首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Thermophysiological responses of heat production and heat loss were measured in seven adult volunteers (six males and one female, aged 31-74 years) during 45 min dorsal exposures of the whole body to 100 MHz continuous wave (CW) radio frequency (RF) energy. Three power densities (PD) (average PD = 4, 6, and 8 mW/cm(2); whole body specific absorption rate [SAR] = 0.068 [W/kg]/[mW/cm(2)]) were tested in each of three ambient temperatures (T(a) = 24, 28, and 31 degrees C), as well as in T(a) controls (no RF). A standardized protocol (30 min baseline, 45 min RF or sham exposure, 10 min baseline) was used. Measured responses included esophageal and seven skin temperatures, metabolic heat production, local sweat rate, and local skin blood flow. No changes in metabolic heat production occurred under any test condition. Unlike published results of similar exposures at 450 and 2450 MHz, local skin temperatures, even those on the back that were irradiated directly, changed little or not at all during 100 MHz exposures. The sole exception was the temperature of the ankle skin, which increased by 3-4 degrees C in some subjects at PD = 8 mW/cm(2). During the 45 min RF exposure, esophageal temperature showed modest changes (range = -0.15 to 0.13 degrees C) and never exceeded 37.2 degrees C. Thermoregulation was principally controlled by appropriate increases in evaporative heat loss (sweating) and, to a lesser extent, by changes in skin blood flow. Because of the deep penetration of RF energy at this frequency, effectively bypassing the skin, these changes must have been stimulated by thermal receptors deep in the body rather than those located in the skin.  相似文献   

2.
Permission was received from the Brooks AFB Institutional Review Board and the AF Surgeon General's Office to exceed the peak power density (PD = 35 mW/cm(2)) we had previously studied during partial body exposure of human volunteers at 2450 MHz. Two additional peak PD were tested (50 and 70 mW/cm(2)). The higher of these PD (normalized peak local SAR = 15.4 W/kg) is well outside the IEEE C95.1 guidelines for partial body exposure, as is the estimated whole body SAR approximately 1.0 W/kg. Seven volunteers (four males, three females) were tested at each PD in three ambient temperatures (T(a) = 24, 28, and 31 degrees C) under our standard protocol (30 min baseline, 45 min RF exposure, 10 min baseline). The thermophysiological data (esophageal and six skin temperatures, metabolic heat production, local sweat rate, and local skin blood flow) were combined with comparable data at PD = 0, 27, and 35 mW/cm(2) from our 1999 study to generate response functions across PD. No change in esophageal temperature or metabolic heat production was recorded at any PD in any T(a). At PD = 70 mW/cm(2), skin temperature on the upper back (irradiated directly) increased 4.0 degrees C in T(a) = 24 degrees C, 2.6 degrees C in T(a) = 28 degrees C, and 1.8 degrees C in T(a) = 31 degrees C. These differences were primarily due to the increase in local sweat rate, which was greatest in T(a) = 31 degrees C. Also at PD = 70 mW/cm(2), local skin blood flow on the back increased 65% over baseline levels in T(a) = 31 degrees C, but only 40% in T(a) = 24 degrees C. Although T(a) becomes an important variable when RF exposure exceeds the C95.1 partial body exposure limits, vigorous heat loss responses of blood flow and sweating maintain thermal homeostasis efficiently. It is also clear that strong sensations of heat and thermal discomfort will motivate a timely retreat from a strong RF field, long before these physiological responses are exhausted. Published 2001 Wiley-Liss, Inc.  相似文献   

