首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
A sensitive method for the determination of stavudine in plasma was developed, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted from plasma with Waters, Sep-Pak Vac, 100 mg, tC(18) solid-phase extraction (SPE) columns. Chromatography was performed on a Supelco Discovery C(18), 5 microm, 150 x 2 mm column with a mobile phase consisting of ammonium acetate (0.01 M)-acetonitrile-methanol (800:100:100, v/v/v) at a flow-rate of 0.3 ml/min. Detection was achieved by an Applied Biosystems API 2000 mass spectrometer (LC-MS-MS) set at unit resolution in the multiple reaction monitoring mode (MRM). Atmospheric pressure chemical ionization (APCI) was used for ion production. The mean recovery for stavudine was 94% with a lower limit of quantification set at 4 ng/ml. This assay method makes use of the increased sensitivity and selectivity of mass spectrometric (MS-MS) detection to allow for a more rapid (extraction and chromatography) and selective method for the determination of stavudine in human plasma than has previously been described.  相似文献   

2.
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC/MS/MS) method for the determination of tiropramide in human plasma was developed. Tiropramide and internal standard, cisapride were extracted from human plasma by liquid-liquid extraction and analyzed on a Luna C8 column with the mobile phase of acetonitrile-ammonium formate (10mM, pH 4.5) (50:50, v/v). The analytes was detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r=0.998) over the concentration range of 2.0-200 ng/ml. The intra- and inter-assay coefficients of variation ranged from 2.8 to 7.8 and 6.7 to 8.9%, respectively. The recoveries of tiropramide ranged from 50.2 to 53.1%, with that of cisapride (internal standard) being 60.9+/-5.3%. The lower limit of quantification for tiropramide was 2.0 ng/ml using 100 microl plasma sample. This method was applied to the pharmacokinetic study of tiropramide in human.  相似文献   

3.
Meloxicam was quantified in human plasma after a single 15 mg oral dose of the drug was given to 26 healthy volunteers. An Applied Biosystems Sciex API 2000 triple quadrupole mass spectrometer in multiple reaction monitoring (MRM) mode, using TurboIonSpray (TIS) in the positive ion mode, was used. Protein precipitation with acetonitrile was followed by C(18) reverse phase liquid chromatography and tandem mass spectrometry. The mean recovery for meloxicam was 92% with a lower limit of quantification of 8.96 ng/ml. Piroxicam was used as the internal standard. This assay method makes use of the increased sensitivity and selectivity of tandem mass spectrometry (MS-MS) detection to allow for a more rapid (extraction and chromatography) and selective method for the determination of meloxicam in human plasma than has previously been described.  相似文献   

4.
A novel, highly sensitive method for the determination of pilocarpic acid (PA) in human plasma is described. In addition, the method provides for the conversion of the lactone, pilocarpine (P), to PA so that a total drug presence can be determined. Using novel high-performance liquid chromatographic conditions capable of separating P, isopilocarpine (I-P), PA and isopilocarpic acid (I-PA) from each other and from endogenous plasma impurities, it was confirmed that P exclusively and quantitatively converts to PA in heparinized human plasma during storage. For the determination of PA, the selective extraction of PA from protein-free plasma was accomplished using two different solid-phase extraction (SPE) cartridges in two consecutive SPE steps. After extraction, PA was lactonized with trifluoroacetic acid back to P, and both P and an internal standard were acylated using heptafluorobutyric anhydride (HFBA). The trifluoroacetylated derivatives were monitored using gas chromatography (GC) with mass spectrometric (MS) detection. This procedure allowed the sensitive and reliable determination of PA with a limit of quantification (LOQ) of 1 ng/ml, which could not be achieved using previously described methods. The assay was validated in the concentration range of 1 to 10 ng/ml with an intra-day precision (expressed as the coefficient of variation, C.V.) ranging from 9.9 to 0.5%. Inter-day precision for the quality control standard at 2.5 ng/ml showed a C.V. of 10.2%. Accuracy ranged from 94 to 102%. The assay was used to monitor the maximum systemic exposure to P, administered by the ocular route, in terms of total plasma PA (P and PA).  相似文献   

