首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 20 毫秒
1.
A method is described for construction of a novel amperometric triglyceride (TG) biosensor based on covalent co-immobilization of lipase, glycerol kinase (GK) and glycerol-3-phosphate oxidase (GPO) onto chitosan (CHIT) and zinc oxide nanoparticles (ZnONPs) composite film deposited on the surface of Pt electrode. The enzymes-ZnONPs-CHIT composite was characterized by X-ray diffraction (XRD), scanning electron microscope (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The sensor showed optimum response within 6 s at pH 7.5 and temperature of 35 °C. The sensor measures current due to electrons generated at 0.4 V against Ag/AgCl from H2O2, which is produced from triolein by co-immobilized enzymes. A linear relationship was obtained between a wide triolein concentration range (50-650 mg/dl) and current (mA) under optimum conditions. The biosensor showed high sensitivity, low detection limit (20 mg/dl) and good storage stability (half-life of 7 months at 4 °C). The biosensor was unaffected modified by a number of serum substances at their physiological concentrations. The biosensor was evaluated and employed for determination of TG in sera in apparently healthy subjects and persons suffering from hypertriglyceridemia.  相似文献   

2.
An amperometric multienzyme biosensor for determination of triglycerides (TGs) was constructed by mounting three gelatin membrane-bound enzymes on a glassy carbon electrode (working electrode), then connecting it to electrometer along with an Ag/AgCl reference electrode and a Pt auxiliary electrode. Characterization and optimization of the multienzyme biosensor, which is prepared with glycerol kinase (GK) (E.C.2.7.1.30), glycerol-3-phosphate oxidase (GPO) (EC 1.1.3.21), and lipase (EC 3.1.1.3), were studied. In the optimization studies for the bioactive layer components of the prepared biosensor, the optimum amounts of gelatin, bovine serum albumin (BSA), and glutaraldehyde was calculated as 1 mg/cm2, 1 mg/cm2, and 2.5%, respectively. Optimum pH and temperature of the reaction of biosensor were determined as 7.0 and 40°C, respectively. Linear range of triolein for the biosensor was found from the calibration curve between several substrate concentration and Δ Current. After optimization and characterization of the biosensor, its operationability in triglycerides was also tested.  相似文献   

3.
We describe the amplification of amperometric l-lysine biosensor using l-lysine oxidase nanoparticles (LOxNPs) and graphene oxide nanoparticles (GrONPs) immobilized onto pencil graphite electrode (PGE). LOxNPs and GrONPs were characterized by UV spectroscopy and transmission electron microscopy (TEM). The working electrode (LOxNPs/GrONPs/PGE) was studied by scanning electron microscopy (SEM) and cyclic voltammetry at different stages of its construction. The biosensor showed optimum current at 0.7 V, pH 6.5, 35 °C, a detection limit of 0.01 μM, response time as 3.95 s and a wider linear range 0.01–1000 μM. The analytical recovery of added lysine in sera was 97 %. The within assay and between batch coefficients of variation for the biosensor were 0.068 and 0.074 % respectively. The biosensor measured l-lysine levels in sera of healthy adults and human immunodeficiency virus (HIV) patients. The biosensor exhibited good correlation with standard spectrophotometric method (R2 = 0.989). The biosensor lost 35 % of its original activity after its regular uses for a period of 180 days, while being stored dry at 4 °C.  相似文献   