3.
Thermoregulatory responses of heat production and heat loss were measured in seven adult volunteers (four women and three men, aged 21–57 yr) during 45-min dorsal exposures of the whole body to 450 MHz continuous wave radio frequency (RF) fields. Two power densities (PD) (local peak PD = 18 and 24 mW/cm2; local peak specific absorption rate = 0.320 [W/kg]/[mW/cm2]) were tested in each of three ambient temperatures (Ta = 24, 28, and 31 °C) plus Ta controls (no RF). No changes in metabolic heat production occurred under any exposure conditions. Vigorous increases in sweating rate on back and chest, directly related to both Ta and PD, cooled the skin and ensured efficient regulation of the deep body (esophageal) temperature to within 0.1 °C of the normal level. Category judgments of thermal sensation, comfort, sweating, and thermal preference usually matched the measured changes in physiological responses. Some subtle effects related to gender were noted that confirm classic physiological data. Our results indicate that dorsal exposures of humans to a supra-resonant frequency of 450 MHz at local peak specific absorption rates up to 7.68 W/kg are mildly thermogenic and are counteracted efficiently by normal thermophysiologic heat loss mechanisms, principally sweating. Bioelectromagnetics 19:232–245, 1998. Published 1998 Wiley-Liss, Inc.  相似文献   

4.
Many reports describe data showing that continuous wave (CW) and pulsed (PW) radiofrequency (RF) fields, at the same frequency and average power density (PD), yield similar response changes in the exposed organism. During whole-body exposure of squirrel monkeys at 2450 MHz CW and PW fields, heat production and heat loss responses were nearly identical. To explore this question in humans, we exposed two different groups of volunteers to 2450 MHz CW (two females, five males) and PW (65 micros pulse width, 10(4) pps; three females, three males) RF fields. We measured thermophysiological responses of heat production and heat loss (esophageal and six skin temperatures, metabolic heat production, local skin blood flow, and local sweat rate) under a standardized protocol (30 min baseline, 45 min RF or sham exposure, 10 min baseline), conducted in three ambient temperatures (T(a) = 24, 28, and 31 degrees C). At each T(a), average PDs studied were 0, 27, and 35 mW/cm2 (Specific absorption rate (SAR) = 0, 5.94, and 7.7 W/kg). Mean data for each group showed minimal changes in core temperature and metabolic heat production for all test conditions and no reliable differences between CW and PW exposure. Local skin temperatures showed similar trends for CW and PW exposure that were PD-dependent; only the skin temperature of the upper back (facing the antenna) showed a reliably greater increase (P =.005) during PW exposure than during CW exposure. Local sweat rate and skin blood flow were both T(a)- and PD-dependent and showed greater variability than other measures between CW and PW exposures; this variability was attributable primarily to the characteristics of the two subject groups. With one noted exception, no clear evidence for a differential response to CW and PW fields was found.  相似文献   

5.
The purpose of the study was to examine the effect of 1) passive (assisted pedaling), 2) active (loadless pedaling), and 3) inactive (motionless) recovery modes on mean arterial pressure (MAP), skin blood flow (SkBF), and sweating during recovery after 15 min of dynamic exercise. It was hypothesized that an active recovery mode would be most effective in attenuating the fall in MAP, SkBF, and sweating during exercise recovery. Six male subjects performed 15 min of cycle ergometer exercise at 70% of their predetermined peak oxygen consumption followed by 15 min of 1) active, 2) passive, or 3) inactive recovery. Mean skin temperature (T(sk)), esophageal temperature (T(es)), SkBF, sweating, cardiac output (CO), stroke volume (SV), heart rate (HR), total peripheral resistance (TPR), and MAP were recorded at baseline, end exercise, and 2, 5, 8, 12, and 15 min postexercise. Cutaneous vascular conductance (CVC) was calculated as the ratio of laser-Doppler blood flow to MAP. In the active and passive recovery modes, CVC, sweat rate, MAP, CO, and SV remained elevated over inactive values (P < 0.05). The passive mode was equally as effective as the active mode in maintaining CO, SV, MAP, CVC, and sweat rate above inactive recovery. Sweat rate was different among all modes after 8 min of recovery (P < 0.05). TPR during active recovery remained significantly lower than during recovery in the passive and inactive modes (P < 0.05). No differences in either T(es) or T(sk) were observed among conditions. Given that MAP was higher during passive and active recovery modes than during inactive recovery suggests differences in CVC may be due to differences in baroreceptor unloading and not factors attributed to central command. However, differences in sweat rate may be influenced by factors such as central command and mechanoreceptor stimulation.  相似文献   

