首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The purpose of this study was to determine the stability and accuracy of active knee joint velocity replication methods in healthy subjects. We used a repeated measures design with 14 healthy volunteers. Measures of velocity replication were performed in two ranges of knee joint flexion (0 degrees -30 degrees and 60 degrees -90 degrees ), across four testing velocities (5, 10, 15, and 30 degrees /s) in two movement directions (flexion and extension). Statistical analysis included intraclass correlation coefficients (ICCs; 2, k) and associated standard error of the measures calculated between day 1 and 2. We performed z-tests between all possible combinations of ICC pairs using Fisher's Z transformations to determine if any significant differences existed between observed ICCs. We also calculated correlation ratios (eta2) to explain the source of variability in the calculated ICCs. To assess measurement accuracy, we calculated constant error and absolute error between criterion and replication velocities. Results on ICCs and standard error of the measurements (SEMs) ranged from r = -0.44 +/- 7.00 to 0.88 +/- 0.72 degrees /s. Calculated z-tests indicated six paired ICCs were significantly different ( p < 0.1). In all six pairs, the faster test velocity had a lower ICC magnitude. The eta2 calculations demonstrated that inconsistent performance between day 1 and 2 caused the low ICC magnitudes observed with faster testing velocities. Significantly more absolute error occurred at 30 and 15 degrees /s compared with 5 degrees /s. Significantly less constant error was observed for 30 degrees /s compared with 15 degrees /s. A significant direction by range of motion interaction indicated less constant error for flexion movements in the 60 degrees -90 degrees range of motion (ROM) as compared with extension movements in either ROM. Healthy individuals could actively replicate slower criterion velocities in the mid and end ranges of knee joint motion in both movement directions with an acceptable amount of consistency and accuracy. The data support the use of velocity replication in future investigations on proprioceptive function.  相似文献   

2.
This study tested the hypothesis that the effect of hip joint angle on concentric knee extension torque depends on knee joint angle during a single knee extension task. Twelve men performed concentric knee extensions in fully extended and 80° flexed hip positions with maximal effort. The angular velocities were set at 30° s−1 and 180° s−1. The peak torque and torques attained at 30°, 50°, 70° and 90° (anatomical position = 0°) of the knee joint were compared between the two hip positions. Muscle activations of the vastus lateralis, medialis, rectus femoris and biceps femoris were determined using surface electromyography. The peak torque was significantly greater in the flexed than in the extended hip position irrespective of angular velocity. The torques at 70° and 90° of the knee joint at both angular velocities and at 50° at 180° s−1 were significantly greater in the flexed than in the extended hip position, whereas corresponding differences were not found at 30° (at either angular velocity) and 50° (at 30° s−1) of the knee joint. No effect of hip position on muscle activation was observed in any muscle. These results supported our hypothesis and may be related to the force–length and force–velocity characteristics of the rectus femoris.  相似文献   

3.
Abstract

Purpose: Skin contributes to joint position sense (JPS) at multiple joints. Altered cutaneous input at the foot can modulate gait and balance and kinesiology tape can enhance proprioception at the knee, but its effect may be dependent on existing capacity. The effect of texture at the knee, particularly in those with poor proprioception, is unknown. The aim of this study was to determine the effect of textured panels on JPS about the knee.

Materials and methods: Eighteen healthy females were seated in an adjustable chair. Their left leg (target limb) moved passively from 65° to a target of flexion (115° or 90°) or extension (40°). Their right leg (matching limb) was passively moved towards this target angle and participants indicated when their limbs felt aligned. We tested three textured panels over the knee of the matching limb and two control conditions. The target limb maintained a control panel. Directional error, absolute error and variable error in matching between limbs were calculated.

Results: On average textured panels over the knee increased JPS error compared to control pants for participants with poor JPS. These participants undershot the target at 90° of flexion significantly more with textured panels (?11°?±?3°) versus control (?7°?±?3°, p?=?0.04).