4.
A novel amperometric lactate biosensor was developed based on immobilization of lactate dehydrogenase onto graphene oxide nanoparticles‐decorated pencil graphite electrode. The enzyme electrode was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy (FTIR), and cyclic voltammetry at different stages of its construction. The biosensor showed optimum response within 5 s at pH 7.3 (0.1 M sodium phosphate buffer) and 35°C, when operated at 0.7 V. The biosensor exhibited excellent sensitivity (detection limit as low as 0.1 μM), fast response time (5 s), and wider linear range (5–50 mM). Analytical recovery of added lactic acid in serum was between 95.81–97.87% and within‐batch and between‐batch coefficients of variation were 5.04 and 5.40%, respectively. There was a good correlation between serum lactate values obtained by standard colorimetric method and the present biosensor (r = 0.99). The biosensor measured lactate levels in sera of apparently healthy subjects and persons suffering from lactate acidosis and other biological materials (milk, curd, yogurt, beer, white wine, and red wine). The enzyme electrode lost 25% of its initial activity after 60 days of its regular uses, when stored dry at 4°C.  相似文献   

5.
We describe the preparation of glutaraldehyde cross-linked and functionalized cholesterol esterase nanoparticles (ChENPs) and cholesterol oxidase nanoparticles (ChOxNPs) aggregates and their co-immobilization onto Au electrode for improved amperometric determination of serum total cholesterol. Transmission electron microscope (TEM) images of ChENPs and ChOxNPs showed their spherical shape and average size of 35.40 and 56.97 nm, respectively. Scanning electron microscope (SEM) studies of Au electrode confirmed the co-immobilization of enzyme nanoparticles (ENPs). The biosensor exhibited optimal response at pH 5.5 and 40 °C within 5 s when polarized at +0.25 V versus Ag/AgCl. The working/linear range of the biosensor was 10–700 mg/dl for cholesterol. The sensor showed high sensitivity and measured total cholesterol as low as 0.1 mg/dl. The biosensor was evaluated and employed for total cholesterol determination in sera of apparently healthy and diseased persons. The analytical recovery of added cholesterol was 90%, whereas the within-batch and between-batch coefficients of variation (CVs) were less than 2% and less than 3%. There was a good correlation (r = 0.99) between serum cholesterol values as measured by the standard enzymic colorimetric method and the current method. The initial activity of ENPs/working electrode was reduced by 50% during its regular use (200 times) over a period of 60 days when stored dry at 4 °C.  相似文献   

6.
A nickel hexacyanoferrate polypyrrole film was synthesized through an electrochemical two-step methodology leading to a very stable and homogenous robust hybrid film. A highly sensitive, specific and rapid amperometric d-amino acid biosensor was constructed by immobilizing d-amino acid oxidase on this film deposited over the surface of a glassy carbon electrode. The modified electrode was characterized by scanning electron microscopy, electrochemical impedance spectroscopy and Fourier transform infrared spectrophotometry. The biosensor showed optimum response within 1 s, when operated at 50 mV s?1 in 0.01 M Tris HCl buffer, pH 7.0 at 30 °C. The biosensor exhibited excellent sensitivity with a detection limit of 1.5 µM (S/N = 3) for d-amino acids and wider linear range, 20–500 µM. Analytical recovery of added d-alanine (5 and 10 mM) in serum samples was 98.00 and 98.80 %, respectively. Within-batch and between-batch coefficients of variation in serum samples were 1.36 and 2.77 %, respectively. The enzyme electrode was used more than 50 times over 2 months, when stored at 4 °C. The proposed modified electrode exhibited sufficient mechanical and electrochemical stability and high sensitivity compared to earlier electrochemical d-amino acid biosensors. Interference by ascorbic acid and uric acid, the main interfering species in the biological samples, was negligible.  相似文献   

7.
A method is described for construction of an improved amperometric acrylamide biosensor based on covalent immobilization of hemoglobin (Hb) onto nanocomposite of carboxylated multi-walled carbon nanotubes (cMWCNT) and iron oxide nanoparticles (Fe3O4NPs) electrodeposited onto Au electrode through chitosan (CHIT) film. The Hb/cMWCNT-Fe3O4NP/CHIT/Au electrode was characterized by scanning electron microscopy, Fourier transform infra-red spectroscopy, electrochemical impedance spectroscopy, and differential pulse voltammetry at different stages of its construction. The biosensor was based on interaction between acrylamide and Hb, which led to decrease in the electroactivity of Hb, i.e., current generated during its reversible conversion [Fe(II)/Fe(III)]. The biosensor showed optimum response within 8 s at pH 5.0 and 30 °C. The linear working range for acrylamide was 3–90 nM, with a detection limit of 0.02 nM and sensitivity of 36.9 μA/nM/cm2. The biosensor was evaluated and employed for determination of acrylamide in potato crisps.  相似文献   