5.
A highly sensitive and specific liquid chromatography/tandem mass spectrometric (LC-MS/MS) method for investigating the pharmacokinetics of adrafinil in rats was developed. Rat serum pretreated by solid-phase extraction (SPE) was analyzed by LC-MS/MS with an electrospray ionization (ESI) interface. The mobile phase consisted of acetonitrile:water:acetic acid (35:65:0.1, v/v/v) in an isocratic elution mode pumped at 1.0ml/min. The analytical column (250mmx4.6mm i.d.) was packed with Kromasil C(18) material (5.0mum). The standard curve was linear from 16.5 to 5000ng/ml. The assay was specific, accurate (R.S.D.<2.6%), precise and reproducible (within- and between-day precisions R.S.D. <7.0% and <9.0%, respectively). Adrafinil in rat serum was stable over three freeze-thaw cycles at ambient temperature for 6h. The method had a lower limit of quantitation of 16.5ng/ml, which offered high sensitivity for the determination of adrafinil in serum. The method was successfully applied to pharmacokinetic studies of adrafinil after an oral administration to rats.  相似文献   

6.
We describe here the first method for the enantioselective analysis of the calcium antagonist lercanidipine in human plasma by high performance liquid chromatography (HPLC) employing tandem mass spectrometric (MS) detection. Routine determination of lercanidipine enantiomers in human plasma in the working range of 0.025-50.0 ng ml(-1) plasma for each enantiomer with an accuracy and precision less than 15% was possible. Application of the method to a stereospecific study of the pharmacokinetics showed that plasma levels after an oral dose of rac-lercanidipine administered to a healthy volunteer were found to be higher for the (S)-enantiomer.  相似文献   

7.
A sensitive liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for the determination of rosuvastatin in human plasma. The plasma samples were prepared using liquid-liquid extraction with ethyl ether. Chromatographic separation was accomplished on a Zorbax XDB-C18 (150 mm x 4.6 mm i.d., 5 microm) column. The mobile phase consisted of methanol-water (75:25, v/v, adjusted to pH 6 by aqueous ammonia). Detection of rosuvastatin and the internal standard (IS) hydrochlorothiazide was achieved by ESI MS/MS in the negative ion mode. The lower limit of quantification was 0.020 ng/ml by using 200 microl aliquots of plasma. The linear range of the method was from 0.020 to 60.0 ng/ml. The intra- and inter-day precisions were lower than 8.5% in terms of relative standard deviation (RSD), and the accuracy was within -0.3 to 1.9% in terms of relative error (RE). Compared with the existing methods, the validated method offered increased sensitivity. The method was successfully applied for the evaluation of pharmacokinetics of rosuvastatin after single oral doses of 5, 10 and 20 mg rosuvastatin to 10 healthy volunteers.  相似文献   

8.
Two liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) methods are described, one for the quantitative determination of risperidone and the enantiomers of its active metabolite 9-hydroxyrisperidone (paliperidone) in human plasma and the other for the determination of the enantiomers of 9-hydroxyrisperidone in human urine. The plasma method is based on solid-phase extraction of 200 microl of sample on a mixed-mode sorbent, followed by separation on a cellulose-based LC column with a 13.5-min mobile phase gradient of hexane, isopropanol and ethanol. After post-column addition of 10 mM ammonium acetate in ethanol/water, detection takes place by ion-spray tandem mass spectrometry in the positive ion mode. Method validation results show that the method is sufficiently selective towards the enantiomers of 7-hydroxyrisperidone and capable of quantifying the analytes with good precision and accuracy in the concentration range of 0.2-100 ng/ml. An accelerated (run time of 4.3 min) and equally valid method for the enantiomers of 9-hydroxyrisperidone alone in plasma is obtained by increasing the mobile phase flow-rate from 1.0 to 2.0 ml/min and slightly adapting the gradient conditions. The urine method is based on the same solid-phase extraction and chromatographic approach as the accelerated plasma method. Using 100 microl of sample, (+)- and (-)-9-hydroxyrisperidone can be quantified in the concentration range 1-2000 ng/ml. The accelerated method for plasma and the method for urine can be used only when paliperidone is administered instead of risperidone, as there is insufficient separation of the 9-hydroxy enantiomers from the 7-hydroxy enantiomers, the latter ones being present only after risperidone administration.  相似文献   

