The separation of proteins on stationary phases consisting of a bound organic chelator and a chelated divalent transition metal has been studied as a function of (A) metal ion species; (B) mobile phase composition and pH; and (C) anion and cation concentration. Optimum separation was observed at alkaline pH on chelated nickel stationary phases. Ammonium and Tris salts reduced the affinity of the metal chelate packing for serum proteins. Halide ions caused the proteins to be more strongly bound to the stationary phase. High salt concentrations had only a small effect on the binding of serum proteins in the absence of amine containing buffers or salts. It was also observed that the ease of elution and the recovery of protein were dependent on pH and upon the presence of halides. The general order of elution of serum proteins, based on isoelectric focusing, was independent of metal ion species and elution conditions, suggesting that a single mechanism or a unique sequence of mechanisms was operative. The results suggest that ligand exchange is the major mechanism of separation under basic conditions and that hydrophobic effects are the result of the competition of nonnitrogen ions with ammonium ions or amines for ligand binding sites modifying or participating in protein binding. Protein binding studies under weak acidic conditions are also presented although the mechanism responsible for protein binding is unclear.  相似文献   

2.
It is hypothesized that metal ion-mediated adsorption of phosphorylated peptides on stationary phases of LC-columns is the major cause for their frequently observed poor detection efficiency in LC-MS. To study this phenomenon in more detail, sample solutions spiked with metal ion-mobilizing additives were analyzed by reversed phase μLC-ICP-MS or nanoLC-ESI-MS. Using μLC-ICP-MS, metal ions were analyzed directly as atomic ions. Using electrospray ionization, either metal ion chelates or phosphopeptide standard mixtures injected in subpicomole amounts were analyzed. Deferoxamine, imidazole, ascorbate, citrate, EDTA, and the tetrapeptide pSpSpSpS were tested as sample additives for the interlinked purposes of metal ion-mobilization and improvement of phosphopeptide recovery. Iron probably represents the major metal ion contamination of reversed phase columns. Based on the certified iron level in LC-grade solvents, a daily metal ion load of >10 pmol was estimated for typical nanoLC flow rates. In addition, phosphopeptide fractions from IMAC columns were identified as source for metal ion contamination of the LC column, as demonstrated for Ga3+-IMAC. The three metal ion-chelating additives, EDTA, citrate and pSpSpSpS, were found to perform best for improving the LC recovery of multiply phosphorylated peptides injected at subpicomole amounts. The benefits of metal ion-mobilizing LC (mimLC) characterized by metal ion complexing sample additives is demonstrated for three different instrumental setups comprising (a) a nanoUPLC-system with direct injection on the analytical column, (b) a nanoLC system with inclusion of a trapping column, and (c) the use of a HPLC-Chip system with integrated trapping and analytical column.  相似文献   

3.
The chromatographic behavior of monoclonal antibodies (MAbs) of immunoglobulin (Ig) M class against mutant (T103I) amidase from Pseudomonas aeruginosa was investigated on immobilized metal chelates. The effect of ligand concentration, the length of spacer arm, and the nature of metal ion were investigated in immobilized metal affinity chromatography (IMAC). The MAbs against mutant amidase adsorbed to Cu(II), Ni(II), Zn(II), Co(II), and Ca(II)-iminodiacetic acid (IDA) agarose columns. The increase in ligand concentration (epichlorohydrin: 30–60 and 1,4-butanediol-diglycidyl ether: 16–36) resulted in higher adsorption to IgM into immobilized metal chelates. The length of spacer arm was found to affect protein adsorption, as longer spacer arm (i.e., 1,4-butanediol-diglycidyl ether) increased protein adsorption of immobilized metal chelates. The adsorption of IgM onto immobilized metal chelates was pH dependent because an increase in the binding of IgM was observed as the pH varied from 6.0 to 8.0. The adsorption of IgM to immobilized metal chelates was the result of coordination of histidine residues to metal chelates that are available in the third constant domain of heavy chain (CH3) of immunoglobulins, as the presence of imidazole (5 mM) in the equilibration buffer abolished the adsorption of IgM to the column. The combination of tailor-made stationary phases for IMAC and a correct design of the adsorption parameters permitted to devise a one-step purification procedure for IgM. Culture supernatants containing IgM against mutant amidase (T103I) were purified either by IMAC on EPI-60-IDA-Co (II) column or by gel filtration chromatography on Sephacryl S-300HR. The specific content of IgM and final recovery of antibody activity exhibited similar values for both purification schemes. The purified preparations of IgM obtained by both schemes were apparently homogeneous on native polyacrylamide gel electrophoresis with a M r of 851,000 Da. The results presented in this work strongly suggest that one-step purification of IgM by IMAC is a cost-effective and process-compatible alternative to other types of chromatography.  相似文献   