Conclusions: For participants with poor JPS accuracy, increased JPS error at 90° with a textured panel suggests these individuals utilised altered cutaneous information to adjust joint position. We propose increased error results from enhanced skin input at the knee leading to the perception of increased flexion.  相似文献   

4.
Inertial Measurement Units (IMUs) are promising alternatives to laboratory-based motion capture methods in biomechanical assessment of athletic movements. The aim of this study was to investigate the validity of an IMU system for determining knee and trunk kinematics during landing and cutting tasks for clinical and research applications in sporting populations. Twenty-seven participants performed five cutting and landing tasks while being recorded using a gold-standard optoelectronic motion capture system and an IMU system. Intra-class coefficients, Pearson’s r, root-mean-square error (RMSE), bias, and Bland-Altman limits of agreements between the motion capture and IMU systems were quantified for knee and trunk sagittal- and frontal-plane range-of-motion (ROM) and peak angles. Our results indicate that IMU validity was task-, joint-, and plane-dependent. Based on good-to-excellent (ICC) correlation, reasonable accuracy (RMSE < 5°), bias within 2°, and limits of agreements within 10°, we recommend the use of this IMU system for knee sagittal-plane ROM estimations during cutting, trunk sagittal-plane peak angle estimation during the double-leg landing task, trunk sagittal-plane ROM estimation for almost all tasks, and trunk frontal-plane peak angle estimation for the right single-leg landing task. Due to poor comparisons with the optoelectronic system, we do not recommend this IMU system for knee frontal-plane kinematic estimations.  相似文献   

5.
This study evaluated between-session reliability of opto-electronic motion capture to measure trunk posture and three-dimensional ranges of motion (ROM). Nineteen healthy participants aged 24–74 years underwent spine curvature, pelvic tilt and trunk ROM measurements on two separate occasions. Rigid four-marker clusters were attached to the skin overlying seven spinous processes, plus single markers on pelvis landmarks. Rigid body rotations of spine marker clusters were calculated to determine neutral posture and ROM in flexion, extension, total lateral bending (left-right) and total axial rotation (left-right). Segmental spine ROM values were in line with previous reports using opto-electronic motion capture. Intraclass correlation coefficients (ICC) and standard error of measurement (SEM) were calculated as measures of between-session reliability and measurement error, respectively. Retroreflective markers showed fair to excellent between-session reliability to measure thoracic kyphosis, lumbar lordosis, and pelvic tilt (ICC = 0.82, 0.63, and 0.54, respectively). Thoracic and lumbar segments showed highest reliabilities in total axial rotation (ICC = 0.78) and flexion-extension (ICC = 0.77–0.79) ROM, respectively. Pelvic segment showed highest ICC values in flexion (ICC = 0.78) and total axial rotation (ICC = 0.81) trials. Furthermore, it was estimated that four or fewer repeated trials would provide good reliability for key ROM outcomes, including lumbar flexion, thoracic and lumbar lateral bending, and thoracic axial rotation. This demonstration of reliability is a necessary precursor to quantifying spine kinematics in clinical studies, including assessing changes due to clinical treatment or disease progression.  相似文献   

6.
The purpose of this study was to examine the effects of moment of antagonistic muscle on the resultant joint moment during isokinetic eccentric and concentric efforts of the knee extensors. Ten males performed maximum eccentric and concentric knee extension and flexion efforts on a Biodex dynamometer at 0.52 rad · s−1 (30° · s−1). Electromyographic (EMG) activity of vastus medialis and biceps femoris (hamstrings) was also recorded. The antagonistic moment of the hamstrings was determined by recording the integrated EMG (iEMG)/moment relationship at different levels of muscle effort. The iEMG/moment curves were fitted using second-degree polynomials. The polynomials were then used to predict the antagonistic moment exerted by the hamstrings from the antagonist iEMG. The antagonistic moment had a maximum of 42.92 Nm and 28.97 Nm under concentric and eccentric conditions respectively; paired t-tests indicated that this was a significant difference (P < 0.05). These results indicate that the resultant joint moment of knee extensors is the result of both agonist and antagonist muscle activation. The greater antagonist muscle activity under concentric activation conditions may be partly responsible for the lower resultant joint concentric moment of knee extensors compared with the corresponding eccentric activation. The antagonist moment significantly affects comparisons between the isokinetic moments and agonist EMG and in vitro force measurements under different testing (muscle action and angular velocity) conditions. Accepted: 25 February 1997  相似文献   

