首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method based on microdialysis sampling and capillary liquid chromatography with electrochemical detection that allows in vivo monitoring of met-enkephalin with 5-min temporal resolution is described. Sampling was achieved using a concentric microdialysis probe made from polycarbonate membrane material with a 20 kDa cut-off. This probe had an in vitro relative recovery for met-enkephalin of 63% at a dialysis flow-rate of 0.6 μl/min. Separations were performed using 7 cm×25 μm I.D. fused-silica capillary columns packed with 5 μm Alltima C18 particles. A carbon fiber microelectrode was used as the detector electrode. The mass detection limit for met-enkephalin with this system was 40 amol. With on-column preconcentration, up to 2 μl of sample could be loaded onto the column resulting in concentration detection limits as low as 20 pM for met-enkephalin. Direct injection of dialysate, collected at 5-min intervals, allowed determination of met-enkephalin concentrations in the rat globus pallidus under basal and K+-induced depolarization conditions.  相似文献   

2.
Using capillary HPLC, femtomole amounts of recombinant DNA-derived human growth hormone (rhGH) have been successfully detected from solutions at nanomolar concentrations. The separation used capillaries of 15 cm × 320 μm I.D. and detection was with a UV absorbance detector containing a capillary Z-shaped flow-cell. A sample of rhGH that was recovered from rat serum was analyzed by capillary reversed-phase HPLC, using both acidic- and neutral-pH mobile phases, as well as by capillary ion-exchange chromatography. When compared to HPLC separations performed at flow-rates of 1 ml/min, the sensitivity of the detection was increased 200 times, without any loss in resolution. Sub-microgram amounts of rhGH were also analyzed by tryptic mapping using capillary HPLC and peptides were identified by capillary LC—MS.  相似文献   

3.
A modified capillary electrophoretic method for the determination of nitric oxide correlated nitrate in several tissue homogenates is described in this study. The method was developed using a running buffer consisting of 200 mM lithium chloride and 10 mM borate buffer at pH 8.5, in a fused-silica column total 82 cm, effective 43 cm length and 75 μm I.D. The signal was measured at 214 nm and controlled current of 200 μA (equivalent to 12.7 kV) was applied in the reversed polarity direction. The sample was injected by vacuum pressure 50 ms (25 nl). In these conditions, bromide as internal standard and nitrate appeared at 7.2 and 8.9 min, respectively. Whole validation procedures were applied and satisfactory results were obtained. The nitrate levels of the tissue homogenates of control and -NAME applied (heart, brain, kidney, stomach, lung, testis and liver) were monitored by the present method and it was decided that the method is precise and accurate.  相似文献   

4.
An oxygen-insensitive microscale biosensor for methane was constructed by furnishing a previously described biosensor with an oxygen guard. The guard consisted of a glass capillary containing heterotrophic bacteria, which consumed oxygen diffusing through the tip membrane, thus preventing it from diffusing into the methane-sensing unit. Oxygen microprofiles were measured through the oxygen guard capillary, demonstrating the principle and limitations of the method. When the tip of the guard capillary was exposed to 100% oxygen at 21°C, heterotrophic oxygen consumption prevented oxygen from diffusing further than 170 μm into the capillary, whereas atmospheric levels of oxygen were consumed within 50 μm. The capacity of the oxygen guard for scavenging oxygen decreased with decreasing temperature, and atmospheric levels of oxygen caused oxygen penetration to 200 μm at 5°C. The sensors could be manufactured with tip diameters as small as 25 μm, and response times were about 1 min at room temperature. Pore water profiles of methane concentrations in a rice paddy soil were measured, and a strong correlation between the depths of oxygen penetration and methane appearance was observed as a function of the light regimen; this finding confirmed the role of microbenthic photosynthesis in limiting methane emissions from surfaces of waterlogged sediments and soils.  相似文献   