6.
The present study was undertaken to investigate the thermal adjustments of squirrel monkeys exposed in a cold environment to relatively high energy levels of microwave fields. The animals (Saimiri sciureus) were equilibrated for 90 min to a cool environment (Ta = 20 degrees C) to elevate metabolic heat production (M). They were then exposed for brief (10-min) or long (30-min) periods to 2,450-MHz continuous-wave microwaves. Power densities (MPD) were 10, 14, 19, and 25 mW/cm2 during brief exposures and 30, 35, 40, and 45 mW/cm2 during long exposures (rate of energy absorption: SAR = 0.15 [W/kg]/[mW/cm2]). Individual exposures were separated by enough time to allow physiological variables to return to baseline levels. The results confirm that each microwave exposure induced a rapid decrease in M. In a 20 degree C environment, the power density of a 10-min exposure required to lower M to approximate the resting level was 35 mW/cm2 (SAR = 5.3 W/kg). During the long exposures, 20 min was needed to decrease M to its lowest level. Cessation of irradiation was associated with persistence of low levels of M for periods that depended on the power density of the preceding microwave exposure. Vasodilation, as indexed by changes in local skin temperature, occurred at a high rate of energy absorption (SAR = 4.5 W/kg) and was sufficient to prevent a dramatic increase in storage of thermal energy by the body; vasoconstriction was reinstated after termination of irradiation. Patterns of thermophysiological responses confirm the influence both of peripheral and of internal inputs to thermoregulation in squirrel monkeys exposed to microwaves in a cool environment.  相似文献   

7.
This study was designed to identify and measure changes in thermoregulatory responses, both behavioral and physiological, that may occur when squirrel monkeys are exposed to 2450-MHz continuous wave microwaves 40 hr/week for 15 weeks. Power densities of 1 or 5 mW/cm2 (specific absorption rate = 0.16 W/kg per mW/cm2) were presented at controlled environmental temperatures of 25, 30, or 35 degrees C. Standardized tests, conducted periodically, before, during, and after treatment, assessed changes in thermoregulatory responses. Dependent variables that were measured included body mass, certain blood properties, metabolic heat production, sweating, skin temperatures, deep body temperature, and behavioral responses by which the monkeys selected a preferred environmental temperature. Results showed no reliable alteration of metabolic rate, internal body temperature, blood indices, or thermoregulatory behavior by microwave exposure, although the ambient temperature prevailing during chronic exposure could exert an effect. An increase in sweating rate occurred in the 35 degrees C environment, but sweating was not reliably enhanced by microwave exposure. Skin temperature, reflecting vasomotor state, was reliably influenced by both ambient temperature and microwaves. The most robust consequence of microwave exposure was a reduction in body mass, which appeared to be a function of microwave power density.  相似文献   

8.
To test whether heat-sensitive receptors participate in the cutaneous vascular responses to direct heating, we monitored skin blood flow (SkBF; laser Doppler flowmetry) where the sensation of heat was induced either by local warming (T(Loc); Peltier cooling/heating unit) or by both direct warming and chemical stimulation of heat-sensitive nociceptors (capsaicin). In part I, topical capsaicin (0.075 or 0.025%) was applied to 12 cm(2) of skin 1 h before stepwise local warming of untreated and capsaicin-treated forearm skin. Pretreatment with 0.075% capsaicin cream shifted the SkBF/T(Loc) relationship to lower temperatures by an average of 6 +/- 0.8 degrees C (P < 0.05). In part II, we used a combination of topical capsaicin (0.025%) and local warming to evoke thermal sensation at one site and only local warming to evoke thermal sensation at a separate site. Cutaneous vasomotor responses were compared when the temperatures at these two sites were perceived to be the same. SkBF differed significantly between capsaicin and control sites when compared on the basis of actual temperatures, but that difference became insignificant when compared on the basis of the perceived temperatures. These data suggest heat-sensitive nociceptors are important in the cutaneous vasodilator response to local skin warming.  相似文献   