7.
Previous in vivo studies have observed that current designs of posterior stabilised (PS) total knee replacements (TKRs) may be ineffective in restoring normal kinematics in Late flexion. Computer-based models can prove a useful tool in improving PS knee replacement designs. This study investigates the accuracy of a two-dimensional (2D) sagittal plane model capable of predicting the functional sagittal plane kinematics of PS TKR implanted knees against direct in vivo measurement. Implant constraints are often used as determinants of anterior–posterior tibio-femoral positioning. This allowed the use of a patello-femoral modelling approach to determine the effect of implant constraints. The model was executed using motion simulation software which uses the constraint force algorithm to achieve a solution. A group of 10 patients implanted with Scorpio PS implants were recruited and underwent fluoroscopic imaging of their knees. The fluoroscopic images were used to determine relative implant orientation using a three-dimensional reconstruction method. The determined relative tibio-femoral orientations were then input to the model. The model calculated the patella tendon angles (PTAs) which were then compared with those measured from the in vivo fluoroscopic images. There were no significant differences between the measured and calculated PTAs. The average root mean square error between measured and modelled ranged from 1.17° to 2.10° over the flexion range. A sagittal plane patello-femoral model could conceivably be used to predict the functional 2D kinematics of an implanted knee joint. This may prove particularly useful in optimising PS designs.  相似文献   

8.
During range of motion (max-ROM) tests performed on an isokinetic dynamometer, the mechanical delay between the button press (by the participant to signal their max-ROM) and the stopping of joint rotation resulting from system inertia induces errors in both max-ROM and maximum passive joint moment. The present study aimed to quantify these errors by comparing data when max-ROM was obtained from the joint position data, as usual (max-ROMPOS), to data where max-ROM was defined as the first point of dynamometer arm deceleration (max-ROMACC). Fifteen participants performed isokinetic ankle joint max-ROM tests at 5, 30 and 60° s−1. Max-ROM, peak passive joint moment, end-range musculo-articular (MAC) stiffness and area under the joint moment-position curve were calculated. Greater max-ROM was observed in max-ROMPOS than max-ROMACC (P < 0.01) at 5 (0.2 ± 0.15%), 30 (1.8 ± 1.0%) and 60° s−1 (5.9 ± 2.3%), with the greatest error at the fastest velocity. Peak passive moment was greater and end-range MAC stiffness lower in max-ROMPOS than in max-ROMACC only at 60° s−1 (P < 0.01), whilst greater elastic energy storage was found at all velocities. Max-ROM and peak passive moment are affected by the delay between button press and eventual stopping of joint rotation in an angular velocity-dependent manner. This affects other variables calculated from the data. When high data accuracy is required, especially at fast joint rotation velocities (≥30° s−1), max-ROM (and associated measures calculated from joint moment data) should be taken at the point of first change in acceleration rather than at the dynamometer’s ultimate joint position.  相似文献   

9.
The purpose of the present study was to determine the day-to-day reliability in stride characteristics in rats during treadmill walking obtained with two-dimensional (2D) motion capture. Kinematics were recorded from 26 adult rats during walking at 8 m/min, 12 m/min and 16 m/min on two separate days. Stride length, stride time, contact time, swing time and hip, knee and ankle joint range of motion were extracted from 15 strides. The relative reliability was assessed using intra-class correlation coefficients (ICC(1,1)) and (ICC(3,1)). The absolute reliability was determined using measurement error (ME). Across walking speeds, the relative reliability ranged from fair to good (ICCs between 0.4 and 0.75). The ME was below 91 mm for strides lengths, below 55 ms for the temporal stride variables and below 6.4° for the joint angle range of motion. In general, the results indicated an acceptable day-to-day reliability of the gait pattern parameters observed in rats during treadmill walking. The results of the present study may serve as a reference material that can help future intervention studies on rat gait characteristics both with respect to the selection of outcome measures and in the interpretation of the results.  相似文献   