5.
Nitrite and nitrate levels in physiological fluids are commonly used as an index of nitric oxide production. We developed simple and rapid method for the determination of these anions by capillary zone electrophoresis employing borate buffer (pH 10, 100 mmol/l) as running electrolyte. The anions were analyzed in plasma and cerebrospinal fluid (CSF) without deproteinization of the samples. Electrophoresis was carried out in a capillary (36.5 cm×75 μm) at a potential of 15 kV, with on-column UV detection at 214 nm. Mean retention times for nitrite and nitrates were 4.631 and 5.152 min, respectively. The method was linear (r=0.999) within a 1–500 μmol/l concentration range. Physiological levels of nitrate in plasma (40.2 μmol/l) and CSF (15.3 μmol/l) could be determined with good precision (coefficients of variation <6%) and accuracy (recoveries of added nitrate to plasma and CSF were 97.4 and 104.5%, respectively). Measurements of the physiological levels of nitrite in plasma (6.1 μmol/l) and CSF (0.9 μmol/l) were less precise and accurate.  相似文献   

6.
An ethanolic extract of cloves was analyzed by gas chromatography directly to identify eugenol and other major phenolic compounds without previous separation of other components. Separation was performed on a fused-silica capillary column of 30 mx0.53 mm I.D., 0.53 μm film thickness. The detector was a flame ionization detector. Helium gas at a flow-rate of 3 ml/min was used as a carrier gas. The analysis were performed with linear temperature programming. Nine components were detected and special attention was given to the major phenolic compound, eugenol.  相似文献   

7.
We applied micellar electrokinetic capillary chromatography to simultaneous separation and determination of nitrazepam and its major metabolites, 7-aminonitrazepam and 7-acetamidonitrazepam, in spiked urine. Prior to electrophoresis, the three compounds were successfully extracted from the spiked urine with commercial disposable solid-phase cartridges. The optimum running buffer for the separation was prepared by combining 85 parts of 60 mM sodium dodecyl sulphate—6 mM phosphate—borate, adjusted to pH 8.5, with 15 parts of methanol. The separation order, completed within 25 min, was 7-aminonitrazepam > 7-acetamidonitrazepam > nitrazepam, at an applied potential of 20 kV. We obtained reproducible electropherograms in successive repetitions, and few other peaks or interferences appeared in the electropherogram. The detection limits of the three compounds were 50–100 pg (0.1–0.2 μg/ml of analyte in spiked urine), and the recoveries were 78.9–100.8% for 1 μg/ml and 84.1–100.3% for 5 μg/ml. The application of this method to forensic or clinical samples is demonstrated.  相似文献   

8.
Plasma phenobarbital (PB) concentrations in rat offspring were determined using a 9 μl capillary by high-performance liquid chromatography (HPLC). Capillary plasma which was put into a Bond Elut® cartridge column by using 1 ml of 0.01 M KH2PO4 was applied to the column with 50 μl of 2 μg/ml of acetanilide (internal standard, I.S.). After washing the column, PB and I.S. were eluted with methanol and injected into the HPLC system. There were excellent linear correlation between the amount of PB and length of the capillary at three different concentrations. Calibration for PB was linear in the range of 0–50 μg/ml. The coefficients of variation were 3.4–5.0% and 5.9–7.5% in the within-day and between-day assays, respectively. The extraction recovery rates were 87.5–105.4%. By this method, it was possible to measure plasma PB concentrations in rat offspring without killing. These results suggested that this method is very useful to determine the plasma PB concentration derived from mother’s milk in newborn rats.  相似文献   

9.
Methylhippuric acid isomers (MHAs), urinary metabolites of xylenes, were determined, after clean-up by C18-SPE and esterification with hexafluoroisopropanol and diisopropylcarbodiimide, by GC with ECD detection, on an SPB-35 capillary column (30 m, 0.32 mm I.D., 0.25 μm film thickness, β=320). S-benzyl-mercapturic acid was used for internal standardization. Chromatographic conditions were: oven temperature 162°C, for 14.2 min; ramp by 30°C/min to 190°C, for 3.5 min; ramp by 30°C/min to 250°C, for 4 min; helium flow rate: 1.7 ml/min; detector and injector temperature: 300°C. The sample (1 μl) was injected with a split injection technique (split ratio 5:1). MHA recovery was >95% in the 0.5–20 μmol/l range; the limit of detection was <0.25 μmol/l; day-to-day precision, at 2 μmol/l, was Cv<10%. Urinary MHAs were determined in subjects exposed to different low-level sources of xylenes: (a) tobacco smoking habit and (b) BTX urban air pollution (airborne xylene ranging from 0.1 to 3.7 μmol/m3). Study (a) showed a significant difference between urinary MHA median excretion values of nonsmokers and smokers (4.6 μmol/l vs. 8.1 μmol/l, p<0.001). Study (b) revealed a significant difference between indoor workers and outdoor workers (4.3 μmol/l vs. 6.9 μmol/l, p<0.001), and evidenced a relationship between MHAs (y, μmol/mmol creatinine) and airborne xylene (x, μmol/m3) (y=0.085+0.34x; r=0.82, p<0.001, n=56). Proposed biomarkers could represent reliable tools to study very low-level exposure to aromatic hydrocarbons such as those observed in the urban pollution due to vehicular traffic or in indoor air quality evaluation.  相似文献   