4.
The chromatographic behaviour of monoclonal antibodies (MAbs) of IgM class against mutant (T103I) amidase from Pseudomonas aeruginosa was investigated. The effect of ligand concentration, the length of spacer arm and the nature of metal ion were investigated on immobilized metal ion affinity chromatography (IMAC). MAbs against mutant amidase adsorbed to Cu (II), Ni (II), Zn (II), Co (II) and Ca (II)-IDA agarose columns. The adsorption of MAbs onto immobilized metal chelates was pH dependent because an increase in the binding of MAbs was observed as the pH was raised from 6.0 to 8.0. The adsorption of MAbs to metal chelates was due to coordination of histidine residues which are available in the 3rd constant domain of heavy chain (CH3) of immunoglobulins since the presence of imidazole in the equilibration buffer abolished the adsorption of MAbs to the column packed with commercial IDA-Zn(II) agarose at pH 8.0. The combination of tailor-made stationary phases for IMAC and a correct choice of the adsorption conditions permitted to design a one-step purification procedure for MAbs of IgM class. Culture supernatants containing MAbs of IgM class against mutant amidase (T103I) were chromatographed by IMAC Co (II) column at pH 8.0. The results strongly suggest that one-step purification of MAbs of IgM class by IMAC is a cost-effective and process-compatible alternative to the other purification procedures.  相似文献   

5.
A fragment of the Envelope protein of Dengue 2 virus encoding the amino acid (aa) 286-426 was fused to the P64k protein from Neisseria meningitidis. The hybrid gene (PD5) was expressed in Escherichia coli. The influence of using immobilized metal ion affinity chromatography (IMAC) in the purification process of PD5 was examined. After the elution, PD5 protein formed aggregates of high molecular weight depending on disulfide-bonds. The study of different conditions affecting the redox potential in the system revealed the influence of the copper ions on the multimerization of the protein, whereas metals with minor redox potential-for instance, zinc or nickel ions-did not cause this effect. It was also demonstrated that cysteines involved in this process belonged to the P64k protein. Finally, a PD5 purification process was established reaching a 85% of purity using the Zn(2+) as metal ion in the IMAC. This is a very useful finding due to the wide use of P64k as a carrier protein and the advantages of the IMAC as a chromatographic process.  相似文献   

6.
Heterologous proteins are frequently purified by immobilized metal ion affinity chromatography (IMAC) based on their modification with a hexa-histidine affinity tag (His-tag). The terminal His-tag can, however, alter functional properties of the tagged protein. Numerous strategies for the tag removal have been developed including chemical treatment and insertion of protease target sequences in the protein sequence. Instead of using these approaches, we took an advantage of natural interaction of zinc finger domains with metal ions to purify functionally similar retroviral proteins from two different retroviruses. We found that these proteins exhibited significantly different affinities to the immobilized metal ions, despite that both contain the same type of zinc finger motif (i.e., CCHC). While zinc finger proteins may differ in biochemical properties, the multitude of IMAC platforms should allow relatively simple yet specific method for their isolation in native state.  相似文献   