9.
Thermoregulatory responses of heat production and heat loss were measured in two different groups of seven adult volunteers (males and females) during 45‐min dorsal exposures of the whole body to 450 or 2450 MHz continuous‐wave radio frequency (RF) fields. At each frequency, two power densities (PD) were tested at each of three ambient temperatures (Ta = 24, 28, and 31 °C) plus Ta controls (no RF). The normalized peak surface specific absorption rate (SAR), measured at the location of the subject's center back, was the same for comparable PD at both frequencies, i.e., peak surface SAR = 6.0 and 7.7 W/kg. No change in metabolic heat production occurred under any exposure conditions at either frequency. The magnitude of increase in those skin temperatures under direct irradiation was directly related to frequency, but local sweating rates on back and chest were related more to Ta and SAR. Both efficient sweating and increased local skin blood flow contributed to the regulation of the deep body (esophageal) temperature to within 0.1 °C of the baseline level. At both frequencies, normalized peak SARs in excess of ANSI/IEEE C95.1 guidelines were easily counteracted by normal thermophysiological mechanisms. The observed frequency‐related response differences agree with classical data concerning the control of heat loss mechanisms in human beings. However, more practical dosimetry than is currently available will be necessary to evaluate realistic human exposures to RF energy in the natural environment. Bioelectromagnetics 20:12–20, 1999. Published 1999 Wiley‐Liss, Inc.  相似文献   

10.
Graded cutaneous vascular responses to dynamic leg exercise   总被引:2,自引:0,他引:2  
The cutaneous vascular conductance-esophageal temperature (CVC-Tes) relationship was examined at five work loads (75-200 W) in each of four men to find whether there is a role for exercise intensity in the control of skin blood flow (SkBF). Several factors contributed to our evaluation of the CVC-Tes relationship during work. Laser-Doppler velocimetry (LDF) provided a continuous measure of SkBF that is not influenced by underlying muscle blood flow. Local warming to 39 degrees C at the site of measurement of SkBF provided a consistent skin temperature and facilitated observation of changes in LDF. Mean arterial pressure was measured noninvasively once per minute to calculate CVC. Supine exercise minimized baroreceptor-induced cutaneous vasoconstriction. Our major finding was that the internal temperature at which CVC began to rise during exercise (CVC threshold) was graded with work load beyond 125 W (P less than 0.05). In that range the CVC threshold increased by 0.16 degrees C for every increment of 25 W. The CVC threshold was never reached at the highest work load in three of the four subjects. There was no consistent effect of work load on the slope of the CVC-Tes relationship or on the internal temperature at which sweating began during exercise (sweat rate threshold). We conclude that the level of work beyond 125 W affects the CVC-Tes relationship in a graded fashion, principally through shifts in threshold.  相似文献   

11.
The effect of acute hypobaric hypoxia on local sweating and cutaneous blood flow was studied in four men and four women (follicular phase of menstrual cycle), who exercised at 60% of their altitude-specific peak aerobic power for 35 min at barometric pressures (PB) of 770 Torr (sea level), 552 Torr (2,596 m), and 428 Torr (4,575 m) at an ambient temperature of 30 degrees C. We measured esophageal temperature (Tes), mean skin temperature (Tsk, 8 sites), and local sweating (ms) from dew-point sensors attached to the skin at the chest, arm, and thigh. Skin blood flow (SkBF) of the forearm was measured once each minute by venous occlusion plethysmography. There were no gender differences in the sensitivity (slope) or the threshold of either ms/Tes or SkBF/Tes at any altitude. No change in the Tes for sweating onset occurred with altitude. The mean slopes of the ms/Tes relationships for the three regional sites decreased with increasing altitude, although these differences were not significant between the two lower PBS. The slope of SkBF/Tes was reduced in five of the eight subjects at 428 Torr. Enhanced body cooling as a response to the higher evaporative capacity of the environment is suggested as a component of these peripheral changes occurring in hypobaric hypoxia.  相似文献   