9.
A rapid, sensitive and selective method has been developed for the quantification of plasma concentrations of neuromuscular blocking drug, rocuronium, using gas chromatography with mass spectrometric detection. 3-Desacetylvecuronium served as the internal standard. The method involved iodide ion pair formation and a single-step liquid–liquid extraction with dicholoromethane. This method also permits simultaneous determination of its putative metabolite, 17-desacetylrocuronium, although the high detection limit for the metabolite limits the practical application of this method in pharmacokinetic study of the metabolite. The extraction efficiency was 75% for rocuronium and 50% for 17-desacetylrocuronium. The limit of quantification was 26 ng/ml for rocuronium and 870 ng/ml for its metabolite. The assay was used successfully in a patient undergoing liver transplantation and receiving rocuronium as a constant rate infusion and in a patient undergoing general elective surgery receiving the drug as an intravenous bolus. This assay is a time-saving alternative to published gas or liquid chromatographic methods for assaying rocuronium.  相似文献   

10.
An assay, based on pre-column derivatization and micro-high-performance liquid chromatography–tandem mass spectrometry, was developed for the determination of the GABAB agonist CGP 44532 in rat plasma. CGP 44532, a highly polar 3-amino-2(S)-hydroxypropylmethylphosphinic acid, presented difficulties in developing a chromatographic method for the analysis of the compound in rat plasma. Instead of analyzing the target compound directly, it was derivatized prior to separation to a 4-nitrobenzylcarbamate isopropyliden derivative. In order to reach the required quantitation limit, on-line solid-phase extraction was utilized for sample clean-up and reversed-phase micro-column high-performance liquid chromatography, for separation of the plasma samples. The separated compounds were detected by negative electrospray tandem mass spectrometry in selected reaction monitoring mode. The derivatives show good chromatographic and mass spectrometric properties and both the target compound and the internal standard, could be eluted as symmetrical peaks with good signal/noise ratio. The MS–MS detection was selective and sensitive due to the straight fragmentation pattern. After injection of 200-μl sample aliquots, the limit of quantification was 10 ng ml−1. The analytical assay is useable in the range of 10–500 ng ml−1.  相似文献   

11.
A sensitive method for the determination of Delta(9)-tetrahydrocannabinol and its metabolites, 11-nor-Delta(9)-tetrahydrocannabinol-9-carboxylic acid and 11-hydroxy-Delta(9)-tetrahydrocannabinol, in rat and guinea pig plasma was developed using high-performance liquid chromatographic separation with electrospray ionization mass spectrometry detection and a simple liquid-liquid extraction technique. The mean recoveries for Delta(9)-tetrahydrocannabinol, 11-nor-Delta(9)-tetrahydrocannabinol-9-carboxylic acid, and 11-hydroxy-Delta(9)-tetrahydrocannabinol were 96, 92, and 85%, respectively. The lower limit of quantification (LLOQ) for all three compounds was 5 ng/ml and the limit of detection (LOD) was 2 ng/ml. This assay method utilizes the increased sensitivity and selectivity of mass spectrometric (MS) detection and a simple extraction step for the determination of Delta(9)-tetrahydrocannabinol and its metabolites in plasma, and thus yields a more efficient pharmacokinetic analysis method than has previously been described.  相似文献   