10.
An automated on-line ionic detergent removal pre-column system coupled to capillary liquid chromatography-electrospray mass spectrometry is described. The system involves two micro precolumns, composed of a specific ionic detergent trapping column and a preconcentration column, respectively, and a packed 300 μm I.D. analytical column. Sample loading to the micro precolumns and regeneration of the detergent trapping column were performed at a flow-rate of 50 μl/min, while the flow-rate through the analytical column was set at 5.0 μl/min. Ionic detergent-containing tryptic-digested protein samples were directly applied to the micro precolumns without sample pretreatment and were analysed by UV absorption detection and electrospray mass spectrometry. The presented system allows for the fully automated removal of SDS with virtually no loss in protein/peptides. Maximum SDS load and breakthrough have been determined. Excellent protein recovery and complete removal of SDS is found. The chromatographic separation after SDS removal was completely restored and equalled the reference chromatogram. Mass spectral data confirm these findings. Finally, this technique allows for SDS removal from minute protein samples without the need for any sample handling.  相似文献   

11.
An original method based upon high-performance liquid chromatography coupled to ion spray mass spectrometry (HPLC-ISP-MS) has been developed for the identification and quantification of colchicine (COL) in human blood, plasma or urine. After single-step liquid-liquid extraction by dichloromethane at pH 8.0 using tofisopam (TOF) as an internal standard, solutes are separated on a 5-μm C18 Microbore (Alltech) column (250×1.0 mm, I.D.), using acetonitrile-2 mM NH4COOH, pH 3 buffer (75:25, v/v) as the mobile phase (flow-rate 50 μl/min). Detection is done by a Perkin-Elmer Sciex API-100 mass analyzer equipped with a ISP interface (nebulizing and curtain gas: N2, quality U; main settings: ISP, +4.0 kV; OR, +50 V; Q0, −10 V; Q1, −13 V; electron multiplier, +2.2 kV); MS data are collected as either total ion current (TIC, m/z 100–500 or 380–405), or selected ion monitoring (SIM) at m/z 400 and 383 for COL and TOF, respectively. COL mass spectrum shows a prominent molecular ion [M+H]+ at m/z 400. Increasing OR potential fails to provide a significant fragmentation. Retention times are 2.70 and 4.53 min for COL and TOF, respectively. The quantification method shows a good linearity (r = 0.998) over a concentration range from 5 to 200 ng/ml. The lower limit of detection in SIM mode is 0.6 ng/ml COL, making the method convenient for both clinical and forensic purposes.  相似文献   

12.
A capillary zone electrophoresis method for the separation and analysis of nitrate and nitrite in water and urine was developed. No interference in the electropherogram from other anions is observed by using a polyacrylamide-coated column with a modified phosphate buffer at pH 3 for the separation, and UV absorption at 214 nm for the detection. The method does not require sample pretreatment or the use of organic solvents. The limit of detection for each analyte (S/N = 3), using a 75 μm I.D. capillary, is 0.5 μg/ml. Urine samples require 40-fold dilution in order to maintain migration time reproducibility to within 1% relative standard deviation.  相似文献   

13.
A method for separating and detecting retinoids by reversed-phase capillary liquid chromatography with amperometric electrochemical detection is described. Packed columns with an inner diameter of 180 μm were employed for the separation using a C18 stationary phase and a mobile phase containing acetonitrile-water-methanol (65:32.5:2.5, v/v/v) with 1% tetrabutylammonium perchlorate and 0.174 M acetate buffered at pH 5. The detection cell consisted of a carbon fiber barrel electrode held at 0.9 V versus an Ag/AgCl reference. Injection volumes of 2 μl produced detection limits of 2.73, 0.472, 0.428, and 0.267 fmol (or 410, 64.1, 60.9, and 38.2 pg ml−1) for 13-cis-retinoic acid, all-trans-retinoic acid, retinaldehyde, and retinol, respectively. This represents an improvement in detection limits of at least three orders of magnitude for similar analyses using liquid chromatography and UV absorbance detection. The detector signal was linear over two orders of magnitude of analyte concentration. Retinoid concentrations in bovine serum were determined and found to be in good agreement with previously reported values.  相似文献   