12.
Previous studies have suggested that greater core temperatures during intermittent exercise (Ex) are due to attenuated sweating [upper back sweat rate (SR)] and skin blood flow (SkBF) responses. We evaluated the hypothesis that heat loss is not altered during exercise-rest cycles (ER). Ten male participants randomly performed four 120-min trials: 1) 60-min Ex and 60-min recovery (60ER); 2) 3 × 20-min Ex separated by 20-min recoveries (20ER); 3) 6 × 10-min Ex separated by 10-min recoveries (10ER), or 4) 12 × 5-min Ex separated by 5-min recoveries (5ER). Exercise was performed at a workload of 130 W at 35°C. Whole body heat exchange was determined by direct calorimetry. Core temperature, SR (by ventilated capsule), and SkBF (by laser-doppler) were measured continuously. Evaporative heat loss (EHL) progressively increased with each ER, such that it was significantly greater (P ≤ 0.05) at the end of the last compared with the first Ex for 5ER (299 ± 39 vs. 440 ± 41 W), 10ER (425 ± 51 vs. 519 ± 45 W), and 20ER (515 ± 63 vs. 575 ± 74 W). The slope of the EHL response against esophageal temperature significantly increased from the first to the last Ex within the 10ER (376 ± 56 vs. 445 ± 89 W/°C, P ≤ 0.05) and 20ER (535 ± 85 vs. 588 ± 28 W/°C, P ≤ 0.05) conditions, but not during 5ER (296 ± 96 W/°C vs. 278 ± 95 W/°C, P = 0.237). In contrast, the slope of the SkBF response against esophageal temperature did not significantly change from the first to the last Ex (5ER: 51 ± 23 vs. 54 ± 19%/°C, P = 0.848; 10ER: 53 ± 8 vs. 56 ± 21%/°C, P = 0.786; 20ER: 44 ± 20 vs. 50 ± 27%/°C, P = 0.432). Overall, no differences in body heat content and core temperature were observed. These results suggest that altered local and whole body heat loss responses do not explain the previously observed greater core temperatures during intermittent exercise.  相似文献   

13.
1. During the control, tympanic temperature (Tty), skin blood flow (SkBF), local sweating rate (LSR) and heart rate (HR) of the AC were markedly higher than those of the BE. No significant differences were finally observed in rectal (Tre) and mean skin (Tsk) temperatures or oxygen uptake (VO2). In contrast, mechanical work efficiency (ME) was significantly higher in the BE than in the AC.

2. During ice cooling, Tty and the increasing rate in Tty began to be suppressed at 25–35 min after the beginning in both kinds of work. During the AC, SkBF, LSR, HR and mean Tsk in the ice cooling tended to be lower compared those in the control. There were no significant difference between the control and the ice cooling in ME, VO2 or Tre in either kind of work.  相似文献   