10.
In this study we aimed to determine the reliability of the surface electromyography (EMG) of leg muscles during vertical jumping between two test sessions, held 2 weeks apart. Fifteen females performed three maximal vertical jumps with countermovement. The displacement of the body centre of mass (BCM), duration of propulsion phase (time), range of motion (ROM) and angular velocity of the knee and surface EMG of four leg muscles (rectus femoris, vastus medialis. biceps femoris and gastrocnemius) were recorded during the jumps. All variables were analysed throughout the propulsion and mid-propulsion phases. Intraclass correlation coefficients (ICC) for the rectus femoris, vastus medialis, biceps femoris and gastrocnemius were calculated to be 0.88, 0.70, 0.24 and 0.01, respectively. BCM, ROM and time values all indicated ICC values greater than 0.90, and the mean knee angular velocity was slightly lower, at 0.75. ICCs between displacement of the BCM and integrated EMG (IEMG) of the muscles studied were less than 0.50. The angular velocity of the knee did not correlate well with muscle activity. Factors that may have affected reliability were variations in the position of electrode replacement, skin resistance, cross-talk between muscles and jump mechanics. The results of this study suggest that while kinematic variables are reproducible over successive vertical jumps, the degree of repeatability of an IEMG signal is dependent upon the muscle studied.  相似文献   

11.
IntroductionMusculoskeletal modeling allows insight into the interaction of muscle force and knee joint kinematics that cannot be measured in the laboratory. However, musculoskeletal models of the lower extremity commonly use simplified representations of the knee that may limit analyses of the interaction between muscle forces and joint kinematics. The goal of this research was to demonstrate how muscle forces alter knee kinematics and consequently muscle moment arms and joint torque in a musculoskeletal model of the lower limb that includes a deformable representation of the knee.MethodsTwo musculoskeletal models of the lower limb including specimen-specific articular geometries and ligament deformability at the knee were built in a finite element framework and calibrated to match mean isometric torque data collected from 12 healthy subjects. Muscle moment arms were compared between simulations of passive knee flexion and maximum isometric knee extension and flexion. In addition, isometric torque results were compared with predictions using simplified knee models in which the deformability of the knee was removed and the kinematics at the joint were prescribed for all degrees of freedom.ResultsPeak isometric torque estimated with a deformable knee representation occurred between 45° and 60° in extension, and 45° in flexion. The maximum isometric flexion torques generated by the models with deformable ligaments were 14.6% and 17.9% larger than those generated by the models with prescribed kinematics; by contrast, the maximum isometric extension torques generated by the models were similar. The change in hamstrings moment arms during isometric flexion was greater than that of the quadriceps during isometric extension (a mean RMS difference of 9.8 mm compared to 2.9 mm, respectively).DiscussionThe large changes in the moment arms of the hamstrings, when activated in a model with deformable ligaments, resulted in changes to flexion torque. When simulating human motion, the inclusion of a deformable joint in a multi-scale musculoskeletal finite element model of the lower limb may preserve the realistic interaction of muscle force with knee kinematics and torque.  相似文献   

12.
13.
Objectives: Although overuse running injury risks for the ankle and knee are high, the effect of different shoe designs on Achilles tendon force (ATF) and Patellofemoral joint contact force (PTF) loading rates are unclear. Therefore, the primary objective of this study was to compare the ATF at the ankle and the PTF and Patellofemoral joint stress force (PP) at the knee using different running shoe designs (forefoot shoes vs. normal shoes). Methods: Fourteen healthy recreational male runners were recruited to run over a force plate under two shoe conditions (forefoot shoes vs. normal shoes). Sagittal plane ankle and knee kinematics and ground reaction forces were simultaneously recorded. Ankle joint mechanics (ankle joint angle, velocity, moment and power) and the ATF were calculated. Knee joint mechanics (knee joint angle velocity, moment and power) and the PTF and PP were also calculated. Results: No significant differences were observed in the PTF, ankle plantarflexion angle, ankle dorsiflexion power, peak vertical active force, contact time and PTF between the two shoe conditions. Compared to wearing normal shoes, wearing the forefoot shoes demonstrated that the ankle dorsiflexion angle, knee flexion velocity, ankle dorsiflexion moment extension, knee extension moment, knee extension power, knee flexion power and the peak patellofemoral contact stress were significantly reduced. However, the ankle dorsiflexion velocity, ankle plantarflexion velocity, ankle plantarflexion moment and Achilles tendons force increased significantly. Conclusions: These findings suggest that wearing forefoot shoes significantly decreases the patellofemoral joint stress by reducing the moment of knee extension, however the shoes increased the ankle plantarflexion moment and ATF force. The forefoot shoes effectively reduced the load on the patellofemoral joint during the stance phase of running. However, it is not recommended for new and novice runners and patients with Achilles tendon injuries to wear forefoot shoes.  相似文献   