12.
A sensitive, specific and rapid liquid chromatographic/tandem mass spectrometric (LC/MS/MS) assay for the determination of allylestrenol in human plasma was established. Plasma samples were extracted by tert-butyl ether and separated by LC/MS/MS using a Phenomenex Curosil-PFP column (250 mm x 4.6 mm ID, dp 5 microm) with a mobile phase of methanol-water (95:5, v/v). The analytes were monitored with atmospheric pressure chemical ionization (APCI) by selected reaction monitoring (SRM) mode. The linear calibration curves covered a concentration range of 0.04-20.0 ng/mL with lower limit of quantification (LLOQ) at 0.04 ng/mL. The mean extraction recovery of allylestrenol was greater than 81.8%. The intra- and inter-day precisions were less than 1.3% and 3.1% respectively, determined from quality control (QC) samples of three representative concentrations. The method has been successfully applied to determining the plasma concentration of allylestrenol and a clinical pharmacokinetics study in healthy Chinese female volunteers.  相似文献   

13.
A rapid, sensitive and selective hydrophilic interaction liquid chromatography-tandem mass spectrometric (HILIC-MS/MS) method for the determination of levosulpiride in human plasma was developed. Levosulpiride and internal standard, tiapride were extracted from human plasma with ethyl acetate at pH 11 and analyzed on an Atlantis HILIC silica column with the mobile phase of acetonitrile-ammonium formate (190 mM, pH 3.0) (94:6, v/v). The analytes were detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r = 0.999) over the concentration range of 1.00-200 ng/ml. The lower limit of quantification for levosulpiride was 1.00 ng/ml using 100 microl plasma sample. The coefficient of variation and relative error for intra- and inter-assay at three quality control (QC) levels were 3.8-9.1 and -2.9 to -0.1%, respectively. The recoveries of levosulpiride ranged from 80.5 to 87.4%, with that of tiapride (internal standard) being 84.6%. This method was successfully applied to the pharmacokinetic study of levosulpiride in humans.  相似文献   

14.
A simple method using a one-step liquid-liquid extraction (LLE) with methyl-t-butyl ether (MTBE) followed by high-performance liquid chromatography (HPLC) with negative-ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of cilnidipine in human plasma using benidipine as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 491.1>121.8 for cilnidipine and m/z 504.2>122.1 for IS, respectively. Analytes were chromatographed on a CN column by isocratic elution using 10mM ammonium acetate buffer-methanol (30:70, v/v; adjusted with acetic acid to pH 5.0). Results were linear (r2=0.99998) over the studied range (0.1-20ng/ml) with a total LC-MS/MS analysis time per run of 3min. The developed method was validated and successfully applied to a cilnidipine bioequivalence study in 24 healthy male volunteers.  相似文献   

15.
A rapid, selective, sensitive and reproducible liquid chromatographic method with tandem mass spectrometric detection has been developed and validated for the analysis of a new specific bradycardic agent, ivabradine (S 16257) and six potentially active metabolites in human plasma. Isolation of these compounds and of the internal standard was performed by an automated solid-phase extraction system using Oasis cartridges. Separation and detection of ivabradine and its metabolites were achieved using a C18 column and a MS–MS detector with a positive electrospray ionization source. Ivabradine and its metabolites gave a linear response ranging from 0.1 or 0.2 to 20 ng/ml and the limits of quantitation ranged from 0.1 to 0.2 ng/ml using a 0.5 ml plasma sample size. A complete validation demonstrated the method to be accurate, precise and specific for the simultaneous quantification of ivabradine and its metabolites in human plasma. The method was subsequently applied to the quantitative determination of ivabradine and its metabolites in human plasma samples from healthy volunteers participating in a clinical study to provide pharmacokinetic data.  相似文献   

16.
A sensitive and selective liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method was developed for the determination of cefdinir in human plasma. After a simple protein precipitation using trichloracetic acid, the post-treatment samples were applied to a prepacked RP18 Waters SymmetryShield column interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of methanol-water-formic acid (25:75:0.075, v/v/v). The analyte and I.S. cefaclor were both detected by the use of selected reaction monitoring mode. The method was linear in the concentration range of 5-2,000 ng/ml. The lower limit of quantification was 5 ng/ml. The intra- and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 4.3%. The accuracy determined at three concentrations (36, 360 and 1,800 ng/ml for cefdinir) ranged from 99.6 to 106.7% in terms of recovery. The chromatographic run time for each plasma sample was less than 3 min. The method herein described was successfully applied for the evaluation of pharmacokinetic profiles of cefdinir capsule in 12 healthy volunteers.  相似文献   