8.
A sulfite oxidase (SO(X)) (EC 1.8.3.1) purified from Syzygium cumini leaves was immobilized onto carboxylated gold coated magnetic nanoparticles (Fe(3)O(4)@GNPs) electrodeposited onto the surface of a gold (Au) electrode through N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide (EDC)-N-hydroxy succinimide (NHS) chemistry. An amperometric sulfite biosensor was fabricated using SO(X)/Fe(3)O(4)@GNPs/Au electrode as working electrode, Ag/AgCl as standard and Pt wire as auxiliary electrode. The working electrode was characterized by Fourier Transform Infrared (FTIR) Spectroscopy, Cyclic Voltammetry (CV), Scanning Electron Microscopy (SEM) and Electrochemical Impedance Spectroscopy (EIS) before and after immobilization of SO(X). The biosensor showed optimum response within 2s when operated at 0.2V (vs. Ag/AgCl) in 0.1 M Tris-HCl buffer, pH 8.5 and at 35 °C. Linear range and detection limit were 0.50-1000 μM and 0.15 μM (S/N=3) respectively. Biosensor was evaluated with 96.46% recovery of added sulfite in red wine and 1.7% and 3.3% within and between batch coefficients of variation respectively. Biosensor measured sulfite level in red and white wines. There was good correlation (r=0.99) between red wines sulfite value by standard DTNB (5,5'-dithio-bis-(2-nitrobenzoic acid)) method and the present method. Enzyme electrode was used 300 times over a period of 4 months, when stored at 4 °C. Biosensor has advantages over earlier biosensors that it has excellent electrocatalysis towards sulfite, lower detection limit, higher storage stability and no interference by ascorbate, cysteine, fructose and ethanol.  相似文献   

9.
A commercial lysine oxidase (LyOx) from Trichoderma viride was immobilized covalently onto gold nanoparticles (AuNPs) and platinum nanoparticles (PtNPs) electrodeposited onto Au electrode using 3-aminopropyltriethoxy silane (3-APTES) and glutaraldehyde cross linking chemistry. A lysine biosensor was fabricated using LyOx/3-APTES/AuNPs-PtNPs/Au electrode as a working electrode, Ag/AgCl (3 M KCl) as standard electrode and Pt wire as auxiliary electrode connected through a potentiostat. The enzyme electrode was characterized by scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy, electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The cumulative effect of AuNPs and PtNPs showed excellent electrocatalytic activity at low applied potential for detection of H2O2, a product of LyOx reaction. The sensor showed its optimum response within 4 s, when polarized at 0.2 V vs. Ag/AgCl in 0.1 M phosphate buffer, pH 7.5 at 30 °C. The linear range and detection limit of the sensor were 1.0–600 μM and 1.0 μM (S/N = 3), respectively. Biosensor measured lysine level in sera, milk and amino acid tablet, which correlated well with those by standard HPLC method. The enzyme electrode lost 50% of its initial activity after 200 uses over a period of 4 months.  相似文献   

10.
A method is described for construction of an amperometric biosensor for detection of phenolic compounds based on covalent immobilization of laccase (Lac) onto manganese dioxide nanoparticles (MnO(2)NPs) decorated carboxylated multiwalled carbon nanotubes (cMWCNTs)/PANI composite electrodeposited onto a gold (Au) electrode through N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxy succinimide (NHS) chemistry. The modified electrode was characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The biosensor showed optimum response at pH 5.5 (0.1M sodium acetate buffer) and 35°C, when operated at 0.3 V vs. Ag/AgCl. Linear range, response time, detection limit were 0.1-10 μM (lower concentration range) and 10-500 μM (higher concentration range), 4s and 0.04 μM, respectively. Biosensor measured total phenolic content in tea leaves extract. The enzyme electrode was used 150 times over a period of 5 months.  相似文献   