14.
The present study aimed to clarify the effects of knee joint angle on the behavior of the medial gastrocnemius muscle (MG) fascicles during eccentric plantar flexions. Eight male subjects performed maximal eccentric plantar flexions at two knee positions [fully extended (K0) and 90° flexed (K90)]. The eccentric actions were preceded by static plantar flexion at a 30° plantar flexed position and then the ankle joint was forcibly dorsiflexed to 15° of dorsiflexion with an isokinetic dynamometer at 30°/s and 150°/s. Tendon force was calculated by dividing the plantar flexion torque by the estimated moment arm of the Achilles tendon. The MG fascicle length was determined with ultrasonography. The tendon forces during eccentric plantar flexions were influenced by the knee joint angle, but not by the angular velocity. The MG fascicle lengths were elongated as the ankle was dorsiflexed in K0, but in K90 they were almost constant despite the identical range of ankle joint motion. These results suggested that MG fascicle behavior during eccentric actions was markedly affected by the knee joint angle. The difference in the fascicle behavior between K0 and K90 could be attributed to the non-linear force–length relations and/or to the slackness of tendinous tissues.  相似文献   

15.
Patellofemoral pain syndrome (PFPS) is a disorder of the patellofemoral (PF) joint in which abnormal tracking is often cited as a factor in pain development. PF tracking is partially dependent on passive stabilizers (ex: PF geometry). Relations amongst PFPS, PF tracking, and contact mechanics are poorly understood. In-vivo investigation of passive PF joint stabilizers including PF tracking, contact mechanics, cartilage thickness, and patellar shape will allow structural characterization of the PF joint and may highlight differences associated with PFPS. This study examined the role that passive stabilizers play in PFPS (n=10) versus healthy subjects (n=10). PF tracking (contact area centroid migration), cartilage thickness, shape, congruence, and contact patterns were quantified using magnetic resonance imaging during isometric loading at 15°, 30°, and 45° of knee flexion. Distinct relationships were identified between patellar shape and tracking and contact, particularly at low flexion (15–30°). Healthy subjects exhibited distinct PF tracking and contact patterns related to Type I patella shape (80%) with increasing total contact area (p<0.001) and proximal centroid migration (15–30° p=0.012; 30–45° p<0.001) for increasing knee angles. PFPS subjects deviated from these patterns at low flexion, demonstrating higher total contact area than healthy subjects (p=0.046 at 15°), lack of proximal centroid migration (15–30°), and more Type II (30%) and III (20%) patella shapes. This study highlights a new finding that patellar shape combined with low degrees of flexion (15–30°) may be important to consider, as this is where PFPS tracking and contact patterns deviate from healthy.  相似文献   

16.
While total knee replacement is successful, hemiarthroplasty is necessary for some young, obese and active patients who are especially not suitable for unicompartmental or total knee prostheses. Hemiarthroplasty also provides an opportunity for children with bone tumors. The design ofhemiarthroplasty should be patient-specific to reduce contact stress and friction as well as instability, compared to conventional hemi-knee prosthesis. A novel bipolar hemi-knee prosthesis with two flexion stages was developed according to a healthy male's knee morphological profile. The motion mode of the bipolar hemi-knee prosthesis was observed through roentgenoscopy in vitro experiment. The biomechanical properties in one gait cycle were evaluated though finite element simulation. The bipolar hemi-knee prosthesis was found to produce knee flexion at two stages through X-ray images. The first stage is the motion from upright posture to a specified 60~ flexion, followed by the second stage of motion subsequently to deep flexion. The finite element simulation results also show that the designed hemi-knee prosthesis has the ability to reduce stresses on the joint contact surfaces. Therefore, it is possible for the bipolar hemi-knee prosthesis to provide better biotribological performances because it can reduce stresses and potentially wear on the opposing contacting surface during a gait cycle, orovidin~ a t~romisin~ treatment strate~v in future Joint renair znd renlneement  相似文献   