17.
A liquid chromatography/tandem mass spectrometric (LC/MS/MS) assay was developed for the quantitative determination of salirasib (S-trans,trans-farnesylthiosalicylic acid, FTS) in human plasma. Sample pretreatment involved liquid-liquid extraction with methyl t-butyl ether of 0.5-mL aliquots of lithium heparin plasma spiked with the internal standard, S-trans,trans-5-fluoro-farnesylthiosalicylic acid (5-F-FTS). Separation was achieved on Waters X-Terra C(18) (50 mm x 2.1 mm i.d., 3.5 microm) at room temperature using isocratic elution with acetonitrile/10 mM ammonium acetate buffer mobile phase (80:20, v/v) containing 0.1% formic acid at a flow rate of 0.20 mL/min. Detection was performed using electrospray MS/MS by monitoring the ion transitions from m/z 357.2-->153.0 (salirasib) and m/z 375.1-->138.8 (5-F-FTS). Calibration curves were linear in the concentration range of 1-1000 ng/mL. A 5000 ng/mL sample that was diluted 1:10 (v/v) with plasma was accurately quantitated. The values for both within day and between day precision and accuracy were well within the generally accepted criteria for analytical method (<8.0%). This assay was subsequently used for the determination of salirasib concentrations in plasma of cancer patients after oral administration of salirasib at a dose of 400 mg.  相似文献   

18.
An accurate, sensitive, reproducible, and selective liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for determination of aripiprazole and its main metabolite, OPC-14857, in human plasma was developed and validated. Chromatographic separation was achieved isocratically on a C18 reversed-phase column within 7.5 min. The calibration curve, ranging from 0.1 to 100 ng/ml, was fitted to a 1/y2-weighted linear regression model. The assay showed no significant interference. Lower limit of quantitation (LLOQ) for both analytes was 0.1 ng/ml using 0.4 ml of plasma. Intra- and inter-assay precision and accuracy values for aripiprazole and OPC-14857 were within regulatory limits.  相似文献   

19.
Sensitive and selective methods based on high performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection were developed for the determination of vitamin D(3) in human serum. Derivatization of vitamin D(3) and its stable isotope labeled internal standard provided highly sensitive quantification and selective detection from endogenous compounds. Samples were prepared using the in-tube liquid-liquid extraction (LLE), 96-well plate LLE, and in-tip solid phase micro-extraction (SPME) in 96-well format. In all methods, the MS/MS detection was performed using Applied Biosystems-Sciex API 3000 tandem mass spectrometers interfaced with a heated nebulizer probe and operated in the positive ionization mode. Both tube and plate LLE methods achieved a lower limit of quantitation (LLOQ) of 0.5 ng/mL when 1.0 and 0.4 mL of human serum was processed, respectively, and were validated in the concentration range of 0.5-25 ng/mL; while for the in-tip SPME method, LLOQ was 5 ng/mL with only 0.1 mL of human serum required. Comparisons were made among three different methods, including precision and accuracy, sample throughput, recovery and matrix effects.  相似文献   

20.
This paper describes a rapid and sensitive method for the quantitation of 20(S)-protopanaxadiol (PPD) in human plasma based on high-performance liquid chromatography–tandem mass spectrometry (LC–MS/MS). The analyte and internal standard (I.S.), ginsenoside Rh2, were extracted from plasma by liquid–liquid extraction and separated on a Zorbax extend C18 analytical column using methanol–acetonitrile-10 mM ammonium acetate (47.5:47.5:5, v/v/v) as mobile phase. Detection was by tandem mass spectrometry using electrospray ionization in the positive ion mode and multiple reaction monitoring (MRM). The assay was linear over the concentration range 0.1–100.0 ng/ml with a limit of detection of 0.05 ng/ml. The method was successfully applied to a clinical pharmacokinetic study in healthy volunteers after a single oral administration of a PPD 25 mg capsule.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号