14.
In humans, the nocturnal fall in internal temperature is associated with increased endogenous melatonin and with a shift in the thermoregulatory control of skin blood flow (SkBF), suggesting a role for melatonin in the control of SkBF. The purpose of this study was to test whether daytime exogenous melatonin would shift control of SkBF to lower internal temperatures during heat stress, as is seen at night. Healthy male subjects (n = 8) underwent body heating with melatonin administration (Mel) or without (control), in random order at least 1 wk apart. SkBF was monitored at sites pretreated with bretylium to block vasoconstrictor nerve function and at untreated sites. Cutaneous vascular conductance, calculated from SkBF and arterial pressure, sweating rate (SR), and heart rate (HR) were monitored. Skin temperature was elevated to 38 degrees C for 35-50 min. Baseline esophageal temperature (Tes) was lower in Mel than in control (P < 0.01). The Tes threshold for cutaneous vasodilation and the slope of cutaneous vascular conductance with respect to Tes were also lower in Mel at both untreated and bretylium-treated sites (P < 0.05). The Tes threshold for the onset of sweating and the Tes for a standard HR were reduced in Mel. The slope of the relationship of HR, but not SR, to Tes was lower in Mel (P < 0.05). These findings suggest that melatonin affects the thermoregulatory control of SkBF during hyperthermia via the cutaneous active vasodilator system. Because control of SR and HR are also modified, a central action of melatonin is suggested.  相似文献   

15.
A previous study showed a substantial increase in the colonic temperature of rhesus monkeys (Macaca mulatta) exposed to radiofrequency (RF) fields at a frequency near whole-body resonance and specific absorption rates (SAR) of 2-3 W/kg. The present experiments were conducted to determine the metabolic and vasomotor responses during exposures to similar RF fields. We exposed five adult male rhesus monkeys to 225 MHz radiation (E orientation) in an anechoic chamber. Oxygen consumption and carbon dioxide production were measured before, during, and after RF exposure. Colonic, tail and leg skin temperatures were continuously monitored with RF-nonperturbing probes. The monkeys were irradiated at two carefully-controlled ambient temperatures, either cool (20 degrees C) or thermoneutral (26 degrees C). Power densities ranged from 0 (sham) to 10.0 mW/cm2 with an average whole-body SAR of 0.285 (W/kg)/(mW/cm2). We used two experimental protocols, each of which began with a 120-min pre-exposure equilibration period. One protocol involved repetitive 10-min RF exposures at successively higher power densities with a recovery period between exposures. In the second protocol, a 120-min RF exposure permitted the measurement of steady-state thermoregulatory responses. Metabolic and vasomotor adjustments in the rhesus monkey exposed to 225 MHz occurred during brief or sustained exposures at SARs at or above 1.4 W/kg. The SAR required to produce a given response varied with ambient temperature. Metabolic and vasomotor responses were coordinated effectively to produce a stable deep body temperature. The results show that the thermoregulatory response of the rhesus monkey to an RF exposure at a resonant frequency limits storage of heat in the body. However, substantial increases in colonic temperature were not prevented by such responses, even in a cool environment.  相似文献   

16.
Nitric oxide (NO) participates in locally mediated vasodilation induced by increased local skin temperature (T(loc)) and in sympathetically mediated vasodilation during whole body heat stress. We hypothesized that endothelial NOS (eNOS) participates in the former, but not the latter, response. We tested this hypothesis by examining the effects of the eNOS antagonist N(G)-amino-l-arginine (l-NAA) on skin blood flow (SkBF) responses to increased T(loc) and whole body heat stress. Microdialysis probes were inserted into forearm skin for drug delivery. One microdialysis site was perfused with l-NAA in Ringer solution and a second site with Ringer solution alone. SkBF [laser-Doppler flowmetry (LDF)] and blood pressure [mean arterial pressure (MAP)] were monitored, and cutaneous vascular conductance (CVC) was calculated (CVC = LDF / MAP). In protocol 1, T(loc) was controlled with LDF/local heating units. T(loc) initially was held at 34 degrees C and then increased to 41.5 degrees C. In protocol 2, after a normothermic period, whole body heat stress was induced (water-perfused suits). At the end of both protocols, 58 mM sodium nitroprusside was perfused at both microdialysis sites to cause maximal vasodilation for data normalization. In protocol 1, CVC at 34 degrees C T(loc) did not differ between l-NAA-treated and untreated sites (P > 0.05). Local skin warming to 41.5 degrees C T(loc) increased CVC at both sites. This response was attenuated at l-NAA-treated sites (P < 0.05). In protocol 2, during normothermia, CVC did not differ between l-NAA-treated and untreated sites (P > 0.05). During heat stress, CVC rose to similar levels at l-NAA-treated and untreated sites (P > 0.05). We conclude that eNOS is predominantly responsible for NO generation in skin during responses to increased T(loc), but not during reflex responses to whole body heat stress.  相似文献   

