. Previous literature investigated the ankle kinematics on ex vivo data sets, but little has been reported for natural walking, and even less for pathological and juvenile populations. This paper proposes an MRI-based morphological fitting methodology for the personalised definition of the tibiotalar and the subtalar joint axes during gait, and investigated its application to characterise the ankle kinematics in twenty patients affected by Juvenile Idiopathic Arthritis (JIA). The estimated joint axes were in line with in vivo and ex vivo literature data and joint kinematics variation subsequent to inter-operator variability was in the order of 1°. The model allowed to investigate, for the first time in patients with JIA, the functional response to joint impairment. The joint kinematics highlighted changes over time that were consistent with changes in the patient’s clinical pattern and notably varied from patient to patient. The heterogeneous and patient-specific nature of the effects of JIA was confirmed by the absence of a correlation between a semi-quantitative MRI-based impairment score and a variety of investigated joint kinematics indexes. In conclusion, this study showed the feasibility of using MRI and morphological fitting to identify the tibiotalar and subtalar joint axes in a non-invasive patient-specific manner. The proposed methodology represents an innovative and reliable approach to the analysis of the ankle joint kinematics in pathological juvenile populations.  相似文献   

14.
Clinical gait analysis usually describes joint kinematics using Euler angles, which depend on the sequence of rotation. Studies have shown that pelvic obliquity angles from the traditional tilt-obliquity-rotation (TOR) Euler angle sequence can deviate considerably from clinical expectations and have suggested that a rotation-obliquity-tilt (ROT) Euler angle sequence be used instead. We propose a simple alternate approach in which clinical joint angles are defined and exactly calculated in terms of Euler angles from any rotation sequence. Equations were derived to calculate clinical pelvic elevation, progression, and lean angles from TOR and ROT Euler angles. For the ROT Euler angles, obliquity was exactly the same as the clinical elevation angle, rotation was similar to the clinical progression angle, and tilt was similar to the clinical lean angle. Greater differences were observed for TOR. These results support previous findings that ROT is preferable to TOR for calculating pelvic Euler angles for clinical interpretation. However, we suggest that exact clinical angles can and should be obtained through a few extra calculations as demonstrated in this technical note.  相似文献   

15.
Computational models of musculoskeletal joints and limbs can provide useful information about joint mechanics. Validated models can be used as predictive devices for understanding joint function and serve as clinical tools for predicting the outcome of surgical procedures. A new computational modeling approach was developed for simulating joint kinematics that are dictated by bone/joint anatomy, ligamentous constraints, and applied loading. Three-dimensional computational models of the lower leg were created to illustrate the application of this new approach. Model development began with generating three-dimensional surfaces of each bone from CT images and then importing into the three-dimensional solid modeling software SOLIDWORKS and motion simulation package COSMOSMOTION. Through SOLIDWORKS and COSMOSMOTION, each bone surface file was filled to create a solid object and positioned necessary components added, and simulations executed. Three-dimensional contacts were added to inhibit intersection of the bones during motion. Ligaments were represented as linear springs. Model predictions were then validated by comparison to two different cadaver studies, syndesmotic injury and repair and ankle inversion following ligament transection. The syndesmotic injury model was able to predict tibial rotation, fibular rotation, and anterior/posterior displacement. In the inversion simulation, calcaneofibular ligament extension and angles of inversion compared well. Some experimental data proved harder to simulate accurately, due to certain software limitations and lack of complete experimental data. Other parameters that could not be easily obtained experimentally can be predicted and analyzed by the computational simulations. In the syndesmotic injury study, the force generated in the tibionavicular and calcaneofibular ligaments reduced with the insertion of the staple, indicating how this repair technique changes joint function. After transection of the calcaneofibular ligament in the inversion stability study, a major increase in force was seen in several of the ligaments on the lateral aspect of the foot and ankle, indicating the recruitment of other structures to permit function after injury. Overall, the computational models were able to predict joint kinematics of the lower leg with particular focus on the ankle complex. This same approach can be taken to create models of other limb segments such as the elbow and wrist. Additional parameters can be calculated in the models that are not easily obtained experimentally such as ligament forces, force transmission across joints, and three-dimensional movement of all bones. Muscle activation can be incorporated in the model through the action of applied forces within the software for future studies.  相似文献   

16.
Background. To describe 3D shoulder joint movements, the International Society of Biomechanics (ISB) recommends using segment coordinate systems (SCSs) on the humerus, scapula and thorax, and joint coordinate systems (JCSs) on the shoulder. However, one of the remaining problems is how to define the zero angles when the arm is in an initial reference position. The aim of this paper is to compare various methods of determining the JCSs of the shoulder that make it possible to define the zero angles of the arm in the resting position.