7.
The chromatographic behavior of monoclonal antibodies (MAbs) of immunoglobulin (Ig) M class against mutant (T103I) amidase from Pseudomonas aeruginosa was investigated on immobilized metal chelates. The effect of ligand concentration, the length of spacer arm, and the nature of metal ion were investigated in immobilized metal affinity chromatography (IMAC). The MAbs against mutant amidase adsorbed to Cu(II), Ni(II), Zn(II), Co(II), and Ca(II)-iminodiacetic acid (IDA) agarose columns. The increase in ligand concentration (epichlorohydrin: 30-60 and 1,4-butanediol-diglycidyl ether: 16-36) resulted in higher adsorption to IgM into immobilized metal chelates. The length of spacer arm was found to affect protein adsorption, as longer spacer arm (i.e., 1,4-butanediol-diglycidyl ether) increased protein adsorption of immobilized metal chelates. The adsorption of IgM onto immobilized metal chelates was pH dependent because an increase in the binding of IgM was observed as the pH varied from 6.0 to 8.0. The adsorption of IgM to immobilized metal chelates was the result of coordination of histidine residues to metal chelates that are available in the third constant domain of heavy chain (CH3) of immunoglobulins, as the presence of imidazole (5 mM) in the equilibration buffer abolished the adsorption of IgM to the column. The combination of tailor-made stationary phases for IMAC and a correct design of the adsorption parameters permitted to devise a one-step purification procedure for IgM. Culture supernatants containing IgM against mutant amidase (T103I) were purified either by IMAC on EPI-60-IDA-Co (II) column or by gel filtration chromatography on Sephacryl S-300HR. The specific content of IgM and final recovery of antibody activity exhibited similar values for both purification schemes. The purified preparations of IgM obtained by both schemes were apparently homogeneous on native polyacrylamide gel electrophoresis with a Mr of 851,000 Da. The results presented in this work strongly suggest that one-step purification of IgM by IMAC is a cost-effective and processcompatible alternative to other types of chromatography.  相似文献   

8.
金属螯合亲和层析分离蛋白质的研究   总被引:17,自引:2,他引:15  
金属螯合亲和层析是近20年发展起来的一项新型分离技术。它以配基简单、吸附量大、分离条件温和、通用性强等特点,逐渐成为分离纯化蛋白质等生物工程产品最有效的技术之一。本文从单组分蛋白质入手,考查了pH值、铵离子浓度、不同铵盐等对蛋白质洗脱的影响,并进行了分析。还对不同的金属螯合柱和不同性质蛋白质的洗脱性能进行了研究,比较了不同金属离子与蛋白质亲和力的区别,为实际体系的分离研究打下了基础。  相似文献   

9.
Immobilized metal ion affinity chromatography.   总被引:14,自引:0,他引:14  
The introduction of immobilized metal ion affinity chromatography, directed toward specific protein side chains, has opened a new dimension in protein purification. This review covers the principles and practice of IMAC that can be performed under very mild, nondenaturing conditions. IMAC is particularly suitable for preparative group fractionation of complex extracts and biofluids, but can also be used in high-performance mode: "HP-IMAC." Single-step purifications of 1000-fold or more may allow isolation of a particular protein from crude extracts on a milligram or gram scale. With respect to separation efficiency, IMAC compares well with biospecific affinity chromatography, and the immobilized metal ion ligand complexes are more likely to withstand wear and tear than are antibodies or enzymes. The enormous potential of IMAC and related metal affinity techniques is only in the initial stages of being explored and exploited. Synthesis of IMA adsorbents, and various modes of performing IMAC are discussed and exemplified with selected applications. Advantages and disadvantages are listed. Effective means of counteracting the few undesirable effects that can occur are suggested.  相似文献   

10.
Immobilized metal affinity chromatography (IMAC) is widely used for protein purification, e.g., in the isolation of proteins bearing the well-known hexahistidine affinity tag. We report that IMAC matrixes can also adsorb single-stranded nucleic acids through metal ion interactions with aromatic base nitrogens and propose that metal affinity technologies may find widespread application in nucleic acid technology. Oligonucleotide duplexes, plasmid, and genomic DNA show low IMAC binding affinity, while RNA and single-stranded oligonucleotides bind strongly to matrixes such as Cu(II) iminodiacetic acid (IDA) agarose. The affinity of yeast RNA for IDA-chelated metal ions decreases in the following order: Cu(II), Ni(II), Zn(II), and Co(II). Adsorption isotherms for 20-mer oligonucleotide homopolymers show that purines are strongly favored over pyrimidines and that double-stranded duplexes are not bound. IMAC columns have been used to purify plasmid DNA from E. coli alkaline lysates, to purify a ribozyme, to remove primers and imperfect products from PCR reactions, and to separate 20-mer oligonucleotide duplexes containing centered single-base mismatches. Potential further applications include SNP scoring, hybridization assays, and the isolation of polyadenylated messenger RNA.  相似文献   