17.
To compare the effects of exposure to a near-resonant frequency of microwaves at two orientations with a higher frequency exposure, five rhesus monkeys were exposed for 4 hr to 225 MHz, electric field oriented parallel to the long axis of the body (225 MHz-E), and to 225 MHz, magnetic field orientation (225 MHz-H), or to 1290 MHz, electric field orientation. On a separate occasion, the monkeys were exposed at night to 225 MHz-E. Exposures were conducted with the animal chair restrained in an anechoic chamber with rectal temperature continuously monitored. Blood samples were taken hourly during the 225-MHz-E exposures for cortisol analysis. The power densities used were 0, 1.2, 2.5, 5.0, 7.5, 10.0, and 15.0 mW/cm2 for 225 MHz-E (day), 0 and 5 mW/cm2 (225 MHz-E night and 225 MHz-H), and 0, 20, 28, and 38 mW/cm2 (1290 MHz). The monkeys were unable to tolerate exposure at power densities equal to or greater than 7.5 mW/cm2 (5.1 W/kg) at 225 MHz-E for longer than 90 min. The criterion for tolerance was that the rectal temperature would not exceed 41.5 degrees C. Average rectal temperature increases for day exposure to 225 MHz-E were 0.4 and 1.7 degrees C for 4-hr exposures to 2.5 and 5.0 mW/cm2 (1.7 and 3.4 W/kg). No changes in circulating cortisol levels occurred during any exposures to 5 mW/cm2 or less. Night exposures to 5 mW/cm2 (3.4 W/kg) at 225 MHz-E raised mean rectal temperature 2.1 degrees C. Exposure to 5 mW/cm2 (1.2 W/kg) at 225 MHz-H for 4 hr resulted in a 0.2 degree rise in mean rectal temperature. For 4 hr of 1290-MHz exposure to 20, 28, or 38 mW/cm2 (2.9, 4.0, and 5.4 W/kg), the mean body temperature increases were 0.4, 0.7, and 1.3 degrees C, respectively. The degree of hyperthermia caused by radiofrequency (rf) exposure was shown to be frequency and orientation dependent for equivalent power densities of exposure.  相似文献   

18.
To assess potential mechanisms responsible for the lower sudomotor thermosensitivity in women during exercise, we examined sex differences in sudomotor function and skin blood flow (SkBF) during exercise performed at progressive increases in the requirement for heat loss. Eight men and eight women cycled at rates of metabolic heat production of 200, 250, and 300 W/m(2) of body surface area, with each rate being performed sequentially for 30 min. The protocol was performed in a direct calorimeter to measure evaporative heat loss (EHL) and in a thermal chamber to measure local sweat rate (LSR) (ventilated capsule), SkBF (laser-Doppler), sweat gland activation (modified iodine-paper technique), and sweat gland output (SGO) on the back, chest, and forearm. Despite a similar requirement for heat loss between the sexes, significantly lower increases in EHL and LSR were observed in women (P ≤ 0.001). Sex differences in EHL and LSR were not consistently observed during the first and second exercise periods, whereas EHL (348 ± 13 vs. 307 ± 9 W/m(2)) and LSR on the back (1.61 ± 0.07 vs. 1.20 ± 0.09 mg·min(-1)·cm(-2)), chest (1.33 ± 0.06 vs. 1.08 ± 0.09 mg·min(-1)·cm(-2)), and forearm (1.53 ± 0.07 vs. 1.20 ± 0.06 mg·min(-1)·cm(-2), men vs. women) became significantly greater in men during the last exercise period (P < 0.05). At each site, differences in LSR were solely due to a greater SGO in men, as opposed to differences in sweat gland activation. In contrast, no sex differences in SkBF were observed throughout the exercise period. The present study demonstrates that sex differences in sudomotor function are only evidenced beyond a certain requirement for heat loss, solely through differences in SGO. In contrast, the lower EHL and LSR in women are not paralleled by a lower SkBF response.  相似文献   