11.
In this work, a highly sensitive acetylcholinesterase (AChE) inhibition-based amperometric biosensor has been developed. Firstly, a glassy carbon electrode (GCE) was modified with chitosan (Chits). Then, hollow gold nanospheres (HGNs) were absorbed onto the surface of chitosan based on the strong affinity through electrostatic adsorption. After that, l-cysteine (l-cys) was assembled on HGNs through Au–S bond. The hollow gold nanospheres were prepared by using Co nanoparticles as sacrificial templates and characterized by scanning electron microscopy, transmission electron microscopy and ultraviolet spectra, respectively. Finally, AChE was immobilized with covalent binding via –COOH groups of l-cysteine onto the modified GCE. The AChE biosensor fabrication process was characterized by cyclic voltammetry and electrochemical impedance spectroscopy methods with the use of ferricyanide as an electrochemical redox indicator. Under optimum conditions, the inhibition rates of pesticides were proportional to their concentrations in the range of 0.1–150 and 0.1–200 μg L?1 for chlorpyrifos and carbofuran, respectively, the detection limits were 0.06 μg L?1 for chlorpyrifos and 0.08 μg L?1 for carbofuran. Moreover, the biosensor exhibited a good stability and reproducibility and was suitable for trace detection of pesticide residues in vegetables and fruits.  相似文献   

12.
3-Hydroxybutyrate, one of the main blood ketone bodies, has been considered as a critical indicator for diagnosis of diabetic ketoacidosis. Biosensors designed for detection of 3-hydroxybutyrate with advantages of precision, easiness and speedy performance have attracted increasing attention. This study attempted to develop a 3-hydroxybutyrate dehydrogenase-based biosensor in which single-walled carbon nanotubes (SWCNT) was used in order to immobilize the cofactor, NAD+, on the surface of screen-printed electrode. The formation of NAD+–SWCNT conjugates was assessed by electrochemistry and electron microscopy. Cyclic voltammetry was used to analyze the performance of this biosensor electrochemically. The considerable shelf life and reliability of the proposed biosensor to analyze real sample was confirmed by this method. The reduction in the over potential of electrochemical oxidation of NADH to ?0.15 V can be mentioned as a prominent feature of this biosensor. This biosensor can detect 3-hydroxybutyrate in the linear range of 0.01–0.1 mM with the low detection limit of 0.009 mM. Simultaneous application of screen-printed electrode and SWCNT has made the biosensor distinguished which can open new prospects for detection of other clinically significant metabolites.  相似文献   

13.
A sulfite oxidase (SOX) (EC 1.8.3.1) purified from Syzygium cumini leaves was immobilized onto Prussian blue nanoparticles/polypyrrole (PBNPs/PPY) nanocomposite film electrodeposited onto the surface of gold (Au) electrode. An electrochemical sulfite biosensor was fabricated using SOX/PBNPs/PPY/Au electrode as working electrode, Ag/AgCl as standard electrode and Pt wire as auxiliary electrode connected through a potentiostat. The working electrode was characterized by Fourier Transform infrared (FTIR) spectroscopy, cyclic voltammetry (CV), scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS) at different stages of its construction. The biosensor showed optimum response within 2 s, when operated at 20 mV s−1 in 0.1 M Tris–HCl buffer, pH 8.0 and at 30 °C. Linear range and minimum detection limit were 0.5–1000 μM and 0.1 μM (S/N = 3) respectively. The sensor was evaluated with 95.0% recovery of added sulfite in red wine samples and 1.9% and 3.3% within and between batch coefficients of variation respectively. There was a good correlation (r = 0.96) between red wine samples sulfite value by standard DTNB method and the present method. The sensor was employed for determination of sulfite level in red, white and rose wine samples. The enzyme electrode was used 300 times over a period of 4 months, when stored at 4 °C.  相似文献   