14.
trans,trans-Muconic acid (1,3-butadiene-1,4-dicarboxylic acid, MA), a minor urinary metabolite of benzene exposure, was determined, after clean-up by solid-phase anion-exchange chromatography, by reversed-phase HPLC on a C18 column (5 × 0.46 cm I.D., 3 μm particle size), using formic acid-tetrahydrofuran-water (14:17:969) as mobile phase and UV detection at 263 nm. The recovery of MA from spiked urine was > 95% in the 50–500 μg/l range; the quantification limit was 6 μg/l; day-to-day precision, at 300 μg/l, C.V. = 9.2%; the run time was less than 10 min. Urinary MA excretion was measured in two spot urine samples of 131 benzene environmentally exposed subjects: midday values obtained in non-smokers (mean±S.D.=77±54 μg/l, N = 82) were statistically different from those of smoerks (169±85 μg/l, N = 30) (P<0.0001); each group showed a statistically significant increase between MA excretion in midday over morning samples. Moreover, in subjects grouped according to tobacco-smoke exposure level, median values of MA were positively associated with and increased with daily smoking habits.  相似文献   

15.
Solid-phase microextraction (SPME) was investigated as a sample preparation method for assaying the neuroleptic drug clozapine in human plasma. A mixture of human plasma, water, loxapine (as internal standard) and aqueous NaOH was extracted with a 100-μm polydimethylsiloxane (PDMS) fiber (Supelco). Desorption of the fiber was performed in the injection port of a gas chromatograph at 260°C (HP 5890; 30 m×0.53 mm I.D., 1 μm film capillary; nitrogen–phosphorous selective detection). Fibers were used repeatedly in up to about 75 analyses. The recovery was found to be 3% for clozapine from plasma after 30 min of extraction. However, in spite of the low recovery, the analyte was well separated and the calibration was linear between 100 and 1000 ng/ml. The within-day and between-day precision was consistently about 8 to 15% at concentrations of 200 ng/ml to 1000 ng/ml. No interfering drug was found. The limit of detection was 30 ng/ml. The sample volume was 250 μl. The influence of the concentration of proteins, triglycerides and salt, i.e., changes in the matrix on the peak areas and peak-area ratios was studied. The method is not impaired by physiological changes in the composition of the matrix. Good agreement was found with a liquid–liquid extraction–gas–liquid chromatography (LLE–GLC) standard method and an on-line column-switching high-performance liquid chromatography (HPLC) method for patients’ samples and spiked samples, respectively. It is concluded that the method can be used in the therapeutic drug monitoring of clozapine because the therapeutic window of clozapine is from 350 to 600 ng/ml.  相似文献   

16.
A quick, simple and reliable analysis method has been developed in order to determine berenil, phenamidine, diampron and dibromopropamidine by capillary zone electrophoresis in samples of serum and urine. In order to define the operation parameters in CZE, we have carried out a study on how the apparent electrophoretic mobility (μapp) varies when pH, buffer concentration, voltage and temperature are modified. Ohm’s law plot has been studied, too. With the data obtained from this study we have determined the optimum work conditions, which are: citrate buffer 25 mM, pH=3.70, 14 kV, 30°C, wavelength of the UV detector: 200 nm, capillary tube: 570 mm×75 μm. Under these conditions, all the products appear in times between: 7.6 min phenamidine and 8.8 min dibromopropamidine, limits of detection being: berenil: 0.50, phenamidine: 0.25, diampron: 0.40 and dibromopropamidine: 0.80 μg ml−1. We have carried out a recovery study with three kinds of extraction cartridges: Sep-pak C-18 plus, Sep-pak C-8 plus and Oasis HBL for each one of the products in blood and urine.  相似文献   