17.
Total knee arthroplasty (TKA) is the most common joint replacement in the United States. Range of motion (ROM) monitoring includes idealized clinic measures (e.g. goniometry during passive ROM) that may not accurately represent knee function. Accordingly, a novel, portable, inertial measurement unit (IMU) based ROM measurement method was developed, validated, and implemented. Knee flexion was computed via relative motion between two IMUs and validated via optical motion capture (p > 0.05). Prospective analyses of 10 healthy individuals (5M, 50 ± 19 years) and 20 patients undergoing TKA (3 lost to follow up, 10M, 65 ± 6 years) were completed. Controls wore IMUs for 1-week. Patients wore IMUs for 1-week pre-TKA, 6-weeks immediately post-TKA, and 1-week at 1-year post-TKA. Flexion was computed continuously each day (8–12 h). Metrics included daily maximum flexion and flexion during stance/swing phases of gait. Maximum flexion was equal between cohorts at all time points. Contrastingly, patient stance and swing flexion were reduced pre-TKA, yet improved post-TKA. Specifically, patient stance and swing flexion were reduced below control/pre-TKA values during post-TKA week 1. Stance flexion exceeded pre-TKA and equaled control levels after week 2. However, swing flexion only exceeded pre-TKA and equaled control levels at 1-year post-TKA. This novel method improves upon the accuracy/portability of current methods (e.g. goniometry). Interestingly, surgery did not impact maximum ROM, yet improved the ability to flex during gait allowing more efficient and safe ambulation. This is the first study continuously monitoring long-term flexion before/after TKA. The results offer richer information than clinical measures about expected TKA rehabilitation.  相似文献   

18.
19.
Patient selection for lateral retinacular release (LRR) and its efficacy are controversial. Iatrogenic medial subluxation can occur with inappropriate LRR. The aim of this study was to determine the reduction in patellofemoral stability with progressively more extensive LRR. The force required to displace the patella 10 mm medially and laterally in nine cadaveric knees was measured with and without loading of the quadriceps and iliotibial band. The knee was tested intact, then after progressive release beginning proximal to the patella (PR), the mid-level between the proximal and distal limit of the patella (MR) where the fibres are more transverse, then distally till Gerdy's tubercle (DR) and finally the joint capsule (CR). Both medial and lateral stability decreased with progressive releases, larger for the medial. The MR caused a significant reduction of lateral stability between 30° and 90° of knee flexion. There was an 8% reduction in medial stability at 0° flexion with a complete LRR (DR). A comparable reduction in medial stability in the loaded knee at 20° and 30° flexion was obtained with MR alone, with no further reduction after DR. A capsular release caused a further reduction in medial stability at 0° and 20° and this was marked in the unloaded knee. In extension, the main lateral restraint was the joint capsule. At 30° flexion, the transverse fibres were the main contributor to the lateral restraint.  相似文献   

20.
To date, kinematics data analyzing continuous 3D motion of upper cervical spine (UCS) manipulation is lacking. This in vitro study aims at investigating inter- and intra-operator reliability of kinematics during high velocity low amplitude manipulation of the UCS.Three fresh specimens were used. Restricted dissection was realized to attach technical clusters to each bone (skull to C2). Motion data was obtained using an optoelectronic system during manipulation. Kinematics data were integrated into specific-subject 3D models to provide anatomical motion representation during thrust manipulation. The reliability of manipulation kinematics was assessed for three practitioners performing two sessions of three repetitions on two separate days.For pre-manipulation positioning, average UCS ROM (SD) were 10° (5°), 22° (5°) and 14° (4°) for lateral bending, axial rotation and flexion–extension, respectively. For the impulse phase, average axial rotation magnitude ranged from 7° to 12°. Reliability analysis showed average RMS up to 8° for pre-manipulation positioning and up to 5° for the impulse phase.As compared to physiological ROM, this study supports the limited angular displacement during manipulation for UCS motion components, especially for axial rotation. Kinematics reliability confirms intra- and inter-operator consistency although pre-manipulation positioning reliability is slightly lower between practitioners and sessions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号