14.
A nylon membrane based amperometric biosensor employing banana fruit polyphenol oxidase (PPO) is presented for polyphenol detection. Nylon membrane was first activated and then coupled with chitosan. PPO was covalently attached to this membrane through glutaraldehyde coupling. The membrane bioconjugate was characterized by scanning electron microscopy (SEM) and Fourier Transform Infrared (FTIR) study and then mounted onto Au electrode using parafilm to construct a working electrode. Once assembled along with Ag/AgCl as reference and Pt as auxiliary electrode, the biosensor gave optimum response within 15 s at pH 7.5 and 30 °C, when polarized at +0.4 V. The response (in mA) was directly proportional to polyphenol concentration in the range 0.2–400 μM. The lower detection limit of the biosensor was 0.2 μM. The biosensor was employed for determination of polyphenols in tea, beverages and water samples. The enzyme electrode showed 25% decrease in initial activity after 150 reuses over 6 months, when stored at 4 °C.  相似文献   

15.
Gold nanoparticles have enormous applications in cancer treatment, drug delivery and nanobiosensor due to their biocompatibility. Biological route of synthesis of metal nanoparticles are cost effective and eco-friendly. Acinetobacter sp. SW 30 isolated from activated sewage sludge produced cell bound as well as intracellular gold nanoparticles when challenged with HAuCl4 salt solution. We first time report the optimization of various physiological parameters such as age of culture, cell density and physicochemical parameters viz HAuCl4 concentration, temperature and pH which influence the synthesis of gold nanoparticles. Gold nanoparticles thus produced were characterized by various analytical techniques viz. UV–Visible spectroscopy, X-ray diffraction, cyclic voltammetry, transmission electron microscopy, selected area electron diffraction, high resolution transmission electron microscopy, environmental scanning electron microscopy, energy dispersive X-ray spectroscopy, atomic force microscopy and dynamic light scattering. Polyhedral gold nanoparticles of size 20 ± 10 nm were synthesized by 24 h grown culture of cell density 2.4 × 109 cfu/ml at 50 °C and pH 9 in 0.5 mM HAuCl4. It was found that most of the gold nanoparticles were released into solution from bacterial cell surface of Acinetobacter sp. at pH 9 and 50 °C.  相似文献   

16.
A specific 5′ NH2 labeled DNA probe of speB gene was immobilized onto the gold nanoparticles/carboxylated multi walled carbon nanotubes (Nano-Au/cMWCNT) screen printed electrode using EDC/NHS cross linking chemistry. This was followed by hybridization with 0.5–50 ng/6 µl of single stranded genomic DNA Streptococcus pyogenes infected patient throat swab samples. Electrochemical amperometric assay was deciphered by using cyclic voltammetry (CV) with methylene blue a redox indicator. The sensor had a sensitivity of 104.7 µA cm?2 ng?1 using CV with a R2 of 0.907 and 0.01 ng/6 µl as the limit of detection (LOD). The modified electrode surface morphology was characterized using scanning electron microscopy. The stability of the electrode was seen at 4 °C for 180 days having 6% loss in the initial current. The sensor is speB gene specific and can detect the pathogen within 30 min.  相似文献   