Methods. Able-bodied subjects performed elevation movements in the scapular plane, specifically neutral, internal and external rotations of the humerus. The initial humerus position (at the beginning of the arm movement) and range of motion were analysed for the purpose of clinical interpretation of arm attitude and movement. The following four different JCSs were explored: (1) the standard JCS, defined as recommended by the ISB, (2) a first aligned JCS, where the humerus SCS is initially aligned with the scapula SCS, (3) a second aligned JCS, where the opposite operation is performed and 4) a third aligned JCS, where both the humerus and the scapular SCS are initially aligned with the thorax SCS.

Findings. The second aligned JCS was the only method that did not produce any exaggerated range of movement in either anatomical plane.

Interpretation. Mathematical JCS alignment allows clearer clinical interpretation of arm attitude and movement.  相似文献   

17.
Baker R 《Journal of biomechanics》2011,44(10):1885-1891
Three different methods for describing three dimensional joint angles are commonly used in biomechanics. The joint coordinate system and Cardan/Euler angles are conceptually quite different but are known to represent the same underlying mathematics. More recently the globographic method has been suggested as an alternative and this has proved particularly attractive for the shoulder joint. All three methods can be implemented in a number of ways leading to a choice of angle definitions. Very recently Rab has demonstrated that the globographic method is equivalent to one implementation of the joint coordinate system. This paper presents a rigorous analysis of the three different methods and proves their mathematical equivalence. The well known sequence dependence of Cardan/Euler is presented as equivalent to configuration dependence of the joint coordinate system and orientation dependence of globographic angles. The precise definition of different angle sets can be easily visualised using the globographic method using analogues of longitude, latitude and surface bearings with which most users will already be familiar. The method implicitly requires one axis of the moving segment to be identified as its principal axis and this can be extremely useful in helping define the most appropriate angle set to describe the orientation of any particular joint. Using this technique different angle sets are considered to be most appropriate for different joints and examples of this for the hip, knee, ankle, pelvis and axial skeleton are outlined.  相似文献   

18.
Orientation of the subtalar joint axis dictates inversion and eversion movements of the foot and has been the focus of evolutionary and clinical studies for a number of years. Previous studies have measured the subtalar joint axis against the axis of the whole foot, the talocrural joint axis and, recently, the principal axes of the talus. The present study introduces a new method for estimating average joint axes from 3D reconstructions of bones and applies the method to the talus to calculate the subtalar and talocrural joint axes. The study also assesses the validity of the principal axes as a reference coordinate system against which to measure the subtalar joint axis. In order to define the angle of the subtalar joint axis relative to that of another axis in the talus, we suggest measuring the subtalar joint axis against the talocrural joint axis. We present corresponding 3D vector angles calculated from a modern human skeletal sample. This method is applicable to virtual 3D models acquired through surface-scanning of disarticulated 'dry' osteological samples, as well as to 3D models created from CT or MRI scans.  相似文献   

19.
In this paper, we present an inverse kinematics method to determining human shoulder joint motion coupling relationship based on experimental data in the literature. This work focuses on transferring Euler-angle-based coupling equations into a relationship based on the Denavit–Hartenberg (DH) method. We use analytical inverse kinematics to achieve the transferring. For a specific posture, we can choose points on clavicle, scapula, and humerus and represent the end-effector positions based on Euler angles or DH method. For both Euler and DH systems, the end-effectors have the same Cartesian positions. Solving these equations related to end-effector positions yields DH joint angles for that posture. The new joint motion coupling relationship is obtained by polynomial and cosine fitting of the DH joint angles for all different postures.  相似文献   

20.
This study presents a free-fall mechanical supination sprain simulator for evaluating the ankle joint kinematics during a simulated ankle supination sprain injury. The device allows the foot to be in an anatomical position before the sudden motion, and also allows different degrees of supination, or a combination of inversion and plantarflexion. Five subjects performed simulated supination sprain trials in five different supination angles. Ankle motion was captured by a motion analysis system, and the ankle kinematics were reported in plantarflexion/dorsiflexion, inversion/eversion and internal/external rotation planes. Results showed that all sprain motions were not pure single-plane motions but were accompanied by motion in other two planes, therefore, different degrees of supination were achieved. The presented sprain simulator allows a more comprehensive study of the kinematics of ankle sprain when compared with some previous laboratory research designs.  相似文献   