17.
A method for the determination of hexahydrophthalic acid, a metabolite of hexahydrophthalic anhydride, in human urine has been developed. The urine was worked-up by liquid—solid extraction, esterified with boron trifluoride—methanol, and analysed by capillary gas chromatography and selected-ion monitoring. Hexadeuterium-labelled hexahydrophthalic acid was used as the internal standard. The precision was 4% at 0.7 μg/ml and 5% at 0.07 μg/ml. The recovery of the acid for the overall method was 101% at 0.07 μg/ml of urine (with a coefficient of variation of 4%) and 95% at 0.7 μg/ml (coefficient of variation 2%). The limit of detection was 20 ng/ml urine.  相似文献   

18.
The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography–electrospray ionization mass spectrometry (LC–ESI-MS) was evaluated for the determination of ranitidine. In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from the sample directly into an open tubular capillary column by repeated aspirate/dispense steps. In order to optimize the extraction of ranitidine, several in-tube SPME parameters such as capillary column stationary phase, extraction pH and number and volume of aspirate/dispense steps were investigated. The optimum extraction conditions for ranitidine from aqueous samples were 10 aspirate/dispense steps of 30 μl of sample in 25 mM Tris–HCl (pH 8.5) with an Omegawax 250 capillary column (60 cm×0.25 mm I.D., 0.25 μm film thickness). The ranitidine extracted on the capillary column was easily desorbed with methanol, and then transported to the Supelcosil LC-CN column with the mobile phase methanol–2-propanol–5 M ammonium acetate (50:50:1). The ranitidine eluted from the column was determined by ESI-MS in selected ion monitoring mode. In-tube SPME followed by LC–ESI-MS was performed automatically using the HP 1100 autosampler. Each analysis required 16 min, and carryover of ranitidine in this system was below 1%. The calibration curve of ranitidine in the range of 5–1000 ng/ml was linear with a correlation coefficient of 0.9997 (n=24), and a detection limit at a signal-to-noise ratio of three was ca. 1.4 ng/ml. The within-day and between-day variations in ranitidine analysis were 2.5 and 6.2% (n=5), respectively. This method was also applied for the analyses of tablet and urine samples.  相似文献   

19.
A reversed-phase high-performance liquid chromatographic method for the determination of the enantiomers of atenolol in rat hepatic microsome has been developed. Racemic atenolol was extracted from alkalinized rat hepatic microsome by ethyl acetate. The organic layer was dried with anhydrous sodium sulfate and evaporated using a gentle stream of air. Atenolol racemic compound was derivatized with 2,3,4,6-tetra-O-acetyl-β- -glycopyranosyl isothiocyanate at 35°C for 30 min to form diastereomers. After removal of excess solvent, the diastereomers were dissolved in phosphate buffer (pH 4.6)–acetonitrile (50:30). The diastereomers were separated on a Shimadzu CLC-C18 column (10 μm particle size, 10 cm×0.46 cm I.D.) with a mobile phase of phosphate buffer–methanol–acetonitrile (50:20:30, v/v) at a flow-rate of 0.5 ml/min. A UV–VIS detector was operated at 254 nm. For each enantiomer, the limit of detection was 0.055 μg/ml (signal-to-noise ratio 3) and the limit of quantification (signal-to-noise ratio 10) was 0.145 μg/ml (RSD <10%). In the range 0.145–20 μg/ml, intra-day coefficients of variation were 1.0–7.0% and inter-day coefficients of variation were 0.4–16.5% for each enantiomer. The assay was applied to determine the concentrations of atenolol enantiomers in rat hepatic microsome as a function of time after incubation of racemic atenolol.  相似文献   

20.
Capillary electrophoresis (CE) with laser-induced fluorescence detection was applied to quantify daunorubicin and daunorubicinol in plasma. Separation was carried out in a 47 cm×50 μm I.D. fused-silica capillary, with a running buffer, pH 5 containing 60 μM spermine and 70% acetonitrile. Sample preparation was done either by protein precipitation with acetonitrile or by liquid–liquid extraction. The assay can be applied in a concentration range from 40 mg/l down to 2 μg/l for daunorubicin and from 1 mg/l to 2 μg/l for daunorubicinol. Precision and accuracy were between 2.9 and 14.5% (n=6) on 1 day and between 1.0 and 14.7% from day to day (n=6) for both analytes. Thus, the CE method enables precise and accurate quantification of daunorubicin and daunorubicinol in small sample volumes over a wide concentration range.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号