17.
A sensitive electrochemiluminescence (ECL) biosensor for cholesterol detection based on multifunctional core–shell structured microspheres (Fe3O4@SiO2–Au@mpSiO2) is reported. This microsphere consisted of a core of silica-coated magnetite nanoparticle, an active transition layer of gold nanoparticles and a mesoporous silica shell. Scanning electron microscopy was employed to observe the morphology of the nanomaterials and transmission electron microscopy was used to further confirm the subtle structure of Fe3O4@SiO2–Au@mpSiO2. The microspheres possessed a large surface area that increased enzyme loading, and an active transition layer gold nanoparticles enhanced the ECL signal. They were used to immobilize cholesterol oxidase for cholesterol detection with a high sensitivity, low detection limit and wide linear range. The linear range was from 0.83 to 2.62 mM with a detection limit of 0.28 µM (S/N = 3). Moreover, the reproducibility, stability and selectivity of the biosensor were established.  相似文献   

18.
An immunosensor with rapid and ultrasensitive response for vascular endothelial growth factor (VEGF) has been built up with 4-aminothiophenol (4-ATP) onto the gold surfaces. Quantitative analysis of VEGF was performed by recording the impedance changing of the gold electrode surface by binding of VEGF. The human vascular endothelial growth factor receptor 1 (VEGF-R1, Flt-1) was used as a biorecognition element for the first time in the literature. VEGF-R1 was covalently immobilized via 4-ATP self-assembled monolayer formed on gold thin film covered surface. Construction of the biosensor was carefully characterised by the techniques such as electrochemistry and electrochemical impedance spectroscopy. In order to characterize impedance data, Kramers–Kronig transform was performed on the experimental impedance data. The limit of detection of the immunosensor for qualitative detection was 100 pg/mL while the LOD for quantitative detection could down to 100 pg/mL by using the VEGF-R1 based biosensor. Finally, artificial serum samples spiked with VEGF was analyzed by the proposed immunosensor to investigate useful of the biosensor for early biomarker diagnosis.  相似文献   

19.
The present work is reporting on the fabrication of localized surface plasmonic resonant (LSPR) gold nano-structures on glass substrate by using different high annealing temperatures (500 °C, 550 °C, 600 °C) of initially created semi-continue gold films (2 nm and 5 nm) by the electron beam evaporation technique. Interestingly, well-defined gold nano-structures were also obtained from continuous 8 nm evaporated gold film - known as the value above gold percolated thickness - once exposed to high temperatures. The surface morphology and plasmonic spectroscopy of “annealed” nano-structures were controlled by key experimental parameters such as evaporated film thickness and annealing temperature. By using scanning electron microscopy (SEM) characterization of annealed surface it was noticed that the size and inter-particle distance between nano-structures were highly dependent on the evaporated thin film thickness, while the nanoparticle shape evolution was mainly affected by the employed annealing temperature. Due to the well-controlled morphology of gold nano-particles, prominent and stable LSPR spectra were observed with good plasmon resonance tunability from 546 nm to 780 nm that recommend the developed protocol as a robust alternative to fabricate large scale LSPR surface. An example of a LSPR-immunosensor is reported. Thus, the monoclonal anti-atrazine antibodies immobilizion on the “annealed” gold nano-structures, as well as the specific antigen (atrazine) recognition were monitored as variations of the resonance wavelength shifts and optical density changes in the extinction measurements.  相似文献   

20.
This present study was aimed to fabricate a sensitive and improved amperometric biosensor by the nanoparticles of pyruvate oxidase, which were prepared and immobilized covalently onto pencil graphite electrode. The biosensor showed ideal working within 5 s under defined conditions of pH 6.0 and incubation temperature of 30 °C at an applied voltage of -0.1 V. Under standard assay conditions, a linear response was obtained between pyruvate concentration ranging from 0.001 to 6000 μM and current (μA). A lower detection limit (0.58 μM) and an excellent correlation coefficient (R2 = 0.999) with standard spectrophotometric assay was obtained for the present biosensor. Within and between batches of coefficients of variation were calculated and found to be 3.61 % and 3.33 %, respectively. The biosensor was put to continual use for over 210 days. The biosensor was employed for the measurement of pyruvate level in sera of normal healthy individuals and persons suffering from heart disease.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号