19.
This study concerns with the multiple treatment of the target site to potent carcinogen and the super imposition of low level radiofrequency and microwave radiation. Swiss albino mice (male) were used for this investigation. The study has been divided in two parts, part A: a single dose of 7,12-dimethylbenz(a)anthracene (DMBA) 100 μg/animal was applied topically on the skin of mice and were exposed to 112 MHz amplitude modulated (AM) at 16 Hz (power density 1.0 mW/cm(2), specific absorption rate (SAR) 0.75 W/kg). Similarly after a single dose of DMBA, mice were exposed to 2.45 GHz radiation (power density of 0.34 mW/cm(2), SAR, 0.1 W/kg), 2 h/day, 3 days a week for a period of 16 weeks. The two sets of experiments were carried out separately. Part B: mice were transplanted intraperitoneally (ip) with ascites 8 × 10(8) (Ehrlich-Lettre ascites, strain E) carcinoma cells per mouse. These mice were exposed to 112 MHz amplitude modulated at 16 Hz and 2.45 GHz radiation separately for a period of 14 days. There was no tumor development in mice exposed to RF and MW. Similarly a topical application of single dose of DMBA followed by RF/MW exposure also did not produce any visible extra tumor on the skin of mice. On the other hand mice were transplanted intraperitoneally with ascites (8 × 10(8) cell/ml) and subsequently exposed to above mentioned fields for 14 days showed a slight increase in the cell numbers as compared to the control group. However, the increase is insignificant. There were insignificant differences either in the mortality or cell proliferation among the control and exposed group. This results show that low level RF or MW do not alter tumor growth and development as evidenced by no observable change in tumor size.  相似文献   

20.
The aim of this project was to develop an animal exposure system for the biological effect studies of radio frequency fields from handheld wireless telephones, with energy deposition in animal brains comparable to those in humans. The finite‐difference time‐domain (FDTD) method was initially used to compute specific absorption rate (SAR) in an ellipsoidal rat model exposed with various size loop antennas at different distances from the model. A 3 × 1 cm rectangular loop produced acceptable SAR patterns. A numerical rat model based on CT images was developed by curve‐fitting Hounsfield Units of CT image pixels to tissue dielectric properties and densities. To design a loop for operating at high power levels, energy coupling and impedance matching were optimized using capacitively coupled feed lines embedded in a Teflon rod. Sprague Dawley rats were exposed with the 3 × 1 cm loop antennas, tuned to 837 or 1957 MHz for thermographically determined SAR distributions. Point SARs in brains of restrained rats were also determined thermometrically using fiberoptic probes. Calculated and measured SAR patterns and results from the various exposure configurations are in general agreement. The FDTD computed average brain SAR and ratio of head to whole body absorption were 23.8 W/kg/W and 62% at 837 MHz, and 22.6 W/kg/W and 89% at 1957 MHz. The average brain to whole body SAR ratio was 20 to 1 for both frequencies. At 837 MHz, the maximum measured SAR in the restrained rat brains was 51 W/kg/W in the cerebellum and 40 W/kg/W at the top of the cerebrum. An exposure system operating at 837 MHz is ready for in vivo biological effect studies of radio frequency fields from portable cellular telephones. Two‐tenths of a watt input power to the loop antenna will produce 10 W/kg maximum SAR, and an estimated 4.8 W/kg average brain SAR in a 300 g medium size rat. Bioelectromagnetics 20:75–92, 1999. © 1999 Wiley‐Liss, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号